At least 163 records · Page 9

Thermal short improves sensitivity of cryogenically cooled maser

In-line, quarter-wave thermal short cools the center conductor of the signal-input coaxial transmission line to a cryogenically cooled traveling wave maser. It reduces both the thermal noise contribution of the coaxial line and the heat leak through the center conductor to the maser at 4.4 degrees K.

Clauss, R. C.↗

Measurement of the power spectral density of phase of the hydrogen maser

Hydrogen masers are being developed for the Deep Space Network as improved frequency standards, in order to achieve better timing accuracies, reduced Doppler residuals, and lower phase noise in the tracking system. Performance data for the masers are given in two forms: time domain performance, useful for analyzing time keeping systems and Doppler systems; and frequency domain performance, useful for analyzing tracking systems. Particular attention is given to frequency domain performance, as obtained from both time domain measurements and direct measurements.

Sward, A.↗

Research on Haystack radiometer, 20-24 GHz maser, and radio astronomy programs

During the first half of 1973, the Haystack antenna was utilized 76% of the time. Of this useful time, 72% was devoted to radio astronomy observing, 5% was spent on radar-related research and 23% went into maintenance and system improvements. Twenty-eight new radio astronomy programs were accepted, eight of which were completed during the period. One new radar program, topographic observations of Mars, was started in June and will be completed early in 1974. Fourteen programs continued from the previous period were also defined as complete. As of 1 July, 28 ratio observing programs were in a continuing status on the Haystack books. Four radar projects were also continuing. The 20-24 GHz maser development described in the preceding report progressed very well during an on-antenna test phase which began early in the year, but which terminated unfortunately in June with the complete loss of gain in the maser. Investigation of this problem is in progress. During this on-antenna test phase, the most sensitive water vapor observing capability which has yet become available was demonstrated.

Source record↗

Light shift effects in the Rb-87 maser

Previous work has shown the possibility to overcome the dependence of the Rb-87 maser frequency on light intensity by tuning the cavity at a proper setting. The conditions for this setting, called the light-independent frequency setting (LIFS), are carefully investigated. The results presented prove the existence of the LIFS and provide a new criterion for an automatic cavity tuning of the Rb maser.

Busca, G.↗

Cavity tuning and light-shift in the Rb-87 maser

A new method for tuning the cavity of the Rb-87 maser is proposed. It is based on the existence of a cavity tuning for which the maser frequency is independent on the light intensity. The features of this method are evaluated theoretically and tested experimentally. Preliminary results obtained by using a closed loop feedback electronic system for tuning the cavity are given.

Busca, G.↗

Infrared pumping processes for SiO masers

The J = 2 to 1 transition of the first excited vibrational state (v = 1) Si(28)O(16) has recently been shown to produce maser amplification near 86,245 MHz in Orion A and in several stars. Two possible pumping mechanisms are proposed for such masers. One involves the near coincidence between the frequencies of the 1-0 (RO) and 3-2 (R18) transitions in Si(28)O(16). The other requires emission by SiO and reabsorption without the necessity for an accidental frequency coincidence. Each of these types of mechanisms may occur for other transitions of molecules in a medium illuminated by intense infrared radiation, or with strong temperature gradients.

Geballe, T. R.↗

Reflected-wave maser

Reflected wave maser amplifier has significantly greater bandwidth than conventional maser amplifiers. Unit needs no retuning to receive wide range of frequencies.

Clauss, R. C.↗

Design and analysis of optically pumped submillimeter waveguide maser amplifiers and oscillators

The design and experimental measurements are described of an optically pumped far-infrared (FIR) waveguide maser; preliminary measurements on a FIR waveguide amplifier are presented. The FIR maser was found to operate satisfactorily in a chopped CW mode using either methanol (CH3OH) or acetonitrile (CH3CN) as the active molecule. Two other gases, difluoroethane and difluoroethylene, produced an unstable output with high threshold and low output power when operated in the chopped CW mode. Experimental measurements include FIR output versus cavity length, output beam pattern, output power versus pressure, and input power. The FIR output was the input to an amplifier which was constructed similar to the oscillator. An increase of 10% in output power was noted on the 118.8 microns line of methanol.

Galantowicz, T. A.↗

An improved method for measuring the magnetic inhomogeneity shift in hydrogen masers

The reported method makes it possible to conduct all maser frequency measurements under conditions of low magnetic field intensity for which the hydrogen maser is most stable. Aspects concerning the origin of the magnetic inhomogeneity shift are examined and the available approaches for measuring this shift are considered, taking into account certain drawbacks of currently used methods. An approach free of these drawbacks can be based on the measurement of changes in a parameter representing the difference between the number of atoms in the involved states.

Reinhardt, V. S.↗

Variable volume maser techniques

The frequency stability of hydrogen masers in variable volume storage bulbs is discussed in terms of wall shift. Variable volume devices discussed include: Brenner flexible bulb, Debely device, and the concertina hydrogen maser. A flexible cone variable volume element outside the cavity is described.

Reinhardt, V. S.↗

Simple waveguide reflection maser with broad tunability

The design and performance of a simple two-stage reflection maser for use between 9 and 10 GHz are described. The maser is used to improve the sensitivity of a transmission electron spin resonance spectrometer. A ruby-filled waveguide structure permits broad tunability and straightforward construction. All microwave components except the ruby section are at room temperature.

Flesner, L. D.↗

Independent gain and bandwidth control of a traveling wave maser

An X-band traveling wave maser of the folded-comb type is presented, with two figure-eight coils for gain and bandwidth control. One figure-eight coil covers the full lengths of the comb structure for bandwidth adjustment of an external magnetic field. The other coil covers a central half of the comb structure for independent gain adjustment of the external magnetic field. The half of each figure-eight coil at the turn around end of the comb structure is oriented to aid the external magnetic field, and the half of each coil at the input-output end of the comb structure is oriented to buck the external magnetic field. The maser is pumped in the push-push mode with two different frequencies.

Trowbridge, D. L.↗

Interstellar bullets - H2O masers and Herbig-Haro objects

The paper considers the energy input to H2O masers in a dense molecular cloud and analyzes the response time scales for both collisional and radiative pump models. Specific mechanisms for magnetic energy input are given. The evolution of dense H2O maser clouds is studied in the environment of a young pre-main-sequence star that has developed an appreciable supersonic wind. It is shown that compact clouds can be ejected at high velocity to distances of order 1 pc. It is suggested that these clouds (referred to as interstellar bullets) might explain the phenomena of Herbig-Haro objects and high-velocity gas motions observed near compact infrared objects.

Norman, C.↗

The performance of NASA research hydrogen masers

Field operable hydrogen masers based on prior maser designs are presented. These units incorporate improvements in magnetic shielding, lower noise electronics, better thermal control, and have a microprocessor for operation, monitoring, and diagnostic functions. They are ruggedly built for transportability and ease of service anywhere in the world.

Reinhardt, V. S.↗

The operational performance of hydrogen masers in the Deep Space Network (the performance of laboratory reference frequency standards in an operational environment)

Spacecraft navigation to the outer planets (Jupiter and beyond) places very stringent demands upon the performance of frequency and time (F&T) reference standards. The Deep Space Network (DSN) makes use of hydrogen masers as an aid in meeting the routine F&T operational requirements within the 64 m antenna network. Results as of October 1980 indicate the hydrogen masers are performing within the required specifications. Two problem areas are discussed: insufficient control over the environment in which the reference standards reside; and frequency drift.

Ward, S. C.↗