Microfabricated force-detected nuclear magnetic resonance spectrometer
Explore the source record for details and available documents.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
The performance of the AGATA Demonstrator Array coupled to the PRISMA magnetic spectrometer have been evaluated in a consistent way using detailed Monte Carlo simulations of the two devices. Results for the {sup 90}Zr+{sup 208}Pb at 560 MeV reaction are presented and discussed here, proving that the Doppler correction capabilities of the AGATA+PRISMA setup will be very close to the intrinsic energy resolution of the germanium detectors.
We propose to assemble a cost-effective, yet powerful, solenoidal magnetic spectrometer for antiproton-annihilation events and use it at the Fermilab Antiproton Accumulator to measure the charm production cross section, study rare hyperon decays, search for hyperon CP asymmetry, and precisely measure the properties of several charmonium and nearby states. Should the charm production cross section be as large as some have proposed, we will also be able to measure D{sup 0}-{bar D}{sup 0} mixing with high precision and discover (or sensitively limit) charm CP violation. The experiment will be carried out by an international collaboration, with installation occurring during the accelerator downtime following the completion of the Tevatron run, and with funding largely from university research grants. The experiment will require some four years of running time. As possibly the sole hadron experiment in progress at Fermilab during that time, it will play an important role in maintaining a broad particle-physics program at Fermilab and in the U.S.
The (d,{sup 2}He) charge-exchange reaction on {sup 76}Se was studied at an incident energy of 183 MeV. The outgoing two protons in the {sup 1}S{sub 0} state, referred to as {sup 2}He, were both momentum analyzed and detected by the same spectrometer and detector. The experiment was performed at KVI, Groningen, using the magnetic spectrometer BBS at three angular positions: 0 deg., 2.5 deg., and 5 deg. Excitation-energy spectra of the residual nucleus {sup 76}As were obtained with an energy resolution of about 120 keV (FWHM). Gamow-Teller (GT{sup +}) transition strengths were extracted up to 5 MeV and compared with those from an (n,p) experiment at low resolution. Together with the GT{sup -} transition strengths from the {sup 76}Ge(p,n) experiment leading to the same intermediate nucleus, the nuclear matrix element of the two-neutrino double-{beta} decay of {sup 76}Ge was evaluated.
A novel design for a compact gamma-ray spectrometer is presented. The proposed system allows for spectroscopy of high-flux multi-MeV gamma-ray beams with MeV energy resolution in a compact design. In its basic configuration, the spectrometer exploits conversion of gamma-rays into electrons via Compton scattering in a low-Z material. The scattered electron population is then spectrally resolved using a magnetic spectrometer. The detector is shown to be effective for gamma-ray energies between 3 and 20 MeV. The main properties of the spectrometer are confirmed by Monte Carlo simulations.
The study of few nucleon systems with electromagnetic probes is an essential component of the scientific program carried out at the Thomas Jefferson National Accelerator Facility (JLab). Here we present measurements of exclusive reactions on light nuclei using real photon beams with energies up to 3 GeV and the CEBAF Large Acceptance Spectrometer (CLAS), a nearly 4π magnetic spectrometer, in order to study the properties of strongly interacting matter and the transition from hadronic (i.e in terms of nucleons and mesons) to partonic (in terms of quark and gluons) degrees of freedom in nuclear interactions. We discuss the progress made in understanding the relevant degrees of freedom using polarisation observables and cross sections of deuteron and 3 He photodisintegration in the few-GeV photon-energy region. In addition, recent high-statistics experiments with the CLAS detector have provided us with sufficient counting rates to study the effects of initial- and final-state interactions in reactions off the deuteron. Such data allow us to extract a large set of polarisation observables for final-state interactions in hyperon photoproduction and to study the properties of the hyperon–nucleon interaction. Initial-state effects are studied by mapping the dependence of experimental observables on the spectator-nucleon momentum. We also present recent results for polarisation observables for quasi-free K + Λ off the bound proton in a deuteron as well as for final-state interactions in the reaction γd→K + Λn , and will discuss their impact on hyperon–nucleon studies.
The controlled transport and imaging of relativistic electron beams from laser plasma accelerators (LPAs) are critical for their diagnostics and applications. Here we present the design and progress in the implementation of the transport and monitoring system for an undulator based electron beam diagnostic. Miniature permanent-magnet quadrupoles (PMQs) are employed to realize controlled transport of the LPA electron beams, and cavity based electron beam position monitors for non-invasive beam position detection. Also presented is PMQ calibration by using LPA electron beams with broadband energy spectrum. The results show promising performance for both transporting and monitoring. With the proper transport system, XUV-photon spectra from THUNDER will provide the momentum distribution of the electron beam with the resolution above what can be achieved by the magnetic spectrometer currently used in the LOASIS facility.
Binary reactions at energies close to the Coulomb barrier received recently a significant boost thanks to the advent of the large solid angle magnetic spectrometer PRISMA coupled to the {gamma} array CLARA. In the present paper different aspects of recent results of nuclear structure and reaction dynamics will be presented, focusing more closely on the reaction mechanism, in particular on the properties of quasi-elastic and deep inelastic processes and on studies aiming at getting information on nucleon-nucleon correlations.
In this article, a newly constructed electron spectrometer of the magnetic bottle type is described. The instrument is part of an apparatus for measuring the electron spectra of free clusters using synchrotron radiation. Argon and helium outer valence photoelectron spectra have been recorded in order to investigate the characteristic features of the spectrometer. The energy resolution (E/{Delta}E) has been found to be {approx}30. Using electrostatic retardation of the electrons, it can be increased to at least 110. The transmission as a function of kinetic energy is flat, and is not impaired much by retardation with up to 80% of the initial kinetic energy. We have measured a detection efficiency of most probably 0.6{sub -0.1}{sup +0.05}, but at least of 0.4. Results from testing the alignment of the magnet, and from trajectory simulations, are also discussed.
It has been shown that the ({sup 3}He,t) charge exchange reaction at intermediate energies, used at zero momentum transfer in combination with high-resolution magnetic spectrometers is a very powerful probe for Gamow-Teller strengths. Several N = Z nuclei such as {sup 46}V or {sup 50}Mn have been investigated. Recently ab-initio nuclear structure calculations have become possible for light nuclei. Thus experimental studies on light nuclei have become of great current interest. We review previous results obtained in {sup 11}C with respect to nuclear structure aspects and the Hoyle state, and present some early results of a {sup 9}Be({sup 3}He,t){sup 9}B experiment carried out recently, pointing out the significance of high-resolution charge-exchange reactions and the investigation of Gamow-Teller strengths for the understanding of nuclear structure in light nuclei.
The main physics program of the International Linear Collider requires a measurement of the beam energy with a relative precision of the order 10{sup 4} or better. A magnetic spectrometer using high resolution beam position monitors (BPMs) has been proposed to achieve this goal. A prototype spectrometer chicane employing four dipole magnets is currently under development at the End Station A in SLAC, intending to demonstrate the required resolution and stability of this method and investigate possible systematic effects and operational issues. This contribution reports on the successful commissioning of the beam position monitor system and the resolution and stability achieved. Also, the initial results from a run with a full spectrometer chicane are presented.
Using high-energy (∼0.5 GeV) electron beams generated by laser wakefield acceleration (LWFA), bremsstrahlung radiation was created by interacting these beams with various solid targets. Secondary processes generate high-energy electrons, positrons, and neutrons, which can be measured shot-to-shot using magnetic spectrometers, short half-life activation, and Compton scattering. Presented here are proof-of-principle results from a high-resolution, high-energy gamma-ray spectrometer capable of single-shot operation, and high repetition rate activation diagnostics. We describe the techniques used in these measurements and their potential applications in diagnosing LWFA electron beams and measuring high-energy radiation from laser-plasma interactions.
In the spring of 2010, the Alpha Magnetic Spectrometer 2 (AMS-02) underwent a series of system level electromagnetic interference control measurements, followed by thermal vacuum testing. Shortly after completion of the thermal vacuum testing, the project decided to remove the cryogenically cooled superconducting magnet, and replace it with the original permanent magnet design employed in the earlier AMS- 01 assembly. Doing so necessitated several structural changes, as well as removal or modification of numerous electronic and thermal control devices and systems. At this stage, the project was rapidly approaching key milestone dates for hardware completion and delivery for launch, and had little time for additional testing or assessment of any impact to the electromagnetic signature of the AMS-02. Therefore, an analytical assessment of the radiated emissions behavioural changes associated with the system changes was requested.
The main physics program of the International Linear Collider (ILC) requires a measurement of the beam energy at the interaction point with an accuracy of 10{sup -4} or better. To achieve this goal a magnetic spectrometer using high resolution beam position monitors (BPMs) has been proposed. This paper reports on the cavity BPM system that was deployed to test this proposal. We demonstrate sub-micron resolution and micron level stability over 20 hours for a 1 m long BPM triplet. We find micron-level stability over 1 hour for 3 BPM stations distributed over a 30 m long baseline. The understanding of the behavior and response of the BPMs gained from this work has allowed full spectrometer tests to be carried out.
A method to calibrate measurement instruments through the fulfillment of physical laws is described. This method is particularly well suited to determine and/or improve magnetic spectrometer optics databases as well as to establish the best resolution achievable with them. Here, this method was applied to obtain the best resolution achievable in the excitation and binding energy spectra of several hypernuclei produced in the experiment E94-107 performed at JLab, allowing us to obtain sub-MeV resolutions.
The radial spread of charged particles emitted from a point source in a magnetic field is a potential source of systematic error for any experiment where magnetic fields guide charged particles to detectors with finite size. Assuming uniform probability as a function of the phase along the particle’s helical trajectory, an analytic solution for the radial probability distribution function follows which applies to experiments in which particles are generated throughout a volume that spans a sufficient length along the axis of a homogeneous magnetic field. This approach leads to the same result as a different derivation given by Dubbers et al., Nucl. Instrum. Methods Phys. Res., Sect. A 763, 112–119 (2014). But the constant phase approximation does not strictly apply to finite source volumes or fixed positions, which lead to local maxima in the radial distribution of emitted particles at the plane of the detector. A simple method is given to calculate such distributions, then the effect is demonstrated with data from a {sup 207}Bi electron-conversion source in the superconducting solenoid magnet spectrometer of the Ultracold Neutron facility at the Los Alamos Neutron Science Center. Implications for neutron beta decay spectroscopy are discussed.
The pointing instability of energetic electron beams generated from a laser-driven accelerator can cause a serious error in measuring the electron spectrum with a magnetic spectrometer. In order to determine a correct electron spectrum, the pointing angle of an electron beam incident on the spectrometer should be exactly defined. Here, we present a method for absolutely calibrating the electron spectrum by monitoring the pointing angle using a scintillating screen installed in front of a permanent dipole magnet. The ambiguous electron energy due to the pointing instability is corrected by the numerical and analytical calculations based on the relativistic equation of electron motion. It is also possible to estimate the energy spread of the electron beam and determine the energy resolution of the spectrometer using the beam divergence angle that is simultaneously measured on the screen. The calibration method with direct measurement of the spatial profile of an incident electron beam has a simple experimental layout and presents the full range of spatial and spectral information of the electron beams with energies of multi-hundred MeV level, despite the limited energy resolution of the simple electron spectrometer.
A compact and portable gamma-ray spectrometer has been designed to diagnose different components of the inertial confinement fusion-relevant γ-ray spectrum with energies between ∼3.7–17.9 MeV. The system is designed to be as compact as possible for convenient transportation and fielding in diagnostic ports on the OMEGA laser, the National Ignition Facility, and other photon-source facilities. The system consists of a conversion foil for Compton scattering in front of four magnetic spectrometer “arms,” each covering a different energy range and constructed out of cylindrical permanent magnet Halbach arrays. Monte Carlo simulations have been used to optimize and assess the performance of the conversion foil, and COSY INFINITY ion-optical simulations have been used to optimize the spectrometer magnets. The performance of the design is assessed for a simulated direct-drive γ-ray spectrum. Spanning its total γ-ray energy bandwidth and using a 1.7 mm thick boron conversion foil, the system’s total energy resolution and efficiency are ∼15.8%–4.5% and 5.4 × 10−7–3.7 × 10−7e−/γ, respectively, with room for improvement. Spectral γ-ray measurements will provide guidance to the inertial confinement fusion program toward achieving high-energy gain relevant to inertial fusion energy and enable new measurement capabilities for basic discovery science.