Wear Testing of the HERMeS Thruster

The Hall-Effect Rocket with Magnetic Shielding (HERMeS) thruster is being developed and tested at NASA GRC and NASA JPL through support of the Space Technology Mission Directorate (STMD) as primary propulsion for the Asteroid Redirect Robotic Mission (ARRM). This thruster is advancing the state-of-the-art of Hall-effect thrusters and is intended to serve as a precursor to higher power systems for human interplanetary exploration. A 2000-hour wear test has been initiated at NASA GRC with the HERMeS Technology Demonstration Unit One and three of four test segments have been completed totaling 728 h of operation. This is the first test of a NASA-designed magnetically shielded thruster to extend beyond 300 hr of continuous operation. Trends in performance, component wear, thermal design, plume properties, and back-sputtered deposition are discussed for two wear-test segments of 246 h and 360 h. The first incorporated graphite pole covers in an electrical configuration where cathode was electrically connected to thruster body. The second utilized traditional alumina pole covers with the thruster body floating. It was shown that the magnetic shielding in both configurations completely eliminated erosion of the boron nitride discharge channel but resulted in erosion of the inner pole cover. The volumetric erosion rate of the graphite pole covers was roughly 2/3 that of the alumina pole covers and the thruster exhibited slightly better performance. Buildup of back-sputtered carbon on the BN channel at a rate of roughly 1.5 μm/kh is shown to have negligible impact on the performance.

Thruster↗

A novel electron gun for inline MRI-linac configurations

Purpose: This work introduces a new electron gun geometry capable of robust functioning in the presence of a high strength external magnetic field for axisymmetric magnetic resonance imaging (MRI)-linac configurations. This allows an inline MRI-linac to operate without the need to isolate the linear accelerator (linac) using a magnetic shield. This MRI-linac integration approach not only leaves the magnet homogeneity unchanged but also provides the linac flexibility to move along the magnet axis of symmetry if the source to target distance needs to be adjusted. Methods: Simple electron gun geometry modifications of a Varian 600C electron gun are considered and solved in the presence of an external magnetic field in order to determine a set of design principles for the new geometry. Based on these results, a new gun geometry is proposed and optimized in the fringe field of a 0.5 T open bore MRI magnet (GE Signa SP). A computer model for the 6 MeV Varian 600C linac is used to determine the capture efficiency of the new electron gun-linac system in the presence of the fringe field of the same MRI scanner. The behavior of the new electron gun plus the linac system is also studied in the fringe fields of two other magnets, a 1.0 T prototype open bore magnet and a 1.5 T GE Conquest scanner. Results: Simple geometrical modifications of the original electron gun geometry do not provide feasible solutions. However, these tests show that a smaller transverse cathode diameter with a flat surface and a slightly larger anode diameter could alleviate the current loss due to beam interactions with the anode in the presence of magnetic fields. Based on these findings, an initial geometry resembling a parallel plate capacitor with a hole in the anode is proposed. The optimization procedure finds a cathode-anode distance of 5 mm, a focusing electrode angle of 5°, and an anode drift tube length of 17.1 mm. Also, the linac can be displaced with ±15 cm along the axis of the 0.5 T magnet without capture efficiency reduction below the experimental value in zero field. In this range of linac displacements, the electron beam generated by the new gun geometry is more effectively injected into the linac in the presence of an external magnetic field, resulting in approximately 20% increase of the target current compared to the original gun geometry behavior at zero field. The new gun geometry can generate and accelerate electron beams in external magnetic fields without current loss for fields higher than 0.11 T. The new electron-gun geometry is robust enough to function in the fringe fields of the other two magnets with a target current loss of no more than 16% with respect to the current obtained with no external magnetic fields. Conclusions: In this work, a specially designed electron gun was presented which can operate in the presence of axisymmetric strong magnetic fringe fields of MRI magnets. Computer simulations show that the electron gun can produce high quality beams which can be injected into a straight through linac such as Varian 600C and accelerated with more efficiency in the presence of the external magnetic fields. Also, the new configuration allows linac displacements along the magnet axis in a range equal to the diameter of the imaging spherical volume of the magnet under consideration. The new electron gun-linac system can function in the fringe field of a MRI magnet if the field strength at the cathode position is higher than 0.11 T. The capture efficiency of the linac depends on the magnetic field strength and the field gradient. The higher the gradient the better the capture efficiency. The capture efficiency does not degrade more than 16%.

43 PARTICLE ACCELERATORS↗

Communication: Permanent dipoles contribute to electric polarization in chiral NMR spectra

Nuclear magnetic resonance spectroscopy is blind to chirality because the spectra of a molecule and its mirror image are identical unless the environment is chiral. However, precessing nuclear magnetic moments in chiral molecules in a strong magnetic field induce an electric polarization through the nuclear magnetic shielding polarizability. This effect is equal and opposite for a molecule and its mirror image but is small and has not yet been observed. It is shown that the permanent electric dipole moment of a chiral molecule is partially oriented through the antisymmetric part of the nuclear magnetic shielding tensor, causing the electric dipole to precess with the nuclear magnetic moment and producing a much larger temperature-dependent electric polarization with better prospects of detection.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The Magnetic and Shielding Effects of Ring Current on Radiation Belt Dynamics

The ring current plays many key roles in controlling magnetospheric dynamics. A well-known example is the magnetic depression produced by the ring current, which alters the drift paths of radiation belt electrons and may cause significant electron flux dropout. Little attention is paid to the ring current shielding effect on radiation belt dynamics. A recent simulation study that combines the Comprehensive Ring Current Model (CRCM) with the Radiation Belt Environment (RBE) model has revealed that the ring current-associated shielding field directly and/or indirectly weakens the relativistic electron flux increase during magnetic storms. In this talk, we will discuss how ring current magnetic field and electric shielding moderate the radiation belt enhancement.

Fok, Mei-Ching↗

Efficient calculation of nuclear spin-rotation constants from auxiliary density functional theory

The computation of the spin-rotation tensor within the framework of auxiliary density functional theory (ADFT) in combination with the gauge including atomic orbital (GIAO) scheme, to treat the gauge origin problem, is presented. For the spin-rotation tensor, the calculation of the magnetic shielding tensor represents the most demanding computational task. Employing the ADFT-GIAO methodology, the central processing unit time for the magnetic shielding tensor calculation can be dramatically reduced. In this work, the quality of spin-rotation constants obtained with the ADFT-GIAO methodology is compared with available experimental data as well as with other theoretical results at the Hartree-Fock and coupled-cluster level of theory. It is found that the agreement between the ADFT-GIAO results and the experiment is good and very similar to the ones obtained by the coupled-cluster single-doubles-perturbative triples-GIAO methodology. With the improved computational performance achieved, the computation of the spin-rotation tensors of large systems or along Born-Oppenheimer molecular dynamics trajectories becomes feasible in reasonable times. Three models of carbon fullerenes containing hundreds of atoms and thousands of basis functions are used for benchmarking the performance. Furthermore, a theoretical study of temperature effects on the structure and spin-rotation tensor of the H{sup 12}C–{sup 12}CH–DF complex is presented. Here, the temperature dependency of the spin-rotation tensor of the fluorine nucleus can be used to identify experimentally the so far unknown bent isomer of this complex. To the best of our knowledge this is the first time that temperature effects on the spin-rotation tensor are investigated.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

WE-G-BRD-09: Novel MRI Compatible Electron Accelerator for MRI-Linac Radiotherapy

Purpose: MRI guided radiotherapy is a rapidly growing field; however current linacs are not designed to operate in MRI fringe fields. As such, current MRI- Linac systems require magnetic shielding, impairing MR image quality and system flexibility. Here, we present a bespoke electron accelerator concept with robust operation in in-line magnetic fields. Methods: For in-line MRI-Linac systems, electron gun performance is the major constraint on accelerator performance. To overcome this, we propose placing a cathode directly within the first accelerating cavity. Such a configuration is used extensively in high energy particle physics, but not previously for radiotherapy. Benchmarked computational modelling (CST, Darmstadt, Germany) was employed to design and assess a 5.5 cell side coupled accelerator with a temperature limited thermionic cathode in the first accelerating cell. This simulation was coupled to magnetic fields from a 1T MRI model to assess robustness in magnetic fields for Source to Isocenter Distance between 1 and 2 meters. Performance was compared to a conventional electron gun based system in the same magnetic field. Results: A temperature limited cathode (work function 1.8eV, temperature 1245K, emission constant 60A/K/cm{sup 2}) will emit a mean current density of 24mA/mm{sup 2} (Richardson’s Law). We modeled a circular cathode with radius 2mm and mean current 300mA. Capture efficiency of the device was 43%, resulting in target current of 130 mA. The electron beam had a FWHM of 0.2mm, and mean energy of 5.9MeV (interquartile spread of 0.1MeV). Such an electron beam is suitable for radiotherapy, comparing favourably to conventional systems. This model was robust to operation the MRI fringe field, with a maximum current loss of 6% compared to 85% for the conventional system. Conclusion: The bespoke electron accelerator is robust to operation in in-line magnetic fields. This will enable MRI-Linacs with no accelerator magnetic shielding, and minimise painstaking optimisation of the MRI fringe field. This work was supported by US (NIH) and Australian (NHMRC & Cancer Institute NSW) government research funding. In addition, I would like to thank cancer institute NSW and the Ingham Institute for scholarship support.

60 APPLIED LIFE SCIENCES↗

Influence of the Earth's magnetic field on large area photomultipliers

The influence of the Earth's magnetic field on large area photomultipliers proposed for a future deep sea neutrino telescope was studied under the EU-funded KM3NeT design study. The aims were to evaluate variations in PMT performance in the Earth's magnetic field and to decide whether the use of magnetic shielding is necessary. Measurements were performed on three Hamamatsu PMTs: two 8-inch R5912 types, one of these with super-bi-alkali photocathode, and a 10-inch R7081 type with a standard bi-alkali photocathode. The various characteristics of the PMTs were measured while varying the PMT orientations with respect to the Earth's magnetic field, both with and without a mu-metal cage as magnetic shield. In the 8-inch PMTs the impact of the magnetic field was found to be smaller than that on the 10-inch PMT. The increased quantum efficiency in the 8 super-bi-alkali PMT almost compensated its smaller detection surface compared to the 10' PMT. No significant effects were measured upon transit time and the fraction of spurious pulses. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Reduced-order simulation of large accelerator structures

Simulating electromagnetic waves inside finite periodic or almost periodic three-dimensional structures is important to research in linear particle acceleration, high power microwave generation, and photonic band gap structures. While eigenmodes of periodic structures can be determined from analysis of a single unit cell, based on Floquet theory, the general case of aperiodic structures, with defects or nonuniform properties, typically requires 3D electromagnetic simulation of the entire structure. When the structure is large and high accuracy is necessary this can require high-performance computing techniques to obtain even a few eigenmodes [Z. Li et al., Nucl. Instrum. Methods Phys. Res., Sect. A 558, 168 (2006)]. To confront this problem, we describe an efficient, field-based algorithm that can accurately determine the complete eigenmode spectrum for extended aperiodic structures, up to some chosen frequency limit. The new method combines domain decomposition with a nontraditional, dual eigenmode representation of the fields local to each cell of the structure. Two related boundary value eigenproblems are solved numerically in each cell, with (a) electrically shielded, and (b) magnetically shielded interfaces, to determine a combined set of basis fields. By using the dual solutions in our field representation we accurately represent both the electric and magnetic surface currents that mediate coupling at the interfaces between adjacent cells. The solution is uniformly convergent, so that typically only a few modes are used in each cell. We present results from 2D and 3D simulations that demonstrate the speed and low computational needs of the algorithm.

43 PARTICLE ACCELERATORS↗

A study of the effect of in-line and perpendicular magnetic fields on beam characteristics of electron guns in medical linear accelerators

Purpose: Using magnetic resonance imaging (MRI) for real-time guidance during radiotherapy is an active area of research and development. One aspect of the problem is the influence of the MRI scanner, modeled here as an external magnetic field, on the medical linear accelerator (linac) components. The present work characterizes the behavior of two medical linac electron guns with external magnetic fields for in-line and perpendicular orientations of the linac with respect to the MRI scanner. Methods: Two electron guns, Litton L-2087 and Varian VTC6364, are considered as representative models for this study. Emphasis was placed on the in-line design approach in which case the MRI scanner and the linac axes of symmetry coincide and assumes no magnetic shielding of the linac. For the in-line case, the magnetic field from a 0.5 T open MRI (GE Signa SP) magnet with a 60 cm gap between its poles was computed and used in full three dimensional (3D) space charge simulations, whereas for the perpendicular case the magnetic field was constant. Results: For the in-line configuration, it is shown that the electron beam is not deflected from the axis of symmetry of the gun and the primary beam current does not vanish even at very high values of the magnetic field, e.g., 0.16 T. As the field strength increases, the primary beam current has an initial plateau of constant value after which its value decreases to a minimum corresponding to a field strength of approximately 0.06 T. After the minimum is reached, the current starts to increase slowly. For the case when the beam current computation is performed at the beam waist position the initial plateau ends at 0.016 T for Litton L-2087 and at 0.012 T for Varian VTC6364. The minimum value of the primary beam current is 27.5% of the initial value for Litton L-2087 and 22.9% of the initial value for Varian VTC6364. The minimum current is reached at 0.06 and 0.062 T for Litton L-2087 and Varian VTC6364, respectively. At 0.16 T the beam current increases to 40.2 and 31.4% from the original value of the current for Litton L-2087 and Varian VTC6364, respectively. In contrast, for the case when the electron gun is perpendicular to the magnetic field, the electron beam is deflected from the axis of symmetry even at small values of the magnetic field. As the strength of the magnetic field increases, so does the beam deflection, leading to a sharp decrease of the primary beam current which vanishes at about 0.007 T for Litton L-2087 and at 0.006 T for Varian VTC6364, respectively. At zero external field, the beam rms emittance computed at beam waist is 1.54 and 1.29{pi}-mm-mrad for Litton L-2087 and Varian VTC6364, respectively. For the in-line configuration, there are two particular values of the external field where the beam rms emittance reaches a minimum. Litton L-2087 rms emittance reaches a minimum of 0.72{pi} and 2.01{pi}-mm-mrad at 0.026 and 0.132 T, respectively. Varian VTC6364 rms emittance reaches a minimum of 0.34{pi} and 0.35{pi}-mm-mrad at 0.028 and 0.14 T, respectively. Beam radius dependence on the external field is shown for the in-line configuration for both electron guns. Conclusions: 3D space charge simulation of two electron guns, Litton L-2087 and Varian VTC6364, were performed for in-line and perpendicular external magnetic fields. A consistent behavior of Pierce guns in external magnetic fields was proven. For the in-line configuration, the primary beam current does not vanish but a large reduction of beam current (up to 77.1%) is observed at higher field strengths; the beam directionality remains unchanged. It was shown that for a perpendicular configuration the current vanishes due to beam bending under the action of the Lorentz force. For in-line configuration it was determined that the rms beam emittance reaches two minima for relatively high values of the external magnetic field.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Search for a permanent electric dipole moment using liquid 129Xe

Search for an electric dipole moment is one of the best motivated low-energy approaches for investigating physics beyond the Standard Model. Our experimental effort is focused on improving the limit on EDM in liquid 129Xe to put constraints on nuclear CP-violating interactions. High nuclear spin density and high electrical breakdown strength make 129Xe a promising medium for EDM searches. At the time the project started, the transverse nuclear spin relaxation time T2 of 129Xe was unknown. We made measurements of T2 using NMR spin-echo techniques and found that it is exceeds 1300 sec, the longest relaxation time ever measured in a liquid [1]. We also began to investigate non-linear dipolar interaction effects in a high-density spin-polarized liquid Xe. In the second iteration of the experiment we setup a high-Tc SQUID system in magnetic shields and performed detailed studies of Xe spin precession. We developed a model for non-linear dipolar interactions and found that for one set of conditions non-linear interactions can delay spin dephasing due to magnetic field gradients, while for another set of conditions they can lead to exponential amplification of the spin precession signals [2]. Our experimental data were in good quantitative agreement with predictions of the model. We also developed a series of numerical simulations to understand various imperfections in the system and made detailed experimental measurements to confirm these numerical predictions [3]. We demonstrated that non-linear interactions can amplify small precession signals and achieved an amplification factor of 10 [4]. This general phenomenon can be used in other precision measurements with non-linear interactions. We also explored practical applications of the liquid Xe system that we developed. We demonstrated that by mixing Xe with organic liquids, such as cyclopentane, one can enhance the proton spin polarization by a factor of 106 [5]. We have used this technique to perform the first measurement of the scalar J-coupling between nuclear spins in van-der-Waals molecules, something that has never been observed before. More recently, we constructed a liquid-He apparatus to acquire Xe spin precession data using a low-Tc SQUID and achieved a signal-to-noise ratio of 106. We are currently investigating factors affecting the stability of Xe spin precession signals in this system using a superconducting magnetic shield and a persistent current magnetic field coil.

74 ATOMIC AND MOLECULAR PHYSICS↗

NGHT-1X Pole Cover Erosion Measurements on Xenon and Krypton

Northrop Grumman’s NGHT-1X Hall thruster has completed the Engineering Model development phase and is progressing towards qualification and flight unit build and test. First flight of the NGHT-1X will occur in 2025 on Northrop Grumman’s Mission Extension Pod spacecraft. The NGHT-1X is a state of the art 1 kW-class Hall thruster which implements magnetic shielding to increase thruster lifetime by reducing discharge channel wall erosion. As a result, like other magnetically shielded Hall thrusters, the NGHT-1X exhibits erosion of the front-facing pole covers, which is the primary life-limiting failure mode of the thruster. During the development of the NGHT-1X, several Short Duration Wear Tests were performed to characterize erosion rates and forecast compliance to lifetime requirements in advance of the ongoing full-life Long Duration Wear Test. Erosion rate measurements from four tests at different operating conditions are presented and comparisons made between tests. Two tests were performed in the same background pressure environment at 700 W 300 V and 900 W 350 V throttle conditions, both using xenon propellant. A third test was performed again at 900 W 350 V with xenon propellant, but at a lower background pressure. Lastly, to assess the viability of potential future applications with alternate propellants, a wear test was conducted using krypton propellant at 900 W 250 V, the results of which are presented here. The erosion measurements from each test are compared with one another, and insights are discussed. All xenon wear tests support a thruster lifetime capability in excess of 16,000 hours, or 3.3 MNs at 900 W 350 V, which supports the Mission Extension Pod mission with margin as well as many other potential applications on small- to medium-sized spacecraft.

Hall↗

280 GHz Focal Plane Unit Design and Characterization for the Spider-2 Suborbital Polarimeter

We describe the construction and characterization of the 280 GHz bolometric focal plane units (FPUs) to be deployed on the second flight of the balloon-borne Spider instrument. These FPUs are vital to Spider’s primary science goal of detecting or placing an upper limit on the amplitude of the primordial gravitational wave signature in the cosmic microwave background (CMB) by constraining the B-mode contamination in the CMB from Galactic dust emission. Each 280 GHz focal plane contains a $16 \times 16$ grid of corrugated silicon feedhorns coupled to an array of aluminum–manganese transition-edge sensor (TES) bolometers fabricated on 150 mm diameter substrates. In total, the three 280 GHz FPUs contain 1530 polarization-sensitive bolometers (765 spatial pixels) optimized for the low loading environment in flight and read out by time-division SQUID multiplexing. In this paper, we describe the mechanical, thermal, and magnetic shielding architecture of the focal planes and present cryogenic measurements which characterize yield and the uniformity of several bolometer parameters. The assembled FPUs have high yields, with one array as high as 95% including defects from wiring and readout. We demonstrate high uniformity in device parameters, finding the median saturation power for each TES array to be $\sim $ 3 pW at 300 mK with a less than 6% variation across each array at $1\sigma $ . These focal planes will be deployed alongside the 95 and 150 GHz telescopes in the Spider-2 instrument, slated to fly from McMurdo Station in Antarctica in December 2018.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

HERMeS Thruster Magnetic Field Topology Optimization Study: Performance, Stability, and Wear Results

NASA's Hall Effect Rocket with Magnetic Shielding (HERMeS) 12.5kW Technology Demonstration Unit-1 (TDU-1) has been the subject of extensive technology maturation in preparation for flight system development. The TDU-1 thruster implements a magnetically shielded field topology and has demonstrated the elimination of the discharge channel erosion as a life limiting mechanism. Extensive wear testing the TDU Hall thrusters has identified the thruster front pole covers as the next life limiting component. This effort aims to explore and investigate alternate magnetic field topologies to assess whether reductions in the front pole cover erosion can be attained while still maintaining very low erosion rates on the discharge channel walls. Four candidate magnetic field topologies that reduce the effectiveness of the shielding along the discharge channel walls with the intent to also reduce the erosion rates along the front pole covers were designed. Three of the four candidate magnetic field topologies (B1, B2, and B4) have been manufactured and were subjected to an extensive test campaign that includes laser induced fluorescence (LIF), performance, stability, wear, plume, and thermal characterization. In Phase I, LIF measurements along the discharge chamber centerline found that upstream retraction of the thruster's peak magnetic field does result in an upstream shift of the acceleration zone but the magnitude of the shift does not correspond one-to-one to the shift in the location of the peak radial magnetic field magnitude. Phase II test segment results found at a normalized thruster magnetic field setting of 1, the thruster performance was very similar for all configurations. Discharge current waveforms ripple data indicated that configurations Bo, B1, and B2 has similar oscillatory profiles with the B2 configuration transitioning to higher oscillatory mode at 400V instead of the 450V observed for configurations B0 and B1. Configuration B4 ripple data indicates that the thruster was operating in a very oscillatory mode above 350V. Inner front pole cover erosion rates for configuration B1 were approximately 65% relative to B0 and the erosion rates for configuration B2 were 40% relative to B0. Analysis of the performance, stability, and wear test results of configurations B0, B1, B2, and B4 indicates that configuration B2 may present an alternative option for B0 because it mostly maintained the same performance and stability as configuration B0 but with 40% of the inner front pole cover erosion rate.

Kamhawi, Hani↗

A magnetic shield/dual purpose mission

The objective of this work is to design, build, and fly a dual-purpose payload whose function is to produce a large volume, low intensity magnetic field and to test the concept of using such a magnetic field to protect manned spacecraft against particle radiation. An additional mission objective is to study the effect of this moving field on upper atmosphere plasmas. Both mission objectives appear to be capable of being tested using the same superconducting coil. The potential benefits of this magnetic shield concept apply directly to both earth-orbital and interplanetary missions. This payload would be a first step in assessing the true potential of large volume magnetic fields in the U.S. space program. Either converted launch systems or piggyback payload opportunities may be appropriate for this mission. The use of superconducting coils for magnetic shielding against solar flare radiation during manned interplanetary missions has long been contemplated and was considered in detail in the years preceding the Apollo mission. With the advent of new superconductors, it has now become realistic to reconsider this concept for a Mars mission. Even in near-earth orbits, large volume magnetic fields produced using conventional metallic superconductors allow novel plasma physics experiments to be contemplated. Both deployed field-coil and non-deployed field-coil shielding arrangements have been investigated, with the latter being most suitable for an initial test payload in a polar orbit.

Watkins, Seth↗

Metallic Wall Hall Thrusters

A Hall thruster apparatus having walls constructed from a conductive material, such as graphite, and having magnetic shielding of the walls from the ionized plasma has been demonstrated to operate with nearly the same efficiency as a conventional non-magnetically shielded design using insulators as wall components. The new design is believed to provide the potential of higher power and uniform operation over the operating life of a thruster device.

Goebel, Dan Michael↗

Non-Intrusive Characterization of the Wear of the HERMeS Thruster Using Optical Emission Spectroscopy

The Hall Effect Rocket with Magnetic Shielding (HERMeS) is a 12.5 kW Hall thrusterelectric propulsion string that has been in development by NASA Glenn Research Center(GRC) and NASA JPL since 2012. Due to the magnetically shielded design, service life-limiting erosion of the boron nitride discharge has been virtually eliminated. The innerfront pole cover (IFPC) has now been identied as the component dening erosion-basedservice life. Optical emission spectroscopy (OES) is used as an in-situ diagnostic to measurerelative erosion trends during operation of the HERMeS thruster during a series of shortduration wear tests. Erosion trends obtained from the OES data will be compared totraditional erosion data measured with a non-contact prolometer.

hall thruster↗