Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MAGNETIC INSTRUMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Itinerancy enhanced quantum fluctuation of magnetic moments in iron-based superconductors

We investigate the influence of itinerant carriers on dynamics and fluctuation of local moments in Fe-based superconductors, via linear spin-wave analysis of a spin-fermion model containing both itinerant and local degrees of freedom. Surprisingly against the common lore, instead of enhancing the (π,0) order, itinerant carriers with well nested Fermi surfaces is found to induce significant amount of spatial and temporal quantum fluctuation that leads to the observed small ordered moment. Interestingly, the underlying mechanism is shown to be intra-pocket nesting-associated long-range coupling, rather than the previously believed ferromagnetic double-exchange effect. This challenges the validity of ferromagnetically compensated first-neighbor coupling reported from short-range fitting to the experimental dispersion, which turns out to result instead from the ferro-orbital order that is also found instrumental in stabilizing the magnetic order.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Calibration of two compact permanent magnet spectrometers for high current electron linear induction accelerators

In this work, two compact, permanent magnet, electron spectrometers have been built to measure the electron beam energy at the Dual Axis Radiographic Hydrodynamic Test facility. Using H - and OH - anions, the spectrometers were calibrated at the Special Technologies Laboratory in Santa Barbara, California (USA). The spectrometers were mounted on a custom drift tube that allows the magnet assemblies to be translated, which increases the path length of the electrons traveling through the magnetic field and therefore increases the upper bound of the measurable electron kinetic energy. The measurable range of electron kinetic energies is between 2.8 MeV–4.1 MeV for the first spectrometer and 14.1 MeV–21.1 MeV for the second spectrometer, with an overall measurement uncertainty of 0.32%.

47 OTHER INSTRUMENTATION↗

Tracking Efficiency And Charge Sharing of 3D Silicon Sensors at Different Angles in a 1.4T Magnetic Field

A 3D silicon sensor fabricated at Stanford with electrodes penetrating throughout the entire silicon wafer and with active edges was tested in a 1.4 T magnetic field with a 180 GeV/c pion beam at the CERN SPS in May 2009. The device under test was bump-bonded to the ATLAS pixel FE-I3 readout electronics chip. Three readout electrodes were used to cover the 400 {micro}m long pixel side, this resulting in a p-n inter-electrode distance of {approx} 71 {micro}m. Its behavior was confronted with a planar sensor of the type presently installed in the ATLAS inner tracker. Time over threshold, charge sharing and tracking efficiency data were collected at zero and 15{sup o} angles with and without magnetic field. The latest is the angular configuration expected for the modules of the Insertable B-Layer (IBL) currently under study for the LHC phase 1 upgrade expected in 2014.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quantum transport in coupled resonators enclosed synthetic magnetic flux

Quantum transport properties are instrumental to understanding quantum coherent transport processes. Potential applications of quantum transport are widespread, in areas ranging from quantum information science to quantum engineering, and not restricted to quantum state transfer, control and manipulation. Here, we study light transport in a ring array of coupled resonators enclosed synthetic magnetic flux. The ring configuration, with an arbitrary number of resonators embedded, forms a two-arm Aharonov–Bohm interferometer. The influence of magnetic flux on light transport is investigated. Tuning the magnetic flux can lead to resonant transmission, while half-integer magnetic flux quantum leads to completely destructive interference and transmission zeros in an interferometer with two equal arms. -- Highlights: •The light transport is investigated through ring array of coupled resonators enclosed synthetic magnetic field. •Aharonov–Bohm ring interferometer of arbitrary configuration is investigated. •The half-integer magnetic flux quantum leads to destructive interference and transmission zeros for two-arm at equal length. •Complete transmission is available via tuning synthetic magnetic flux.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

One dimensional imager of neutrons on the Z machine

We recently developed a one-dimensional imager of neutrons on the Z facility. The instrument is designed for Magnetized Liner Inertial Fusion (MagLIF) experiments, which produce D-D neutrons yields of ~3 × 10 12 . X-ray imaging indicates that the MagLIF stagnation region is a 10-mm long, ~100-μm diameter column. The small radial extents and present yields precluded useful radial resolution, so a one-dimensional imager was developed. The imaging component is a 100-mm thick tungsten slit; a rolled-edge slit limits variations in the acceptance angle along the source. CR39 was chosen as a detector due to its negligible sensitivity to the bright x-ray environment in Z. A layer of high density poly-ethylene is used to enhance the sensitivity of CR39. Finally, we present data from fielding the instrument on Z, demonstrating reliable imaging and track densities consistent with diagnosed yields. For yields ~3 × 10 12 , we obtain resolutions of ~500 μm.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Metastability exchange optical pumping of 3 He at low pressure and high magnetic field

We report systematic studies on metastability exchange optical pumping of 3 He nuclei have been performed at Jefferson Lab using a 1-torr sealed cell at magnetic fields from 2 to 4 T. The effects of the discharge intensity, pump laser power and pumping transition schemes on achievable nuclear polarization and pumping rate have been investigated. A maximum steady-state nuclear polarization of about 75% has been obtained. This work provides a baseline for the development of the novel polarized 3 He target for CLAS12 at Jefferson Lab.

47 OTHER INSTRUMENTATION↗

Central ion cyclotron emission in the DIII-D tokamak

Collective ion cyclotron emission (ICE) at the ion cyclotron frequency and its harmonics is a potential passive diagnostic of the fast-ion distribution in fusion reactors. ICE is observed in most plasmas in the DIII-D tokamak and is most strongly excited by the fast ions from neutral beam injection. The conventional outboard-edge ICE is detected in H-mode plasmas. However, weaker centrally-localized ICE is measured in L-mode plasmas, including those with negative triangularity shapes. Similar ICE spectra are found with both ICE diagnostics systems, the dedicated magnetic probes and the instrumented antenna straps. Many differences in the behavior of this central ICE are generated by varying the deuterium beam injection angle into deuterium plasmas. The co-current 'near-perpendicular' beam excites the most central ICE from the co-current beams, with this emission detected from the fundamental to the fifth ICE harmonic. However, the counter-current 'near-tangential' beam destabilizes the highest amounts of centrally-localized ICE. This emission is spectrally broader than that driven by the co-current beams and is observed up to its seventh ICE harmonic. The central ICE excited by this co-current beam correlated strongly on the local electron density and related parameters (plasma current and neutron rate) and increased with deeper fast-ion loss boundaries towards the magnetic axis. This was also the case with second harmonic ICE driven by the counter-current beam but not with its stronger third harmonic emission. The central ICE harmonics destabilized by both beams are observed to have different temporal dynamics. The central ICE amplitude responds rapidly to transient MHD events; it dropped and recovered in less than a millisecond at each sawtooth event. ICE frequency splitting is triggered by both the co-current and counter-current 'near-tangential' beams. The data presented provide opportunities to test and validate models of excitation of ICE by energetic ions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Optimization and test of a 120mm LARP Nb3Sn quadrupole coil using magnetic mirror structure

The US-LARP collaboration is developing a new generation of large-aperture high-field quadrupoles based on Nb{sub 3}Sn superconductor for the LHC upgrades. The development and implementation of this new technology involves the fabrication and testing of series of model magnets, coils and other components with various design and processing features. New 120-mm HQ coils made of Rutherford cable, one with an interlayer resistive core, and both with optimized reaction processes, were fabricated and tested using a quadrupole mirror structure under operating conditions similar to those in a real magnet. The coils were instrumented with voltage taps and strain gauges to study the mechanical and quench performance. Quench antenna and temperature gauges were installed in the mirror structure to measure the coil temperature and locate quench origins. This paper presents details of the coil design and fabrication procedures, coil assembly and pre-stress in the quadrupole mirror structure, and coil test results.

43 PARTICLE ACCELERATORS↗

Estimating Electron Temperature and Density Using Van Allen Probe Data: Typical Behavior of Energetic Electrons in the Inner Magnetosphere

Abstract The Earth's inner magnetosphere contains multiple electron populations influenced by different factors. The cold electrons of the plasmasphere, warm plasma that contributes to the ring current, and the relativistic plasma of the radiation belts often seem to behave independently. Using omni‐directional flux and energy measurements from the HOPE and Magnetic Electron Ion Spectrometer instruments aboard the Van Allen Probes, we provide a detailed density and temperature description of the inner magnetosphere, offering a comprehensive statistical analysis of the entire Van Allen Probe era. While number density and temperature data at geosynchronous orbit are available, this study focuses on the warm plasma in the inner magnetosphere . Values of density and temperature are extracted by fitting energy and phase space density to obtain the distribution function. The fitted distributions are related to the zeroth and second moments to estimate the number density and temperature. Analysis has indicated that a two Maxwellian fit is sufficient over a wide range of and that there are two independent plasma populations. The more energetic population has a median number density of approximately and a temperature of around 130 keV, with a temperature peak observed between L * = 4 and L * = 4.5. This population is relatively uniform in magnetic local time (MLT). In contrast, the less energetic warm electron population has a median number density of about and a temperature of 7.4 keV. Strong statistical trends in density and temperature across both L * and MLT are presented, along with potential sources driving these variations.

58 GEOSCIENCES↗

Cryogenic goniometer for measurements in pulsed magnetic fields fabricated via additive manufacturing technique

Complex high-precision mechanical devices can be fabricated using 3-dimensional printing technology with the help of computer-aided design. Using 3D stereolithography, we have constructed a cryogenic goniometer for measurements in pulsed magnetic fields of up to 100 T, at temperatures as low as 0.5 K. We review the properties of several materials tested in developing the goniometer and report on its design and performance. The goniometer allows samples to be rotated in situ to a precision of 0.2 deg, so that the field can be applied at many different angles to the samples’ symmetry directions. Following its success, we establish that 3D printing is now a viable technology for pulsed-field and other cryogenic probes.

3D printing↗

Variable magnetic field electron spectrometer to measure hot electrons in the range of 50–460 keV

Resonance absorption (RA) occurs when a p-polarized electromagnetic wave, obliquely incident on an inhomogeneous plasma, tunnels past its turning point and resonantly excites an electron plasma wave (EPW) at the critical density. This phenomenon is important, for instance, in the direct drive approach to inertial fusion energy and is a particular example of a wider phenomenon in plasma physics known as mode conversion, which is crucial for heating magnetic fusion devices, such as tokamaks, via RF heating. Direct measurement of these RA-generated EPW accelerated hot electrons, with energy in the range of a few tens to a few hundreds of keV, is a challenging task due to the relatively low deflecting magnetic fields needed. The solution described here is a magnetic electron spectrometer (MES) with a continually changing magnetic field, lower at the entrance of the MES and gradually increasing toward the end, that enables the measurement of a wide spectral range of electrons with energies between 50 and 460 keV. Electron spectra taken in a LaserNetUS RA experiment were acquired from plasmas generated by irradiating polymer targets with the combination of an ~300 ps pulse followed by a series of ten high intensity 50–200 fs duration laser pulses from the ALEPH laser at Colorado State University. In conclusion, the high intensity beam is designed as spike trains of uneven duration and delay pulses in order to modify the RA phenomenon.

47 OTHER INSTRUMENTATION↗

Volume-selective magnetic resonance imaging using an adjustable, single-sided, portable sensor

Portable, single-sided NMR sensors can operate under conditions inaccessible to conventional NMR while featuring lower cost, portability, and the ability to analyze arbitrary-sized objects. Such sensors can nondestructively probe the interior of samples by collecting images and measuring relaxation and diffusion constants,and, given careful shimming schemes, even perform chemical analysis. The inherently strong magnetic-field gradients of single-sided sensors developed so far has prevented imaging of materials with high water content, such as biological tissues, over large volumes whereas designs with more homogeneous fields suffer from low field strength and typically cannot probe volumes larger than 10 cm3. We present a design with a continuously adjustable sensitive volume, enabling the effective volume to be enlarged several fold. This process allows for imaging in reasonable times of much bigger objects and opens the door to the possibility of clinical imaging with portable sensors. We demonstrate MRI in axial and saggital planes, at different depths of the sensitive volume and T1-weighted contrast in a tissue sample.

47 OTHER INSTRUMENTATION↗

Damping Ring R&D at CESR-TA

Accelerators that collide high energy beams of matter and anti-matter are essential tools for the investigation of the fundamental constituents of matter, and the search for new forms of matter and energy. A “Linear Collider” is a machine that would bring high energy and very compact bunches of electrons and positrons (anti-electrons) into head-on collision. Such a machine would produce (among many other things) the newly discovered Higgs particle, enabling a detailed study of its properties. Among the most critical and challenging components of a linear collider are the damping rings that produce the very compact and intense beams of electrons and positrons that are to be accelerated into collision. Hot dilute particle beams are injected into the damping rings, where they are compressed and cooled. The size of the positron beam must be reduced more than a thousand fold in the damping ring, and this compression must be accomplished in a fraction of a second. The cold compact beams are then extracted from the damping ring and accelerated into collision at high energy. The proposed International Linear Collider (ILC), would require damping rings that routinely produce such cold, compact and intense beams. The goal of the Cornell study was a credible design for the damping rings for the ILC. Among the technical challenges of the damping rings; the development of instrumentation that can measure the properties of the very small beams in a very narrow window of time, and mitigation of the forces that can destabilize the beams and prevent adequate cooling, or worse lead to beam loss. One of the most pernicious destabilizing forces is due to the formation of clouds of electrons in the beam pipe. The electron cloud effect is a phenomenon in particle accelerators in which a high density of low energy electrons, build up inside the vacuum chamber. At the outset of the study, it was anticipated that electron cloud effects would limit the intensity of the positron ring, and that an instability associated with residual gas in the beam pipe would limit the intensity of the electron ring. It was also not clear whether the required very small beam size could be achieved. The results of this study are important contributions to the design of both the electron and positron damping rings in which all of those challenges are addressed and overcome. Our findings are documented in the ILC Technical Design Report, a document that represents the work of an international collaboration of scientists. Our contributions include design of the beam magnetic optics for the 3 km circumference damping rings, the vacuum system and surface treatments for electron cloud mitigation, the design of the guide field magnets, design of the superconducting damping wigglers, and new detectors for precision measurement of beam properties. Our study informed the specification of the basic design parameters for the damping rings, including alignment tolerances, magnetic field errors, and instrumentation. We developed electron cloud modelling tools and simulations to aid in the interpretation of the measurements that we carried out in the Cornell Electron-positron Storage Ring (CESR). The simulations provide a means for systematic extrapolation of our measurements at CESR to the proposed ILC damping rings, and ultimately to specify how the beam pipes should be fabricated in order to minimize the effects of the electron cloud. With the conclusion of this study, the design of the essential components of the damping rings is complete, including the development and characterization (with computer simulations) of the beam optics, specification of techniques for minimizing beam size, design of damping ring instrumentation, R&D into electron cloud suppression methods, tests of long term durability of electron cloud coatings, and design of damping ring vacuum system components.

43 PARTICLE ACCELERATORS↗

Quantifying Background Magnetic Fields at Marine Energy Sites: Challenges and Recommendations

Unknowns around the environmental effects of marine renewable energy have slowed the deployment of this emerging technology worldwide. Established testing methods are necessary to safely permit and develop marine energy devices. Magnetic fields are one potential cause of environmental effects and are created when electricity is generated and transmitted to shore. Further, the existing variation of the background magnetic field at sites that may be developed for marine energy is largely unknown, making it difficult to assess how much additional stress or impact the anthropogenic magnetic field may have. This study investigates two instruments for their ability to characterize the background magnetic fields at a potential marine energy site in Sequim Bay, WA. Based on this evaluation, this study recommends an Overhauser magnetomer for assessing the background magnetic field and demonstrates the use of this sensor at a potential marine energy site.

47 OTHER INSTRUMENTATION↗

Diagnostic development for parallel wave-number measurement of lower hybrid waves in EAST

In this study, an eight-channel magnetic probe diagnostic system has been designed and installed adjacent to the 4.6 GHz lower hybrid (LH) grill antenna in the low-field side of the Experimental Advanced Superconducting Tokamak (EAST) in order to study the n ∥ evolution of LH waves in the first pass from the launcher to the core plasma. The magnetic probes are separated by 6.6 mm, which allows measurement of the dominant parallel refractive index n ∥ up to n ∥ = 5 for 4.6 GHz LH waves. The magnetic probes are designed to be sensitive to the magnetic field component perpendicular to the background magnetic field with a slit on the casing that encloses the probe. The intermediate frequency stage, which consists of two mixing stages, down-coverts the frequency of the measured wave signals at 4.6 GHz to 20 MHz. A bench test demonstrates the phase stability of the magnetic probe diagnostic system. By evaluating the phase variation of the measured signals along the background magnetic field, the dominant n ∥ of the LH wave in the scrape-off layer has been deduced during the 2019 experimental campaign. In the low density plasma, the measured dominant n ∥ of the LH waves is about 2.1, corresponding to the main peak 2.04 of the launched n ∥ spectrum. n ∥ deduced by the least-squares linear fit method remains near this value in the low density plasma with a high spatial correlation magnitude of 0.9. With an eight-channel probe system, a wave-number spectrum has also been deduced, which has a peak near to the measured dominant n ∥ .

47 OTHER INSTRUMENTATION↗

Probing circular polarization and magnetic field structure in active galactic nuclei

The composition and magnetic field morphology of relativistic jets can be studied using circular polarization (CP) measurement. Recent three-dimensional relativistic magnetohydrodynamic (3D RMHD) simulations coupled with radiative transfer (RT) calculations make strong predictions about the level (and morphology) of the jet’s CP emission. These simulations show that the sign of CP and the electric vector position angle (EVPA) are both sensitive to the jet’s magnetic field morphology within the radio core. We probe this theory by exploring whether the jet’s radio core EVPA orientation is consistent with the observed sign of the core CP in deep full-track polarimetric observations. Based on a selection of sources from earlier MOJAVE observations, we aim to probe the nature of linear polarization (LP) and CP in the innermost regions of jets from a small sample of nine blazars. This sample includes sources that have exhibited: (i) positive CP; (ii) negative CP; or (iii) positive and negative CP simultaneously in the radio core region. By coupling deep polarimetric observations of a carefully selected sample of blazars with state-of-the-art RMHD and RT calculations, we hope to gain a deeper understanding of the physics of blazar jets.

79 ASTRONOMY AND ASTROPHYSICS↗

Measurements of DIII-D poloidal field by fiber-optic pulsed polarimetry

A new technique for measuring the spatial and temporal structure of the poloidal field is presented, whereby the magnetic field causes the polarization of light traveling through an optical fiber to rotate via the Faraday effect by an amount proportional to the strength of the field oriented along the fiber. In fiber optic pulsed polarimetry, changes in the polarization of the backscatter light from the fiber are detected, thereby permitting measurement of the field as a function of position along the fiber. In this proof-of-principle experiment, specially prepared single-mode fibers with weak fiber Bragg gratings were installed in the poloidal direction on the outside of the thermal blanket on DIII-D. Light at 532 nm from a mode-locked Nd:YAG laser was injected into the optical fibers. The laser repetition rate was 895 kHz with a pulse length of <10 ps, resulting in ~1 μs temporal resolution. A photodetector system measured the Stokes polarization components necessary to determine the amount of polarization rotation. For this experiment, bandwidth limitations of the detectors resulted in a spatial resolution of ≈2 cm. The measured temporal and spatial distributions of the poloidal field are consistent with inductive probe measurements and Elastodynamic Finite Integration Technique reconstructions of the spatial distribution. Furthermore, this demonstrates the ability of this technique to provide real-time detection of the temporal and spatial variations of the poloidal field. Besides revealing more detailed information about the plasma, this new diagnostic capability can also help in detecting instabilities in real time, thereby enabling enhanced machine protection.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Relativistic electron response to the combined magnetospheric impact of a coronal mass ejection overlapping with a high-speed stream: Van Allen Probes observations

During early November 2013, the magnetosphere experienced concurrent driving by a coronal mass ejection (CME) during an ongoing high-speed stream (HSS) event. The relativistic electron response to these two kinds of drivers, i.e., HSS and CME, is typically different, with the former often leading to a slower buildup of electrons at larger radial distances, while the latter energizing electrons rapidly with flux enhancements occurring closer to the Earth. In this paper, we present a detailed analysis of the relativistic electron response including radial profiles of phase space density as observed by both Magnetic Electron and Ion Sensor (MagEIS) and Relativistic Electron Proton Telescope instruments on the Van Allen Probes mission. Data from the MagEIS instrument establish the behavior of lower energy (<1 MeV) electrons which span both intermediary and seed populations during electron energization. Measurements characterizing the plasma waves and magnetospheric electric and magnetic fields during this period are obtained by the Electric and Magnetic Field Instrument Suite and Integrated Science instrument on board Van Allen Probes, Search Coil Magnetometer and Flux Gate Magnetometer instruments on board Time History of Events and Macroscale Interactions during Substorms, and the low-altitude Polar-orbiting Operational Environmental Satellites. These observations suggest that during this time period, both radial transport and local in situ processes are involved in the energization of electrons. Finally, the energization attributable to radial diffusion is most clearly evident for the lower energy (<1 MeV) electrons, while the effects of in situ energization by interaction of chorus waves are prominent in the higher-energy electrons.

79 ASTRONOMY AND ASTROPHYSICS↗