Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Long stroke”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

150 records · Page 9

Cardiovascular response to lower body negative pressure stimulation before, during, and after space flight

BACKGROUND: It is well known that space travel cause post-flight orthostatic hypotension and it was assumed that autonomic cardiovascular control deteriorates in space. Lower body negative pressure (LBNP) was used to assess autonomic function of the cardiovascular system. METHODS: LBNP tests were performed on six crew-members before and on the first days post-flight in a series of three space missions. Additionally, two of the subjects performed LBNP tests in-flight. LBNP mimics fluid distribution of upright posture in a gravity independent way. It causes an artificial sequestration of blood, reduces preload, and filtrates plasma into the lower part of the body. Fluid distribution was assessed by bioelectrical impedance and anthropometric measurements. RESULTS: Heart rate, blood pressure, and total peripheral resistance increased significantly during LBNP experiments in-flight. The decrease in stroke volume, the increased pooling of blood, and the increased filtration of plasma into the lower limbs during LBNP indicated that a plasma volume reduction and a deficit of the interstitial volume of lower limbs rather than a change in cardiovascular control was responsible for the in-flight response. Post-flight LBNP showed no signs of cardiovascular deterioration. The still more pronounced haemodynamic changes during LBNP reflected the expected behaviour of cardiovascular control faced with less intravascular volume. In-flight, the status of an intra-and extravascular fluid deficit increases sympathetic activity, the release of vasoactive substances and consequently blood pressure. Post-flight, blood pressure decreases significantly below pre-flight values after restoration of volume deficits. CONCLUSION: We conclude that the cardiovascular changes in-flight are a consequence of a fluid deficit rather than a consequence of changes in autonomic signal processing.

manned↗

Association Between Cardiovascular and Intraocular Pressure Changes in a 14-Day 6 deg Head Down Tilt (HDT) Bed Rest Study: Possible Implications in Retinal Anatomy

Visual symptoms and intracranial pressure increase reported in astronauts returning from long duration missions in low Earth-orbit are thought to be related to fluid shifts within the body due to microgravity exposure. Because of this possible relation to fluid shifts, studies conducted in head-down tilt (HDT) bed rest are being monitored for potential changes in ocular health. These measures will also serve to determine whether HDT is a suitable ground-based analog to model subclinical cardiovascular and ocular changes that could shed light on the etiology of the VIIP syndrome observed in spaceflight. Sixteen healthy normotensive (12M, 4F, age range 29-54 years), non-smoker and normal weight subjects, volunteered to participate in a 14 day 6 deg head HDT study conducted at the NASA Flight Analogs Research Unit (FARU). This facility provides standard bed rest conditions (diet, wake/sleep time, time allowed in sunlight) during the time that the subjects stay at the FARU. Cardiovascular parameters were obtained in supine posture at BR-5, BR+0, and BR+3 and ocular monitoring was performed weekly. Intraocular pressure (IOP) increased from pre-bed rest BR-3) to the third day into bed rest (BR+3). Values reached a plateau towards the end of the bed rest phase (BR10) and decreased within the first three days of recovery (BR+2) returning to levels comparable to baseline at BR-3. As expected, most cardiovascular parameters were affected by 14 days of HDT bed rest. Plasma volume decreased as a result of bed rest but recovered to baseline levels by BR+3. Indications of cardiovascular deconditioning included increase in both systolic and diastolic blood pressure and heart rate, and a decrease in stroke volume and cardiac output between BR-5 and BR+3. Due to the experimental design of this study, we were not able to test the hypothesis that fluid shifts might be involved in the IOP increase during the bed rest phase, since cardiovascular measures were not available for those time points. There was no correlation between the largest change in IOP (BR-3 versus BR3) and cardiovascular measure changes between baseline (BR-5) and post bed rest (BR+2). While no clinically relevant visual changes were observed during the study, measurement of various retinal parameters was performed with optical coherence tomography (OCT). A decrease in central subfield retinal thickness was observed between BR+2 and baseline at BR-10, but no association was observed with IOP changes. This work investigates the time course of changes in IOP during 14-day HDT bed rest in an attempt to characterize HDT bed rest as a model of the VIIP syndrome and delve into its etiology.

Cromwell, Ronita↗

Diaphragm Pump With Resonant Piezoelectric Drive

A diaphragm pump driven by a piezoelectric actuator is undergoing development. This pump is intended to be a prototype of lightweight, highly reliable pumps for circulating cooling liquids in protective garments and high-power electronic circuits, and perhaps for some medical applications. The pump would be highly reliable because it would contain no sliding seals or bearings that could wear, the only parts subject to wear would be two check valves, and the diaphragm and other flexing parts could be designed, by use of proven methods, for extremely long life. Because the pump would be capable of a large volumetric flow rate and would have only a small dead volume, its operation would not be disrupted by ingestion of gas, and it could be started reliably under all conditions. The prior art includes a number piezoelectrically actuated diaphragm pumps. Because of the smallness of the motions of piezoelectric actuators (typical maximum strains only about 0.001), the volumetric flow rates of those pumps are much too small for typical cooling applications. In the pump now undergoing development, mechanical resonance would be utilized to amplify the motion generated by the piezoelectric actuator and thereby multiply the volumetric flow rate. The prime mover in this pump would be a stack of piezoelectric ceramic actuators, one end of which would be connected to a spring that would be part of a spring-and-mass resonator structure. The mass part of the resonator structure would include the pump diaphragm (see Figure 1). Contraction of the spring would draw the diaphragm to the left, causing the volume of the fluid chamber to increase and thereby causing fluid to flow into the chamber. Subsequent expansion of the spring would push the diaphragm to the right, causing the volume of the fluid chamber to decrease, and thereby expelling fluid from the chamber. The fluid would enter and leave the chamber through check valves. The piezoelectric stack would be driven electrically to make it oscillate at the resonance frequency of the spring and- mass structure. This frequency could be made high enough (of the order of 400 Hz) that the masses of all components could be made conveniently small. The resonance would amplify the relatively small motion of the piezoelectric stack (a stroke of the order of 10 m) to a diaphragm stroke of the order of 0.5 mm. The exact amplification factor would depend on the rate of damping of oscillations; this, in turn, would depend on details of design and operation, including (but not limited to) the desired pressure rise and volumetric flow rate. In order to obtain resonance with large displacement, the damping rate must be low enough that the energy imparted to the pumped fluid on each stroke is much less than the kinetic and potential energy exchanged between the mass and spring during each cycle of oscillation. To minimize the power demand of the pump, a highly efficient drive circuit would be used to excite the piezoelectric stack. This circuit (see Figure 2) would amount to a special-purpose regenerative, switching power supply that would operate in a power-source mode during the part of an oscillation cycle when the excitation waveform was positive and in a power-recovery mode during the part of the cycle when the excitation waveform was negative. The circuit would include a voltage-boosting dc-to-dc converter that would convert between a supply potential of 24 Vdc and the high voltage needed to drive the piezoelectric stack. Because of the power-recovery feature, the circuit would consume little power. It should be possible to build the circuit as a compact unit, using readily available components.

Izenson, Michael G.↗

Microtubule depolymerization normalizes in vivo myocardial contractile function in dogs with pressure-overload left ventricular hypertrophy

BACKGROUND: Because initially compensatory myocardial hypertrophy in response to pressure overloading may eventually decompensate to myocardial failure, mechanisms responsible for this transition have long been sought. One such mechanism established in vitro is densification of the cellular microtubule network, which imposes a viscous load that inhibits cardiocyte contraction. METHODS AND RESULTS: In the present study, we extended this in vitro finding to the in vivo level and tested the hypothesis that this cytoskeletal abnormality is important in the in vivo contractile dysfunction that occurs in experimental aortic stenosis in the adult dog. In 8 dogs in which gradual stenosis of the ascending aorta had caused severe left ventricular (LV) pressure overloading (gradient, 152+/-16 mm Hg) with contractile dysfunction, LV function was measured at baseline and 1 hour after the intravenous administration of colchicine. Cardiocytes obtained by biopsy before and after in vivo colchicine administration were examined in tandem. Microtubule depolymerization restored LV contractile function both in vivo and in vitro. CONCLUSIONS: These and additional corroborative data show that increased cardiocyte microtubule network density is an important mechanism for the ventricular contractile dysfunction that develops in large mammals with adult-onset pressure-overload-induced cardiac hypertrophy.

Non-NASA Center↗

Miniature Exercise Device-2 (MED-2): Preliminary ISS Evaluation Results for a Compact Motorized Resistive and Aerobic Rowing Exercise Device

Future human missions beyond Low Earth Orbit (LEO) will require onboard equipment to provide exercise capabilities for the crew to counter the adverse physiological effects of long-duration microgravity. To accomplish this within the physical constraints of a space vehicle or transit module, a single miniature device that provides both resistive and aerobic exercise modalities is required. To meet this need, Johnson Space Center’s (JSC) Software, Robotics, and Simulation Division (ER) developed the Miniature Exercise Device-2 (MED-2). MED-2 integrates a torque-controlled servomotor and a series-elastic actuator to provide highly-controllable load profiles and a large magnitude output performance in a very small package. This innovative technology is derived from years of JSC/ER design, development and operational experience with cutting-edge robotics, motor controllers, software and actuator/sensor miniaturization, including Robonaut 2 and MED-1. MED-2 was presented at the 2016 ISS R&D Conference. This is an update now that the last of six crewmembers will have completed planned MED-2 sessions on the International Space Station (ISS) in May 2018.Current state-of-the-art ISS exercise equipment consists of two treadmills, a resistive exercise device and two cycle ergometers with a total mass of several thousand pounds and a total volume of several cubic yards. This equipment has proven vital to mitigate the musculoskeletal and cardiovascular degradation effects of microgravity. However, due to the large operational volume and mass of these ISS devices, tailoring them for smaller vehicles, such as Orion, is not possible. In addition, each of the current ISS devices targets a single specific modality. Compared to the existing spaceflight (and even terrestrial) exercise equipment, MED-2 is a new archetype altogether. The combined features of compact size, multi-modality and high-performance is attributable to its innovative series elastic actuator and motor controller. Following its arrival on ISS in 2016, MED-2 was evaluated in two parts. The first and shorter evaluation was an engineering functional checkout of the hardware. As this was a novel exercise device previously never used on ISS, the initial checkout assessed the operation of the hardware and ensured the motion and dynamic range of the crew did not present any collision or other hazards. The second portion of the study collected the heart rates, kinematics and utilized operational volumes of six astronauts to determine the quality of both the resistive and aerobic exercise modalities as delivered by MED-2. Investigators from JSC Biomedical Research and Environmental Science Division (SK) and Glenn Research Center are currently evaluating the data and preparing preliminary results. For the resistive exercise modality, MED-2 demonstrated a range of constant resistive loads from 10-150 lbf. With a displacement range of 84 inches, the MED-2 accommodates users from 5th percentile Japanese female through 95th percentile American male for all of its certified exercises. The displacement measurement accuracy has also been verified within 2.5 percent full range. The crew was able to successfully perform all prescribed resistive exercises, except Goblet Squats which were not feasible with a constant load profile. For the aerobic exercise modality, MED-2 simulated a rowing motion with prescribed and user-selected resistance levels. It has demonstrated rates up to 60 strokes per minute on the ground. MED-2 loads and displacements performance are the same as those cited for the resistive modality. Although each of the crew was able to perform the prescribed aerobic rowing sets, there was considerable variability in the rowing motion among different crewmembers. Also, as expected, the crew was unable to get the full benefits of a typical terrestrial rowing stroke because the current configuration does not allow the user to reach past their feet. These observations have already informed the requirements for other microgravity rowing devices currently in development. One of the unique features of the MED-2 device is the intuitive touch-screen control system. This One Portal graphical user interface (GUI) was developed based on JSC/ER’s heritage knowledge and experience of developing and sustaining the current ISS exercise equipment. Through this interface, the crew easily performed prepared prescriptions as well as had the ability to adjust exercise modality, load and other exercise details such as number of repetitions and number of sets. This touch-screen and GUI fulfilled the MED-2 project goal to simplify the interaction between the user and the device. Furthermore, the extent to which MED-2 utilizes a touchscreen and GUI to control exercise equipment is unmatched among the existing ISS exercise devices. As a motorized device, MED-2 technology can provide a customizable force profile that can be varied as a function of strap displacement, strap velocity or a combination of these and other variables. During 2017, JSC/ER developed and flight-certified a resistive exercise algorithm that mimics the 1-G inertial effects of free-weights and enables adjustable eccentric-to-concentric loading ratios. Subsequent development will explore varying the load profiles and incorporating additional exercises beyond the current list of certified movements.

Exercise↗

Nicotinamide-Loaded Peptoid Nanotubes for Energy Regeneration in Acute Brain Injury

Acute brain injuries such as perinatal asphyxia, stroke, and traumatic brain injury result in ischemia, oxidative stress, excitotoxicity, and inflammation, leading to a depletion of ATP. Nicotinamide adenine dinucleotide (NAD+) is crucial for ATP regeneration and DNA repair during postinjury recovery. However, the therapeutic benefits of NAD+ and its precursors, such as nicotinamide (NAM), are limited by challenges in achieving effective cell-specific intracellular delivery. In this study, we use a nanopeptoid delivery strategy to replenish the cellular redox state and increase energy production in the acutely injured brain. By self-assembling peptoids into tubular structures, we created biocompatible NAM-conjugated peptoid nanotubes (NAM-PNTs) that vary in tubular length. NAM-PNTs demonstrated significant therapeutic benefits by enhancing cell viability and replenishing intracellular ATP levels within 24 h of treatment in oxygen–glucose-deprived (OGD) BV-2 cells. In organotypic brain slices, NAM-PNT treatment promoted glial proliferation, reduced proinflammatory cytokines, and increased anti-inflammatory cytokines after OGD, an ex vivo model of hypoxia-ischemia. The effect of NAM-PNTs is associated with their uptake into microglia via fluid-phase phagocytosis and caveolae-mediated endocytosis. A single systemic dose of NAM-PNTs localized in microglia in the injured hemisphere and reduced brain tissue loss and improved neuropathology after hypoxia-ischemia in term-equivalent rats. These findings highlight the therapeutic potential of NAM-PNTs for cell-specific targeted delivery and energy restoration in the acutely injured neonatal brain. In the neonatal brain injury field, this work demonstrates the development of an innovative nanoparticle platform from first-principles design and synthesis to in vitro screening and then demonstration of efficacy in vivo .

ATP↗