Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Location”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Effects of cluster expansion on the locations of phase transition boundary as a first step to quantify uncertainty in first principles statistical mechanics framework

Predicting phase diagrams from first principle calculations eliminates the need of tedious experimental trials and errors. Fully automating first principle phase diagram calculations without any sort of human intervention has been a long daunting task and troubling scientific communities for decades. This grand problem remains not fully resolved, largely due to the vastly high-dimensional parameter space associated with density functional theory, cluster expansion, lattice Monte Carlo, and the substantial uncertainty propagating through a set of complex simulations. As a first step to tackle this grand problem, we reported a first demonstration of how sensitive phase boundary locations can be to various cluster expansion fittings and input DFT training data. To the best knowledge of the authors, this study reported the first ever attempt to quantify uncertainty in first principles statistical mechanics framework. In addition, a semi-automated phase transition detection algorithm has been devised in this paper to deal with the associated statistical errors and uncertainties from Monte Carlo method and its predecessor DFT calculations and cluster expansions. This algorithm has been applied in a classical cluster expansion Mg-Cd binary alloy system to detect phase transitions at various locations of phase diagram using different cluster expansions to demonstrate its predictive power and quantify uncertainties. The results suggested that using Chebyshev basis function shifted the transition locations toward the dilute solid solution phase and expanded the phase stability of concentrated ordered phases to wider composition range. The addition of perturbed defect configurations into training data set lowered the order-disorder transition temperature to be away from true transition temperature, suggesting the transition nature is indeed configurational disorder dominated rather than defect assisted. Finally, we found that the weighting has negligible effect on the transition locations, except for the case of using Chebyshev basis function to fit all non-weighted configurations that can be susceptible to Monte Carlo sampling hysteresis.

36 MATERIALS SCIENCE↗

An algorithm to locate the centers of baryon acoustic oscillations

The cosmic structure formed from baryon acoustic oscillations (BAO) in the early universe is imprinted in the galaxy distribution observable in large-scale surveys and is used as a standard ruler in contemporary cosmology. Typically, BAOs are detected as a preferential length scale in two-point statistics, which gives little information about the location of the BAO structures in real space. The aim of the algorithm described in this paper is to find probable centers of BAOs in the cosmic matter distribution. The algorithm convolves the three-dimensional distribution of matter density with a spherical shell kernel of variable radius placed at different locations. The locations that correspond to the highest values of the convolution correspond to the probable centers of BAOs. This method is realized in an open-source, computationally efficient algorithm. Here, we describe the algorithm and present the results of applying it to the SDSS DR9 CMASS survey and associated mock catalogs. A detailed performance study demonstrates the ability of the algorithm to locate BAO centers and in doing so presents a novel detection of the BAO scale in galaxy surveys.

79 ASTRONOMY AND ASTROPHYSICS↗

Setting the H-mode pedestal structure: variations of particle source location using gas puff and pellet fueling

Experiments in DIII-D show that a particle source location inside the top of the H-mode pedestal (pellets) maintains a higher pedestal pressure than an edge source (gas fueling) through a widening of the electron temperature pedestal with reduction of the temperature gradient. The effect of these two fueling schemes on the H-mode pedestal structure was examined in DIII-D by comparing controlled pellet-fueled and gas-fueled discharges across a fueling scan up to 40 torr 1 s –1 . High resolution electron profiles reveal that gas fueling lowers the pedestal pressure as the density profile shifts radially outwards and the separatrix density increases, while pellet fueling maintains a constant pedestal pressure. The neutral source locations from pellets and gas are determined with the PELLET and UEDGE codes, respectively, and quantify the particle source localization. Pellets provide significant ionization inside the pedestal top while gas puffing localizes ionization in the scrape-off-layer and pedestal foot, broadly consistent with the density profile structure influenced by the source. ELMs are observed to increase in frequency and reduce impurity content as fueling is increased. Stability analysis with ELITE shows that both conditions are near the type-I ELM corner of the peeling–ballooning stability diagram, which is altered significantly by the introduction of pellets. Since transport mechanisms are not observed to change substantially with particle source location, wider pedestals allow the pellet-fueled discharges to retain higher pedestal temperatures at similar pedestal densities. EPED1 is tested to capture the pedestal pressure, under-predicting the height with pellets and over-predicting the height with gas by ~15%. Overall, these results have important implications for future reactors where pellet fueling will be the primary particle source due to an opaque scrape-off-layer by showing that the neutral source location plays a role in setting the structure of the H-mode pedestal.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Techno-economic assessment of electricity market potential for co-located hydro-floating PV systems

Abstract—Harnessing renewable energy from diverse sources is paramount for sustainable power systems. Recently, co-located floating PV (FPV) systems present an intriguing prospect in this context. These hybrid systems, blending hydro and solar power, may offer a more consistent electricity output and potential economic advantages. Yet, assessing their actual potential requires a comprehensive techno-economic assessment. In addition, probabilistic price forecasting has recently gained attention in electricity market because decisions based on such predictions can yield significantly higher profits than those made with point forecasts alone. To this end, this paper embarks on a journey to elucidate the electricity market potential of co-located hydro-FPV systems in a probabilistic fashion to investigate the technological merits and economic viability of co-located hydro-FPV under different market structures. Our preliminary findings suggest that LCOE and payback metrics are sensitive not only to different markets but also to different solar incentives. Concurrently, we also observe that the payback period is generally faster with a production tax credit (PTC) than an investment tax credit (ITC). This assessment serves as a cornerstone for understanding the future prospects of co-located hydro-FPV systems in modern electricity markets.

13 HYDRO ENERGY↗

Evaluating Synthetic Smart Meter Locations For Communication System Modeling

An important part of good communication models for smart grid applications, particularly when wireless protocols are used, is the location information of the nodes. We’ve developed metrics to assist in evaluating whether a given model with such information is representative of feeders found in the world. These metrics are applied to a set of feeder models with known good location information for the smart meter locations and compared to a set of feeder models with similar location information that is not expected to be representative of real-world feeders. The comparison reveals that the suspect models do not pass statistical tests utilizing the developed metrics, providing initial validation of the analysis technique.

smart meter, feeder model, GridLAB-D↗

Location Generalizer

This software produces general location descriptions from time-series location data collected from mobile devices that record global positioning system (GPS) coordinates over time. The purpose of this software is to convert detailed location history data, which is considered personally identifiable information (PII), into non-traceable, anonymized, generic information that is useful to researchers but does not contain PII. The software is specifically designed for use with trigger-based data that describe the parked locations and dwell times of automobiles.

Smart, John↗

Transcatheter Arterial Chemoembolization for Treatment-Naive Hepatocellular Carcinoma Has Different Treatment Effects Depending on Central or Peripheral Tumor Location

Introduction: The purpose of this study was to evaluate the treatment efficacy of transcatheter arterial chemoembolization (TACE) for treatment-naive hepatocellular carcinoma (HCC) according to tumor location and burden. Methods: Between 2010 and 2019, consecutive patients who underwent TACE as the first treatment were enrolled. Tumors were classified into two categories based on their location, as central or peripheral tumors. Tumors in the central zone, which is within 1 cm of the main trunk or the first branch of the portal vein, were classified as central tumors, while those located in the peripheral zone were classified as peripheral tumors. Patients were grouped according to the HCC location and up-to-7 criteria. Patients with central tumors were classified into the central arm and those with only peripheral tumors were classified into the peripheral arm. Patients within and beyond the up-to-7 criteria were classified into the up-to-7 in and up-to-7 out-groups, respectively. Local recurrence-free survival (LRFS) and progression-free survival (PFS) were compared per nodule (central tumor vs. peripheral tumor) and per patient (central arm vs. peripheral arm), respectively. The prognostic factors of LRFS and PFS were analyzed by univariate and multivariate analyses. Results: A total of 174 treatment-naive patients with 352 HCCs were retrospectively enrolled. Ninety-six patients and 130 lesions were selected by propensity score matching. Median LRFS was longer for peripheral tumors than central tumors (not reached vs. 3.3 months, p < 0.001). Median PFS was 17.1 months (8.3–24.9) in the peripheral arm and up-to-7 in, 7.0 months (3.3–12.7) in the peripheral arm and up-to-7 out, 8.4 months (4.0–12.6) in the central arm and up-to-7 in, and 3.0 months (1.2–4.9) in the central arm and up-to-7 out-groups. The peripheral arm and up-to-7 in-groups had significantly longer PFS than the other three groups (p = 0.013, p = 0.015, p < 0.001, respectively). Multivariate analysis confirmed that the central zone and central arm were associated with high adjusted hazard ratios for tumor recurrence or death (2.87, p < 0.001; 2.89, p < 0.001, respectively). Conclusion: Treatment-naive HCCs in the peripheral zone had a longer LRFS and PFS following TACE compared to those in the central zone.

Gastroenterology & Hepatology↗

Machine Learning Approach for Spatiotemporal Multivariate Optimization of Environmental Monitoring Sensor Locations

Abstract Long-term environmental monitoring is critical for managing the soil and groundwater at contaminated sites. Recent improvements in state-of-the-art sensor technology, communication networks, and artificial intelligence have created opportunities to modernize this monitoring activity for automated, fast, robust, and predictive monitoring. In such modernization, it is required that sensor locations be optimized to capture the spatiotemporal dynamics of all monitoring variables as well as to make it cost-effective. The legacy monitoring datasets of the target area are important to perform this optimization. In this study, we have developed a machine-learning approach to optimize sensor locations for soil and groundwater monitoring based on ensemble supervised learning and majority voting. For spatial optimization, Gaussian process regression (GPR) is used for spatial interpolation, while the majority voting is applied to accommodate the multivariate temporal dimension. Results show that the algorithms significantly outperform the random selection of the sensor locations for predictive spatiotemporal interpolation. While the method has been applied to a four-dimensional dataset (with two-dimensional space, time, and multiple contaminants), we anticipate that it can be generalizable to higher-dimensional datasets for environmental monitoring sensor location optimization.

Siddiquee, Masudur R.↗

Selection of Well Locations for Saturated Zone Monitoring at the E-Area Low Level Waste Facility

Savannah River Site (SRS) has adopted a revised approach to performance monitoring of the E- Area Low Level Waste Facility (ELLWF) that adds a saturated zone component to the existing vadose zone monitoring program (Kubilius, 2019). The revised monitoring approach specifies that eight additional water table wells be installed near Slit Trench 1 (ST1) and Engineered Trench 2 (ET2). Six wells will be installed at locations characterized in 2017 and 2018. These include four wells near ET2 (ELF001D, ELF002D, ELF003D, and ELF004D) at locations identified by Kubilius (2019) and two wells north of ST1 (ELF005D and ELF006D) at locations finalized in this report. Additionally, two wells (ELF007D and ELF008D) are to be installed at locations south of ST1 based on characterization work completed in 2020 and documented in this report. This area is near well cluster BGX-2 between the Mixed Waste Management Facility (MWMF) and the ELLWF. The area is upgradient of ELLWF and, contamination in the water table aquifer is sourced from MWMF.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Hanford Waste Treatment Plant LAB Facility Stack Effluent Monitoring: Sampling Probe Location Qualification Evaluation

The Waste Treatment Plant laboratory (LAB) facility stack monitor locations were qualified using scale model stacks to mitigate the risk of identifying that sampling locations do not meet the qualification criteria on the full-scale stack. As required by the American National Standards Institute/Health Physics Society (ANSI/HPS) N13.1-1999 standard, the scale model and its sampling location were geometrically similar to the actual stack and the Reynolds numbers for both the actual and model stacks were >10,000. An additional criterion is that the product of the hydraulic diameter and mean velocity (DV) of the full-scale stack must be between 1/6 DV and 6 DV of the scale model stack tests. Verification tests of the LAB stacks were performed at normal operating conditions. The minimum 1/6 DV value, along with the maximum 6 DV value from the scale model testing determines the range of conditions for which the full-scale stack may be operated and remain in compliance with the stack verification criterion. Based on these DV values, the corresponding stack flow rates for each of the LAB stacks are 625 to 47,237 scfm for LB-C2, 1,704 to 103,131 scfm for LB-S1, and 467 to 18,088 scfm for LB-S2. The remaining criteria for the stack verification to be considered valid involve the flow angle and velocity uniformity results. First, the flow angle at the full-scale stack must be =20°. Second, the velocity uniformity at the full-scale stack must be =20% coefficient of variance (COV). Finally, the velocity uniformity results for the actual and scale model stack tests must agree within 5% COV. These criteria were met through the full-scale stack tests at the LAB facility. Flow angle results were primarily less than 10 degrees, except for the LB-C2 Fan A results, which were an average of 17.6 degrees; all flow angle results were within the =20° criterion. The velocity uniformity results for each test condition averaged between 1.5 and 3.5% COV, which were all within the range of the target %COV values from the scale model tests. Based on these stack verification test results, the three LAB filtered exhaust stack sampling locations meet the qualification criteria provided in the ANSI/HPS N13.1-1999 standard for all fan operating configurations. This includes single-fan as well as dual-fan operations for LB-C2, each of the dual-fan operating conditions for LB-S1, and each single-fan operating condition for LB-S2. Further changes to the system configuration or operating conditions that are outside the bounds described in this report may require additional tests or analyses to determine compliance with the standard.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Sensor Impact Evaluation at Different Sensor Locations in a Multi-zone Office Building

FY 2022 Q1 deliverables include the development of an emulator that can evaluate the sensor impacts at different sensor locations (i.e., thermostat locations) in a multizone office building. This report presents the detailed procedure of developing the emulator and using the emulator for preliminary sensor impact analysis. In designing new multizone buildings or retrofitting existing buildings, the room thermostat locations or subzoning design has been often determined by best practices without considering the effects of this design in terms of energy or thermal comfort. In subzoning design, the total number of thermostats is usually smaller than the total number of rooms. As a result, one thermostat in one room often controls the indoor temperature of several other adjacent rooms. For example, five zones might share one thermostat located in one of the zones. Because the demands for thermal load in different zones could be different for the multizone buildings, this subzoning design can compromise control performance and waste building energy consumption. Furthermore, for multizone buildings, subzoning could introduce thermal discomfort for zones. This issue has not be thoroughly investigated in simulation/field studies, and the US Department of Energy’s Oak Ridge National Laboratory explored the impacts of subzoning design through modeling and experimental study.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Hanford Waste Treatment Plant LAB Facility Stack Effluent Monitoring: Sampling Probe Location Qualification Evaluation

The Waste Treatment Plant laboratory (LAB) facility stack monitor locations were qualified using scale model stacks to mitigate the risk of identifying that sampling locations do not meet the qualification criteria on the full-scale stack. As required by the American National Standards Institute/Health Physics Society (ANSI/HPS) N13.1-1999 standard, the scale model and its sampling location were geometrically similar to the actual stack, and the Reynolds numbers for both the actual and model stacks were >10,000. An additional criterion is that the product of the hydraulic diameter and mean velocity (DV) of the full-scale stack must be between 1/6 DV and 6 DV of the scale model stack tests. Verification tests of the LAB stacks were performed at normal operating conditions. The minimum 1/6 DV value, along with the maximum 6 DV value from the scale model testing, determines the range of conditions for which the full-scale stack may be operated and remain in compliance with the stack verification criterion. A practical range for the full-scale stack qualification uses the average DV through 6 DV from the scale model tests to compute the corresponding flow rates. Table S1 lists the operating flow rates along with the average and maximum qualified stack flow rates for each of the LAB facility stacks. For each stack, the operating flow is below the maximum qualified stack flow, which means that the scale model test results are acceptable for stack qualification. The remaining criteria for the stack verification to be considered valid involve the flow angle and velocity uniformity results. First, the flow angle at the full-scale stack must be ≤20°. Second, the velocity uniformity at the full-scale stack must be ≤20% coefficient of variance (COV). Finally, the velocity uniformity results for the actual and scale model stack tests must agree within 5% COV. These criteria were met through the full-scale stack tests at the LAB facility. Flow angle results were primarily less than 10°, except for the LB-C2 Fan A results, which were an average of 13.7°; all flow angle results were within the ≤20° criterion. The velocity uniformity results for each test condition averaged between 1.5 and 4.1% COV, which were all within the range of the target percent coefficient of variation values from the scale model tests. Based on these stack verification test results, the three LAB filtered exhaust stack sampling locations meet the qualification criteria provided in the ANSI/HPS N13.1-1999 standard for all fan operating configurations. This includes single-fan as well as dual-fan operations for LB-C2, each of the dual-fan operating conditions for LB-S1, and each single-fan operating condition for LB-S2. Further changes to the system configuration or operating conditions that are outside the bounds described in this report may require additional tests or analyses to determine compliance with the standard.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Rock Valley Direct Comparison Relocation Working Group Location Results and Recommendations

Work accomplished: Collected and compared historic data for the 1993 Rock Valley earthquake sequence; Compared preliminary and prior location work from different location algorithms, phase pick sets, station constellations, and velocity models; Selected a common set of stations that could be used across all location methods for consistency; Reviewed 8 different sets of phase picks and converged on a single, reviewed set of picks for all common stations; Evaluated four pre-existing regional velocity models and incorporated new and preliminary results for five new velocity models that provide information on the very shallow (< 2km) structure near station RTPP; Compared location results from different methods while using the common sets of picks, stations, and velocity models

58 GEOSCIENCES↗

Adaptive Determination of the Optimal Exchange Location in Wall-Modeled Large-Eddy Simulation

Wall-modeled large-eddy simulation introduces a modeling interface (or exchange location) separating the wall-modeled layer from the rest of the domain. The current state-of-the-art is to rely on user expertise when choosing where to place this modeling interface, whether this choice is tied to the grid or not. This paper presents a postprocessing algorithm that determines the exchange location systematically. The algorithm is based on a model for the error in the predicted wall shear stress and a model for the computational cost, and then finds the exchange location that minimizes a combination of the two. Here, the algorithm is tested both a priori and a posteriori using an equilibrium wall model for the flow over a wall-mounted hump, a boundary layer in an adverse pressure gradient, and a shock/boundary-layer interaction. The algorithm produces exchange locations that mostly agree with what an experienced user would suggest, with thinner wall-modeled layers in nonequilibrium flow regions and thicker wall-modeled layers where the boundary layer is closer to equilibrium. This suggests that the algorithm should be useful in simulations of realistic and highly complex geometries.

42 ENGINEERING↗

Tracking Robot Location for Non-Destructive Evaluation of Double-Shell Tanks

(1) Background: Non-destructive evaluation of double-shell nuclear-waste storage tanks at the U.S. Department of Energy’s Hanford site requires a robot to navigate a network of air slots in the confined space between primary and secondary tanks. Situational awareness, data collection, and data interpretation require continuous tracking of the robot’s location. (2) Methods: Robot location is continuously monitored using video image analysis for short distances and laser ranging for absolute location. (3) Results: The technique was demonstrated in our laboratory using a mockup of air slot and robot. (4) Conclusions: Location tracking and display provide decision support to inspectors and lay the groundwork for automated data collection.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Random Forest Regressor-Based Approach for Detecting Fault Location and Duration in Power Systems

Power system failures or outages due to short-circuits or “faults” can result in long service interruptions leading to significant socio-economic consequences. It is critical for electrical utilities to quickly ascertain fault characteristics, including location, type, and duration, to reduce the service time of an outage. Existing fault detection mechanisms (relays and digital fault recorders) are slow to communicate the fault characteristics upstream to the substations and control centers for action to be taken quickly. Fortunately, due to availability of high-resolution phasor measurement units (PMUs), more event-driven solutions can be captured in real time. In this paper, we propose a data-driven approach for determining fault characteristics using samples of fault trajectories. A random forest regressor (RFR)-based model is used to detect real-time fault location and its duration simultaneously. This model is based on combining multiple uncorrelated trees with state-of-the-art boosting and aggregating techniques in order to obtain robust generalizations and greater accuracy without overfitting or underfitting. Four cases were studied to evaluate the performance of RFR: 1. Detecting fault location (case 1), 2. Predicting fault duration (case 2), 3. Handling missing data (case 3), and 4. Identifying fault location and length in a real-time streaming environment (case 4). A comparative analysis was conducted between the RFR algorithm and state-of-the-art models, including deep neural network, Hoeffding tree, neural network, support vector machine, decision tree, naive Bayesian, and K-nearest neighborhood. Experiments revealed that RFR consistently outperformed the other models in detection accuracy, prediction error, and processing time.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Snowflake: An Adaptive Energy and Delay Efficient Scheme for Source Location Privacy in Wireless Sensor Networks

Wireless Sensor Networks (WSNs) consist of a number of resource-constrained sensor nodes and a designated node called a sink, which collects data from the sensor nodes. A WSN can be used in numerous applications such as subject tracking and monitoring, where it is often desirable to keep the location of the subject private. In these types of applications, an adversary can locate the monitored subject, if a location privacy protection scheme is not applied. In this paper, we propose an adaptive energy and delay efficient scheme, called Snowflake, that conceals the location of subjects from a global adversary. Snowflake can be adapted to make the delivery delay smaller, or to make the packet overhead low. The simulation results show that Snowflake performs better than an existing algorithm.

97 MATHEMATICS AND COMPUTING↗

Co-located temperature and electrical resistivity measurements for permafrost mapping, Teller 27, Teller 47 and Kougarok 64, Seward Peninsula, Alaska, late summers of 2018, 2019, 2021, and 2022

This data set contains co-located shallow soil (0.8m below ground level) and electrical resistivity at various depth extracted from Electrical Resistivity Tomography (ERT) measurements. Data were acquired at three watersheds on the southern Seward Peninsula during the late summers of 2018, 2019, 2021, and 2022. The three watersheds are located along the Nome-Teller Highway at mile markers 27 and 47, and along Kougarok Road mile marker 64. The co-located temperature and electrical resistivity data were used to (1) map the spatial extend of near surface permafrost, and (2) for supervised classification of permafrost bodies. This dataset contains .csv, .txt, .srv files and flmd reporting format with data dictionary. Find information about the .srv files at "https://e4d-userguide.pnnl.gov/e4d_guide/elec/e4d_e4d-survey.html". The Next-Generation Ecosystem Experiments: Arctic (NGEE Arctic), was a research effort to reduce uncertainty in Earth System Models by developing a predictive understanding of carbon-rich Arctic ecosystems and feedbacks to climate. NGEE Arctic was supported by the Department of Energy's Office of Biological and Environmental Research. The NGEE Arctic project had two field research sites: 1) located within the Arctic polygonal tundra coastal region on the Barrow Environmental Observatory (BEO) and the North Slope near Utqiagvik (Barrow), Alaska and 2) multiple areas on the discontinuous permafrost region of the Seward Peninsula north of Nome, Alaska. Through observations, experiments, and synthesis with existing datasets, NGEE Arctic provided an enhanced knowledge base for multi-scale modeling and contributed to improved process representation at global pan-Arctic scales within the Department of Energy's Earth system Model (the Energy Exascale Earth System Model, or E3SM), and specifically within the E3SM Land Model component (ELM).

54 ENVIRONMENTAL SCIENCES↗