Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “LITHIUM FLUORIDES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

From nGy to MGy - New dosimetry with LiF:Mg,Cu,P thermoluminescence detectors

One of the well known advantages of thermoluminescence (TL) detectors made of lithium fluoride doped with magnesium, copper and phosphorus (LiF:Mg,Cu,P) is their very high sensitivity to ionizing radiation. LiF:Mg,Cu,P detectors enable measurements of radiation doses from tens of nanograys up to a few kilograys, when the total saturation of the signal of the so-called main dosimetric peak occurs. Only recently, unprecedented high-temperature emission of LiF detectors heated to temperatures up to 600 Degree-Sign C, was observed after exposures to radiation doses ranging from 1 kGy to 1 MGy. For quantification of the glow-curve shape changes of LiF:Mg,Cu,P detectors in this range of doses and determination of the absorbed dose, the Ultra-High Temperature Ratio coefficient (UHTR) was defined. This newly established dosimetric method was tested in a range of radiation qualities, such as gamma radiation, electron and proton beams, thermal neutron fields and high-energy mixed fields around the SPS and PS accelerators at CERN. The new method for ultra-high dose range monitoring with a single LiF:Mg,Cu,P detector, which is capable of covering at least twelve orders of magnitude of doses, can be used for dosimetry at high energy accelerators, thermonuclear fusion technology facilities and has great potential for accident dosimetry in particular. A number of dosimetric sets with LiF:Mg,Cu,P detectors are currently installed around the LHC at CERN.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-T-612: Photonuclear Activation of Prosthetic Hips in Radiotherapy

Purpose: To measure the neutron induced activation of a prosthetic hip when exposed to an 18 MV radiotherapy linac beam to assess the potential dose to patients. Methods: A prosthetic hip (Thackray, UK) was placed in a water phantom and irradiated (both in-field and out-of-field) with an 18 MV linac beam. Gamma spectroscopy was used to identify the radioisotopes produced. Following the in-field irradiation where the induced activity is higher, high sensitivity lithium fluoride Thermoluminescence Dosimeters (TLD-100H) (Harshaw, USA) were placed on the surface to measure the dose which would be deposited to nearby tissue resulting from the induced radioactivity. Results: The radioisotopes produced in the hip prosthesis have been identified as {sup 5{sup 2}}V, {sup 5{sup 3}}Fe, and {sup 56}Mn which have half-lives of 3.74, 8.51 and minutes respectively. The 378 and 511 keV characteristic peaks of {sup 5{sup 3}}Fe do not appear in the spectra collected from hips irradiated in the out-of-field region. This isotope is produced by photonuclear interactions within the hip itself. {sup 52}V and {sup 56}Mn appear in spectra collected from hips irradiated either within the photon beam or in the nearby out-of-field region, implying that they are produced by incident neutron radiation produced in components of the linear accelerator.The integrated dose which would be deposited in the tissue immediately surrounding the hip after four hours (1.5 half-lives of the longest lived product) was measured as approximately 100 µGy, following a 10,000 MU irradiation of the prosthesis. A highly accurate measurement of the dose is challenging because of the irregular shape of the prosthesis. Conclusion: The cumulative dose measured at the surface of the hip is 0.0001% of the in-field dose, and is therefore negligible compared with the doses the patient receives as a consequence of their treatment.

61 RADIATION PROTECTION AND DOSIMETRY↗

In-patient to isocenter KERMA ratios in CT

Purpose: To estimate in-patient KERMA for specific organs in computed tomography (CT) scanning using ratios to isocenter free-in-air KERMA obtained using a Rando phantom.Method: A CT scan of an anthropomorphic phantom results in an air KERMA K at a selected phantom location and air kerma K{sub CT} at the CT scanner isocenter when the scan is repeated in the absence of the phantom. The authors define the KERMA ratio (R{sub K}) as K/ K{sub CT}, which were experimentally determined in a Male Rando Phantom using lithium fluoride chips (TLD-100). R{sub K} values were obtained for a total of 400 individual point locations, as well as for 25 individual organs of interest in CT dosimetry. CT examinations of Rando were performed on a GE LightSpeed Ultra scanner operated at 80 kV, 120 kV, and 140 kV, as well as a Siemens Sensation 16 operated at 120 kV. Results: At 120 kV, median R{sub K} values for the GE and Siemens scanners were 0.60 and 0.64, respectively. The 10th percentile R{sub K} values ranged from 0.34 at 80 kV to 0.54 at 140 kV, and the 90th percentile R{sub K} values ranged from 0.64 at 80 kV to 0.78 at 140 kV. The average R{sub K} for the 25 Rando organs at 120 kV was 0.61 {+-} 0.08. Average R{sub K} values in the head, chest, and abdomen showed little variation. Relative to R{sub K} values in the head, chest, and abdomen obtained at 120 kV, R{sub K} values were about 12% lower in the pelvis and about 58% higher in the cervical spine region. Average R{sub K} values were about 6% higher on the Siemens Sensation 16 scanner than the GE LightSpeed Ultra. Reducing the x-ray tube voltage from 120 kV to 80 kV resulted in an average reduction in R{sub K} value of 34%, whereas increasing the x-ray tube voltage to 140 kV increased the average R{sub K} value by 9%. Conclusions: In-patient to isocenter relative KERMA values in Rando phantom can be used to estimate organ doses in similar sized adults undergoing CT examinations from easily measured air KERMA values at the isocenter (free in air). Conversion from in-patient air KERMA values to tissue dose would require the use of energy-appropriate conversion factors.

61 RADIATION PROTECTION AND DOSIMETRY↗

Magnetism reflectometer study shows LiF layers improve efficiency in spin valve devices

New, more efficient materials for spin valves - a device used in magnetic sensors, random access memories, and hard disk drives - may be on the way based on research using the magnetism reflectometer at Oak Ridge National Laboratory (ORNL). Spin valve devices work by means of two or more conducting magnetic material layers that alternate their electrical resistance depending on the layers alignment. Giant magnetoresistance is a quantum mechanical effect first observed in thin film structures about 20 years ago. The effect is observed as a significant change in electrical resistance, depending on whether the magnetization of adjacent ferromagnetic layers is in a parallel or an antiparallel magnetic alignment. 'What we are doing here is developing new materials. The search for new materials suitable for injecting and transferring carriers with a preferential spin orientation is most important for the development of spintronics,' said Valeria Lauter, lead instrument scientist on the magnetism reflectometer at the Spallation Neutron Source (SNS), who collaborated on the experiment. The researchers discovered that the conductivity of such materials is improved when an organic polymer semiconductor layer is placed between the magnetic materials. Organic semiconductors are now the material of choice for future spin valve devices because they preserve spin coherence over longer times and distances than conventional semiconductors. While research into spin valves has been ongoing, research into organic semiconductors is recent. Previous research has shown that a 'conductivity mismatch' exists in spin valve systems in which ferromagnetic metal electrodes interface with such organic semiconductors as Alq3 ({pi}-conjugated molecule tris(8-hydroxy-quinoline) aluminium). This mismatch limits the efficient injection of the electrons from the electrodes at the interface with the semiconductor material. However, lithium fluoride (LiF), commonly used in light-emitting diodes, has been found to enhance the injection of electrons through the semiconductor. Researchers from the University of Alabama and ORNL used polarized neutrons at the magnetism reflectometer at SNS to investigate the electronic, magnetic, and structural properties of the electrodes in a novel system. In this system, the magnetic layers cobalt and Ni{sub 80}Fe{sub 20} are interfaced with spacer layers composed of the organic semiconductor Alq3. A coupling layer of LiF is inserted to separate the magnetized layers from the semiconductor. 'ALQ3 is an organic semiconductor material,' said Lauter. 'Normally in these systems a first magnetic layer is grown on a hard substrate so that one can get the controlled magnetic parameters. Then you grow the organic semiconductor layer, followed by another magnetic material layer, such as cobalt.' In addition to determining the effect of the LiF layers on the efficiency of the electron injection, the researchers wanted to determine the magnetic properties of the cobalt and Ni{sub 80}Fe{sub 20} as well as the interfacial properties: whether there is interdiffusion of cobalt through the LiF layer to the semiconductor, for example. The researchers used polarized neutrons at beam line 4A to probe the entire, layer-by-layer assembly of the system. 'Reflectometry with polarized neutrons is a perfect method to study thin magnetic films,' Lauter said. 'These thin films - if you put one on a substrate, you see it just like a mirror. However, this mirror has a very complicated internal multilayer structure. The neutrons look inside this complicated structure and characterize each and every interface. Due to the depth sensitivity of the method, we measure the structural and magnetic properties of each layer with the resolution of 0.5 nm. The neutron scattering results found that inserting LiF as a barrier significantly improves the quality of the interface, increasing the injection of electrons from the magnetic layer through the organic semiconductor in the spin valve and enhancing the overall properties of the system. In related work the magnetic properties of the cobalt film and the permalloy Ni{sub 80}Fe{sub 20} were characterized. Cobalt in particular needed attention, as it cannot be grown epitaxially (i.e., deposited) on an organic semiconductor film. Cobalt becomes polycrystalline or amorphous, and this affects its magnetic properties. The data from the first experiment showed that the cobalt layer in the system 'did not have typical magnetic properties,' Lauter said. 'The results showed that the cobalt had low magnetization. To improve the efficiency, the cobalt magnetization should be much higher. So this experiment helped us to improve the growth conditions and to get a cobalt layer with better magnetic properties.' In a subsequent experiment the researchers increased the magnetization of the cobalt, and a follow-up paper is in progress.

36 MATERIALS SCIENCE↗

Unveiling the Role of Critical Impurities in Spent LiFePO 4 Cathodes for Scalable Direct Regeneration

Direct regeneration offers a promising alternative to recycling End-of-Life (EoL) batteries by restoring metal elements and preserving the material structure, yet scaling these technologies to handle practical cathode black mass (CBM) with impurities remains challenging. Here, this study investigates the evolution of impurities, including aluminum (Al), polyvinylidene difluoride (PVDF) binder, and residual carbon (C), during direct recycling of spent LiFePO 4 (LFP) cathodes and their impact on electrochemical performance. Using various ex situ and in situ analyses, it is shown that the formation of lithium fluoride (LiF) during the traditional direct recycling process hinders lithium diffusion and deteriorates the reversible capacity. To address this major challenge, the combination of pH-controlled hydrothermal purification and the two-step sintering process is proposed effectively to regenerate spent LFP cathodes, eliminating the negative effect of Al and fluorine (F) impurities while mitigating any potential impacts of carbon residuals. The regenerated LFP from spent CBM achieves superior performance, retaining 152.5 mAh g −1 at 0.1 C and 133 mAh g −1 at 1 C with 98.7% capacity retention after 200 cycles. This approach is further validated using three distinct waste feedstocks from battery modules, enhancing impurity management and scalability in direct recycling. These findings present a sustainable and economically viable solution for large-scale LFP regeneration.

25 ENERGY STORAGE↗

Optimizing the 8 Li yield for the IsoDAR Neutrino Experiment

The focus of this paper is on optimizing the electron-antineutrino source for the IsoDAR (Isotope Decay at Rest) experimental program. IsoDAR will perform sensitive short-baseline neutrino oscillation and electroweak measurements, among other Beyond Standard Model searches, in combination with KamLAND and/or other suitable detectors. IsoDAR will rely on the high-Q β– decay of the 8 Li isotope for producing electron-antineutrinos, created mainly via neutron capture in an isotopically enriched 7 Li sleeve surrounding the Be target. In particular, this paper examines the performance, defined in terms of absolute 8 Li (or, equivalently, electron-antineutrino) production rate, of various candidate sleeve materials, including a lithium-fluoride, beryllium-fluoride mixture (“FLiBe”) sleeve and a homogeneous mixture of lithium and beryllium (“Li-Be”). Furthermore, these studies show that the 8 Li yield can be increased substantially by employing a Li-Be sleeve and therefore motivate significant changes to the nominal IsoDAR design.

47 OTHER INSTRUMENTATION↗

Unveiling the mechanisms of lithium dendrite suppression by cationic polymer film induced solid–electrolyte interphase modification

It is crucial to suppress lithium dendrite formation in lithium metal batteries. Formation of a good solid–electrolyte interphase (SEI) has been considered to be effective in limiting lithium dendrite growth. However, how the SEI may be modified during lithium deposition is hard to resolve due to challenges in in situ investigation of the SEI with fine details. Here, we report an in situ study that uncovers the lithium dendrite suppression mechanism arising from SEI modification by a poly(diallyldimethylammonium chloride) (PDDA) cationic polymer film, using electrochemical liquid cell transmission electron microscopy (TEM). Lithium nanogranules are obtained in the presence of the polymer film. Chemical mapping of the deposits provides remarkable details of the SEI on individual nanogranules. It shows that lithium fluorides are uniformly distributed within the inner SEI layer of individual lithium nanogranules, arising from the instantaneous reaction of the deposited lithium with PF 6 – ions accumulated by the cationic polymer film, and thus the dendritic growth of lithium is prohibited. The ability to directly measure SEI chemistry at the nanoscale down to the individual nanograins in situ and unveil its correlation with the lithium deposition behavior opens future opportunities to explore unsolved mechanisms in batteries.

25 ENERGY STORAGE↗

Refractive field correctors for the Starlab ultraviolet telescope

Field correctors for a one-meter, f/15 cassegrainian telescope were designed as part of a NASA-funded study of an astronomical obervatory on board of the Space Shuttle. By means of a Gasgoigne corrector and a biconcave field flattener, astigmatism and field curvature are corrected in a 0.6 deg field. Applicable wavelength ranges are limited by chromatic aberrations. The upper wavelength is selected to match a photocathode response limit. The lower wavelength limit is defined by a filter. Examples of usable wavelength ranges are: 210 nm - 1100 nm (multialkali photocathode, fused-silica corrector elements), 177 nm - 320 nm (cesium telluride photocathode, calcium fluoride correctors); and possibly 134 nm - 190 nm (cesium iodide photocathode, lithium fluoride correctors). Residual rms lateral color is smaller than 0.02 arc sec, and axial color is smaller than 0.25 arc sec (blur diameter at the ends of the wavelength range). The correctors introduce a small amount of coma. This is compensated by adjustment of the conic constants of the telescope mirrors.

Bottema, M.↗

Molten salt compositions with enhanced heat transfer and reduced corrosion properties

A heat transfer (exchange) composition comprising a halide salt matrix having dispersed therein nanoparticles comprising elemental carbon in the absence of water and surfactants, wherein said halide is fluoride or chloride, wherein the halide salt may be an alkali halide salt (e.g., lithium fluoride, sodium fluoride, potassium fluoride, rubidium fluoride, sodium chloride, potassium chloride, rubidium chloride, and eutectic mixtures thereof) or an alkaline earth halide salt (e.g., fluoride or chloride salt of beryllium, magnesium, calcium, strontium, or barium), and wherein the nanoparticles comprising elemental carbon may be solid or hollow, and wherein the composition may further include nanoparticles comprising a fissile material (e.g., U, Th, or Pu) dispersed within the composition. Molten salt reactors (MSRs) containing these heat transfer compositions in coolant loops in thermal exchange with a reactor core, as well operation of such MSRs, are also described.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Interim Report on the Optimization and Feasibility Studies for the Neutron Detection without Helium-3 Project

This report details the results of the work accomplished for the „Neutron Detection without Helium-3‟ project during the 2011 fiscal year. The primary focus of the project during this year was to develop models using alternatives to helium-3 to investigate the possibilities and optimizations for multiplicity counters in safeguards applications by computer simulations. The multiplicity counter with significant capability, the Epithermal Neutron Multiplicity Counter (ENMC), was used as the baseline requirement for alternative technologies, which, if a suitable alternative can be found, should also satisfy systems with less stringent requirements, including coincidence counters. The project is in collaboration with Los Alamos National Laboratory (LANL), and the baseline model of the ENMC that had been developed at LANL with helium-3 as the detector material was used as a starting point. The model was modified to support optimization investigations, and verified with the helium-3 base material. The model was then modified to incorporate boron-trifluoride (BF3) gas, which can be used as a proportional gas similar to helium-3. The BF3 gas however, cannot be operated at very high pressure, and therefore optimization were performed with lower pressures and involved changing the tube size and number. The simulation of this model is very similar in approach to the model with helium-3 where the simulation ends when the neutron is captured in the boron. The reaction products are easily detected in the proportional gas, and the simulation results of counting the number of reactions matches well with experimental data. Next, the tubes were replaced with boron-lined proportional tubes, where the neutron capture material is a thin boron lining inside the tube wall, and which use standard proportional counting gas. For this alternative, the simulation needs to extend beyond the neutron capture, and track the reaction products, which must exit the boron-lining into the counting gas. The reaction products do not always end up in the counting gas, depending on the boron-lining thickness and neutron capture depth. Methods to track the reaction products have been recently implemented into MCNPX and were verified by using several different approaches. The tube number and size were also varied for the boron-lined case. Finally, work has started on a model of an alternative using lithium-6, another material with a high cross-section for thermal neutron capture. The most promising approach is with lithium fluoride in a zinc sulfide (silver activated) scintillator medium. The neutron is captured in the lithium, and the reaction products trigger scintillation light in the zinc sulfide, which is subsequently detected by photo-multipliers by the use of light guides or fibers. The simulations were performed with the focus on determining the efficiency, which is critical when detecting 2 or 3 neutrons in coincidence, as well as the die-away time, which is a measure of the time required to capture neutrons in the system. The die away time is related to the coincident time gate needed for the system which drives the accidental coincident rate, the primary background or noise in this type of measurement. The usual figure of merit for coincidence type systems, the efficiency squared divided by the die-away time, was calculated for each variation simulated.

helium-3 alternatives↗

Experimental Results From the Thermal Energy Storage-1 (TES-1) Flight Experiment

The Thermal Energy Storage (TES) experiments are designed to provide data to help researchers understand the long-duration microgravity behavior of thermal energy storage fluoride salts that undergo repeated melting and freezing. Such data, which have never been obtained before, have direct application to space-based solar dynamic power systems. These power systems will store solar energy in a thermal energy salt, such as lithium fluoride (LiF) or a eutectic of lithium fluoride/calcium difluoride (LiF-CaF2) (which melts at a lower temperature). The energy will be stored as the latent heat of fusion when the salt is melted by absorbing solar thermal energy. The stored energy will then be extracted during the shade portion of the orbit, enabling the solar dynamic power system to provide constant electrical power over the entire orbit. Analytical computer codes have been developed to predict the performance of a spacebased solar dynamic power system. However, the analytical predictions must be verified experimentally before the analytical results can be used for future space power design applications. Four TES flight experiments will be used to obtain the needed experimental data. This article focuses on the flight results from the first experiment, TES-1, in comparison to the predicted results from the Thermal Energy Storage Simulation (TESSIM) analytical computer code.

Jacqmin, David↗

Atomistic modeling of LiF microstructure ionic conductivity and its influence on nucleation and plating

We report the formation and degradation of the solid electrolyte interphase (SEI) and its underlying transport properties play an essential role in the overall performance of lithium-ion batteries. This paper presents classical molecular dynamics studies on polycrystalline inorganic lithium fluoride (LiF) layers to model and predict the SEI transport properties. The ionic conductivity is obtained from the lithium-ion diffusivity in polycrystalline structures of LiF using the Nernst-Einstein relation. The predicted molecular dynamics data are used in a continuum scale phase-field model to evaluate the plating kinetics under fast charging conditions. The analysis emphasizes that the SEI ionic conductivity properties impact the plating dynamics, where SEI's low ion conductivity value is prone to large plating and subsequent capacity degradation. The combination of atomic and continuum scale studies shown herein lays a foundation to tune in SEI transport properties to decrease the amount of lithium plating and improve the performance of fast-charging batteries.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Analysis of a Radioisotope Thermal Rocket Engine

The Triton Hopper is a concept for a global hopper vehicle which uses a radioisotope rocket engine and In-situ propellant acquisition to explore the surface of Neptune's moon, Triton. The current Triton Hopper concept stores heated Nitrogen in a spherical tank to be used as the propellant. The aim of the research was to investigate the benefits of storing propellant at ambient temperature and heating it through the use of a thermal block during engine operation, as opposed to storing gas at a high temperature. Lithium, Lithium Fluoride and Beryllium were considered as possible materials for the thermal block. A heat energy analysis indicated that a lithium thermal mass would provide the highest heat energy for a temperature change from 900 Celsius to -100 Celsius. A heat transfer analysis was performed for Nitrogen at -100 Celsius flowing through 1000 passages inside a 1kg lithium thermal block at a temperature of 900 Celsius. The system was analyzed as turbulent flow through a tube with constant surface temperature. The analysis indicated that the propellant reached a maximum temperature of 877 Celsius before entering the nozzle. At this exit temperature, the average specific impulse [I(sub sp)] of the engine was determined to be 157s. Previous studies for the stored heated gas concept suggest that the engine would have an average I(sub sp) of approximately 52s. Thus, the use of a thermal block concept results in a 200 percent engine performance increase. In addition, a tank sizing study was performed to determine if the concept is feasible in terms of mass requirements. The mass for a spherical carbon fiber COPV storing 35kg of nitrogen at an initial temperature of -100 Celsius and a pressure of 1000psia, was determined to be 7.2kg. The specific impulse analysis indicated that the maximum engine performance is obtained for a mass ratio of 5kg of Nitrogen per every 1kg of lithium thermal mass. Thus for 35kg of Nitrogen the total thermal mass would be 7kg. This brings the total mass of the system to 49.2.kg which is less than the 56kg landing payload capacity of the Triton Hopper. Finally, an insulation analysis using 10mm of MLI insulation indicated that a total of 22 watts of heat are lost to the environment. With the heat loss known, the power required to heat the thermal mass to 900 Celsius in 24 days was determined to be 2.15 watts. The study's results allowed us to conclude that the thermal mass concept is the better option due to the performance increase provided, the low power requirement and its compliance with the landing mass requirement of the Triton Hopper.

Radioisotope↗

Reversible Intercalation of Fluoride-Anion Receptor Complexes in Graphite

We have demonstrated a route to reversibly intercalate fluoride-anion receptor complexes in graphite via a nonaqueous electrochemical process. This approach may find application for a rechargeable lithium-fluoride dual-ion intercalating battery with high specific energy. The cell chemistry presented here uses graphite cathodes with LiF dissolved in a nonaqueous solvent through the aid of anion receptors. Cells have been demonstrated with reversible cathode specific capacity of approximately 80 mAh/g at discharge plateaus of upward of 4.8 V, with graphite staging of the intercalant observed via in situ synchrotron X-ray diffraction during charging. Electrochemical impedance spectroscopy and B-11 nuclear magnetic resonance studies suggest that cointercalation of the anion receptor with the fluoride occurs during charging, which likely limits the cathode specific capacity. The anion receptor type dictates the extent of graphite fluorination, and must be further optimized to realize high theoretical fluorination levels. To find these optimal anion receptors, we have designed an ab initio calculations-based scheme aimed at identifying receptors with favorable fluoride binding and release properties.

electrolytes↗

Degradation Diagnostics from the Subsurface of Lithium-Ion Battery Electrodes

Despite the long-established rocking-chair theory of lithium-ion batteries (LIBs), developing novel characterization methodology with higher spatiotemporal resolution facilitates a better understanding of the solid electrolyte interphase studies to shape the reaction mechanisms. In this work, we develop a Xenon ion plasma focused ion beam (Xe + PFIB)-based characterization technique to probe the cross-sectional interface of both ternary cathode and graphite anode electrodes, with the focus on revealing the chemical composition and distribution underneath the electrode surface by in-depth analysis of secondary ions. Particularly, the lithium fluoride is detected in the pristine cathode prior to contact with the electrolyte, reflecting that the electrode degradation is in the form of the loss of lithium inventory during electrode preparation. This degradation is related to the hydrolysis of the cathode material and the decomposition of the PVDF binder. Here, through the quantitative analysis of the transition-metal degradation products, manganese is found to be the dominant element in the newly formed inactive fluoride deposition on the cathode, while no transition metal signal can be found inside the anode electrode. These insights at high resolution implemented via a PFIB-based characterization technique not only enrich the understanding of the degradation mechanism in the LIBs but also identify and enable a high-sensitivity methodology to obtain the chemical survey at the subsurface, which will help remove the capacity-fade observed in most LIBs.

25 ENERGY STORAGE↗

The surface triple-coupling on single crystalline cathode for lithium ion batteries

Single crystalline (SC) cathode materials, which are less susceptible to micro/nano-cracks formation and offer better structure stability compared to the polycrystalline counterpart, have attained great attention. However, the parasitic side reactions at the cathode-electrolyte interface induces the loss of active species, which consequently leads to continual degradation of the electrochemical performances. Herein, a triple coupling of concentration-gradient Na+, F- co-doping and surface NaF coating are exploited for the first time on SC LiNi 0.5C o 0.2 Mn 0.3 O 2 cathode by the hydrolysis of NaPF 6 . This process regulates the external structure of materials by constructing a “sandwich” configuration from surface to bulk: rock salt - mixing zone - layered phase. The detailed interface transformation mechanism is revealed by Neutron powder diffraction (NPD), spherical aberration corrected high-resolution scanning transmission electron microscopy (HR-STEM), electron energy loss spectroscopy (EELS), and Ar+ sputtering assisted X-ray photoelectron spectroscopy (XPS). The synergistic effects endow the SC cathode with outstanding capacity retentions: 91.3% at 25 °C and 85% at 45 °C, after 500 cycles at 5 C between 3.0 and 4.5 V. In addition, a high full-cell reversible capacity of 168.9 mAh g -1 with a capacity retention of 92.4% is achieved after 300 cycles at 1 C. Multiple characterizations further indicate that these superior results are mainly ascribed to the overall structure integrity of SC material, the thin cathode electrolyte interface, high content of lithium fluoride, and the low solubility of transition metal ions. This work opens a new avenue to construct a benign interface towards high-performance lithium ion batteries.

lithium ion batteries↗

Multi-modal characterization methods of solid-electrolyte interphase in silicon-graphite composite electrodes

Composite silicon-graphite (Si-Gr) anodes can improve battery energy density, due to Si's high gravimetric capacity, while mitigating mechanical degradation of the anode and solid-electrolyte interphase (SEI) caused by Si volumetric expansion. Optimizing these anodes is challenging, in part due to difficulty characterizing the SEI structure and composition. In this work, we present multi-modal characterization of the SEI on composite Si-Gr anodes to relate SEI chemical composition and structure to functional properties. Discrepancies in elemental concentrations from X-ray photoelectron spectroscopy, Auger electron spectroscopy, and energy-dispersive X-ray spectroscopy (EDS) are attributed to varying information depth and lateral resolution of the individual probes. However, by combining quantitative composition information with spatially resolved element mapping from scanning transmission electron microscopy, EDS, and electron energy loss spectroscopy, a holistic picture of the SEI emerges. We observe the bilayer SEI structure and a direct correlation between elemental Li and F, suggesting that most Li in the SEI exists as lithium fluoride (LiF). Further, LiF concentration is directly proportional to the maximum SEI resistivity, as determined by scanning spreading resistance microscopy. Lastly, there is an inverse relationship between lithium carbonate and LiF concentration in the SEI, providing insight into the detailed chemistry of SEI formation and evolution.

25 ENERGY STORAGE↗