A study of dynamic measurements made in the settling chamber of the Langley 0.3-meter transonic cryogenic tunnel

Tests have been conducted in a cryogenic wind tunnel settling chamber using a fast response instrumentation to measure the possible existence of temperature fronts due to a sudden or step change in the rate of liquid nitrogen injection into the circuit. No indications of such fronts were obtained using three different techniques to change the rate of nitrogen injection. The normalized pressure and velocity fluctuations at two total temperatures and over a large range of Mach numbers and Reynolds numbers were about 2 x 10 to the -7th to 2 x 10 to the -6th and about 1.8 to 3 percent, respectively. There was no evidence of liquid nitrogen droplets in the flow down to a total temperature of 140 K. The pressure fluctuation power spectra from a pressure transducer correlated with the fan blade passage through the eighth harmonic of the fundamental frequency.

Johnson, C. B.↗

Shape optimization and fluid control of near isothermal compressor for transcritical carbon dioxide cycle

The compressor holds great promise for enhanced energy efficiency over a wide range of vapor compression systems (VCS). However, the majority of them focused on liquid refrigerant injection or inter-stage cooling technologies to improve heat transfer. Increasing the heat transfer area provides another perspective to promote heat dissipation, which commonly involves shape optimization whilst bringing some limitations, mainly from the manufacturing side. To fill the research gap, this paper compares the performance of isothermal compressors under different compression chamber shapes and chamber connection configurations. Additionally, the fluid control of the liquid piston was combined with shape optimization to explore the potential for further heat transfer enhancement. The simulation results have demonstrated that the COP improvements can reach up to 9% compared with the baseline case by optimizing the chamber shape and properly controlling the liquid piston speed, which provides a guideline for designing and customizing the isothermal compression chamber.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Improved Cryostat for Cooling a Wide Panel

An improved cryostat has been developed for cooling a wide panel evenly over its surface to a temperature of -423 F (approximately equal to -253 C) by use of liquid helium. Originally, the cryostat was to be used in measuring apparent strains in wide aluminum/lithium panels as functions of temperature in order to develop data for temperature compensation of the readings of strain gauges on a tank containing liquid hydrogen. Relative to the cryostat used previously for this purpose, the improved cryostat can be prepared for a test in less time, and it loses less helium during each test. Each wide panel to be tested is instrumented with thermocouples in preparation for a test. The previous cryostat was made of two aluminum halves that, for each test, were sandwiched together and sealed around the instrumented wide panel to be tested. The panel was thus enclosed in a plenum. The cryostat and adjacent panel areas protruding from the cryostat were then coated with a thermally insulating foam. During a test, liquid helium was made to flow into the plenum through a port on the bottom. The helium vaporized and expanded, filling the plenum with cold helium gas, which eventually flowed out of the plenum through a port on the top. The nature of the flow was such that a significant portion of the helium did not come into contact with the wide panel; hence, cooling was less efficient than it might otherwise have been. After completion of each test, the foam and the cryostat were separated from the panel. The cryostat was cleaned and prepared for installation on another instrumented wide panel for the next test. It took 28 hours to install the cryostat onto the instrumented panel, apply the foam, and perform ancillary operations in preparation for a test. The volume of liquid helium consumed during each test was 750 liters. The improved cryostat (see figure) includes an upper section and a lower section, both of which include permanent housings made of a thermally insulating foam 2-in. (approximately equal to 5-cm) thick. A liquid-helium- injection manifold is attached to the inside of the top section. The bottom section includes an outlet for helium gas. The manifold contains slots that, when the cryostat is installed on the panel, are located approximately 1 in. (approximately equal to 2.5 cm) from the wide panel. The array of slots spans a substantial portion of the area of the panel. The top and bottom sections of the cryostat are sealed to the panel by use of polytetrafluoroethylene cord and aluminum tape. Liquid helium is fed into the manifold from the top. The helium leaves the manifold through the slots and thus impinges directly on the panel. Hence, all the helium entering the cryostat must come into contact with the panel before leaving the cryostat. After a test, the cryostat is removed from the panel and reinstalled onto another panel for the next test. Installation of the cryostat on an instrumented panel takes a negligible amount of time, in comparison with the 28 hours associated with the previous cryostat. The amount of liquid helium consumed during a test in the improved cryostat is 500 liters - 250 liters less than before.

Clifton, W. B.↗

Modeling of Water Injection into a Vacuum

A loosely coupled two-phase vacuum water plume model has been developed. This model consists of a source flow model to describe the expansion of water vapor, and the Lagrangian equations of motion for particle trajectories. Gas/Particle interaction is modeled through the drag force induced by the relative velocities. Particles are assumed traveling along streamlines. The equations of motion are integrated to obtain particle velocity along the streamline. This model has been used to predict the mass flux in a 5 meter radius hemispherical domain resulting from the burst of a water jet of 1.5 mm in diameter, mass flow rate of 24.2 g/s, and stagnation pressure of 21.0 psia, which is the nominal Orbiter water dump condition. The result is compared with an empirical water plume model deduced from a video image of the STS-29 water dump. To further improve the model, work has begun to numerically simulate the bubble formation and bursting present in a liquid stream injected into a vacuum. The technique of smoothed particle hydrodynamics was used to formulate this simulation. A status and results of the on-going effort are presented and compared to results from the literature.

Alred, John W.↗

Evaluation of centrifugal compressor performance with water injection

The effects of water injection on a compressor are presented. To determine the effects of varying water-air ratio, the compressor was operated at a constant equivalent impeller speed over a range of water-air ratios and weight flows. Operation over a range of weight flows at one water-air ratio and two inlet air temperatures was carried out to obtain an indication of the effects of varying inlet air temperature. Beyond a water-air ratio of 0.03 there was no increase in maximum air-weight flow, a negligible rise in peak total-pressure ratio, and a decrease in peak adiabatic efficiency. An increase in inlet air temperature resulted in an increase in the magnitude of evaporation. An analysis of data indicated that the magnitude of evaporation within the compressor impeller was small.

COMPRESSORS - RADIAL FLOW↗

Influence of living grass Roots and endophytic fungal hyphae on soil hydraulic properties

Soil hydraulic properties are often estimated based on laboratory data or pedotransfer functions dependent on soil physical properties, which often do not consider potential impacts of soil roots or fungal hyphae. Here, we first review current knowledge of how these soil biotic components affect hydraulic properties, then we conducted laboratory experiments to specifically test if the presence of roots and mycorrhizal fungi had a significant effect on the hydraulic properties of two soils with contrasting textures: Flint sand and Hamblen silt loam. Soil cores were seeded with (Panicum virgatum) and grown in a greenhouse over three separate growth periods. The endophytic fungus Serendipita indica was injected as liquid inoculant into designated mycorrhizal cores. Saturated hydraulic conductivity (K sat ) measurements were made with a constant head permeameter, and soil water retention curves were obtained by the evaporation method, supplemented at the dry end for Hamblen silt loam with water activity meter data. Retention curve parameters were obtained by fitting the van Genuchten equation to the resulting measurements. Mean root volume ratios were higher in the mycorrhizal inoculated treatment than in the uninoculated treatment for both soils. For Flint sand, analysis of variance revealed that K sat was reduced by the presence of roots as compared to bare soil. This was likely due to roots clogging soil pores. Results also indicated the presence of roots changed the shape of the water retention curve for Flint sand by increasing water content at saturation and by reducing the slope of the curve. These changes suggested roots created additional porosity and broadened the pore-size distribution. The presence of mycorrhizal fungi accentuated the root effects. The influence of roots and mycorrhizal fungi on hydraulic properties was less obvious for the Hamblen silt loam, as none of the treatments differed from each other at p < 0.05. The results highlight the necessity to consider the impact of root and fungal structures on models of soil hydraulic properties.

59 BASIC BIOLOGICAL SCIENCES↗

DNS of Flame Stabilization Dynamics of a Swirl-Stabilized Spray Burner Using Sustainable Aviation Fuels

Concern for emission reduction has motivated the development of new cost-effective alternative sustainable aviation fuels (SAFs). Drop-in SAFs with blends of the certified and the alternative fuels are beneficial because they do not require engine modifications for use in current aviation engines. Combustion characteristics are of particular concern when comparing a new fuel with Jet-A. Lean blow-off and flame stabilization have been identified to be governed by the fuel propensity to autoignition, i.e. derived cetane number. However, fundamental investigation is required to identify the impact of derived cetane number on the combustion mode of flame stabilization in a realistic combustor. The combustion mode has also a direct impact on turbulent combustion modeling closures. DNS simulations are performed in the low-Mach solver of the Pele Suite called PeleLMeX. Lagrangian multi-phase modeling is used to capture the liquid spray injection of Jet-A (reference fuel) and C1 as a representative of a low cetane number SAF. Adaptive Mesh Refinement (AMR) is used to enable a more efficient simulation of a more realistic domain size and embedded boundary treatment is used to model a bluff-body geometry. Local extinction and edge flame propagation were observed for both fuels. The edge flame propagation mode was quantified in terms of a Damkohler number defined as the ratio between progress variable reaction rate and its diffusive flux. Initial analysis suggests that a mixed mode combustion occurs for the edge flame propagation, with flame propagation assisted by ignition and autoignition co-existing for both Jet-A and C1 flames. The analysis of the extinction region shows a larger progress variable for Jet-A which can further increase the local displacement speed and present a faster reignition of the stoichiometric mixture fraction.

adaptive mesh refinement↗

An analysis of project high water data

Optical and radio frequency electromagnetic observations of high water release in ionosphere and atmospheric turbulence following liquid release in space

HIGH WATER PROJECT↗

Design features and operational characteristics of the Langley 0.3-meter transonic cryogenic tunnel

Experience with the Langley 0.3 meter transonic cryogenic tunnel, which is fan driven, indicated that such a tunnel presents no unusual design difficulties and is simple to operate. Purging, cooldown, and warmup times were acceptable and were predicted with good accuracy. Cooling with liquid nitrogen was practical over a wide range of operating conditions at power levels required for transonic testing, and good temperature distributions were obtained by using a simple liquid nitrogen injection system. To take full advantage of the unique Reynolds number capabilities of the 0.3 meter transonic tunnel, it was designed to accommodate test sections other than the original, octagonal, three dimensional test section. A 20- by 60-cm two dimensional test section was recently installed and is being calibrated. A two dimensional test section with self-streamlining walls and a test section incorporating a magnetic suspension and balance system are being considered.

Kilgore, R. A.↗

Advanced cooling techniques for high-pressure hydrocarbon-fueled engines

The regenerative cooling limits (maximum chamber pressure) for 02/hydrocarbon gas generator and staged combustion cycle rocket engines over a thrust range of 89,000 N (20,000lbf) to 2,669,000 N (600,000 lbf) for a reusable life of 250 missions were defined. Maximum chamber pressure limits were first determined for the three propellant combinations (O2/CH4, O2/C3H8, and O2/RP-1 without a carbon layer (unenhanced designs). Chamber pressure cooling enhancement limits were then established for seven thermal barriers. The thermal barriers evaluated for these designs were: carbon layer, ceramic coating, graphite liner, film cooling, transpiration cooling, zoned combustion, and a combination of two of the above. All fluid barriers were assessed a 3 percent performance loss. Sensitivity studies were then conducted to determine the influence of cycle life and RP-1 decomposition temperature on chamber pressure limits. Chamber and nozzle design parameters are presented for the unenahanced and enhanced designs. The maximum regenerative cooled chamber pressure limits were attained with the O2/CH4 propellant combination. The O2/RP-1 designs relied on a carbon layer and liquid gas injection chamber contours, short chamber, to be competitive with the other two propellant combinations. This was attributed to the low decomposition temperature of RP-1.

Cook, R. T.↗

Estimation of fan pressure ratio requirements and operating performance for the National Transonic Facility

The National Transonic Facility (NTF), a fan-driven, transonic, pressurized, cryogenic wind tunnel, will operate over the Mach number range of 0.10 to 1.20 with stagnation pressures varying from 1.00 to about 8.8 atm and stagnation temperatures varying from 77 to 340 K. The NTF is cooled to cryogenic temperatures by the injection of liquid nitrogen into the tunnel stream with gaseous nitrogen as the test gas. The NTF can also operate at ambient temperatures using a conventional chilled water heat exchanger with air on nitrogen as the test gas. The methods used in estimating the fan pressure ratio requirements are described. The estimated NTF operating envelopes at Mach numbers from 0.10 to 1.20 are presented.

Gloss, B. B.↗