Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “LIFE DETECTOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

TU-F-18A-08: Effect of Quantum Detection Efficiency and Energy Bin Selection On Contrast-To-Noise-Ratio for Energy-Resolved Photon-Counting Detectors

Purpose: Energy-resolved photon-counting detectors have the capability to discriminate photons according to their energies. By using optimal energy weighting factors, the contrast-to-noise-ratio (CNR) of the reconstructed image can be improved. In this work, we investigate how quantum detection efficiency (QDE) affects the determination of the optimal energy threshold bins, and therefore the CNR improvement of photon-counting detectors. Methods: In this simulation study a photon-counting detector, based on Silicon (Si), was investigated. A task-oriented algorithm was used to determine the optimal energy bin setting in order to maximize CNR. Projection-based and Image-based energy weighting techniques were implemented. A 13 mm PMMA phantom with two contrast materials, hydroxyapatite (HA) and iodine (I), at different concentrations (100, 200, and 300 mg/mL for HA and 2, 4, and 8 mg/mL for I) was used. TASMIP algorithm was used to generate the spectrum with 2.7 mm Al filter. Different tube voltages, number of energy bins, and bin widths were investigated. Different thicknesses of Si were also investigated to determine the QDE effect on CNR. Results: CNR increased as the detector material thickness increased until it reached 30 mm for Si thickness such that the CNR value was near to the value predicted by an ideal detector. Also, the results indicated that the improvement of CNR due to the QDE is task-dependent when comparing weighted images to photon-counting images. For hydroxyapatite the improvement is approximately 20%, whereas for iodine it is less than 10%. Conclusion: The results showed that the improvement of CNR for an energy-resolved photon-counting detector is highly task-dependent when QDE is taken into account.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Search for double beta processes in {sup 106}Cd with enriched {sup 106}CdWO{sub 4} crystal scintillator in coincidence with four crystals HPGe detector

A radiopure cadmium tungstate crystal scintillator, enriched in {sup 106}Cd ({sup 106}CdWO{sub 4}), was used to search for double beta decay processes in {sup 106}Cd in coincidence with an ultra-low background set-up containing four high purity germanium (HPGe) detectors in a single cryostat. The experiment has been completed after 13085 h of data taking. New improved limits on most of the double beta processes in {sup 106}Cd have been set on the level of 10{sup 20}−10{sup 21} yr. Tn particular, the half-life limit on the two neutrino electron capture with positron emission, T{sub 1/2} ≥ 1.8 × 10{sup 21} yr, reached the region of theoretical predictions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Complementary studies of T=2 {sup 30}Al and the systematics of intruder states

Low-spin states were studied in {sup 30}Al following the {beta} decay of {sup 30}Mg produced in the fragmentation of 140-MeV/AMU {sup 48}Ca. Analysis of the {beta}-{gamma} and {beta}-{gamma}-{gamma} coincidences revealed a new 1{sup +} state at 2413 keV, confirmation of the level scheme, and a more accurate half-life measurement of 315(6) ms for the {sup 30}Mg ground state. Higher-spin states were investigated in the reaction of {sup 14}C on {sup 18}O at 22 MeV. Protons and deuterons were detected in a segmented E-{delta}E Si telescope in coincidence with one or two {gamma} rays in the FSU Ge detector array. A comparison of the resulting level and decay scheme with predictions of the sd shell model shows good agreement with all but six of the states in both excitation energy and {gamma}-decay branching ratios. The root-mean-square deviations in energy of these states using the older USD and newer USDA and USDB interactions were 265, 176, and 173 keV, respectively. The remaining six states are well described as 4{sup -} to 7{sup -} states, similar in relative energy to those in {sup 28}Al but shifted down by about 1200 keV. These states also agree well with the predictions of shell-model calculations using the WBP interaction. A comparison of the lowest 4{sup -} states in even A Na, Al, and P isotopes shows a systematic decrease in energy with increasing N and with decreasing Z. The energies of the 4{sup -} states are almost identical in nuclei with the same N-Z values.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The Majorana Demonstrator radioassay program

The Majorana collaboration is constructing the Majorana Demonstrator at the Sanford Underground Research Facility at the Homestake gold mine, in Lead, SD. The apparatus will use Ge detectors, enriched in isotope 76 Ge, to demonstrate the feasibility of a large-scale Ge detector experiment to search for neutrinoless double beta decay. The long half-life of this postulated process requires that the apparatus be extremely low in radioactive isotopes whose decays may produce backgrounds to the search. The radioassay program conducted by the collaboration to ensure that the materials comprising the apparatus are sufficiently pure is described. The resulting measurements from gamma-ray counting, neutron activation and mass spectroscopy of the radioactive-isotope contamination for the materials studied for use in the detector are reported. In conclusion, we interpret these numbers in the context of the expected background for the experiment.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

New segmented target for studies of neutron unbound systems

The study of neutron-unbound systems using invariant mass spectroscopy is often performed using low-intensity radioactive ion beams. Low reaction yields can be countered by using thick targets but at the expense of larger uncertainties in the reconstructed invariant mass. In this work, we present a new segmented target designed to address this trade-off. It is composed of three mm thick passive beryllium targets interleaved between four thick position sensitive silicon detectors. In the first experiment to use this new system the half-life of two-neutron unbound was measured to be (stat) (syst) ps, which agrees with a previous measurement made by the MoNA Collaboration.

47 OTHER INSTRUMENTATION↗

Cosmogenic 137 Xe Analysis of Alternatives for nEXO

Neutrinoless double-beta decay is a hypothetical nuclear decay in which two matter particles are produced without corresponding antimatter particles. Observation of neutrinoless double-beta decay would shed light on a potential explanation of matter-antimatter observed in the universe and also indicate the Majorana nature of neutrinos, meaning that the neutrino can act as its own antiparticle. The nEXO experiment is a proposed 5-ton liquid xenon time projection chamber detector with a projected 1.35 × 10 28 yr half-life sensitivity to neutrinoless double-beta decay in 136 Xe [J. Phys. G 49, 015104 (2022)]. While nEXO has a baseline location of SNOLAB, there are several other underground facilities in the world capable of hosting the experiment. The primary change at each site will be cosmogenic 137 Xe backgrounds, caused by varied cosmogenic muon activity at each site. This study finds that while there is a negligible increase in nEXO’s half-life sensitivity at 90% C.L. from improving the cosmogenic 137 Xe veto rejection procedure for SNOLAB, much higher daily muon rates at three other sites will have an adversely negative effect on nEXO’s sensitivity and would likely require further modifications to nEXO’s baseline design to reach nEXO’s scientific goals. Monte Carlo simulations of muons inducing 137 Xe backgrounds were conducted at four underground sites, SNOLAB, SURF, LNGS, and WIPP, each with roughly a factor of 10 times higher daily muon activity than the previous site. There were two primary inputs to these simulations. The first was sample data of cosmogenic muon flight through nEXO’s outer detector, a 12.8m tall and 12.3m wide cylindrical water tank lined with photomultiplier tubes to detect Cerenkov radiation, and all of the secondary interactions produced in the detector. The second input was a parametrization of 137 Xe* production tagging when 137 Xe de-excites and release prompt gammas, as well as accidental tagging caused by neutron capture on 63 Cu, 65 Cu, 19 F, and 1 H throughout the detector. Together, the number of backgrounds relative to the previous 2021 Sensitivity Paper [J. Phys. G 49, 015104 (2022)] was found at each of these four sites across three energy windows, from 400, 1400, and 2600 keV all up to 4600 keV, just above the end point of the prompt gamma spectrum for 137 Xe*. Using level curves for the sensitivity as 137 Xe backgrounds scale relative to baseline calculations, the half-life sensitivity at 90% C.L. for each of trial was found. Even with reduced 137 Xe backgrounds, the results for SNOLAB yielded neglible improvements in nEXO’s predicted sensitivity. On the contrary, the increased backgrounds for the three other considered sites yielded sensitivity estimates below nEXO’s previous projections. This study demonstrates that the shielding from cosmogenic muons at SNOLAB makes it highly preferred even amongst other world leading underground laboratories.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Improved Value for the Gamow-Teller Strength of the Sn100 Beta Decay

A record number of Sn100 nuclei was detected and new isotopic species toward the proton dripline were discovered at the RIKEN Nishina Center. Decay spectroscopy was performed with the high-efficiency detector arrays WAS3ABi and EURICA. Both the half-life and the β-decay end point energy of Sn100 were measured more precisely than the literature values. The value and the uncertainty of the resulting strength for the pure 0+→1+ Gamow-Teller decay was improved to BGT=4.4-0.7+0.9. A discrimination between different model calculations was possible for the first time, and the level scheme of In100 is investigated further. © 2019 American Physical Society.

60 APPLIED LIFE SCIENCES↗

Radon Photoionization: Project Technical Report

In most low-background physics experiments, radon is a significant and problematic source of background radiation because it is inert and sufficiently long-lived to pervade laboratory spaces. It may be possible to manipulate (and thus mitigate) radon electromagnetically by taking advantage of its relatively low first ionization energy. When considering ambient-temperature gas phases, only iodine is comparable. The other noble gases, and the most important constituents of breathable air (nitrogen and oxygen), all have higher ionization energies; so it may be possible to selectively manipulate radon in a variety of gas streams by ionizing it with an appropriately low-energy source of photons. Radon’s first ionization energy is in the vacuum UV part of the electromagnetic spectrum, which can be produced using a deuterium lamp. In this report, we present our attempts to manipulate radon via UV photoionization in a laboratory setting. This approach has the potential to increase radon removal efficiency from gases and/or to improve the efficiency of radon detectors. Unfortunately, our experiments suggest that either the life-time of a photoionized radon ion (before it re-neutralizes) is too short to be of much practical use and/or that our low-cost UV-photon source was not sufficiently energetic for efficient photoionization of radon.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

First biological and dosimetric results of the free flyer biostack experiment AO015 on LDEF

The main objectives of the Biostack Experiment are to study the effectiveness of the structured components of the cosmic radiation to bacterial spores, plant seeds, and animal cysts for a long duration spaceflight and to get dosimetric data such as particle fluences and spectra and total doses for the Long Duration Exposure Facility orbit. The configuration of the experiment packages allows the localization of the trajectory of the particles in each biological layer and to correlate the potential biological impairment or injury with the physical characteristics of the responsible particle. Although the Biostack Experiment was designed for a long duration flight of only nine months, most of the biological systems show a high hatching or germination rate. Some of the first observations are an increase of the mutation rate of embryonic lethals in the second generation of Arabidopsis seeds, somatic mutations, and a reduction of growth rates of corn plants and a reduction of life span of Artemia salina shrimps. The different passive detector systems are also in a good shape and give access to a proper dosimetric analysis. The results are summarized, and some aspects of future analysis are shown.

Reitz, G.↗

A system to measure isomeric state half-lives in the 10 ns to 10 μs range

The Isomeric State Measurement System (SISMEI) was developed to search for isomeric nuclear states produced by fusion-evaporation reactions. The SISMEI consists of 10 plastic phoswich telescopes, two lead shields, one NaI(Tl) scintillation detector, two Compton suppressed HPGe γ-ray detectors, and a cone with a recoil product catcher. The new system was tested at the 8 UD Pelletron tandem accelerator of the University of São Paulo with the measurement of two known isomeric states: {sup 54}Fe, 10{sup +} state (E = 6527.1 (11) keV, T{sub 1/2} = 364(7) ns) and the 5/2{sup +} state of {sup 19}F (E = 197.143 (4) keV, T{sub 1/2} = 89.3 (10) ns). The results indicate that the system is capable of identifying delayed transitions, of measuring isomeric state lifetimes, and of identifying the feeding transitions of the isomeric state through the delayed γ-γ coincidence method. The measured half-life for the 10{sup +} state was T{sub 1/2} = 365(14) ns and for the 5/2{sup +} state, 100(36) ns.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improved limits on {beta}{sup +}EC and ECEC processes in {sup 112}Sn

Limits on {beta}{sup +}EC and ECEC processes in {sup 112}Sn have been obtained using a 380 cm{sup 3} HPGe detector and an external source consisting of 100 g enriched tin (94.32% of {sup 112}Sn). A limit with 90% C.L. on the {sup 112}Sn half-life of 1.3x10{sup 21} yr for the ECEC(0{nu}) transition to the 0{sub 3}{sup +} excited state in {sup 112}Cd (1871 keV) has been established. This transition has been discussed in the context of a possible enhancement of the decay rate. The limits on other {beta}{sup +}EC and ECEC processes in {sup 112}Sn have also been obtained on the level of (0.1-1.6)x10{sup 21} yr at the 90% C.L.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Exploring the Impact of Nuclear Data Uncertainties in Ultra-high Resolution Gamma Spectroscopy for Isotopic Analysis Using Approximate Bayesian Computation

High purity germanium (HPGe) currently provides the highest readily available resolution gamma detection for a broad range of radiation measurements, but microcalorimetry is a developing option that has considerably higher resolution even than HPGe. Superior microcalorimetry resolution offers the potential to better distinguish closely spaced X-rays and gamma-rays, a common challenge for the low energy spectral region near 100 keV from special nuclear materials, and the higher signal-to-background ratio also confers an advantage in detection limit. As microcalorimetry continues to develop, it is timely to assess the impact of uncertainties in detector and item response functions and in basic nuclear data, such as branching ratios and half-lives, used to interpret spectra in terms of the contributory radioactive isotopes. We illustrate that a new inference option known as approximate Bayesian computation (ABC) is effective and convenient both for isotopic inference and for uncertainty quantification for microcalorimetry. The ABC approach opens a pathway to new and more powerful implementations for practical applications than currently available.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

β-decay spectroscopy for the r-process nucleosynthesis

Series of decay spectroscopy experiments, utilizing of high-purity Ge detectors and double-sided silicon-strip detectors, have been conducted to harvest the decay properties of very exotic nuclei relevant to the r-process nucleosynthesis at the RIBF. The decay properties such as β-decay half-lives, low-lying states, β-delayed neutron emissions, isomeric states, and possibly Q{sub β} of the very neutron-rich nuclei are to be measured to give significant constraints in the uncertainties of nuclear properties for the r-process nucleosynthesis. Recent results of βγ spectroscopy study using in-flight fission of {sup 238}U-beam will be presented together with our future perspectives.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Half-life of Ge 71 and the gallium anomaly

Recent discussions about the origin of the so-called gallium anomaly have motivated a remeasurement of the half-life of 71 Ge. Here, we have conducted three separate measurements using dedicated planar Ge detectors—one with 55 Fe as a standard, one with 57 Co as a standard, and one standalone 71 Ge measurement. Our results yield a half-life of 11.468±0.008 days, which is consistent with, but significantly more precise than, the currently accepted value. With this experiment, the potential explanation of the gallium anomaly being due to an unexpectedly long 71 Ge half-life has been ruled out, leaving the anomaly's origin as an open question.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

β − decay of exotic P and S isotopes with neutron number near 28

β - decay of very neutron-rich isotopes of P and S, studied at the National Superconducting Cyclotron Laboratory (NSCL) using the Beta Counting Station (BCS) consisting of a Double Sided Strip Detector surrounded by clovers detectors for observing delayed γ transitions is reported here. β-decay half-lifes and delayed neutron emission probabilities were extracted for 42,43,44 P and 44,46 S by analyzing spatial and temporal correlations between implants and decay events in the Si detector with further coincidence with γ transitions. Detection of delayed γ rays allowed for the identification of negative parity 1p1h states in 42 S for the first time, also constraining the parent ( 42 P) spin/parity to 2 - or 3 - . For the most exotic isotope studied, 46 S, no strong γ transition was observed unlike lighter even-even S isotopes, thus implying the shift of Gamow Teller (GT) strength distribution to higher energies. In conclusion, comparison of experimental observations to detailed shell-model calculations using the SDPFSDG-MU interaction allowed us to infer the importance and role of First Forbidden (FF) β transitions as the neutron number approaches and then exceeds N = 28.

39 ≤ A ≤ 58↗

Results of the LEGEND-200 experiment in the search for $0νββ$ decay

The LEGEND experiment is looking for the extremely rare neutrinoless double beta (0νββ) decay of 76 Ge using isotopically-enriched high-purity germanium (HPGe) detectors. The detection of this process would imply that the neutrino is a Majorana particle and the total lepton number would not be conserved, which could be related to the cosmological asymmetry between matter and antimatter through leptogenesis. The long-term goal of the collaboration is LEGEND-1000: a 1-ton detector array planned to run for 10 years, with a projected half-life sensitivity exceeding 10 28 years, fully covering the inverted neutrino mass hierarchy. A first search for the 0νββ decay has been carried out by LEGEND-200 building on the experience gained from GERDA and the MAJORANA DEMONSTRATOR. The experiment has been collecting physics data for a year at the Gran Sasso National Laboratory in Italy with 140 kg of HPGe detectors. With a total exposure of 61 kg yr, LEGEND-200 has achieved a background index of $5_{−2}^{+3}$ × 10 −4 counts/(keV kg yr) in the 0νββ decay signal region from the highest performing detectors. After combining the results from GERDA, the MAJORANA Demonstrator and LEGEND-200, an exclusion sensitivity > 2.8 × 10 26 yr has been obtained at 90% confidence level for the 0νββ decay half-life, with no evidence for a signal. A new observed lower limit of $T_{1/2}^{0v} >$ 1.9 × 10 26 yr at 90% confidence level has been established.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Cervical SPECT Camera for Parathyroid Imaging

Primary hyperparathyroidism characterized by one or more enlarged parathyroid glands has become one of the most common endocrine diseases in the world affecting about 1 per 1000 in the United States. Standard treatment is highly invasive exploratory neck surgery called Parathyroidectomy. The surgery has a notable mortality rate because of the close proximity to vital structures. The move to minimally invasive parathyroidectomy is hampered by the lack of high resolution pre-surgical imaging techniques that can accurately localize the parathyroid with respect to surrounding structures. We propose to develop a dedicated ultra-high resolution (~ 1 mm) and high sensitivity (10x conventional camera) cervical scintigraphic imaging device. It will be based on a multiple pinhole-camera SPECT system comprising a novel solid state CZT detector that offers the required performance. The overall system will be configured to fit around the neck and comfortably image a patient.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Experimental study of double-{beta} decay modes using a CdZnTe detector array

An array of sixteen 1 cm{sup 3} CdZnTe semiconductor detectors was operated at the Gran Sasso Underground Laboratory (LNGS) to further investigate the feasibility of double-{beta} decay searches with such devices. As one of the double-{beta} decay experiments with the highest granularity the 4x4 array accumulated an overall exposure of 18 kg days. The setup and performance of the array is described. Half-life limits for various double-{beta} decay modes of Cd, Zn, and Te isotopes are obtained. No signal has been found, but several limits beyond 10{sup 20} years have been performed. They are an order of magnitude better than those obtained with this technology before and comparable to most other experimental approaches for the isotopes under investigation. An improved limit for the {beta}{sup +}/EC decay of {sup 120}Te is given.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗