Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “LANL”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Recent progress towards incorporating radiochemical analysis in LANL ASC codes

This document summarizes the recent progress towards incorporating charged-particle radiochemical (RadChem) analysis in different LANL codes within the Advanced Scientific Computing (ASC) Program. The first section is focused on xRAGE and the implementation of the necessary physics packages to build an in-line RadChem capability. The second section provides a summary of the current RadChem postprocessing capabilities.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Environmental Air Monitoring at LANL: 2023 External Program Assessment [Slides]

Radioactive Air Emissions Management evaluates radiological impacts of LANL operations on members of the public, identifies and quantifies releases, and assesses impacts. It is not directly affiliated with cleanup operations or programmatic work and has independent oversight. The focus areas in Environmental Compliance Programs are stack emissions measurements, ambient air measurements, minor source operations evaluations, data management and quality assurance, collaboration with Meteorology program, and collaboration with Dose Assessment program (EPC-ES).

54 ENVIRONMENTAL SCIENCES↗

LANL & SPO Overview for SCGSR [Slides]

In 1943, Los Alamos National Laboratory was founded with a single, urgent purpose: to build an atomic bomb. Today, LANL focuses on maintaining a strategic nuclear deterrent to protect the nation’s security.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

LANL Interactive Display (LID) - DC Vault Updates and FY24 proposals

The LANL Interactive Display (LID) is an interactive touchscreen with a custom-built application designed to provide a geographic-based, virtual tour of the Laboratory’s organizations, facilities, programs, products, and capabilities. The Display is mounted on a portable stand and displayed in the classified vault of the Forrestal Building in Washington, D.C. The October 2023 updates include the latest inputs, including the addition of Nuclear Security Enterprise (NSE) information. Other major upgrades are detailed below.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Multi-probe meeting with Harwell II: A discussion of potential areas of cooperation for mutual benefit by the LANL Multi-probe Radiography team [Slides]

In this presentation, we continue a discussion begun in September 2023, with staff from the University of Manchester and the Central Laser Facility-Harwell in the UK exploring the possibilities for cooperative work of mutual interest in the technology underpinning petawatt laser driven Multi-Probe radiography. Since the September Seminar, the US and UK staff have exchanged lists of ideas for possible cooperation and this presentation comprises brief descriptions of five topics that LANL staff would offer for consideration in the area of laser driven radiation sources, applications of machine learning and experiments at Omega (in the US) and Gemini (in the UK).

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The LANL Common Modeling Framework (CMF) [Slides]

The Common Modeling Framework is a modern software repository built and maintained by the LANL Weapons Physics Directorate (ALDX). ALDX’s mission space is to develop and apply cutting-edge theory, computational models, and multi-physics simulation codes, and to design, execute, and analyze complex experiments

97 MATHEMATICS AND COMPUTING↗

EPCAPE-Partitioning Thrust-Los Alamos National Laboratory (EPCAPE-PT-LANL) Field Campaign Report

Coastal cities offer a unique environment for studying aerosol-cloud interactions and the effects of urban emissions on aerosol and cloud properties. As part of the U.S. Department of Energy Atmospheric Radiation Measurement (ARM)’s Eastern Pacific Cloud Aerosol Precipitation Experiment (EPCAPE), the Partitioning Thrust by Los Alamos National Laboratory (EPCAPE-PT-LANL) was conducted to complement the science goals of EPCAPE and add additional in-depth measurements of aerosols and clouds at Mt. Soledad. Our campaign focused on measuring the physical, optical, and chemical properties of aerosols, trace gases, and their interactions within marine stratocumulus clouds in La Jolla, California (see Figure 1).

54 ENVIRONMENTAL SCIENCES↗

Innovative fix at LANL keeps pit production milestones in sight

Los Alamos National Laboratory (LANL) is well on the path to the W87-1 plutonium pit first production unit. When a piece of equipment in the Plutonium Facility (PF-4) went down in May, teams across the Laboratory who support work in PF-4 rallied to develop an innovative fix.

42 ENGINEERING↗

LANL Meteorological Program: 2023 Data Completeness/Quality Report

Los Alamos National Laboratory (LANL) operates seven mesa-top instrumented meteorology towers: Technical Area (TA) 6, TA-49, TA-53, TA-54, TA-63, TA-54B, and TA-16B. An additional instrumented tower is located in Mortandad Canyon (TA-5 MDCN), and there is a rain gauge at North Community (NCOM), located within the town of Los Alamos. The 10 meter (m) towers at TA-63, TA-54B, and TA-16B have been in testing since they were installed in 2021, and will be included in a future data completeness report. A description of the meteorology monitoring network, prior to the installation of the TA-63, TA-54B, and TA-16B is found in Dewart and Boggs (2014). Four of the mesa-top towers (e.g., TA-6, TA-49, TA-53, and TA-54) are instrumented at the 1.2 m, 11.5 m, 23 m, and 46 m levels. In addition, the TA-6 tower is instrumented at the 92 m level. The TA-5 MDCN tower is 10 m in height and is instrumented at 1.2 m and 10 m. Data are collected and averaged every 15 minutes. Range checking is performed on each measurement every 15 minutes; data that are beyond normal ranges are eliminated from the data set and replaced by a code for missing data. In addition, data are reviewed weekly by qualified meteorologists to identify bad data not identified by the range checking technique. The data steward eliminates these data from the data set and replaces them with a code for missing data. The instrument technicians also review that data and schedule instrument replacement, as required. All instruments are calibrated at a frequency that meets the criteria identified in ANSI/ANS-3.11-2015. Data completeness is determined by the number of total 15-minute records available versus the number of possible measurements for the entire year. As a rule, the meteorologists do not attempt to estimate data that are eliminated as bad data. Original datalogger records, including bad data, can be recalled from program archival storage.

54 ENVIRONMENTAL SCIENCES↗

LANL Meteorology Program Self-Assesment 2024 Update

The DOE Meteorological Coordinating Council (DMCC) conducted an initial LANL Meteorological (Met) Program Assist Visit in August 2006 (DMCC 2006). A follow-up assist visit in August 2015 assessed progress (DMCC 2015), and in June 2023, the DOE Meteorological Subcommittee (DMSC), successor to the DMCC, conducted a second follow-up assist visit (DMSC 2023), in which the Met Program was evaluated relative to the following 8 high-level questions.

54 ENVIRONMENTAL SCIENCES↗

Sensitivity/Uncertainty Comparison Study Involving IRSN, LANL, and ORNL Tools to Support Validation [Abstract]

Under a DOE Nuclear Criticality Safety Program (NCSP) task involving Analytical Methods, three Laboratories collaborated in a comparison of results obtained from Sensitivity/Uncertainty (S/U) packages relevant to validation of transport codes. The task involves Institut de Radioprotection et de Sûreté Nucléaire (IRSN), Los Alamos National Laboratory (LANL), and Oak Ridge National Laboratory (ORNL) comparing results of MORET 5/MACSENS V3.0, MCNP6.2/Whisper-1.1, and SCALE 6.2.3/TSUNAMI/USLSTATS respectively. All Monte Carlo transport code results utilize nuclear data from ENDF/B-VII.1 evaluation.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Sensitivity/Uncertainty Comparison Study Involving IRSN, LANL, and ORNL Tools to Support Validation

Under a DOE Nuclear Criticality Safety Program (NCSP) task involving Analytical Methods, three Laboratories collaborated in a comparison of results obtained from Sensitivity/Uncertainty (S/U) packages relevant to validation of transport codes. The task involves Institut de Radioprotection et de Sûreté Nucléaire (IRSN), Los Alamos National Laboratory (LANL), and Oak Ridge National Laboratory (ORNL) comparing results of MORET 5/MACSENS V3.0, MCNP6.2/Whisper-1.1, and SCALE 6.2.3/TSUNAMI/USLSTATS respectively. All Monte Carlo transport code results utilize nuclear data from ENDF/B-VII.1 evaluation. This study examines five cases from the International Handbook of Evaluated Criticality Safety Benchmark Experiments (ICSBEP Handbook) selected as application models: IEU-MET- FAST-002-001, LEU-COMP-THERM-001-001, LEU-SOL-THERM-004-001, MIX-COMP- THERM-001-001, and U233-SOL-THERM-001-001. This is a continuation of a previous study to examine Pu and HEU cases: HEU-MET-FAST-013-001, HEU-SOL-THERM-001-008, PU-MET- FAST-022-001, and PU-SOL-THERM-001-001. Ultimately, comparison is made between Upper Subcritical Limits (USLs) obtained using each code package for each application case. Since differences exist in whether packages take into account margin of subcriticality (MOS), the USL is computed using only bias and bias uncertainty, also known as the calculational margin (CM) in ANSI/ANS-8.24. Results comparison appears to show that benchmark selection has a greater influence on the USL than the method used for calculation of bias and bias uncertainty.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Molecular theory capability: LANL-PEM-Atomic implements universal descriptions of molecular photoionization

Photoionization of atomic ions, the process through which atoms in bound states absorb radiation by losing electrons, is a vital part of describing radiative transfer in mission-relevant dynamics. The photoionization of molecules dominates radiative transfer of ultraviolet (UV) and extreme UV (EUV) radiation in colder atmospheres (temperature < 30,000 degrees Kelvin). Consequently, air, which is quite transparent to our eyes (i.e., in the visible frequency regime) is remarkably opaque to radiation in much of the UV and EUV frequency regimes. This opacity makes air and other gas systems quite efficient at absorbing UV and EUV radiation, which heats the gas until ionization makes it transparent. This effect is important in describing a host of relevant phenomena, ranging from charge separation in high-altitude nuclear events and the dynamics of a nuclear fireball to the electrostatic discharges (sparks) that complicate weapons disassembly at Pantex.

74 ATOMIC AND MOLECULAR PHYSICS↗

LANL-TAMUS Graduate Fellowship Report

The goal of this project is to conduct analysis of 147 Sm neutron transmission (n,tot) data at DICER alongside previously collected neutron capture (n,γ) data and report updated resonance parameters and spins. Measurement and analysis of neutron-capture data, without neutron transmission data, has been conducted before and showed that the gamma widths, Γ γ , and neutron widths, Γn, both deviate from the distributions predicted by well-established theory. Γ γ is expected to follow a narrow Gaussian distribution independent of energy but instead a broadening of the distribution around 350 eV incident neutron energy was observed (P. E. Koehler et al. Phys. Rev. C 108, 142502 (2012)). Γ n is predicted to follow a chi-squared distribution with one degree of freedom known as the Porter-Thomas distribution but this prediction also failed above 350 eV incident neutron energy (P. E. Koehler et al. Phys. Rev. C 76, 025804 (2007)). This project seeks to reassess this past measurement by including neutron transmission data and simultaneously analyzing them alongside the neutron capture data to extract the most accurate measure of Γ γ and Γ n ever taken for the resonances of 147 Sm and see if theory holds or fails under a more refined measurement with newer data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗