Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Ion range”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Ion trap long-range XY model for quantum state transfer and optimal spatial search

Abstract Linear ion trap chains are a promising platform for quantum computation and simulation. The XY model with long-range interactions can be implemented with a single side-band Mølmer–Sørensen scheme, giving interactions that decay as 1 / r α , where α parameterises the interaction range. Lower α leads to longer range interactions, allowing faster long-range gate operations for quantum computing. However, decreasing α causes an increased generation of coherent phonons and appears to dephase the effective XY interaction model. We characterise and show how to correct for this effect completely, allowing lower α interactions to be coherently implemented. Ion trap chains are thus shown to be a viable platform for spatial quantum search in optimal O ( N ) time, for N ions. Finally, we introduce a O ( N ) quantum state transfer protocol, with a qubit encoding that maintains a high fidelity.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Ionization processes in small quasimolecules: He{sub 2}{sup 2+} (He{sup 2+}+ He)

The energy spectra of electrons ejected in He{sup 2+}-He collisions were measured in the ion energy range 6-30 keV. Theoretical analysis of the ionization mechanisms has been performed on the basis of the advanced adiabatic approximation for one-electron processes and perturbation theory for two-electron processes. The ionization channel 2p{sigma}{sup 2}{yields} 1s{sigma}nd{sigma}{yields} 1s{sigma}{epsilon}d{sigma} has been revealed, which makes a considerable contribution to the ionization cross section in the keV ion energy range.

74 ATOMIC AND MOLECULAR PHYSICS↗

Atomistic self-sputtering mechanisms of rf breakdown in high-gradient linacs.

Molecular dynamics (MD) models of sputtering solid and liquid surfaces - including the surfaces charged by interaction with plasma, Coulomb explosion, and Taylor cone formation - were developed. MD simulations of self-sputtering of a crystalline (1 0 0) copper surface by Cu{sup +} ions in a wide range of ion energies (50 eV-50 keV) were performed. In order to accommodate energetic ion impacts on a target, a computational model was developed that utilizes MD to simulate rapid atomic collisions in the central impact zone, and a finite-difference method to absorb the energy and shock wave for the collisional processes occurring at a longer time scales. The sputtering yield increases if the surface temperature rises and the surface melts as a result of heat from plasma. Electrostatic charging of the surface under bombardment with plasma ions is another mechanism that can dramatically increase the sputtering yield because it reduces the surface binding energy and the surface tension. An MD model of Taylor cone formation at a sharp tip placed in a high electric field was developed, and the model was used to simulate Taylor cone formation for the first time. Good agreement was obtained between the calculated Taylor cone angle (104.3{sup o}) and the experimental one (98.6{sup o}). A Coulomb explosion (CE) was proposed as the main surface failure mechanism triggering breakdown, and the dynamics of CE was studied by MD.

43 PARTICLE ACCELERATORS↗

Thomson spectrometer-microchannel plate assembly calibration for MeV-range positive and negative ions, and neutral atoms

We report on the absolute calibration of a microchannel plate (MCP) detector, used in conjunction with a Thomson parabola spectrometer. The calibration delivers the relation between a registered count numbers in the CCD camera (on which the MCP phosphor screen is imaged) and the number of ions incident on MCP. The particle response of the MCP is evaluated for positive, negative, and neutral particles at energies below 1 MeV. As the response of MCP depends on the energy and the species of the ions, the calibration is fundamental for the correct interpretation of the experimental results. The calibration method and arrangement exploits the unique emission symmetry of a specific source of fast ions and atoms driven by a high power laser.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electronic stopping powers for heavy ions in SiC and SiO{sub 2}

Accurate information on electronic stopping power is fundamental for broad advances in materials science, electronic industry, space exploration, and sustainable energy technologies. In the case of slow heavy ions in light targets, current codes and models provide significantly inconsistent predictions, among which the Stopping and Range of Ions in Matter (SRIM) code is the most commonly used one. Experimental evidence, however, has demonstrated considerable errors in the predicted ion and damage profiles based on SRIM stopping powers. In this work, electronic stopping powers for Cl, Br, I, and Au ions are experimentally determined in two important functional materials, SiC and SiO{sub 2}, based on a single ion technique, and new electronic stopping power values are derived over the energy regime from 0 to 15 MeV, where large deviations from the SRIM predictions are observed. As an experimental validation, Rutherford backscattering spectrometry (RBS) and secondary ion mass spectrometry (SIMS) are utilized to measure the depth profiles of implanted Au ions in SiC for energies from 700 keV to 15 MeV. The measured ion distributions by both RBS and SIMS are considerably deeper than the SRIM predictions, but agree well with predictions based on our derived stopping powers.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

MeV Au Ion Irradiation in Silicon and Nanocrystalline Zirconia Film Deposited on Silicon Substrate

Nanocrystalline zirconia (ZrO2) film with thickness of 305 nm deposited on a silicon substrate was irradiated with 2 MeV Au ions to different fluences at different temperatures. The implanted ion profiles were measured by time-of-flight secondary ion mass spectrometry (ToF-SIMS) and simulated using the stopping and range of ions inmatter (SRIM) code, respectively. The experimental results show that a large fraction of the incident Au ions penetrates through the ZrO2 film and are deposited into the Si substrate. At the interface of ZrO2 and Si, a sudden decrease of Au concentration is observed due to the much larger scattering cross section of Au in ZrO2 than in Si. The depth profile of the Au ions is measured in both the ZrO2 films and the Si substrates, and the results show that the Au distribution profiles do not exhibit a dependence on irradiation temperature. The local Au concentration increases proportionally with the irradiation fluence, suggesting that no thermal or irradiation-induced redistribution of the implanted Au ions. However, the Au concentration in the ZrO2 films, as determined by SIMS, is considerably lower than that predicted by the SRIM results, and the penetration depth from the SIMS measurements is much deeper than that from the SRIM predictions. These observations can be explained by an overestimation of the electronic stopping power, used in the SRIM program, for heavy incident ions in light targets. Over-estimation of the heavy-ion electronic stopping power may lead to errors in local dose calculation and underestimation of the projected range of slow heavy ions in targets that contain light elements. A quick estimate based on a reduced target density may be used to compensate the overestimation of the electronic stopping power in the SRIM program to provide better ion profile prediction.

Environmental Molecular Sciences Laboratory↗

Variation in plutonium dioxide sputter yields for 1–5 keV Ar+ ions

An oxide layer with a known thickness and chemistry was grown on delta stabilized Pu and sputtered with 1–5 keV Ar+ ions over a range of incident ion angle between 22° and 72°. From the time required to remove the oxide layer, sputter yields of PuO2 were calculated. The sputter yields appear to increase with higher Ar+ ion beam energy in the range of 1–5 keV at an incident sputter ion angle of 42° and were found to increase with a decreasing angle of incidence up to 62°. The degree of oxide reduction induced during the sputter process was found to vary with the incident sputter ion angle.

Donald, Scott B.↗

Tagged Short-Range Correlations for Medium to Heavy Ions at an Electron Ion Collider

Understanding short-range correlations between pairs of nucleons in the nucleus is an important nuclear physics topic that can address longstanding mysteries in nuclear physics such as the behavior of dense nuclear systems and the modification of parton distributions. As a collider and with a large acceptance detector, the Jefferson Lab version of the Electron Ion Collider has unique capabilities that are complementary to previous short-range correlation studies, most notably the ability to more fully reconstruct the final state. Optimization of the collider’s detector to maximally exploit these capabilities called for important extensions of existing simulation tools. For this one year laboratory directed research and development project, we upgraded the benchmark electron-nucleon event generator for lepto-production simulation code Benchmark eA Generator for LEptoproduction (BeAGLE) to be able to handle tagged medium-to-heavy nucleons. This included updating the code to correctly handle Fermi motion of nucleons in the nucleus as well as the large momentum caused by short-range correlations. In addition, we also investigated the possibility of improved kinematic reconstruction methods for electron nucleon collisions and looked at pair-spectator tagging of short-range correlations with the Jefferson Lab electron ion collider design. The project progressed very much as planned.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Dynamics of Charge States of Relativistic Gold Ion Beams Passing through Cu and Au Foils in the NICA Project

In order to study the properties of dense baryonic matter, an accelerator complex is under development at the Joint Institute for Nuclear Research (Dubna, Russia) within the new NICA project. The NICA project assumes the use of accelerated ion beams ranging from protons to gold ions with relativistic energies up to 4.5 GeV/nucleon. To design experiments, it is necessary to have information on the efficiency of the yield of bare gold nuclei formed at the passage of a gold ion beam with energies of about several hundreds of MeV per nucleon through a foil of a specialized stripping station at the output of the booster of the accelerator. In this work, the optimal conditions (material and thickness of the foil and the energy of the ion) for the formation of fractions of bare gold nuclei with a probability of 80–90% have been determined by calculating electron loss and capture cross sections, as well as the dynamics of charge states of gold ions colliding with copper and gold foils at energies of 400 and 600 MeV/nucleon,.

74 ATOMIC AND MOLECULAR PHYSICS↗

Conformal growth of Mo/Si multilayers on grating substrates using collimated ion beam sputtering

Deposition of multilayers on saw-tooth substrates is a key step in the fabrication of multilayer blazed gratings (MBG) for extreme ultraviolet and soft x-rays. Growth of the multilayers can be perturbed by shadowing effects caused by the highly corrugated surface of the substrates, which results in distortion of the multilayer stack structure and degradation of performance of MBGs. In this study, to minimize the shadowing effects, we used an ion-beamsputtering machine with a highly collimated atomic flux to deposit Mo/Si multilayers on saw-tooth substrates. The sputtering conditions were optimized by finding a balance between smoothening and roughening processes in order to minimize degradation of the groove profile in the course of deposition and at the same time to keep the interfaces of a multilayer stack smooth enough for high efficiency. An optimal value of energy of 200 eV for sputtering Kr + ions was found by deposition of test multilayers on flat substrates at a range of ion energies. Two saw-tooth substrates were deposited at energies of 200 eV and 700 eV for the sputtering ions. It was found that reduction of the ion energy improved the blazing performance of the MBG and resulted in a 40% gain in the diffraction efficiency due to better replication of the groove profile by the multilayer. As a result of the optimization performed, an absolute diffraction efficiency of 28.8% was achieved for the 2nd blaze order of the MBG with a groove density of 7350 lines/mm at a wavelength of 13.5 nm. Lastly, details of the growth behavior of the multilayers on flat and saw-tooth substrates are discussed in terms of the linear continuous model of film growth.

36 MATERIALS SCIENCE↗

Detailed beam and plasma measurements on the vessel for extraction and source plasma analyses (VESPA) Penning H{sup −} ion source

A vessel for extraction and source plasma analyses (VESPA) is operational at the Rutherford Appleton Laboratory (RAL). This project supports and guides the overall ion source R&D effort for the ISIS spallation neutron and muon facility at RAL. The VESPA produces 100 mA of pulsed H{sup −} beam, but perveance scans indicate that the source is production-limited at extraction voltages above 12 kV unless the arc current is increased. A high resolution optical monochromator is used to measure plasma properties using argon as a diagnostic gas. The atomic hydrogen temperature increases linearly with arc current, up to 2.8 eV for 50 A; whereas the electron temperature has a slight linear decrease toward 2.2 eV. The gas density is 10{sup 21} m{sup −3}, whilst the electron density is two orders of magnitude lower. Densities follow square root relationships with arc current, with gas density decreasing whilst electron (and hence ion) density increases. Stopping and range of ions in matter calculations prove that operating a high current arc with an argon admixture is extremely difficult because cathode-coated cesium is heavily sputtered by argon.

43 PARTICLE ACCELERATORS↗

The Biological Effectiveness of Different Radiation Qualities for the Induction of Chromosome Damage in Human Lymphocytes

Chromosome aberrations were measured in human peripheral blood lymphocytes after in vitro exposure to Si-28-ions with energies ranging from 90 to 600 MeV/u, Ti-48-ions with energies ranging from 240 to 1000 MeV/u, or to Fe-56-ions with energies ranging from 200 to 5,000 MeV/u. The LET of the various Si beams in this study ranged from 48 to 158 keV/ m, the LET of the Ti ions ranged from 107 to 240 keV/micron, and the LET of the Fe-ions ranged from 145 to 440 keV/ m. Doses delivered were in the 10- to 200-cGy range. Dose-response curves for chromosome exchanges in cells at first division after exposure, measured using fluorescence in situ hybridization (FISH) with whole-chromosome probes, were fitted with linear or linear-quadratic functions. The relative biological effectiveness (RBE) was estimated from the initial slope of the dose-response curve for chromosome damage with respect to gamma-rays. The estimates of RBEmax values for total chromosome exchanges ranged from 4.4+/-0.4 to 31.5+/-2.6 for Fe ions, 21.4+/-1.7 to 28.3+/-2.4 for Ti ions, and 11.8+/-1.0 to 42.2+/-3.3 for Si ions. The highest RBEmax value for Fe ions was obtained with the 600 MeV/u beam, the highest RBEmax value for Ti ions was obtained 1000 MeV/u beam, and the highest RBEmax value for Si ions was obtained with the 170 MeV/u beam. For Si and Fe ions the RBEmax values increased with LET, reaching a maximum at about 180 keV/micron for Fe and about 100 keV/micron for Si, and decreasing with further increase in LET. Additional studies for low doses Si-28-ions down to 0.02 Gy will be discussed.

Hada, M.↗

Structure and magnetic properties of irradiated Fe/Fe oxide core-shell nanoclusters

A cluster deposition method was used to produce a film of loosely aggregated particles of Fe-Fe3O4 core-shell nanoclusters with an 8 nm iron core size and 2 nm oxide shell thickness. The film of particles on a silicon substrate was irradiated with 5.5 MeV Si2+ ions to a fluence of 1016 cm-2 near room temperature, and computer simulations based on the SRIM (Stopping and Range of Ions in Matter) code show that the implanted Si species stops near the film-substrate interface. The ion irradiation creates a structural change in the film with corresponding chemical and magnetic changes. X-ray diffraction shows that the core size and chemistry stay the same but the shell becomes FeO that grows to a thickness of 17 nm. Helium ion microscopy shows that the previously separate particles have densified into a nearly continuous film. Major loop magnetic hysteresis measurements show a decrease in saturation magnetization that we attribute to the presence of the antiferromagnetic (AFM) FeO shell. First-order reversal curve measurements on the irradiated film performed with a vibrating sample magnetometer show that the AFM shell prevents the particles from interacting magnetically, leading to low coercivity from the iron core and little bias field from the core interactions. These results, and others reported previously on different compositions (Fe3O4 or FeO+Fe3N nanoclusters), show that the ion irradiation behavior of nanocluster films such as these depends strongly on the initial nanostructure and chemistry.

Environmental Molecular Sciences Laboratory↗

Lower Hybrid Frequency Range Waves Generated by Ion Polarization Drift Due to Electromagnetic Ion Cyclotron Waves: Analysis of an Event Observed by the Van Allen Probe B

We analyze a wave event that occurred near noon between 07:03 and 07:08 UT on 23 February 2014 detected by the Van Allen Probes B spacecraft, where waves in the lower hybrid frequency range (LHFR) and electromagnetic ion cyclotron (EMIC) waves are observed to be highly correlated, with Pearson correlation coefficient of approximately 0.86. We assume that the correlation is the result of LHFR wave generation by the ions polarization drift in the electric field of the EMIC waves. To check this assumption the drift velocities of electrons and H+, He+, and O+ ions in the measured EMIC wave electric field were modeled. Then the LHFR wave linear instantaneous growth rates for plasma with these changing drift velocities and different plasma compositions were calculated. The time distribution of these growth rates, their frequency distribution, and the frequency dependence of the ratio of the LHFR wave power spectral density (PSD)parallel and perpendicular to the ambient magnetic eld to the total PSD were found. These characteristics of the growth rates were compared with the corresponding characteristics of the observed LHFR activity. Reasonable agreement between these features and the strong correlation between EMIC and LHFR energy densities support the assumption that the LHFR wave generation can be caused by the ions polarization drift in the electric field of an EMIC wave.

Van Allen Probes↗

Improved Wide Operating Temperature Range of Li-Ion Cells

Future NASA missions aimed at exploring the Moon, Mars, and the outer planets require rechargeable batteries that can operate over a wide temperature range (-60 to +60 C) to satisfy the requirements of various applications including landers, rovers, penetrators, CEV, CLV, etc. This work addresses the need for robust rechargeable batteries that can operate well over a wide temperature range. The Department of Energy (DoE) has identified a number of technical barriers associated with the development of Liion rechargeable batteries for PHEVs. For this reason, DoE has interest in the development of advanced electrolytes that will improve performance over a wide range of temperatures, and lead to long life characteristics (5,000 cycles over a 10-year life span). There is also interest in improving the high-voltage stability of these candidate electrolyte systems to enable the operation of up to 5 V with high specific energy cathode materials. Currently, the state-of-the-art lithium-ion system has been demonstrated to operate over a wide range of temperatures (-40 to +40 C); however, the rate capability at the lower temperatures is very poor. In addition, the low-temperature performance typically deteriorates rapidly upon being exposed to high temperatures. A number of electrolyte formulations were developed that incorporate the use of electrolyte additives to improve the high-temperature resilience, low-temperature power capability, and life characteristics of methyl propionate (MP)-based electrolyte solutions. These electrolyte additives include mono-fluoroethylene carbonate (FEC), lithium oxalate, vinylene carbonate (VC), and lithium bis(oxalate borate) (LiBOB), which have previously been shown to result in improved high-temperature resilience of all carbonate-based electrolytes. These MP-based electrolytes with additives have been shown to have improved performance in experiments with MCMB-LiNiCoAlO2 cells.

Smart, Marshall C.↗

Time dependent behaviors of ion-ion plasmas exposed to various voltage waveforms in the kilohertz to megahertz frequency range

An ion-ion plasma, situated between two parallel electrodes, is studied with the use of a time dependent one-dimensional particle-in-cell Monte-Carlo collisions model. This plasma consists of only positively and negatively singly charged ions with the same order of mass and temperature (the electron density is zero). The right electrode is grounded, and the left electrode is biased with a voltage waveform varying from sinusoidal to square with the frequency in the kHz to MHz range. The sheath evolution and the particle flux towards the electrodes, as a function of both space and time, are investigated for the various waveforms and frequencies. The sheath evolution has a strong influence on the time averaged ion energy distribution function (IEDF). The IEDF is broad with a low energy tail for low frequency sinusoidal biases (25 kHz) while peaked at low energy for higher frequencies (2 MHz). For square waveforms, the IEDF is mono-energetic with some broadening when the rise time is faster than the typical time to establish the steady state sheath formation (<0.3 {mu}s).

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Transport model study of nuclear stopping in heavy-ion collisions over the energy range from 0.09A to 160A GeV

Nuclear stopping in heavy-ion collisions over a beam energy range from SIS and AGS up to SPS is studied in the framework of the modified Ultrarelativistic Quantum Molecular Dynamics transport model, in which mean field potentials of both formed and 'preformed' hadrons (from string fragmentation) and medium-modified nucleon-nucleon elastic cross sections are considered. It is found that nuclear stopping is influenced by both the stiffness of the equation of state and medium modifications of nucleon-nucleon cross sections at SIS energies. At high SPS energies, a two-bump structure is shown in the experimental rapidity distribution of free protons, which can be understood by considering the preformed hadron potentials.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Revealing ionization-induced dynamic recovery in ion-irradiated SrTiO 3

The lack of fundamental understanding on the coupled effects of energy deposition to electrons and atomic nuclei on defect processes and irradiation response poses a significant roadblock for the design and control of material properties. In this work, SrTiO 3 has been irradiated with various ion species over a wide range of ion fluences at room temperature with a goal to deposit different amounts of energy to target electrons and atomic nuclei by varying the ratio of electronic to nuclear energy loss. Here, the results unambiguously show a dramatic difference in behavior of SrTiO 3 irradiated with light ions (Ne, O) compared to heavy ions (Ar). While the damage accumulation and amorphization under Ar ion irradiation are consistent with previous observations and existing models, the damage accumulation under Ne irradiation reveals a quasi-saturation state at a fractional disorder of 0.54 at the damage peak for an ion fluence corresponding to a dose of 0.5 dpa; this is followed by further increases in disorder with increasing ion fluence. In the case of O ion irradiation, the damage accumulation at the damage peak closely follows that for Ne ion irradiation up to a fluence corresponding to a dose of 0.5 dpa, where a quasi-saturation of fractional disorder level occurs at about 0.48; however, in this case, the disorder at the damage peak decreases slightly with further increases in fluence. This behavior is associated with changes in kinetics due to irradiation-enhanced diffusional processes that are dependent on electronic energy loss and the ratio of electronic to nuclear energy dissipation. Lastly, these findings are critical for advancing the fundamental understanding of ion-solid interactions and for a large number of applications in oxide electronics where SrTiO 3 is a foundational material.

36 MATERIALS SCIENCE↗