Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Inertia”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Cost-Benefit Analysis of Grid-Supportive Loads for Fast Frequency Response

Flexibility in inverter-based loads could be used to support the converter-dominated power grid by offering a rapid, autonomous, and adjustable power reserve during system transients to help maintain system stability. Based on technical potential, ancillary service (AS) value, and implementation costs, this study illustrates the cost-benefit analysis of grid-supportive loads (GSLs) for the supply of fast frequency response (FFR). The net benefit for each GSL is demonstrated using a case study and relevant data sources. The findings suggest that implementation costs for enabling GSL features are low compared to the value that grid operators get from the acquisition of responsive reserve services. The authors believe that, given the rising popularity of renewable energy sources, GSLs can be a useful tool for grid stability in low-inertia systems.

cost-benefit analysis↗

Operability of a Power System with Synchronous Condensers and Grid-Following Inverters

Growing shares of inverter-based resources gener-ally correlate with a reduction in inertia as synchronous genera-tors are displaced. Along the path to high shares of inverter-based resources, in particular with only conventional grid-following inverter controls, a proffered solution is the use of synchronous condensers as a source of inertia to maintain the frequency-power balance relationship. An outstanding question is whether only grid-following inverters and synchronous condensers yield a viable power system; i.e., all frequency response is derived from inverters. A validated electromagnetic transient model of the Maui system, with many nonlinear elements such as load-shedding, line tripping, and inverter ride through criteria disabled, is used to investigate the stability of such a system. Two types of perturbations were applied, a 15% generation loss and a fault event, and it was found that the system remains stable.

grid-following inverters↗

Analyzing Gas Turbine-Generator Performance of the Hybrid Power System

We report kinetic energy available from the turbomachinery may boost short-term ramp rates during load shifting between generator and fuel cell that may be exploited to optimize the performance of turbine-fuel cell hybrid systems during load following. The paper starts with modeling a gas turbine, gearbox, and generator sitting on the rigid shafts as a two-mass model primarily for estimating the rotational inertia available from the turbogenerator. The gas turbine and its environment impose constraints of available space allowances, measurements from high-speed rotating parts, lack of accessibility to the shaft of measure, making replacements and/or required installation adjustments of the torque transducer difficult. It is demonstrated that in the absence of torque measurement, the data containing only a slow excursion of the rotor motion in response to a slight load change is sufficient to determine inertia and damping coefficients from the model. Furthermore, the generator’s reactive power capability was investigated because it serves as an asset in integrated hybrid systems to meet dynamic reactive power demands, reducing the burden on the fuel cell’s power electronics control in generating reactive power.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Frequency Support From Electric Vehicles for Advancing Renewable Energy Integration

The integration of renewable energy resources (RERs) in the modern power grid is increasing rapidly because of aggressive decarbonization goals, lower costs, and increased government investment. However, higher penetrations of inverter-based generation can lead to frequency stability issues because of reduced system inertia. This paper develops a framework for quantifying the contribution of electric vehicles (EVs) toward providing frequency support to the grid and thus increasing the penetration limit of renewable energy resources (RERs). EVs are considered to provide both inertial response and primary frequency response support to the grid. A stochastic approach incorporating the uncertainties associated with the behavior of EVs is developed to derive the discharge limit of EV aggregators. A multi-machine system frequency response (MM-SFR) model is developed, which incorporates the dynamic virtual inertia and droop coefficients of EV aggregators derived from the EV control modules. Frequency security constraints are developed from this MM-SFR model, which, along with the converter voltage security and low voltage ride-through constraints, are integrated within a nonlinear optimization framework to determine the RER integration limit. Here, the efficacy of the proposed approach is validated using the RTS-GMLC test system.

25 ENERGY STORAGE↗

Power HIL Validation of a MW-Scale Grid-Forming Inverter's Stabilization of Otherwise Unstable Cases of the Maui Transmission System

This presentation summarizes MW-scale power hardware-in-the-loop experiments using a 2.2 MW grid-forming inverter connected to a real-time electromagnetic transient simulation of the Maui transmission system. The hardware inverter used is a commercially available "off-the-shelf" inverter from a major manufacturer that is capable of operating in grid-forming mode or grid-following mode. The hardware inverter was connected via power hardware-in-the-loop to a real-time model of the year-2023 Maui power system, which consists of a networked transmission system with diverse generation sources. The results of the simulations indicate that with sufficient synchronous machines online, the system is stable without grid-forming inverters, but that as the amount of synchronous machines is reduced, the system becomes unstable. Changing the hardware inverter (scaled up to represent a 30 MW plant) into grid-forming mode mitigates the instability in various low-inertia cases, including a zero-inertia scenario with 100% of generation from PV and wind. This result broadly agrees with pure simulation results.

battery energy storage system↗

Closure of Earth’s Global Seasonal Cycle of Energy Storage

Abstract The global seasonal cycle of energy in Earth’s climate system is quantified using observations and reanalyses. After removing long-term trends, net energy entering and exiting the climate system at the top of the atmosphere (TOA) should agree with the sum of energy entering and exiting the ocean, atmosphere, land, and ice over the course of an average year. Achieving such a balanced budget with observations has been challenging. Disagreements have been attributed previously to sparse observations in the high-latitude oceans. However, limiting the local vertical integration of new global ocean heat content estimates to the depth to which seasonal heat energy is stored, rather than integrating to 2000 m everywhere as done previously, allows closure of the global seasonal energy budget within statistical uncertainties. The seasonal cycle of energy storage is largest in the ocean, peaking in April because ocean area is largest in the Southern Hemisphere and the ocean’s thermal inertia causes a lag with respect to the austral summer solstice. Seasonal cycles in energy storage in the atmosphere and land are smaller, but peak in July and September, respectively, because there is more land in the Northern Hemisphere, and the land has more thermal inertia than the atmosphere. Global seasonal energy storage by ice is small, so the atmosphere and land partially offset ocean energy storage in the global integral, with their sum matching time-integrated net global TOA energy fluxes over the seasonal cycle within uncertainties, and both peaking in April.

54 ENVIRONMENTAL SCIENCES↗

A scalable planning framework of energy storage systems under frequency dynamics constraints

As the penetration of renewables increases in power systems, the declining system inertia can cause frequency stability issues. Battery energy storage systems (BESSs) respond fast and therefore can relieve the low inertia difficulty but need to be appropriately sized considering the associated cost. This paper presents a novel stochastic optimization model for economically planning BESS capacity while considering the spatial–temporal correlation of wind generation and generator outages under frequency stability constraints, which include the rate-of-change of frequency (RoCoF), frequency nadir (FN), and quasi-steady-state (QSS) frequency. A set of new FN constraints that can be easily linearized is developed. To account for renewable uncertainties, a realistic uncertainty modeling approach, Random Field, is adopted to generate wind generation scenarios by considering both spatial and temporal evolutions of wind speed profiles. The ESS sizing is formulated as a mixed-integer linear programming problem and solved by using a scalable decomposition-and-coordination approach, Surrogate Absolute Value Lagrangian Relaxation (SAVLR). To further improve the scalability and reduce computational burdens, a rolling-horizon-based update is developed and incorporated into SAVLR for providing a practical solution to the long-term planning of very large-scale power systems. Finally, a modified IEEE 118-bus system and the Polish system are used to validate the effectiveness and scalability of the model and solution methodology.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Joint scheduling of energy, fast and primary frequency response reserves in integrated transmission–distribution networks

Inverter-based distributed energy resources (DERs) connected to distribution networks (DNs) can provide fast frequency support, but their reserve deliverability depends on feeder constraints and differs from synchronous primary frequency response (PFR). Existing transmission–distribution coordination studies usually treat reserve generically or neglect feeder-level feasibility, while frequency-security scheduling studies rarely represent distribution feeders explicitly. This paper develops a bi-level day-ahead scheduling framework for integrated transmission–distribution networks that jointly clears energy, transmission-side PFR, and distribution-side fast frequency response (FFR) under exogenous hourly inertia and largest-loss inputs from an external unit commitment (UC) schedule. The transmission problem is modeled with DC-optimal power flow (OPF) and closed-form second-order cone (SOC) frequency-security constraints, whereas each DN is represented by a reserve-aware branch-flow AC-OPF so that scheduled fast reserves remain deliverable during activation. The bi-level problem is reformulated through Karush–Kuhn–Tucker (KKT) conditions into a mixed-integer SOC program, and a penalty term is used to tighten the distribution-network relaxation. In the reduced test system, lower exogenous inertia increased the required primary response from 179.64 MW to 191.08 MW, distribution-side fast response reduced total frequency-response procurement by up to 4.9%, and neglecting distribution constraints overstated the combined distribution-side energy and reserve award by up to 18%. In the expanded study, the largest case was solved in 2.02 s with a 0.00% optimality gap. Time-domain simulations kept the frequency nadir above 59.0 Hz in all tested hours. These results demonstrate the value of fast-response modeling and distribution-feasible reserve delivery in coordinated market clearing.

Noh, Seung-Gil↗

Identification of the optimal carbon fiber shape for cost-specific compressive performance

We report carbon fiber composites offer superior mechanical performance compared to nearly all other useful materials for the design of structures. However, for cost-driven industries, such as with the wind energy and vehicle industries, the cost of commercial carbon fiber materials is often prohibitive for their usage compared to alternatives. This paper develops an approach to optimize fiber geometries for use in carbon fiber reinforced polymers to increase the compressive strength per unit cost. Compressive strength is a composite property that depends on the fiber, matrix, and interface, and an exact analytic expression does not exist that can accurately represent these complicated relationships. The approach taken instead is to use a weighted summation between the fiber cross-sectional area moment of inertia and perimeter as a proxy for compressive strength, with different weightings explored within the paper. Analyses are performed to identify optimal fiber geometries that increase the cost-specific compressive strength based on various assumptions and desired fiber volume fraction. Robust optimal shapes are identified which outperform circular fibers due to increases in area moment of inertia and perimeter, as well as decreases in carbon fiber processing costs.

36 MATERIALS SCIENCE↗

Unstable turbulent channel flow response to spanwise-heterogeneous heat fluxes: Prandtl's secondary flow of the third kind

Turbulent secondary flows are defined as Prandtl's secondary flow of the first or second kind, the former produced by stretching and/or tilting of vorticity, the latter produced via spatial heterogeneity of Reynolds stresses. Both mechanisms are instantaneously active within inertia-dominated wall turbulence; Reynolds stress spatial heterogeneity is required for Reynolds-averaged secondary flows. Spanwise-variable surface roughness can induce turbulent stress spatial heterogeneity in the spanwise–wall-normal plane and provide sustenance for streamwise-aligned mean secondary flows. Herein, we demonstrate that turbulent secondary flows can also be sustained by spanwise variability in the surface heat flux in unstably stratified turbulent channels, defined hereafter as Prandtl's secondary flow of the third kind. Support for this mechanism is established with scaling arguments, while large-eddy simulation is used to model inertia-dominated channel turbulence responding to a lower boundary with uniform aerodynamic/hydrodynamic roughness but spanwise-variable surface heat flux. Transport equations for streamwise vorticity and turbulent kinetic energy, k, outline the conditions needed for third-kind production: shear and buoyancy production over the elevated heat flux regions necessitates lateral entrainment of low- k fluid, inducing mean counter-rotating secondary cells aligned such that upwelling and downwelling occur over the high and low heat flux regions, respectively. Buoyancy-driven production of k alters aggregate flow response and thus is a distinctly different mechanism responsible for sustenance of secondary flows.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Low-temperature Leidenfrost-like jumping of sessile droplets on microstructured surfaces

The Leidenfrost effect—the levitation and hovering of liquid droplets on hot solid surfaces—generally requires a sufficiently high substrate temperature to activate liquid vaporization. Here, in this paper, we report the modulation of Leidenfrost-like jumping of sessile water microdroplets on micropillared surfaces at a relatively low temperature. Compared to traditional Leidenfrost effect occurring above 230 °C, the fin-array-like micropillars enable water microdroplets to levitate and jump off the surface within milliseconds at a temperature of 130 °C by triggering the inertia-controlled growth of individual vapour bubbles at the droplet base. We demonstrate that droplet jumping, resulting from momentum interactions between the expanding vapour bubble and the droplet, can be modulated by tailoring of the thermal boundary layer thickness through pillar height. This enables regulation of the bubble expansion between the inertia-controlled mode and the heat-transfer-limited mode. The two bubble-growth modes give rise to distinct droplet jumping behaviours characterized by constant velocity and constant energy regimes, respectively. This heating strategy allows the straightforward purging of wetting liquid droplets on rough or structured surfaces in a controlled manner, with potential applications including the rapid removal of fouling media, even when located in surface cavities.

42 ENGINEERING↗

Open Source High Fidelity Modeling of a Type-5 Wind Turbine Drivetrain

The increasing integration of renewable energy resources in evolving bulk power system (BPS) is impacting the system inertia. Type-5 wind turbine generation has the potential to behave like a traditional synchronous generator and can help mitigate the impact on system inertia. A hydraulic torque converter (TC) and gearbox with torque limiting feature are integral parts of a Type-5 wind turbine unit. A high fidelity model of Type-5 wind turbine drivetrain is not openly and widely available for grid integration and transient stability studies. This hinders appropriate assessment of Type-5 wind power plant’s contribution to bulk grid resilience. This work develops and validates a TC model based on those generally used in automobile’s transmission system. Moreover, the concept of torsional coupling is leveraged to integrate the TC and gearbox system dynamics. The entire integrated model will be open sourced and publicly available for grid integration studies.

17 WIND ENERGY↗

Nuclear rotation at the fission limit in Rf 254

A ground-state rotational band in the fissile nucleus Rf254 was observed for the first time. Levels up to spin 14 and excitation energy of 1.56 MeV were observed. The Rf254 nuclei were produced using the Pb206(Ti50,2n) fusion-evaporation reaction. It is the weakest reaction channel ever studied using in-beam γ-ray spectroscopic methods. The reaction products were separated from the beam in the Argonne gas-filled analyzer (AGFA). The Rf254 nuclei were implanted into a double-sided Si strip detector at the AGFA focal plane and tagged with subsequent ground-state spontaneous fission decays using temporal and spatial correlations. Prompt γ rays in coincidence with the Rf254 recoils were detected in the Gammasphere array of Ge detectors. In order to identify the ground-state rotational band in Rf254, a method for identifying rotational bands in low statistics γ-ray spectra was developed. The deduced Rf254 kinematic moment of inertia is smaller compared to neighboring even-even nuclei. This is most likely associated with a slightly lower quadrupole deformation and stronger pairing correlations in Rf254. The behavior of the moment of inertia as a function of rotational frequency is similar to that of the lighter N=150 isotones Fm250 and No252.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Astrophysical and Theoretical Physics Implications from Multimessenger Neutron Star Observations

Here, the Neutron Star Interior Composition Explorer (NICER) recently measured the mass and equatorial radius of the isolated neutron star PSR J0030+0451. We use these measurements to infer the moment of inertia, the quadrupole moment, and the surface eccentricity of an isolated neutron star for the first time, using relations between these quantities that are insensitive to the unknown equation of state of supranuclear matter. We also use these results to forecast the moment of inertia of neutron star A in the double pulsar binary J0737-3039, a quantity anticipated to be directly measured in the coming decade with radio observations. Combining this information with the measurement of the tidal Love number with LIGO/Virgo observations, we propose and implement the first theory-agnostic and equation-of-state-insensitive test of general relativity. Specializing these constraints to a particular modified theory, we find that consistency with general relativity places the most stringent constraint on gravitational parity violation to date, surpassing all other previously reported bounds by 7 orders of magnitude and opens the path for a future test of general relativity with multimessenger neutron star observations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A Frequency Control Method for Islanded Microgrids Using Energy Storage Systems

Islanded microgrids are vulnerable to frequency fluctuations due to the presence of low-inertia distributed energy resources (DERs). Moreover, implementation of both synchronous-based and inverter-based DERs with a significant difference in inertia leads to a power imbalance between generation and consumption during transients. This results in frequency variations which might have severe consequences such as blackouts. This paper develops a control scheme for battery energy storage systems (BESSs) to enhance the dynamic response of islanded microgrids by mitigating the frequency fluctuations. A piecewise linear-elliptic (PLE) droop characteristic is proposed and employed in BESS to achieve a faster power balance between generation and consumption during transients, resulting in enhanced frequency responses. Different case studies are carried out to validate the viability of the proposed approach in improving the dynamics of islanded microgrids.

Pilehvar, Mohsen S.↗

Enhanced Frequency Support Scheme of Generic Inverter-Based Resource Models for Renewable-Dominated Power Grids

The frequency response of SG-dominated power grids is predictable ahead of an occurrence of a frequency event because the frequency response of SGs is consistent, and it can be inferred from the swing equation [1]. However, increasing the portion of IBRs in an SG-dominated power grid might make the characteristics of the conventional power grids no longer valid because this changing resource mix affects grid dynamics and controls [2]. Thus, maintaining these characteristics greatly benefits the control and operation of the power grids with high penetration of IBRs. To maintain these characteristics in IBR-dominated power grids, IBRs should have frequency response capability similar to that of an SG. The WECC modeling validation subcommittee has developed generic IBR models for large system planning [3]-[5]. These models can represent various vendors' dynamic behavior for WTG, PV, and ESS [5]. The current generic IBR models approved by WECC can provide frequency response only from droop control loops in REPC models [6], [7]. The contribution of the loops is proportional to the frequency deviation from the nominal frequency. Thus, it presents an insufficient contribution to arrest frequency variation compared to the frequency response of SGs because it allows a high ROCOF in the early stage of frequency events. This shortfall will become greater as the PL of IBRs increases in power grids. Controller enhancement for the generic IBR models is required to secure the frequency stability under high PL of IBRs as in the SG-dominated power grids. This paper proposes a control extension for the generic IBR models to enhance the frequency support capabilities and discusses the classification of frequency support for the different types of IBR considering their operating constraints. An inertial control scheme is implemented in the REPC and REEC models of the generic IBR models to achieve these objectives. The inertial control scheme includes the following stages: Control area data acquisition, inertia time constant estimation, IBR-related constraint check, IBR contribution determination, and inertial response provision. In the scheme, a REPC acquires control area data from a system operator and estimates a total inertia time constant for the control area the applicable IBR power plant belongs. Then, the estimated inertial time constant is transferred to each IBR controller—REEC—within the power plant. Each REEC checks the availability of applicable IBR for inertial response participation. If the IBR is available, the REEC amplifies the estimated inertial time constant to utilize it for inertial response provision. In this way, the proposed inertial response scheme extends the functionality of the generic IBR models to provide SG-like frequency response within their constraints. Various scenarios considering different IBR types, IBR penetration levels, and frequency control schemes were simulated and compared in an IEEE 39-bus system using PSCAD simulator to verify the effectiveness of the proposed scheme.

Kim, Jinho↗

Dynamic Load Inrush Current Mitigation in Islanded Microgrids Powered by Grid-Forming Inverters

Grid-forming inverters in a microgrid may trip due to high inrush current caused by a switched connection of an inductive load, e.g., a relatively large induction motor. The control scheme presented in this article includes virtual inertia control method superimposed on the cascaded controller. This article studies the impact of cascaded control scheme used for grid-forming inverter to mitigate the inrush current effects and enhance the inverter’s robustness for the safe connection of inductive and dynamic loads. Experimental tests are performed using the virtual inertia method for generating the reference angle for synchronous frame conversion. The experimental performance and sensitivity of the controller to different controller gain settings for a switched connection of an induction motor are discussed. The cascaded operation significantly mitigates the inrush currents while the inverters can perform a normal operation. The performance of the control method is tested in a laboratory-scale hardware setup of a 208V microgrid fed by 5kVA and 10kVA inverters, and the results are presented.

Gursoy, Mehmetcan↗

Design and Evaluation of a Model-Free Frequency Control Strategy in Islanded Microgrids with Power-Hardware-in-the-Loop Testing

The deterioration of inertial and primary frequency response of islanded microgrids has been a crucial issue for the proper operation of such microgrids. Several approaches, including inertia emulation strategies, have been proposed to improve the primary frequency response. However, the demonstrations of most inertia emulation research works are based on simulation-only testing which hinder their applicability in the field. In this paper, a novel model-free control (MFC) strategy for frequency response support in a diesel-wind microgrid system is presented, and it is tested for evaluation using a power-hardware-in-the-Ioop (PHIL) platform. The PHIL testing is one step closer to field testing since it allows real-time verification and accounts for the nonlinear grid dynamics, noise, and time delays that are usually ignored in simulation-only environments. The proposed MFC strategy is fully distributed, has low computational requirements, and can be easily implemented in resource constrained devices such as smart inverters. A PHIL microgrid platform consisting of two type-3 wind turbine generators and one diesel generator is used to test the proposed MFC strategy.

Ferrari Maglia, Max↗