Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Image quality”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

King Ghidorah Supercluster: Mapping the light and dark matter in a new supercluster at z = 0.55 using the subaru hyper suprime-cam

ABSTRACT This paper reports our discovery of the most massive supercluster, termed the King Ghidorah Supercluster (KGSc), at z = 0.50–0.64 in the Third Public Data Release of the Hyper Suprime-Cam Subaru Strategic Program (HSC-SSP PDR3) over 690 deg2, as well as an initial result for a galaxy and dark matter mapping. The primary structure of the KGSc comprises triple broad weak-lensing (WL) peaks over 70 comoving Mpc. Such extensive WL detection at z > 0.5 can only currently be achieved using the wide-field high-quality images produced by the HSC-SSP. The structure is also contiguous with multiple large-scale structures across a ∼400 comoving Mpc scale. The entire field has a notable overdensity (δ = 14.7 ± 4.5) of red-sequence clusters. Additionally, large-scale underdensities can be found in the foreground along the line of sight. We confirmed the overdensities in stellar mass and dark matter distributions to be tightly coupled and estimated the total mass of the main structure to be 1 × 1016 solar masses, according to the mock data analyses based on large-volume cosmological simulations. Further, upcoming wide-field multi-object spectrographs such as the Subaru Prime Focus Spectrograph may aid in providing additional insights into distant superclusters beyond the 100 Mpc scale.

Shimakawa, Rhythm (ORCID:0000000344422750)↗

GALAXY CRUISE: Spiral and ring classifications for bright galaxies at z = 0.01–0.3

Abstract This paper presents a morphology classification catalog of spiral and ring features of 59854 magnitude-limited galaxies (r < 17.8 mag, and additional 628005 subsamples down to r = 20 mag) at z = 0.01–0.3 based on the Third Public Data Release of the Hyper Suprime-Cam Subaru Strategic Program. We employ two deep-learning classifiers to determine the spiral and ring structures separately based on GALAXY CRUISE Data Release 1, which is dedicated to Hyper Suprime-Cam data. The number of spiral and ring galaxies contain 31864 and 8808 sources, respectively, which constitute 53% and 15% of the sample. A notable result of this study is the construction of a large sample of ring galaxies utilizing high-quality imaging data delivered by the Subaru Hyper Suprime-Cam. However, the accurate identification of ring galaxies remains difficult at a limited seeing resolution. Additionally, we confirm that most spiral galaxies are located on the star-forming main sequence, whereas ring galaxies preferentially reside in the green valley at stellar masses of 1010.5–1011 solar mass. Furthermore, decreasing fractions of spiral and ring galaxies are observed toward the centers of the galaxy clusters. The obtained morphology catalog is publicly available on the GALAXY CRUISE website.

Shimakawa, Rhythm (ORCID:0000000344422750)↗

Quantifying the line-of-sight halo contribution to the dark matter convergence power spectrum from strong gravitational lenses

Galaxy-galaxy strong gravitational lenses have become a popular probe of dark matter (DM) by providing a window into structure formation on the smallest scales. In particular, the convergence power spectrum of subhalos within lensing galaxies has been suggested as a promising observable to study DM. However, the distances involved in strong-lensing systems are vast, and we expect the relevant volume to contain line-of-sight (LOS) halos that are not associated with the main lens. We develop a formalism to calculate the effect of LOS halos as an effective convergence power spectrum. Here, the multilens plane equation couples the angular deflections of consecutive lens planes, but by assuming that the perturbations due to the LOS halos are small, we show that they can be projected onto the main-lens plane as effective subhalos. We test our formalism by simulating lensing systems using the full multiplane lens equation and find excellent agreement. We show how the relative contribution of LOS halos and subhalos depends on the source and lens redshift, as well as the assumed halo and subhalo mass functions. For a fiducial system with fraction of DM halo mass in substructure f sub = 0.4% for subhalo masses [10 5 –10 8 ]M ⊙ , the interloper contribution to the power spectrum is at least several times greater than that of subhalos for source redshifts z s ≳ 0.5. Furthermore, it is likely that for the SLACS and BELLS lenses the interloper contribution dominates: f sub ≳ 2% (4%) is needed for subhalos to dominate in SLACS (BELLS), which is higher than current upper bounds on f sub for our mass range. Since the halo mass function is better understood from first principles, the dominance of interlopers in galaxy-galaxy lenses with high-quality imaging can be seen as a significant advantage when translating this observable into a constraint on DM.

79 ASTRONOMY AND ASTROPHYSICS↗

Development of electron source feedback for enhanced X-ray beam stability at NSLS-II

Future synchrotron light sources are being designed to deliver significantly higher brightness and coherence, enabling faster scanning and more advanced imaging techniques. However, realizing these capabilities requires improved X-ray beam stability, as vibrations directly limit measurement accuracy and image quality. At the NSLS-II Hard X-ray Nanoprobe (HXN), a local mechanical feedback system mitigates low-frequency motion but provides only limited suppression of dominant vibrations at 27 Hz and 120 Hz. To address this limitation, this work explores the use of the electron beam itself as the actuator for feedback by integrating X-ray beam position monitor signals into the fast orbit feedback system through a dedicated electrometer. Experimental results show that this approach effectively suppresses the dominant vibration peaks and enhances stability at the focusing point. Benchmark ptychography measurements further confirm that electron-beam-based feedback reduces background fluctuations and mitigates vibration-induced artifacts under fast-scanning conditions. These results establish the feasibility of using the electron beam as a feedback actuator for next-generation synchrotron applications and provide an experimental assessment of its potential and limitations.

36 MATERIALS SCIENCE↗

Characterization of a Pixelated Cadmium Telluride Detector System Using a Polychromatic X-Ray Source and Gold Nanoparticle-Loaded Phantoms for Benchtop X-Ray Fluorescence Imaging

In this paper, the imaging dose and scan time have been considered as the two major constraints for routine benchtop x-ray fluorescence computed tomography (XFCT) imaging. One way to address this issue is to acquire x-ray fluorescence (XRF) signals in parallel through a 2D array of single-crystal detectors or a pixelated detector along with the cone-beam x-ray source. To identify a detector system suitable for this purpose, a commercially available, fully spectroscopic cadmium telluride (CdTe) pixelated detector, HEXITEC (High-Energy X-ray Imaging Technology), was tested under the experimental conditions optimized for benchtop XFCT imaging of gold nanoparticles (GNPs). Specifically, two different parallel-hole stainless steel collimators were fabricated and coupled with the detector for seamless integration into our existing benchtop cone-beam XFCT system. After the detector deployment, this benchtop XFCT system was used to detect XRF photons from GNP-loaded phantoms. A pixel-merging algorithm was introduced to enhance the sensitivity of XRF photon detection thereby minimizing the scan time. The effect of pixel-level charge sharing correction algorithms was investigated within the context of benchtop XFCT imaging. The detector energy resolution, in terms of the full width at half maximum (FWHM) values at different gold K-shell XRF energies, was also determined. Of the two charge sharing correction algorithms examined, the charge sharing addition gave better sensitivity than the charge sharing discrimination (csd). On the other hand, under the current experimental conditions, the energy resolution of the HEXITEC detector was the best with the csd and estimated to be 1.56 keV FWHM at 66-69 keV photon energy. Overall, despite some degradation of the detector energy resolution (compared with typical single crystal CdTe detectors), the HEXITEC detector enabled parallel data acquisition under the experimental conditions typical of benchtop XFCT imaging and operated well within our benchtop XFCT setup.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ringing Artifact Reduction Method for Ultrasound Reconstruction Using Multi-Agent Consensus Equilibrium

Non-destructive characterization of multi-layered structures that can be accessed from only a single side is important for applications such as well-bore integrity inspection. Existing methods related to Synthetic Aperture Focusing Technique (SAFT) rapidly produce acceptable results but with significant artifacts. Recently, ultrasound model-based iterative reconstruction (UMBIR) approaches have shown significant improvements over SAFT. However, even these methods produce ringing artifacts due to the high fractional-bandwidth of the excitation signal.In this paper, we propose a ringing artifact reduction method for ultrasound image reconstruction that uses a multi-agent consensus equilibrium (RARE-MACE) framework. Our approach integrates a physics-based forward model that accounts for the propagation of a collimated ultrasonic beam in multi-layered media, a spatially varying image prior, and a denoiser designed to suppress the ringing artifacts that are characteristic of reconstructions from high-fractional bandwidth ultrasound sensor data. We test our method on simulated and experimental measurements and show substantial improvements in image quality compared to SAFT and UMBIR.

Alanazi, Abdulrahman M↗

Long-Range Biometric Identification in Real World Scenarios: A Comprehensive Evaluation Framework Based on Missions

The considerable body of data available for evaluating biometric recognition systems in Research and Development (R&D) environments has contributed to the increasingly common problem of target performance mismatch. Biometric algorithms are frequently tested against data that may not reflect the real world applications they target. From a Testing and Evaluation (T&E) standpoint, this domain mismatch causes difficulty assessing when improvements in State-of-the-Art (SOTA) research actually translate to improved applied outcomes. This problem can be addressed with thoughtful preparation of data and experimental methods to reflect specific use-cases and scenarios.To that end, this paper evaluates research solutions for identifying individuals at ranges and altitudes, which could support various application areas such as counterterrorism, protection of critical infrastructure facilities, military force protection, and border security. We address challenges including image quality issues and reliance on face recognition as the sole biometric modality. By fusing face and body features, we propose developing robust biometric systems for effective long-range identification from both the ground and steep pitch angles. Preliminary results show promising progress in whole-body recognition. This paper presents these early findings and discusses potential future directions for advancing long-range biometric identification systems based on mission-driven metrics.

Aykac, Deniz↗

DECT-MULTRA: Dual-Energy CT Image Decomposition With Learned Mixed Material Models and Efficient Clustering

Dual-energy computed tomography (DECT) imaging plays an important role in advanced imaging applications due to its material decomposition capability. Image-domain decomposition operates directly on CT images using linear matrix inversion, but the decomposed material images can be severely degraded by noise and artifacts. This paper proposes a new method dubbed DECT-MULTRA for image-domain DECT material decomposition that combines conventional penalized weighted-least squares (PWLS) estimation with regularization based on a mixed union of learned transforms (MULTRA) model. Our proposed approach pre-learns a union of common-material sparsifying transforms from patches extracted from all the basis materials, and a union of cross-material sparsifying transforms from multi-material patches. The common-material transforms capture the common properties among different material images, while the cross-material transforms capture the cross-dependencies. The proposed PWLS formulation is optimized efficiently by alternating between an image update step and a sparse coding and clustering step, with both of these steps having closed-form solutions. The effectiveness of our method is validated with both XCAT phantom and clinical head data. The results demonstrate that our proposed method provides superior material image quality and decomposition accuracy compared to other competing methods.

47 OTHER INSTRUMENTATION↗

X-ray and Neutron Radiography for Quantitative Material Reconstructions

Radiography is a powerful tool to determine the interior structure of objects. X-ray radiography is widely used and provides high-resolution images, though X-rays have limited transmission through materials of high atomic number (Z) and density. In contrast, neutrons can penetrate many materials that are heavily attenuating to X-rays, such as metals, providing contrast in the inner layers of highly attenuating items. Past work has shown the value in using both X-ray and neutron radiography for estimating material thicknesses, though that work was limited to simulated data. Here, we demonstrate quantitative material reconstructions using experimental X-ray and neutron radiography data from lab-based systems, accurately modeling radiography system responses to within a few percent to enable quantitative measures of material thickness. We demonstrate the utility of neutron radiography and X-ray radiography for these quantitative reconstructions and introduce methods for using their complementarity to improve image quality and optimize experimental design.

Gilbert, Andrew J.↗

Deep Learning Super-Resolution X-Ray Computed Tomography Algorithms for Additive Manufacturing

Industrial X-ray computed tomography (XCT) is a nondestructive method for inspection and characterization of additively manufactured (AM) materials and parts. In practice, the resolution of XCT can be limited by factors such as detector binning, restricted field of view for large-scale objects, system blur, motion during scanning, and acquisition settings. These limitations can reduce the detectability of critical flaws such as pores, cracks, and lack of fusion. Super-resolution (SR) techniques offer a promising solution for improving the effective resolution and image quality of XCT reconstructions without the need for expensive hardware upgrades or laborious, time-consuming scans. In particular, deep learning-based SR methods have garnered attention in recent years as powerful tools for reconstructing high-resolution volumes from low-resolution inputs. In this work, a novel deep learning-based SR method is proposed for XCT scans of AM parts, and compared against several existing state-of-the-art (SOTA) methods. The proposed method, Simurgh-SR, is built on the pre-existing Simurgh framework and consists of a 2.5D U-Net trained to map low-quality inputs containing noise and artifacts to high-quality reconstructions characterized by higher flaw contrast, better noise texture, and reduced artifacts. The experimental results demonstrate superior performance of Simurgh-SR in performing 4× SR on real industrial XCT scans of thick 316L components, enhancing the structural similarity score and peak signal-to-noise ratio (>7dB) compared to the LR counterpart while improving the F1-score for flaw detection by more than 2.3× when compared to alternative SOTA SR methods. This improvement enables more accurate and significantly faster characterization of metal AM components. Additionally, Simurgh-SR was trained for both 2X and 4X SR and performs effectively at both levels, enabling the use of a single model for various SR factors.

Rahman, Obaid [ORNL] (ORCID:0000000277810840)↗

Picometer sensitivity metrology for EUV absorber phase

With growing interest in EUV attenuated phase-shift masks due to their superior image quality for applications such as dense contact and pillar arrays, it is becoming critical to model, measure, and monitor the intensity and relative phase of multilayer and absorber reflections. We present a solution based on physical modeling of reflectometry data, which can achieve single picometer phase precision and sensitivity to changes in average film thickness below one atomic monolayer. We measure absorber and multilayer reflectivity to determine thin-film parameters with a multidimensional optimization and then acquire a new measurement of either multilayer or absorber to determine perturbations in surface contamination thickness. While it is difficult to assess the accuracy of the first step, the simplicity of the second step allows us to characterize our sensitivity to changes in contamination thickness. Thus, we apply this analysis using an initial set of measurements and repeated measurements after a period of storage. For the multilayer, the total contamination growth was 1068 pm, which occurred almost exclusively during storage (1085 pm) and decreased very slightly during repeated measurements (-17 pm). For the absorber, the behavior was quite different, with a total growth of 126 pm, which occurred much less during storage (28 pm) and primarily during repeated measurements (98 pm). Ultimately, the change in relative phase (absorber minus multilayer) was -0.86 deg for the multilayer and -1.12 deg for the absorber. We estimate the precision of the surface contamination measurement to be 3σ < 6 pm for measuring thickness and 3σ < 0.2 deg for measuring phase.

36 MATERIALS SCIENCE↗

High-precision monitoring of outgassing species in model extreme ultraviolet photoresists with a cavity ring-down spectrometer

Background Extreme ultraviolet (EUV) photoresists play a pivotal role in advancing nanopatterning technologies by balancing image quality and sensitivity. The outgassing behavior of photoresist thin films under EUV and deep ultraviolet (DUV) exposure reveals chemical details relevant to their performance. Aim Here, we focus on utilizing an analytical technique not previously used in photolithography, the tabletop cavity ring-down spectrometer, to investigate outgassing dynamics in EUV photoresists, enabling precise chemical identification and deeper insights into resist processing. Approach The spectrometer’s enhanced laser path length (∼ 20 km) and broadband absorption capabilities in the C–H overtone region allow for sensitive and temporally resolved detection of mixtures of outgassed species. Using a model resist comprising a polymer matrix with a photoacid generator and quencher, we analyzed the influence of time delays between exposure and post-exposure bake (PEB) as well as storage under varying environmental conditions. Results Suppression of isobutylene outgassing and thickness loss was observed with extended delays between exposure and PEB, potentially linked to water absorption and acid deactivation. The technique proved highly effective in distinguishing subtle chemical differences between processing stages. Conclusions Delay times and their environmental conditions, particularly humidity, reduce outgassing and thickness loss of photoresists during PEB, suggesting decreased acid-driven deprotection. This can potentially impact sensitivity, defectivity, and roughness of resist patterns, necessitating precise monitoring and control.

Extreme ultraviolet photoresists↗

High precision monitoring of outgassing species in model EUV photoresists with a cavity ring-down spectrometer

Extreme ultraviolet (EUV) photoresists play a pivotal role in advancing nanopatterning technologies by balancing image quality and sensitivity. The outgassing behavior of photoresist thin films under EUV and deep ultraviolet (DUV) exposure reveals chemical details relevant to their performance. This study focuses on utilizing an analytical technique not previously used in photolithography, the tabletop cavity ring-down spectrometer, to investigate outgassing dynamics in EUV photoresists, enabling precise chemical identification and deeper insights into resist processing. The spectrometer’s enhanced laser path length (~20 km) and broadband absorption capabilities in the CH overtone region allow for sensitive and temporally resolved detection of outgassed species. Using a model resist comprising a polymer matrix with a photoacid generator and quencher, we analyzed the influence of time delays between exposure and Post-Exposure Bake (PEB) as well as storage under varying environmental conditions. Suppression of isobutylene outgassing and thickness loss was observed with extended delays between exposure and PEB, potentially linked to water absorption and acid deactivation. The technique proved highly effective in distinguishing subtle chemical differences between processing stages. Delay times and their environmental conditions, particularly humidity, reduce outgassing and thickness loss of photoresists during PEB, suggesting decreased acid-driven deprotection. This can potentially impact sensitivity, defectivity, and roughness of resist patterns, necessitating precise monitoring and control.

Lüttgenau, Bernhard↗

LoTToR: An Algorithm for Missing-Wedge Correction of the Low-Tilt Tomographic 3D Reconstruction of a Single-Molecule Structure (LoTToR) v1.0

The low-tilt tomographic reconstruction (LoTToR) method is a post-processing method to correct the missing-wedge artifact, which contains a model-free iteration process under a set of constraints in real and reciprocal spaces. A proof of concept is conducted by using the LoTToR on a phantom, i.e., a simulated 3D reconstruction from a low-tilt series of images, including that within a tilt range of ±15°. The method is validated by using both negative-staining (NS) and cryo-electron tomography (cryo-ET) experimental data. A significantly reduced missing-wedge artifact verifies the capability of LoTToR, suggesting a new tool to support the future study of macromolecular dynamics, fluctuation and chemical activity from the viewpoint of single-molecule 3D structure determination. Moreover, the software can be used for hospital computer tomography (CT) to reduce the radiation damage to patients without reducing the CT image quality.

Ren, Gang↗

An adaptable technique for comparative image assessment: Application to crosswell electromagnetic survey design for fluid monitoring

Reservoir integrity stewardship accompanying carbon capture and sequestration considers fluid extraction and reinjection as a risk-mitigating method against overpressuring that could lead to caprock damage and ensuing [Formula: see text] leakage. Crosswell electromagnetics offers a technically viable monitoring method with the spatial volume coverage necessary for reservoir-encompassing pressure management. However, a certain logistic dilemma for deep gas sequestration into saline and thus electrically conductive aquifers is that crosswell magnetic-field measurements underperform in the imaging of more resistive plume bodies, further exacerbated when vertical arrays intersect, as opposed to surround, plumes. Furthermore, comparative synthetic-data plume imaging of such scenarios rates the information content of magnetic-field versus electric-field 3D crosswell layouts for reservoir and infrastructure conditions of a representative pilot site in a coastal area in Florida. The image quality of the resulting plume replications can be ranked numerically through a newly proposed semblance qualifier, appraising the model goodness of fit to a given reference. In contrast to common least-squares measures for goodness of fit, the semblance formulation uses classifying logistic function types, thus enabling a better distinction of predefined anomaly features.

58 GEOSCIENCES↗

Fresnel zone plate development for x-ray radiography of hydrodynamic instabilities at the National Ignition Facility

The study of Rayleigh–Taylor (RT) and Richtmyer–Meshkov (RM) instabilities in a planar geometry at high energy densities at the National Ignition Facility (NIF) requires high spatial resolution imaging. We demonstrate the potential of Fresnel zone plates (FZPs) to achieve resolution that would unlock such studies. FZPs are circular aperiodic gratings that use diffraction to focus x rays and produce an image with high spatial resolution. Taking into account the NIF’s challenging environment, we have designed a specific array of five FZPs for a zinc backlighter to take a radiograph of a target with 9 keV x rays. We measured a mean resolution for the FZP of 1.9µm±0.5µm and a ±1mm depth of focus at an x-ray calibration facility as well as a 2.3µm±0.4µm resolution on a resolution wire mesh shot on the NIF. We also performed an in-depth analysis of the image quality to assess the capability to resolve the small features present in RT and RM instabilities.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Adaptive optical third-harmonic generation microscopy for in vivo imaging of tissues

Third-harmonic generation microscopy is a powerful label-free nonlinear imaging technique, providing essential information about structural characteristics of cells and tissues without requiring external labelling agents. In this work, we integrated a recently developed compact adaptive optics module into a third-harmonic generation microscope, to measure and correct for optical aberrations in complex tissues. Taking advantage of the high sensitivity of the third-harmonic generation process to material interfaces and thin membranes, along with the 1,300-nm excitation wavelength used here, our adaptive optical third-harmonic generation microscope enabled high-resolution in vivo imaging within highly scattering biological model systems. Examples include imaging of myelinated axons and vascular structures within the mouse spinal cord and deep cortical layers of the mouse brain, along with imaging of key anatomical features in the roots of the model plant Brachypodium distachyon. In all instances, aberration correction led to enhancements in image quality.

60 APPLIED LIFE SCIENCES↗

Adorym: a multi-platform generic X-ray image reconstruction framework based on automatic differentiation

We describe and demonstrate an optimization-based X-ray image reconstruction framework called Adorym. Our framework provides a generic forward model, allowing one code framework to be used for a wide range of imaging methods ranging from near-field holography to fly-scan ptychographic tomography. By using automatic differentiation for optimization, Adorym has the flexibility to refine experimental parameters including probe positions, multiple hologram alignment, and object tilts. It is written with strong support for parallel processing, allowing large datasets to be processed on high-performance computing systems. We demonstrate its use on several experimental datasets to show improved image quality through parameter refinement.

36 MATERIALS SCIENCE↗