Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Image processing.”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

SU-E-J-16: Automatic Image Contrast Enhancement Based On Automatic Parameter Optimization for Radiation Therapy Setup Verification

Purpose: In RT patient setup 2D images, tissues often cannot be seen well due to the lack of image contrast. Contrast enhancement features provided by image reviewing software, e.g. Mosaiq and ARIA, require manual selection of the image processing filters and parameters thus inefficient and cannot be automated. In this work, we developed a novel method to automatically enhance the 2D RT image contrast to allow automatic verification of patient daily setups as a prerequisite step of automatic patient safety assurance. Methods: The new method is based on contrast limited adaptive histogram equalization (CLAHE) and high-pass filtering algorithms. The most important innovation is to automatically select the optimal parameters by optimizing the image contrast. The image processing procedure includes the following steps: 1) background and noise removal, 2) hi-pass filtering by subtracting the Gaussian smoothed Result, and 3) histogram equalization using CLAHE algorithm. Three parameters were determined through an iterative optimization which was based on the interior-point constrained optimization algorithm: the Gaussian smoothing weighting factor, the CLAHE algorithm block size and clip limiting parameters. The goal of the optimization is to maximize the entropy of the processed Result. Results: A total 42 RT images were processed. The results were visually evaluated by RT physicians and physicists. About 48% of the images processed by the new method were ranked as excellent. In comparison, only 29% and 18% of the images processed by the basic CLAHE algorithm and by the basic window level adjustment process, were ranked as excellent. Conclusion: This new image contrast enhancement method is robust and automatic, and is able to significantly outperform the basic CLAHE algorithm and the manual window-level adjustment process that are currently used in clinical 2D image review software tools.

60 APPLIED LIFE SCIENCES↗

Reconstruction of elongated bubbles fusing the information from multiple optical probes through a Bayesian inference technique

In this communication, a novel optical technique has been proposed for the reconstruction of the shape of a Taylor bubble using measurements from multiple arrays of optical sensors. The deviation of an optical beam passing through the bubble depends on the contour of bubble surface. A theoretical model of the deviation of a beam during the traverse of a Taylor bubble through it has been developed. Using this model and the time history of the deviation captured by the sensor array, the bubble shape has been reconstructed. The reconstruction has been performed using an inverse algorithm based on Bayesian inference technique and Markov chain Monte Carlo sampling algorithm. The reconstructed nose shape has been compared with the true shape, extracted through image processing of high speed images. Finally, an error analysis has been performed to pinpoint the sources of the errors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Molecular-MNIST Dataset for Machine Learning Study on Diffraction Imaging and Microscopy

An image dataset of 10 different size molecules, where each molecule has 2,000 structural variants, is generated from the 2D cross-sectional projection of Molecular Dynamics trajectories. The purpose of this dataset is to provide a benchmark dataset for the increasing need of machine learning, deep learning and image processing on the study of scattering, imaging and microscopy.

BASIC BIOLOGICAL SCIENCES,OTHER INSTRUMENTATION↗

Simultaneous high speed digital cinematographic and X-ray radiographic imaging of a intense multi-fluid interaction with rapid phase changes

As typical for the study of the vapor explosions, the qualitative and quantitative understanding of the phenomena requires visualization of both material and interface dynamics. A new approach to multi-fluid multiphase visualization is presented with the focus on the development of a synchronized high-speed visualization by digital cinematography and X-ray radiography. The developed system, named SHARP (simultaneous high-speed acquisition of X-ray radiography and photography), and its image processing methodology, directed to an image synchronization procedure and a separate quantification of vapor and molten material dynamics, is presented in this paper. Furthermore, we exploit an intrinsic property of the X-ray radiation, namely the differences in linear mass attenuation coefficients over the beam path through a multi-component system, to characterize the evolution of molten material distribution. Analysis of the data obtained by the SHARP system and image processing procedure developed granted new insights into the physics of the vapor explosion phenomena, as well as, quantitative information of the associated dynamic micro-interactions. (author)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Spatial recurrence analysis: A sensitive and fast detection tool in digital mammography

Efficient diagnostics of breast cancer requires fast digital mammographic image processing. Many breast lesions, both benign and malignant, are barely visible to the untrained eye and requires accurate and reliable methods of image processing. We propose a new method of digital mammographic image analysis that meets both needs. It uses the concept of spatial recurrence as the basis of a spatial recurrence quantification analysis, which is the spatial extension of the well-known time recurrence analysis. The recurrence-based quantifiers are able to evidence breast lesions in a way as good as the best standard image processing methods available, but with a better control over the spurious fragments in the image.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

High-Energy X-ray Tomographic Analysis of Precursor Metal Powders (Ti-6Al-4V) Used for Additive Manufacturing

We utilized high-energy x-ray tomography to characterize Ti-6Al-4V metal powders (both as-received and recycled) used in powder-bed additive manufacturing process. The image processing workflow was developed to process and analyze large amount of data objectively by computer program. The distribution of size and shape of the metal particles as well as defect (mainly porosity) inside the particles was analyzed with the statistical representation and resolution in micrometer. The result revealed that circular-shaped porosity with various sizes could be embedded in the powder particles. These porosities could potentially be transferred to the 3D printed part and critically affect the mechanical performance of the component. The present study shows the effectiveness of characterizing metal powders using x-ray imaging techniques where sufficient number of particles can be sampled within tens of minutes with a minimum sample preparation and high accuracy. Clear structural differences in the as-received and recycled powders were delineated that helps in determining the feasibility of using the recycled powders.

36 MATERIALS SCIENCE↗

Poisson’s ratio of eTPU molded bead foams in compression via in situ synchrotron X-ray microtomography

In situ synchrotron X-ray microtomography was used to characterize the bulk deformation behavior by computing the Poisson's ratio of expanded thermoplastic polyurethane (eTPU) molded bead foams used in footwear midsole during compression. Quantitative data on morphological characteristics were obtained using an iterative image processing workflow. Image correlation on the 4D datasets using DVC was performed to calculate the volumetric and axial strain to estimate the Poisson ratio. Strain maps from DVC showed the influence of variability in ligament thickness distribution on the global mechanical behavior exhibited which dominated the response seen in these bead foams. Lastly, our results showed a strong correlation between Poisson ratio and distribution of ligament thickness in foams.

36 MATERIALS SCIENCE↗

A Refined Global Segmentation of X-Ray CT Images for Multi-phase Geomaterials

X-ray computed tomography images of three-phase silica sand and glass bead specimens are analyzed and used to evaluate the segmentation performances of Otsu-, and recursion-based multilevel algorithms. A global image segmentation technique that combines iterative and recursive algorithms, namely a refined statistics-based global segmentation is proposed for segmenting multi-phase granular geomaterials. The performance of the proposed algorithm is tested by segmenting partially saturated silica sand and glass bead specimens. For the tested silica sand specimen, the refined statistics method estimated void ratio and degree of saturation were 0.67 and 39.35%. The estimates for the glass bead specimen yielded 0.64 and 43.49%, respectively. The true void ratio (0.66) and degree of saturation (37.71%) were determined with a user-controlled Image processing software package—Image-Pro. It was found that the proposed method estimated the void ratio and the degree of saturation with 1.52 and 4.35 percent errors for the silica sand and with 15.63 and 0.34 percent errors for the glass bead, respectively. The computational time of the proposed method was found to be shorter than other methods considered. Overall, it is concluded that the proposed technique performed better in segmenting three-phase granular geomaterials.

42 ENGINEERING↗

Distortion of Digital Image Correlation (DIC) Displacements and Strains from Heat Waves

“Heat waves” is a colloquial term used to describe convective currents in air formed when different objects in an area are at different temperatures. In the context of Digital Image Correlation (DIC) and other optical-based image processing techniques, imaging an object of interest through heat waves can significantly distort the apparent location and shape of the object. We present that there are many potential heat sources in DIC experiments, including but not limited to lights, cameras, hot ovens, and sunlight, yet error caused by heat waves is often overlooked. This paper first briefly presents three practical situations in which heat waves contributed significant error to DIC measurements to motivate the investigation of heat waves in more detail. Then the theoretical background of how light is refracted through heat waves is presented, and the effects of heat waves on displacements and strains computed from DIC are characterized in detail. Finally, different filtering methods are investigated to reduce the displacement and strain errors caused by imaging through heat waves. The overarching conclusions from this work are that errors caused by heat waves are significantly higher than typical noise floors for DIC measurements, and that the errors are difficult to filter because the temporal and spatial frequencies of the errors are in the same range as those of typical signals of interest. In conclusion, eliminating or mitigating the effects of heat sources in a DIC experiment is the best solution to minimizing errors caused by heat waves.

42 ENGINEERING↗

Locally Resolved Electron Emission Area and Unified View of Field Emission from Ultrananocrystalline Diamond Films

One of the common problems in case of field emission from polycrystalline diamond films, which typically have uniform surface morphology, is uncertainty in determining exact location of electron emission sites across the surface. Although several studies have suggested that grain boundaries are the main electron emission source, it is not particularly clear what makes some sites emit more than the others. It is also practically unclear how one could quantify the actual electron emission area and therefore field emission current per unit area. In this paper we study the effect of actual, locally resolved, field emission (FE) area on electron emission characteristics of uniform planar highly conductive nitrogen-incorporated ultrananocrystalline diamond ((N)UNCD) field emitters. It was routinely found that field emission from as-grown planar (N)UNCD films is always confined to a counted number of discrete emitting centers across the surface which varied in size and electron emissivity. It was established that the actual FE area critically depends on the applied electric field, as well as that the actual FE area and the overall electron emissivity improve with sp2 fraction present in the film irrespectively of the original substrate roughness and morphology. To quantify the actual FE area and its dependence on the applied electric field, imaging experiments were carried out in a vacuum system in a parallel-plate configuration with a specialty anode phosphor screen. Electron emission micrographs were taken concurrently with I-V characteristics measurements. In addition, a novel automated image processing algorithm was developed to process extensive imaging datasets and calculate emission area per image. By doing so, it was determined that the emitting area was always significantly smaller than the FE cathode surface area. Namely, the actual FE area would change from 5×10-3 % to 1.5 % of the total cathode area with the applied electric field increased. Finally and most importantly, it was shown that when I-E curves as measured in the experiment were normalized by the field-dependent emission area, the resulting j-E curves demonstrated a strong kink and significant deviation from Fowler-Nordheim (FN) law, and eventually saturated at a current density of ~100 mA/cm2 . This value was nearly identical for all (N)UNCD films measured in this study, regardless of the substrate.

36 MATERIALS SCIENCE↗

LaueMatching: an approach for rapid and robust indexing of Laue diffraction patterns

Traditional Laue diffraction pattern indexing often struggles with noisy data, weak signals, peak overlap and missing reflections, particularly from complex or deformed microstructures. Here, we introduce LaueMatching, a high-throughput indexing algorithm designed to overcome these limitations. LaueMatching utilizes a fundamentally different approach based on direct pattern correlation: experimentally pre-processed images are compared against a comprehensive pre-computed library of simulated diffraction patterns corresponding to a dense grid of possible orientations. This approach bypasses the need for explicit peak identification and fitting, steps that are often a failure point for traditional methods. The algorithm rapidly and robustly indexes multiple crystallographic orientations and crystal systems simultaneously, even from challenging patterns. LaueMatching's effectiveness and accuracy have been rigorously tested and validated on diverse experimental (Ni, Al, EuAl 2 O 4 ) and simulated diffraction patterns, demonstrating high-fidelity orientation refinement. Code to implement this approach on both CPU and GPU resources can be downloaded from https://github.com/AdvancedPhotonSource/LaueMatching.

36 MATERIALS SCIENCE↗

Quapprox: A Framework for Benchmarking the Approximability of Variational Quantum Circuit

Most of the existing quantum neural network models, such as variational quantum circuits (VQCs), are limited in their ability to explore the non-linear relationships in input data. This gradually becomes the main obstacle for it to tackle realistic applications, such as natural language processing, medical image processing, and wireless communications. Recently, there have emerged research efforts that enable VQCs to perform non-linear operations. However, it is still unclear on the approximability of a given VQC (i.e., the order of non-linearity that can be handled by a specified design). In response to this issue, we developed an automated tool designed to benchmark the approximation of a given VQC. The proposed tool will generate a set of synthetic datasets with different orders of non-linearity and train the given VQC on these datasets to estimate their approximability. Our experiments benchmark VQCs with different designs, where we know their theoretic approximability. We then show that the proposed tool can precisely estimate the approximability, which is consistent with the theoretic value, indicating that the proposed tool can be used for benchmarking the approximability of a given quantum circuit for learning tasks.

artificial intelligence↗

Effect of image quality on calcification detection in digital mammography

Purpose: This study aims to investigate if microcalcification detection varies significantly when mammographic images are acquired using different image qualities, including: different detectors, dose levels, and different image processing algorithms. An additional aim was to determine how the standard European method of measuring image quality using threshold gold thickness measured with a CDMAM phantom and the associated limits in current EU guidelines relate to calcification detection. Methods: One hundred and sixty two normal breast images were acquired on an amorphous selenium direct digital (DR) system. Microcalcification clusters extracted from magnified images of slices of mastectomies were electronically inserted into half of the images. The calcification clusters had a subtle appearance. All images were adjusted using a validated mathematical method to simulate the appearance of images from a computed radiography (CR) imaging system at the same dose, from both systems at half this dose, and from the DR system at quarter this dose. The original 162 images were processed with both Hologic and Agfa (Musica-2) image processing. All other image qualities were processed with Agfa (Musica-2) image processing only. Seven experienced observers marked and rated any identified suspicious regions. Free response operating characteristic (FROC) and ROC analyses were performed on the data. The lesion sensitivity at a nonlesion localization fraction (NLF) of 0.1 was also calculated. Images of the CDMAM mammographic test phantom were acquired using the automatic setting on the DR system. These images were modified to the additional image qualities used in the observer study. The images were analyzed using automated software. In order to assess the relationship between threshold gold thickness and calcification detection a power law was fitted to the data. Results: There was a significant reduction in calcification detection using CR compared with DR: the alternative FROC (AFROC) area decreased from 0.84 to 0.63 and the ROC area decreased from 0.91 to 0.79 (p < 0.0001). This corresponded to a 30% drop in lesion sensitivity at a NLF equal to 0.1. Detection was also sensitive to the dose used. There was no significant difference in detection between the two image processing algorithms used (p > 0.05). It was additionally found that lower threshold gold thickness from CDMAM analysis implied better cluster detection. The measured threshold gold thickness passed the acceptable limit set in the EU standards for all image qualities except half dose CR. However, calcification detection varied significantly between image qualities. This suggests that the current EU guidelines may need revising. Conclusions: Microcalcification detection was found to be sensitive to detector and dose used. Standard measurements of image quality were a good predictor of microcalcification cluster detection.

61 RADIATION PROTECTION AND DOSIMETRY↗

Distributed Halide

Many image processing tasks are naturally expressed as a pipeline of small computational kernels known as stencils. Halide is a popular domain-specific language and compiler designed to implement image processing algorithms. Halide uses simple language constructs to express what to compute and a separate scheduling co-language for expressing when and where to perform the computation. This approach has demonstrated performance comparable to or better than hand-optimized code. Until now, however, Halide has been restricted to parallel shared memory execution, limiting its performance for memory-bandwidth-bound pipelines or large-scale image processing tasks. We present an extension to Halide to support distributed-memory parallel execution of complex stencil pipelines. These extensions compose with the existing scheduling constructs in Halide, allowing expression of complex computation and communication strategies. Existing Halide applications can be distributed with minimal changes, allowing programmers to explore the tradeoff between recomputation and communication with little effort. Approximately 10 new of lines code are needed even for a 200 line, 99 stage application. On nine image processing benchmarks, our extensions give up to a 1.4× speedup on a single node over regular multithreaded execution with the same number of cores, by mitigating the effects of non-uniform memory access. The distributed benchmarks achieve up to 18× speedup on a 16 node testing machine and up to 57× speedup on 64 nodes of the NERSC Cori supercomputer.

97 MATHEMATICS AND COMPUTING↗

Detecting the Extent of Cellular Decomposition after Sub-Eutectoid Annealing in Rolled UMo Foils

This report presents an automated image processing approach to quantifying microstructure image data, specifically the extent of eutectoid (cellular) decomposition in rolled U-10Mo foils. An image processing approach is used here to be able to quantitatively describe microstructure image data in order to relate microstructure to processing parameters (time, temperature, deformation).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

MO-B-207B-00: Harmonization & Robustness in Radiomics

Feature extraction for radiomics studies typically comprises the following stages: Imaging, segmentation, image processing, and feature extraction. Each of these stages has associated uncertainties that can affect the quality of a radiomics model created using the resulting image features. For example, the imaging device manufacturer and model have been shown to impact the values of image features, as have pixel size and imaging protocol parameters. Image processing, such as low-pass filtering to reduce noise, also changes calculated image features and should be designed to optimize the information content of the resulting features. The details of certain feature algorithms, such as co-occurrence matrix bin sizes, are also important, and should be optimized for specific radiomics tasks. The volume of the region of interest should be considered as image features can be related to volume and can give unanticipated results when the volumes are too small. In this session we will describe approaches to quantify the variabilities in radiomics studies, including the most recent results quantifying these variabilities for CT, MRI and PET imaging. We will discuss methods to optimize image processing and feature extraction in order to maximize the information content of the image features. Finally, we will describe work to harmonize imaging protocols and feature calculations to help minimize uncertainties in radiomics studies. Learning Objectives: At the end of this session, participants will be able to: Identify the sources of uncertainty in radiomics studies (CT, PET, and MRI imaging) Describe methods for quantifying the magnitude of uncertainties Describe approaches for mitigating the effects of the uncertainties on radiomics models Funding from NIH, CPRIT, Varian, Elekta; L. Court, NCI, CPRIT, Varian, Elekta.

60 APPLIED LIFE SCIENCES↗

MO-B-207B-01: Harmonization & Robustness in Radiomics

Feature extraction for radiomics studies typically comprises the following stages: Imaging, segmentation, image processing, and feature extraction. Each of these stages has associated uncertainties that can affect the quality of a radiomics model created using the resulting image features. For example, the imaging device manufacturer and model have been shown to impact the values of image features, as have pixel size and imaging protocol parameters. Image processing, such as low-pass filtering to reduce noise, also changes calculated image features and should be designed to optimize the information content of the resulting features. The details of certain feature algorithms, such as co-occurrence matrix bin sizes, are also important, and should be optimized for specific radiomics tasks. The volume of the region of interest should be considered as image features can be related to volume and can give unanticipated results when the volumes are too small. In this session we will describe approaches to quantify the variabilities in radiomics studies, including the most recent results quantifying these variabilities for CT, MRI and PET imaging. We will discuss methods to optimize image processing and feature extraction in order to maximize the information content of the image features. Finally, we will describe work to harmonize imaging protocols and feature calculations to help minimize uncertainties in radiomics studies. Learning Objectives: At the end of this session, participants will be able to: Identify the sources of uncertainty in radiomics studies (CT, PET, and MRI imaging) Describe methods for quantifying the magnitude of uncertainties Describe approaches for mitigating the effects of the uncertainties on radiomics models Funding from NIH, CPRIT, Varian, Elekta; L. Court, NCI, CPRIT, Varian, Elekta.

60 APPLIED LIFE SCIENCES↗