Digital Mammography with a Mosaic of CCD Arrays

A digital mammography device uses a mosaic of electronic digital imaging arrays to scan an x-ray image is discussed. The mosaic of arrays is repositioned several times to expose different portions of the image, until the entire image is scanned. The data generated by the arrays during each exposure is stored in a computer. After the final exposure, the computer combines data of the several partial images to produce a composite of the original x-ray image. An aperture plate is used to reduce scatter and the overall exposure of the patient to x-rays.

Jalink, Antony, Jr.↗

Comparing Analysis of Hydrogen Concentration in Astromaterials Nominally Anhydrous Minerals by Multiple SIMS

Secondary Ion Mass Spectrometry (SIMS) is utilized to determine hydrogen (H) concentration in astromaterials nominally anhydrous minerals (NAMs) and their inclusions [e.g., 1]. This data is interpreted to refine the volatile history of planetary bodies. Four instruments are being used to compare H concentration analysis: a large geometry SIMS (The University of Hawaiʻi Cameca IMS 1280), a compact SIMS (Arizona State University (ASU) Cameca IMS 6f), and two Cameca NanoSIMS 50L at ASU and NASA-Johnson Space Center (JSC). Results on the first three instruments are available. Although fundamentally similar, SIMS instruments and their modifications [2] may produce different values or pose advantages for H analysis, especially for shocked samples that are susceptible to contamination filling their fractures. New data from the IMS 1280 is reported, using its microchannel plate (MCP) to image high H signals in grain fractures during pre-sputtering to avoid them as much as possible. Between fractures, 16 OH/ 30 Si was measured with a Cs + 4 nA primary beam, 30 micron spot size, and central ~5x5 micron collection area. First order comparison of H concentration (reported in ppm H 2 O) is achieved on a terrestrial gem quality clinopyroxene (SLP114, 162±12 ppm H 2 O [3]), with 157±7 and 215±40 ppm H 2 O by the IMS 1280 and 6f respectively. SIMS comparison is then extended to analysis of two Martian shergottites: RBT 04262 and NWA 5789. Due to a dense fracture network (< 20 micron) in RBT 04262, only one clinopyroxene hosted glassy inclusion was analyzed (n=6, ≤1 ppm H 2 O), while six olivine grains in NWA 5789 (n=12, ≤ 2 ppm H 2 O) (1s ±0.21) were analyzed. Higher concentrations were obtained for RBT 04262 olivine by the ASU NanoSIMS 50L (up to 350 ppm H 2 O [4]), and IMS 6f (300+ ppm H 2 O, [5]), for which contamination in fractures could not be avoided. Work on the JSC NanoSIMS 50L will further develop the SIMS comparison.

J.-M. Dudley↗

Scanning Microscopes Using X Rays and Microchannels

Scanning microscopes that would be based on microchannel filters and advanced electronic image sensors and that utilize x-ray illumination have been proposed. Because the finest resolution attainable in a microscope is determined by the wavelength of the illumination, the xray illumination in the proposed microscopes would make it possible, in principle, to achieve resolutions of the order of nanometers about a thousand times as fine as the resolution of a visible-light microscope. Heretofore, it has been necessary to use scanning electron microscopes to obtain such fine resolution. In comparison with scanning electron microscopes, the proposed microscopes would likely be smaller, less massive, and less expensive. Moreover, unlike in scanning electron microscopes, it would not be necessary to place specimens under vacuum. The proposed microscopes are closely related to the ones described in several prior NASA Tech Briefs articles; namely, Miniature Microscope Without Lenses (NPO-20218), NASA Tech Briefs, Vol. 22, No. 8 (August 1998), page 43; and Reflective Variants of Miniature Microscope Without Lenses (NPO-20610), NASA Tech Briefs, Vol. 26, No. 9 (September 2002) page 6a. In all of these microscopes, the basic principle of design and operation is the same: The focusing optics of a conventional visible-light microscope are replaced by a combination of a microchannel filter and a charge-coupled-device (CCD) image detector. A microchannel plate containing parallel, microscopic-cross-section holes much longer than they are wide is placed between a specimen and an image sensor, which is typically the CCD. The microchannel plate must be made of a material that absorbs the illuminating radiation reflected or scattered from the specimen. The microchannels must be positioned and dimensioned so that each one is registered with a pixel on the image sensor. Because most of the radiation incident on the microchannel walls becomes absorbed, the radiation that reaches the image sensor consists predominantly of radiation that was launched along the longitudinal direction of the microchannels. Therefore, most of the radiation arriving at each pixel on the sensor must have traveled along a straight line from a corresponding location on the specimen. Thus, there is a one-to-one mapping from a point on a specimen to a pixel in the image sensor, so that the output of the image sensor contains image information equivalent to that from a microscope.

Wang, Yu↗

Data compression techniques for astronomy

The photometric and astrometric accuracy of the Minnesota automated dual-plate scanner is summarized. The relation between magnitude and isophotometric image diameter is linear on Schmidt plates over a large useful range. Results of a study of centroid measurement accuracy and image classification ability of parameters derived from both densitometric and isophotometric scanning techniques are presented. The data analyzed for this purpose are synthesized ideal star and galaxy brightness distributions with appropriate random noise added to simulate plate grain and sky background effects. A preliminary study of image classification using real plates and single isophote data finds that a parameter describing the raggedness of the isophote may be useful in distinguising stars from galaxies.

Landau, R.↗

Alinement tool for X-ray image intensifiers

Gage consists of upper plate and lower plate connected by aluminum post marked with metric scale. Upper plate is identical to calibration plate except for post flange. Lower plate is made of aluminum and is grooved for x-y coordinates and pattern of concentric rings that aid in recognition and measurement of nonlinearity. X-y coordinates on upper and lower plates match exactly. Gage indicates amount and direction of skew in images.

Rasmussen, D.↗

Imaging studies of comets

Schmidt camera plates of comet Bradfield were secured on several nights in October 1987. The images of October 20 show the development of a huge bend in the plasma tail travelling several hundred kilometers per second down the tail; the likely solar-wind origin of this event is being explored. A charged coupled device (CCD) detector has been obtained. Calibration of the CCD is still underway, but high-quality, filtered cometary images shoud be possible in the near future.

Niedner, Malcolm B., Jr.↗

Quantum efficiencies of imaging detectors with alkali halide photocathodes. I - Microchannel plates with separate and integral CsI photocathodes

Measurements and comparisons have been made of the quantum efficiencies of microchannel plate (MCP) detectors in the far-UV (below 2000-A) wavelength range using CsI photocathodes (a) deposited on the front surfaces of microchannel plates and (b) deposited on solid substrates as opaque photocathodes with the resulting photoelectrons input to microchannel plates. The efficiences were measured in both pulse-counting and photodiode modes of operation. Typical efficiencies are about 15 percent at 1216 A for a CsI-coated MCP compared with 65 percent for an opaque CsI photocathode MCP detector. Special processing has yielded an efficiency as high as 20 percent for a CsI-coated MCP. This may possibly be further improved by optimization of the tilt angle of the MCP channels relative to the front face of the MCP and incident radiation. However, at present there still remains a factor of at least 3 quantum efficiency advantage in the separate opaque CsI photocathode configuration.

Carruthers, George R.↗

Lamb wave imaging with actuator network for damage quantification in aluminum plate structures

Lamb waves have been widely used for damage detection on plate-like structures. However, there are still considerable interests on quantifying damage with complex profile. In this article, quantification of complex damage in plate-like structures using a network of actuators and time-space Lamb wavefield is investigated. The actuator network inspection system is implemented with multiple PZT transducers for Lamb wave actuation in round robin pattern and scanning laser Doppler vibrometer for wavefield sensing. The PZT network is arranged in a way that the target area is fully enclosed and Lamb waves come to the damage from all directions. Waves induced by the damage are subsequently obtained through frequency-wavenumber filtering, using the experimentally acquired dispersion curves presented in the paper. The filtered waves from all wave actuators are then used to generate a synthetic image of the damage being inspected. Two cases of complex damage are evaluated on aluminum plates, mass loss with triangular profile and mass addition with a three-letter cluster profile. Our results show that the damages are not only detected but also their profiles are clearly outlined in the images. We believe the subject methods provide improved evaluation of damage profile for Lamb wavefield based damage quantification.

Materials Science↗

Detecting X-rays with an optical imaging chamber

The light emitted by electron avalanches in a parallel plate chamber can be used to image the tracks of photoelectrons liberated by the interaction of an incident X-ray with the gas filling the chamber. The different morphologies of photoelectron tracks and minimum ionizing tracks can be used for charged particle rejection. The initial direction (before scattering) of the liberated photoelectron also contains information about the polarization of the incident radiation. We have built a small test chamber with which we have imaged photoelectron tracks using an intensified CCD camera. Our results show that optical imaging could be used in a hard X-ray imaging polarimeter useful for astronomy.

Austin, Robert A.↗

Documentation for the machine-readable version of a deep objective-prism survey for large Magellanic cloud members

This catalog contains 1273 proven or probable Large Magellanic Cloud (LMC) members, as found on deep objective-prism plates taken with the Curtis Schmidt telescope at Cerro Tololo Inter-American Observatory in Chile. The stars are generally brighter than about photographic magnitude 14. Approximate spectral types were determined by examination of the 580 A/mm objective-prism spectra; approximate 1975 positions were obtained by measuring relative to the 1975 coordinate grids on the Uppsala-Mount Stromlo Atlas of the LMC (Gascoigne and Westerlund 1961), and approximate photographic magnitudes were determined by averaging image density measures from the plates and image-diameter measures on the 'B' charts. The machine-readable version of the LMC survey catalog is described to enable users to read and process the tape file without problems or guesswork.

Warren, W. H., Jr.↗

Structure of the Ecuadorian Upper Plate From a Joint Seismic‐Gravity Inversion

The Ecuadorian portion of the South American subduction zone presents an interesting case study in the structure and complex evolution of an upper plate. There are outstanding questions about its tectonic history, composition, and magmatic processes. While previous studies have employed ambient noise tomography to image the Ecuadorian upper plate, surface wave inversions alone often lack sensitivity at relevant shallow depths. This limitation can be overcome with an independent, complementary data set, such as gravity. We have jointly inverted Rayleigh wave phase velocities and Bouguer gravity anomalies to provide a more detailed seismic velocity model of the Ecuadorian upper plate. Our joint inversion has yielded several key improvements from previous models. First, we observe much shallower slow velocities beneath major basins (the Manabí, Progreso, and Gulf of Guayaquil), better aligning with expected basin structure. Second, we identify a high-velocity block beneath the entire forearc, corresponding to the Piñon Terrane, with velocities suggesting the presence of ultramafic material. Third, we highlight a new narrow swath of slow velocities beneath the Ecuadorian Andes, which closely follows the active volcanoes along the Eastern Cordillera. The extent of these slow velocities coincides with the termination of active arc volcanism and the predicted location of the subducted Carnegie Ridge. The predicted compositions for the mid to lower crust in the region preclude a purely compositional explanation for these velocities, suggesting that some level of partial melt is necessary.

Birkey, Andrew [Univ. of Delaware, Newark, DE (Uni↗

Correcting the distortion of images taken with the ultraviolet imaging telescope

The Ultraviolet Imaging Telescope (UIT) cameras include two-stage magnetically focused image intensifiers that introduce small but significant geometrical distortions into the data. These distortions, which create positional offsets as large as 25 arcsec at the field edges, are corrected by the procedure described here to 2-3 arcsec, approximately the resolution of the images. The distortion is measured by comparing and correcting UIT images to digitized Guidestar survey plates of the same fields. Two-dimensional third-order polynomials are used to model the distortion. The models assume that the distortion is an instrumental effect, independent of mission elapsed time and target, and that the effect of distortion is an instrumental effect, independent of mission elapsed time and target, and that the effect of distortion in the center of each field is minimal. The models are used to improve computed astrometric plate solutions and to remove the geometric distortion while transforming the image to a standard north-up, ease-left orientation.

Greason, M. R.↗

The Photicon

The Photicon is a novel imaging optical detector utilizing a conventional semitransparent photocathode, imaging electrostatic optics, microchannel plates, and a crossed-wire-grid position-sensitive charge detector. Its sensitivity to single optical photons over a two-dimensional area, high-resolution imaging, and timing capability render it useful for recording scintillations from X-ray image converters in X-ray astronomy. A digital word indicating the position of a single photon event is produced; the image can be stored in an array or serially. Spatial resolution to 20 microns in a 25 mm diam active area detector is reported, and modifications to achieve a spectral range of 120-730 nm are mentioned.

Kellogg, E.↗

Strong Upper-Plate Heterogeneity at the Hikurangi Subduction Margin (North Island, New Zealand) Imaged by Adjoint Tomography

We use earthquake-based adjoint tomography to invert for three-dimensional structure of the North Island, New Zealand, and the adjacent Hikurangi subduction zone. The study area, having a shallow depth to the plate interface below the North Island, offers a rare opportunity for imaging material properties at an active subduction zone using land-based measurements. Starting from an initial model derived using ray tomography, we perform iterative model updates using spectral element and adjoint simulations to fit waveforms with periods ranging from 4–30 s. We perform 28 model updates using an L-BFGS optimization algorithm, improving data fit and introducing P- and S-wave velocity changes of up to ±30%. Resolution analysis using point spread functions show that our measurements are most sensitive to heterogeneities in the upper 30 km. The most striking velocity changes coincide with areas related to the active Hikurangi subduction zone. Lateral velocity structures in the upper 5 km correlate well with New Zealand geology. Here, the inversion reveals increased along-strike heterogeneity on the margin. In Cook Strait we observe a low-velocity zone interpreted as deep sedimentary basins. In the central North Island, low-velocity anomalies are linked to surface geology, and we relate velocity structures at depth to crustal magmatic activity below the Taupō Volcanic Zone.

58 GEOSCIENCES↗

Characteristics of a microchannel plate intensifier

A telephoto optical system has been designed for imaging applications involving a use of the spectral region from 2000 to 7500 A. The optics images onto the photocathode of a multichannel plate photomultiplier (PMT). Interference filters are employed to provide spectral selectivity. The PMT consists of three microchannel plate intensifiers (MCP), arranged in a 'Z' configuration. MCP photomultiplier pulse height distributions are discussed along with aspects of spatial distribution, the electron gain pulse height distribution, and the charge loss due to edge effects. Attention is given to the electron gain pulse height distribution obtained from four anodes connected in parallel, taking into account a uniform illumination of the photocathode.

Sandie, W. G.↗

Development of high resolution imaging detectors for x ray astronomy

This final report summarizes our past activities and discusses the work performed over the period of 1 April 1990 through 1 April 1991 on x-ray optics, soft x-ray (0.1 - 10 KeV) imaging detectors, and hard x-ray (10 - 300 KeV) imaging detectors. If microchannel plates (MCPs) can be used to focus x-rays with a high efficiency and good angular resolution, they will revolutionize the field of x-ray optics. An x-ray image of a point source through an array of square MCP pores compared favorably with our ray tracing model for the MCP. Initial analysis of this image demonstrates the feasibility of MCPs for soft x-rays. Our work continues with optimizing the performance of our soft x-ray MCP imaging detectors. This work involves readout technology that should provide improved MCP readout devices (thin film crossed grid, curved, and resistive sheets), defect removal in MCPs, and photocathode optimization. In the area of hard x-ray detector development we have developed two different techniques for producing a CsI photocathode thickness of 10 to 100 microns, such that it is thick enough to absorb the high energy x-rays and still allow the photoelectrons to escape to the top MCP of a modified soft x-ray imaging detector. The methods involve vacuum depositing a thick film of CsI on a strong back, and producing a converter device that takes the place of the photocathode.

Murray, S. S.↗

Application of wedge and strip image readout systems to detectors for astronomy

Microchannel plate (MCP) detector systems that use wedge and strip anodes for imaging radiation in the range 50 A to 8000 A are described. Test data, obtained from the calibration of the Extreme Ultraviolet Explorer Satellite detectors and the ARIA EUV aeronomy sensor is presented. The long-term performance characteristics of Z-stack microchannel plates are investigated and it is shown that stable operation is achieved after an initial settling period. Conventional and new anode designs and their potential for increasing the position resolution are discussed. Position resolution of better than 80 microns FWHM has been attained for 50 mm devices, and this is shown to be essentially independent of event location. Image nonlinearity of less than 0.3 percent has been achieved with stability to better than 0.1 percent. Differential nonlinearity of less than 1 percent and stability to better than 1 percent have been obtained. Measurements of the quantum efficiency of a CsI photocathode on an MCP are presented, demonstrating efficiencies as high as 47 percent.

Siegmund, O. H. W.↗

Design, Testing, and Implementation of the Marshall Grazing Incidence X-ray Spectrometer Slit-Jaw Context Imaging System

The Marshall Grazing Incidence X-ray Spectrometer (MaGIXS) is a NASA sounding rocket payload providing a 0.6 – 2.5 nm spectrum with unprecedented spatial and spectral resolution. The instrument is comprised of a novel optical design, featuring a Wolter 1 grazing mirror in the telescope module focusing the solar image on a slit plate; two corrective optics, a diffraction grating and a low-noise detector make up the spectrometer module. When MaGIXS flies on a suborbital launch in 2020, a slit-jaw camera system will image the sun in extreme ultraviolet (EUV) to soft x-ray wavelengths, providing a reference for pointing the telescope and aligning the data to supporting observations from satellites.

Phillip Wilkerson↗