Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “INTERCONNECTED POWER SYSTEMS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Advanced Power Electronics Designs - Reliability and Prognostics

The electrical interconnection and isolation design aspects within an inverter must also provide high thermal performance and thermomechanical reliability. In collaboration with ORNL, DuPont, and Indiana Integrated Circuits (IIC), NREL is evaluating new packaging materials and manufacturing techniques for wide-bandgap-based traction inverters. Thermal modeling and experimental evaluation revealed that an organic direct-bond-copper (ODBC) substrate has similar thermal resistance to traditional ceramic substrates. High-temperature thermal cycling has shown the ODBC substrates to have greater reliability than ceramic substrates which is a significant finding in the quest for low-cost, power-dense, high-temperature power electronics. IIC's direct chip-to-chip topside electrical connection will be attached to ODBC substrates and reliability evaluation for both technologies will be performed at NREL in Q4.

30 DIRECT ENERGY CONVERSION↗

The Application of Droop-Control in Distributed Energy Resources to Extend the Voltage Collapse Margin

The growth in distributed energy resources has the potential to reduce system stresses caused by transmission grid congestion by supplying power and voltage regulation closer to load centers. However, the additional voltage regulation provided by these resources can mask the onset of voltage collapse. Local voltage support flattens the slope in the upper region of the power-voltage nose curve. Coordinating voltage-regulation behavior with the droop-control scheme in distributed resources improves the observation of voltage collapse margins. Incorporating distributed resource models in the continuation power flow analysis, allows the exploration of the power transfer gains by the application of distributed resources. The analysis provides insight to the impact of droop control on the behavior of the power-voltage curve and voltage collapse. The analysis is applied to a fixed speed induction generator wind farm with separate reactive compensation and the interconnection to the local power system. Results reveal that coordinating the droop control strategy allows the distributed resource to significantly increase the voltage collapse margin without hiding the threat of voltage stability problems.

17 WIND ENERGY↗

The Effect of Power Electronic Loads on Western Interconnection Stability

The prevalence of power electronics in the bulk power system is increasing rapidly in both the generation and consumption of electricity. This work focuses on the effect of changing load composition - specifically the transition from single phase air conditioner motors to power electronics backed air conditioners - on power system stability. Various transmission and generation contingency events for the Western Interconnection were simulated using Positive Sequence Load Flow software and planning models from the Western Electricity Coordinating Council. In general, an increased proportion of power electronic load leads to more instability. For some specific faults resulting in fault-induced delayed voltage recovery, transitioning to higher proportions of power electronic loads helps expedite system recovery. These results demonstrate that load composition should be examined in conjunction with generation composition when evaluating system stability.

FIDVR↗

Exascale Hardware Architectures Working Group

The ASC Exascale Hardware Architecture working group is challenged to provide input on the following areas impacting the future use and usability of potential exascale computer systems: processor, memory, and interconnect architectures, as well as the power and resilience of these systems. Going forward, there are many challenging issues that will need to be addressed. First, power constraints in processor technologies will lead to steady increases in parallelism within a socket. Additionally, all cores may not be fully independent nor fully general purpose. Second, there is a clear trend toward less balanced machines, in terms of compute capability compared to memory and interconnect performance. In order to mitigate the memory issues, memory technologies will introduce 3D stacking, eventually moving on-socket and likely on-die, providing greatly increased bandwidth but unfortunately also likely providing smaller memory capacity per core. Off-socket memory, possibly in the form of non-volatile memory, will create a complex memory hierarchy. Third, communication energy will dominate the energy required to compute, such that interconnect power and bandwidth will have a significant impact. All of the above changes are driven by the need for greatly increased energy efficiency, as current technology will prove unsuitable for exascale, due to unsustainable power requirements of such a system. These changes will have the most significant impact on programming models and algorithms, but they will be felt across all layers of the machine. There is clear need to engage all ASC working groups in planning for how to deal with technological changes of this magnitude. The primary function of the Hardware Architecture Working Group is to facilitate codesign with hardware vendors to ensure future exascale platforms are capable of efficiently supporting the ASC applications, which in turn need to meet the mission needs of the NNSA Stockpile Stewardship Program. This issue is relatively immediate, as there is only a small window of opportunity to influence hardware design for 2018 machines. Given the short timeline a firm co-design methodology with vendors is of prime importance.

97 MATHEMATICS AND COMPUTING↗

Security Evaluation of Two Intrusion Detection Systems in Smart Grid SCADA Environment

The increased complexity and interconnectivity of SCADA infrastructure in the power system have exposed it to the multitude of vulnerabilities. There is a growing emphasis towards developing an efficient intrusion detection system (IDS) to strengthen the security of the SCADA control system. This is a research-in-progress paper which presents the application of two anomaly-based intrusion detection systems (AIDS) in detecting the stealthy cyber-attack on the SCADA control system. We have applied the IDS tools Snort and Bro, in designing the IDS and later, compared their performances in terms of detection rate and latency in the alert packets with a motive of selecting better IDS for the SCADA security. Specifically, the timing-based rule is applied to identify the malicious packets based on the high temporal frequency in the network traffic. For the case study, we have implemented the SCADA based protection scheme which performs an autonomous protection to mitigate the system disturbances. We first implemented the stealthy cyber-attack which compromised the SCADA controller followed by data integrity attack on the system generator. Next, we perform the impact analysis during the attack followed by performance evaluation of IDS tools. Our experimental results show that the IDS tools are efficient in detecting cyber-attacks within an acceptable time frame for different sizes of network packets.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Anomaly Detection and Mitigation for Wide-Area Damping Control using Machine Learning

In an interconnected multi-area power system, wide-area measurement based damping controllers are used to damp out inter-area oscillations, which jeopardize grid stability and constrain the power flows below to their transmission capacity. The effect of wide-area damping control (WADC) significantly depends on both power and cyber systems. At the cyber system layer, an adversary can inflict the WADC process by compromising either measurement signals, control signals or both. Stealthy and coordinated cyber-attacks may bypass the conventional cybersecurity measures to disrupt the seamless operation of WADC. This paper proposes an anomaly detection (AD) algorithm using supervised Machine Learning and a model-based logic for mitigation. The proposed AD algorithm considers measurement signals (input of WADC) and control signals (output of WADC) as input to evaluate the type of activity such as normal, perturbation (small or large signal faults), attack and perturbation-and-attack. Upon anomaly detection, the mitigation module tunes the WADC signal and sets the control status mode as either wide-area mode or local mode. The proposed anomaly detection and mitigation (ADM) module works inline with the WADC at the control center for attack detection on both measurement and control signals and eliminates the need for ADMs at the geographically distributed actuators. Here, we consider coordinated and primitive data-integrity attack vectors such as pulse, ramp, relay-trip and replay attacks. The performance of the proposed ADM algorithms was evaluated under these attack vector scenarios on a testbed environment for 2-area 4-machine power system. The ADM module shows effective performance with 96:5% accuracy to detect anomalies.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Highlights of IEEE Standard 1547-2018

This presentation contains highlights of technical requirements for DER integration prescribed in IEEE Standard 1547-2018.

24 POWER TRANSMISSION AND DISTRIBUTION↗

MN Solar Pathways: Enhanced Hosting Capacity Analysis

As part of the Minnesota Solar Pathways project, funded in part by the Department of Energy’s Solar Energy Technologies Office, Smarter Grid Solutions (SGS) completed an evaluation of emerging technologies as non-wires alternatives to integrate solar PV. SGS evaluated stand-alone smart inverters, centrally coordinated smart inverters, thermal load shifting, energy storage, and a combined technology scenario to compare and contrast the benefits at four distribution feeders. The analysis showed that there is not a “one size fits all” answer to increasing hosting capacity beyond a feeder’s static limit, since each feeder faces different constraints.

14 SOLAR ENERGY↗

A Sensemaking Perspective on Situation Awareness in Power Grid Operations

With increasing complexity and interconnectivity of the electric power grid, the scope and complexity of grid operations continues to grow. New paradigms are needed to guide research to improve operations by enhancing situation awareness of operators. Research on human factors/situation awareness is described within a taxonomy of tools and approaches that address different levels of cognitive processing. While user interface features and visualization approaches represent the predominant focus of human factors studies of situation awareness, this paper argues that a complementary level, sensemaking, deserves further consideration by designers of decision support systems for power grid operations. A sensemaking perspective on situation aware-ness may reveal new insights that complement ongoing human factors research, where the focus of the investigation of errors is to understand why the decision makers experienced the situation the way they did, or why what they saw made sense to them at the time.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Generator Interconnection Cost Analysis in the Southwest Power Pool (SPP) Territory

Electric transmission system operators (ISOs, RTOs, or utilities) require new large generators seeking to connect to the grid to undergo a series of impact studies before they can be built. This process establishes what new transmission equipment or upgrades may be needed before a project can connect to the system and assigns the costs of that equipment. Berkeley Lab has collected interconnection cost data for 845 projects from interconnection studies for the Southwest Power Pool (SPP) Territory. The studies were performed between 2002 and 2023 and include all of the most refined cost estimates available. Project-level cost summary data are available for download on this page. We find: -Project-specific interconnection costs can differ widely. -Average interconnection costs are stable for projects that complete all interconnection studies but have escalated for those that withdraw. -Broader network upgrade costs are the primary driver of recent cost increases, especially for withdrawn projects. -Potential interconnection costs of all solar and wind requests have been greater than those of storage and natural gas projects. -Economies of scale exist for completed wind and solar projects but not for other fuel types or withdrawn projects. -Interconnection costs vary by location. Berkeley Lab publishes a series of short analytical papers of generator interconnection costs to the transmission system for MISO, PJM, SPP, ISO-NE and NYISO, which you can find at https://emp.lbl.gov/interconnection_costs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

FY2018 Discovery Through Situational Awareness: Anomalies, Oscillations, and Classification

This technical report is a summary of work performed under the DOE GMLC program under the task titled “Discovery through Situational Awareness”. The focus of this work was to apply big data, statistical techniques to PMU data to do the following: 1) baseline PMU data and find anomalies with a focus on phase angle pairs, 2) identify the frequencies of dominant modal oscillations between different parts of a power system, and 3) identify and classify frequency events in PMU data. This work was performed on PMU data from the Western Interconnect. Many of these algorithms will be applied to wide area phase angle pair data on the Eastern Interconnect in a tool called ESAMS (Eastern Interconnect Situational Awareness Monitoring System). ESAMS was built by EPG (Electric Power Group) and PNNL and is currently being installed on the Eastern Interconnect. The results discussed in this report were made from 14 PMUs from data ranging from Oct 2016 to May 2018. The PMU data were measured 60 times each second. Fourteen phase angle pairs were included, with reactive and active power being calculated at 14 sites. All results have been de-identified for this report. The methodologies applied in the ESAMS tool are described in Section 2. A baseline of PMU data is created using the last 120 days of data. This baseline describes typical behavior as understood from the data. The baseline is then applied to the next day’s data and anomalies from that baseline are identified. Plots are created to help describe what is anomalous during that specific moment in time. These algorithms are currently being installed on the Eastern Interconnect. FY19 work will include discussing the results and findings from the ESAMS tool. A new method of identifying the frequencies of dominant modal oscillations between different parts of a power system is described in Section 3. A list of 199 frequency events provided by Bonneville Power Administration were used to create algorithms to detect frequency events and to create classification rules that can be used to identify future frequency events. Section 4 discusses the results the performance of 7 different event detection, clustering-based methods. Accuracy percentages ranged from 93.59% to 99.16%, with most methods being very fast. GBM (Gradient Boosting Machine) performed well and quickly. These 7 different methods were also tested to determine how well each built classification rules on training data and then applied those rules to identify future frequency events. Accuracy percentages ranged from 89.09% to 99.9%, with all methods performing quickly. GLM (General Linear Model) was viewed as the top performer when considering accuracy and processing time. Because the list of events consisted of 80% of them as active power events and only 20% as faults, all methods struggled to identify events as faults. Small faults were especially difficult to identify. A separate algorithm was created to help with this. Additional work will be done in FY19 on event detection using more data and more events and refinements to the methods.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Lower Snake River Dams Contribution to Grid Services

Hydroelectric generation and water storage have long been components of the clean energy mix, providing both reliable steady output and operational flexibility. As variable renewable energy sources such as wind and solar increasingly replace traditional generation, the role of all flexible resources—including hydropower—in balancing supply and demand continues to evolve. This study examined the contribution of the Lower Snake River (LSR) Dam plants to Bonneville Power Administration grid services in maintaining power system reliability within the Western Interconnection. By analyzing publicly available data, the study evaluated various reliability services through performance metrics including energy capacity, balancing and ramping, voltage and reactive power support, frequency response, and transmission impact. Results indicated that the LSR plants deliver services as expected based on their size, contributing to the balancing process, ramping capabilities, and operational reserves, particularly during peak load conditions and weather events, while also providing measurable frequency and voltage support to the grid.

13 HYDRO ENERGY↗

Estimation of Electromechanical Modes of Oscillation in the Eastern Interconnection from Ambient PMU Data

A power system's inter-area electromechanical modes of oscillation determine if the system is small-signal stable. Mode meters are tools that estimate the modes based on ambient synchrophasor measurements, allowing continuous monitoring of the system's stability margin. This paper reports on the application of mode meter algorithms to 21 months of synchrophasor measurements from the United States Eastern Interconnection (EI). Estimates for three modes were updated every minute, providing a much more comprehensive set of results than previous studies based on disturbance recordings. The detailed signal designs and mode meter configurations provided in this paper can be used to accelerate mode meter deployments in the EI. Analysis of the mode estimates reveal for the first time how seasonal load changes and system reconfiguration impact the EI system's dynamics.

Follum, James D.↗

Performance Test Protocol for Evaluating Inverters Used in Grid-Connected Photovoltaic Systems

Interconnection equipment that connects distributed resources (DR) to an electrical power system (EPS) are expected to do so efficiently. Standardized test procedures are necessary to establish methods for verifying inverter performance that leads to comparable results. These test procedures are provided as a repeatable, independent means of measuring inverter performance regarding maximum continuous power rating, conversion efficiency, and tare loss characteristics.

14 SOLAR ENERGY↗

Qualification and life testing of a flight design hydrazine arcjet system

This paper describes the design and the requirements of a low-power hydrazine arc jet system and presents the results of tests on the system's performance, vibration, and lifetime. The system consists of an arcjet, catalyst bed, power control unit, and interconnecting power cable. Operating at 1.4 kW input power, the system provides a minimum of 450 sec mission average specific impulse, yielding greater than a 100 kg propellant savings over standard monopropellant or bipropellant systems used on communication satellites.

Knowles, S. C.↗

Grid-Forming Inverters: Project Demonstrations and Pilots

Power system operators around the world are pushing the limits of integrating inverter-based resources (IBRs) to very high levels, approaching 100% instantaneous penetration under certain operating conditions. This often applies to smaller power systems with very little or no ac interconnections to other neighboring regions or sometimes to fringes of large balancing areas, such as Denmark or Portugal, within the mainland European power system. These jurisdictions have identified the potential of grid-forming (GFM) technology as a key enabler to support the energy transition with very few or no synchronous generators online. Until recently, practical applications of GFM inverters were limited to microgrids and isolated grids and in smaller grid applications on the order of a few tens of megawatts (MW).

Australia↗