Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ICP MS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Activation of CO 2 by Actinide Cations (Th + , U + , Pu + , and Am + ) as Studied by Guided Ion Beam and Triple Quadrupole Mass Spectrometry

Reactions of CO 2 with Th+ have been studied using guided ion beam tandem mass spectrometry (GIBMS) and with An + (An + = Th + , U + , Pu + , and Am + ) using triple quadrupole inductively coupled plasma mass spectrometry (QQQ-ICP-MS). Additionally, the reactions ThO + + CO and ThO + + CO 2 were examined using GIBMS. Modeling the kinetic energy dependent GIBMS data allowed determination of bond dissociation energies (BDEs) for D o (Th + -O) and D o (OTh + -O) that are in reasonable agreement with previous GIBMS measurements. The QQQ-ICP-MS reactions were studied at higher pressures where multiple collisions between An + and the neutral CO 2 occur. As a consequence, both AnO + and AnO 2 + products were observed for all An + except Am + , where only AmO + was observed. Here, the relative abundances of the observed monoxides compared to the dioxides are consistent with previous reports of the AnO n + (n = 1, 2) BDEs. Comparison of the periodic trends of the group 4 transition metal, lanthanide (Ln), and actinide atomic cations in reactions with CO 2 (a formally spin-forbidden reaction for most M + ground states), and O 2 (a spin unrestricted reaction) indicate that spin conservation plays a minor role, if any, for the heavier An + metals. Further correlation of Ln + and An + + CO 2 reaction efficiencies with the promotion energy (E p ) to the first electronic state with two valence d-electrons (E p (5d 2 ) for Ln + and E p (6d 2 ) for An + ) indicates that the primary limitation in the activation of CO 2 is the energetic cost to promote from the electronic ground state of the atomic metal ion to a reactive state.

bond activation↗

Worswick Hot Springs: A Radioactive Hydrothermal Field Site.

Introduction: We report on a systematic characterization of the environmental conditions at Worswick Hot Springs, a hydrothermal system in Idaho, USA. Because localized “hot spots” of elevated radiation and biofilms are easily accessible, various biological studies of radiation resistance and biosignature formation are possible, making this fieldsite relevant for analog field studies that consider microbiology, geo-chemistry, and ionizing radiation. In addition to Worswick being a natural radiation biology laboratory that may also be relevant for space biology applications, we assert that these unusual environmental conditions may inform us about locations on Mars that are also enriched in radioactive elements and their poten-tial for hosting biosignatures. Methods: We carried out repeated temperature and radiation measurements at the same hot spring locations to observe the system over time (Figure 2). Radiation: A Bicron Micro Analyst micro-r-meter (Bicron NE, Saint-Gobain Industrial Ceramics, Inc.) capable of sensing x-rays and gamma-rays (0-5000 µR/hr), was used to gather radiation data at twenty-four locations around and above the region of the two main stream channels. Water Temperature: A digital hand-held infrared thermometer (Oakton WD-39642-00 Mini-Temp Tester) was used for all measurements. ICP-MS aqueous geochemistry: Water samples were analyzed at the ISU Center for Archaeology, Materials and Applied Spectroscopy (CAMAS). Results: We have discovered localized areas of elevated radiation that are approximately 4 to 5 times greater than background radiation, and we have ob-served that both radioactivity and temperature of the spring waters vary over time. ICP-MS reveal the presence of thorium and uranium, which are correlated with elevated radioactivity. Several point sources of elevated radioactivity have been identified in both Stream A and Stream B.

Analog↗

An Evaluation of Actinide Reactivity with CO 2 , O 2 , and O 2 /He Gases using Inductively Coupled Plasma Tandem Mass Spectrometry: Application to Simultaneous Measurement of 241 Am/ 241 Pu Ratios in Unseparated Complex Matrices

Accurate actinide measurements are critical within the field of nuclear science. Traditional methods for actinide quantification require time-consuming sample processing prior to analysis. There is a need for rapid analytical techniques that still maintain a high degree of accuracy. In this work, actinide reactivity was assessed for multiple oxygen-containing reaction gases using quadrupole inductively coupled plasma tandem mass spectrometry (Q-ICP-MS/MS) to evaluate actinide analysis in complex sample matrices without analyte-matrix separation. A novel method was developed to measure 241 Am/ 241 Pu in complex sample matrices using O 2 /He reaction gas with no matrix removal or analyte pre-concentration. This inline method reduces matrix-derived polyatomic interferences that complicate traditional ICP-MS analyses by mass-shifting to 241 Am 16 O + and 241 Pu 16 O 2 + , allowing Am and Pu to be mass separated for simultaneous analysis. While mass shifting is efficient, a small portion of Am + (<1.3%) and Pu + (<1.4%) react to from AmO 2 + and PuO + , respectively. Therefore, a mass balance approach was used, in combination with reactivity determined from 242 Pu and 243 Am standard solutions, to correct for residual 241 PuO + and 241 AmO 2 + . The method was validated by measuring 241 Am/ 241 Pu in Pu isotope standards CRM-136 and CRM-137 (separated in March/April 1970 and February 2022, respectively) in both neat solutions and complex matrices containing diluted soil (NIST SRM 2711a, >1000 µg·g -1 ). Method detection limits of 15.9 and 9.6 fg·g -1 were determined for 241 Am and 241 Pu, respectively, and 241 Am/ 241 Pu ratios were measured with accuracies within <3.5%. In conclusion, this work presents the first direct analysis of 241 Am/ 241 Pu in unseparated complex matrices, advancing capabilities for rapid actinide measurements.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

230Th/234U radiochronometry for uranium materials by alpha spectrometry for nuclear forensics analysis

We have developed an alpha spectrometry method for 230Th/234U radiochronometry to determine the model separation age for uranium materials. This method offers an alternative to the more commonly used, but significantly more resource intensive multi-collector inductively coupled plasma mass spectrometry (MC-ICP-MS) while providing similar accuracy and precision. The development included radiochemical separation of uranium and thorium, calibration of the 232U tracer and the alpha spectrometry measurement. The method was validated by analyzing a certified reference material, CRM 125-A, which is a uranium oxide pellet assay, isotopic, and radiochronometric standard. The results were compared to those obtained by our routine MC-ICP-MS 230Th/234U radiochronometry analysis method to assess the performance parameters for alpha spectrometry compared to the state-of-the-art technique.

Macsik, Zsuzsanna [Los Alamos National Laboratory ↗

Simultaneous Determination of Halogens and Metals in Waste Plastic Pyrolysis Oil by Inductively Coupled Plasma Mass Spectrometry

A major barrier to integrating pyrolysis-derived oil into conventional refinery technology is the presence of impurities, particularly halogens and metals, that can deactivate catalysts. This study presents a novel, cost-effective approach for the simultaneous analysis of a subset of halogens, metals, nonmetals, and metalloids in complex, industrially relevant distilled pyrolysis oil samples, this was previously achievable only through multiple techniques. Excellent results were obtained using a widely accessible inductively coupled plasma mass spectrometry (ICP-MS) method with helium gas mode and standard laboratory consumables, enabling high-throughput analysis and efficient evaluation of adsorbent performance. Sample preparation is straightforward, requiring only dilution in a compatible matrix, and provides accurate and precise quantification, with 75%–137% spike recovery for Be, Ti, V, Cr, Fe, Ni, Co, Cu, As, Se, Mo, Cd, Sb, Tl, and Pb, and 62%–65% spike recovery for Cl and 109%–133% spike recovery for Br. Additionally, an enhanced version of the method using ICP-MS/MS and hydrogen gas is described, which has higher accuracy with 69%–112% spike recovery for Be, B, Ti, V, Fe, Co, Ni, Cu, As, Se, Mo, Cd, Sb, Tl, and Pb, with 85%–102% spike recovery for Cl and 63%–93% spike recovery for Br. Helium mode detection limits for industrially relevant elements (V, Fe, Ni, Cu, As, and Pb) are less than 1.7 µg/kg, and less than 0.2 mg/kg for Br and Cl. Furthermore, this methodology facilitates rapid systematic evaluation of adsorption capacities of materials under time-on-stream conditions and supports robust comparisons across diverse operating environments.

Lazarcik, James [University of Wisconsin-Madison, ↗

Center for Isotope Cosmochemistry and Geochronology at NASA Johnson Space Center

Ten years in the making the Center for Isotope Cosmochemistry and Geochronology (CICG) at NASA Johnson Space Center is designed to be a cooperative analytical facility where novel techniques are developed and performed. Our team works collaboratively to operate this integrated lab suite comprising sample preparation, metal-free clean chemistry, and mass spectrometers to measure a wide variety of elements and isotopes in astromaterials. Contamination control is enacted throughout by a positive pressure cascade of HEPA filtered air, weekly surface cleaning and particle counting. Astromaterials processing is performed with application-specific mortar and pestles, heavy liquid separation, a Frantz magnetic separator, as well as hand-picking using optical microscopes in laminar flow boxes. Microsampling is also carried out using a New Wave MicroMill. Elements for isotopic analysis are isolated from acid-digested samples using ion-exchange chromatography. Cross-contamination is minimized with dedicated laminar flow boxes and labware for different purification protocols. Instrumentation includes a ThermoFisher Element XR inductively coupled plasma mass spectrometer (ICP-MS) for quantification of elemental concentrations in dissolved sample solutions. For in situ analysis, a Teledyne Photon Machines Analyte Excite+ laser ablation system is coupled to the Element XR. The ThermoFisher Triton thermal ionization mass spectrometer (TIMS) is used to measure the isotopic composition of elements such as CA, K, Cr, Rb, Sr, Sm, Nd at high precision in processed samples. For a more diverse range of isotopic analyses, CICG houses a Nu Sapphire 1700 multi-collector inductively coupled plasma mass spectrometer (MC-ICP-MS), which is a large geometry instrument with a multi-pole collision cell for interference removal. An Applied Spectra Instruments J200 femto-second laser is planned for install this Fall and will be coupled to the Nu Sapphire 1700. NASA’s Internal Scientist Funding Model (ISFM)supports this facility. Advanced analytical geochemistry techniques are applied to targeted astromaterials to address important problems in planetary sciences, with a longer-term goal of preparing for samples collected and returned by space missions. CICG is open to collaborations on projects that utilize the facility’s unique capabilities and are within its research scope. We are particularly eager to support and share expertise with the next generation of planetary scientists.

Justin I Simon↗

Determination of Mercury Content in a Shallow Firn Core from Summit, Greenland by Isotope Dilution Inductively Coupled Plasma Mass Spectrometry

The total mercury Hg content was determined in 6 cm sections of a near-surface 7 m firn core and in surrounding surface snow from Summit, Greenland (elevation: 3238 m, 72.58 N, 38.53 W) in May 2001 by isotope dilution cold-vapor inductively coupled plasma mass spectrometry (ID-CV-ICP-MS). The focus of this research was to evaluate the capability of the ID-CV-ICPMS technique for measuring trace levels of Hg typical of polar snow and firn. Highly enriched Hg-201 isotopic spike is added to approximately 10 ml melted core and thoroughly mixed. The Hg(+2) in the sample is reduced on line with tin (II) chloride (SnCl2) and the elemental Hg (Hg(0)) vapor pre-concentrated on to gold gauze using a commercial amalgam system. The Hg is then thermally desorbed and introduced into a quadrupole ICP-MS. The blank corrected Hg concentrations determined for all samples ranged from 0.25 ng/L to 1.74 ng/L (ppt) (average 0.59 ng/L plus or minus 0.28 ng/L) and fall within the range of those previously determined by Boutron et al., 1998 (less than or equal to 0.05 ng/L to 2.0 ng/L) for the Summit site. The average blank value was 0.19 ng/L plus or minus 0.045 ng/L (n=6). The Hg values specifically for the firn core range from 0.25 ng/L to 0.87 ng/L (average 0.51 ng/L plus or minus 0.13 ng/L) and show both values declining with time and larger variability in concentration in the top 1.8 m.

Mann, Jacqueline L.↗

Corrosion Compatibility of Stainless Steels and Nickel in Pyrolysis Biomass-Derived Oil at Elevated Storage Temperatures

Corrosion compatibility of stainless steels and nickel (Ni200) was assessed in fast pyrolysis bio-oil produced from pyrolysis of high ash and high moisture forest residue biomass. Sample mass change, ICP-MS and post-exposure electron microscopy characterization was used to investigate the extent of corrosion. Among the tested samples, type 430F and type 316 stainless steels (SS430F and SS316) and Ni200 (~98.5% Ni) showed minimal mass changes (less than 2 mg∙cm−2) after the bio-oil exposures at 50 and 80 °C for up to 168 h. SS304 was also considered to be compatible in the bio-oil due to its relatively low mass change (1.6 mg∙cm−2 or lower). SS410 samples showed greater mass loss values even after exposures at a relatively low temperature of 35 °C. Fe/Cr values from ICP-MS data implied that Cr enrichment in stainless steels would result in a protective oxide layer associated with corrosion resistance against the bio-oil. Post exposure characterization showed continuous and uniform Cr distribution in the surface oxide layer of SS430F, which showed a minimal mass change, but no oxide layer on a SS430 sample, which exhibited a significant mass loss.

09 BIOMASS FUELS↗

Measuring calcium content in plants using NEXAFS spectroscopy

Calcium is important for the growth and development of plants. It serves crucial functions in cell wall and cell membrane structure and serves as a secondary messenger in signaling pathways relevant to nutrient and immunity responses. Thus, measuring calcium levels in plants is important for studies of plant biology and for technology development in food, agriculture, energy, and forest industries. Often, calcium in plants has been measured through techniques such as atomic absorption spectrophotometry (AAS), inductively coupled plasma–mass spectrometry (ICP-MS), and electrophysiology. These techniques, however, require large sample sizes, chemical extraction of samples or have limited spatial resolution. Here, we used near-edge X-ray absorption fine structure (NEXAFS) spectroscopy at the calcium L- and K-edges to measure the calcium to carbon mass ratio with spatial resolution in plant samples without requiring chemical extraction or large sample sizes. We demonstrate that the integrated absorbance at the calcium L-edge and the edge jump in the fluorescence yield at the calcium K-edge can be used to quantify the calcium content as the calcium mass fraction, and validate this approach with onion epidermal peels and ICP-MS. We also used NEXAFS to estimate the calcium mass ratio in hypocotyls of a model plant, Arabidopsis thaliana , which has a cell wall composition that is similar to that of onion epidermal peels. These results show that NEXAFS spectroscopy performed at the calcium edge provides an approach to quantify calcium levels within plants, which is crucial for understanding plant physiology and advancing plant-based materials.

59 BASIC BIOLOGICAL SCIENCES↗

Selenium tolerance, accumulation, localization and speciation in a Cardamine hyperaccumulator and a non-hyperaccumulator

Cardamine violifolia (family Brassicaceae ) is the first discovered selenium hyperaccumulator from the genus Cardamine with unique properties in terms of selenium accumulation, i.e., high abundance of selenolanthionine. In our study, a fully comprehensive experiment was conducted with the comparison of a non-hyperaccumulator Cardamine species, Cardamine pratensis , covering growth characteristics, chlorophyll fluorescence, spatial selenium/sulfur distribution patterns through elemental analyses (synchrotron-based X-Ray Fluorescence and ICP-OES) and speciation data through selenium K-edge micro X-ray absorption near-edge structure analysis (μXANES) and strong cation exchange (SCX)-ICP-MS. The results revealed remarkable differences in contrast to other selenium hyperaccumulators as neither Cardamine pecies showed evidence of growth stimulation by selenium. Also, selenite uptake was not inhibited by phosphate for either of the Cardamine species. Sulfate inhibited selenate uptake, but the two Cardamine species did not show any difference in this respect. However, μXRF derived speciation maps and selenium/sulfur uptake characteristics provided results that are similar to other formerly reported hyperaccumulator and non-hyperaccumulator Brassicaceae species. μXANES showed organic selenium, “C-Se-C”, in seedlings of both species and also in mature C. violifolia plants. In contrast, selenate-supplied mature C. pratensis contained approximately half “C-Se-C” and half selenate. SCX-ICP-MS data showed evidence of the lack of selenocystine in any of the Cardamine plant extracts. Thus, C. violifolia shows clear selenium-related physiological and biochemical differences compared to C. pratensis and other selenium hyperaccumulators.

Environmental Sciences & Ecology↗

Identification of Martian Regolith Sulfur Components in Shergottites Using Sulfur K Xanes and Fe/S Ratios

Based on isotopic anomalies in Kr and Sm, Sr-isotopes, S-isotopes, XANES results on S-speciation, Fe/S ratios in sulfide immiscible melts [5], and major element correlations with S determined in impact glasses in EET79001 Lith A & Lith B and Tissint, we have provided very strong evidence for the occurrence of a Martian regolith component in some impact melt glasses in shergottites. Using REE measurements by LA-ICP-MS in shergottite impact glasses, Barrat and co-workers have recently reported conflicting conclusions about the occurrence of Martian regolith components: (a) Positive evidence was reported for a Tissint impact melt, but (b) Negative evidence for impact melt in EET79001 and another impact melt in Tissint. Here, we address some specific issues related to sulfur speciation and their relevance to identifying Martian regolith components in impact glasses in EET79001 and Tissint using sulfur K XANES and Fe/S ratios in sulfide immiscible melts. XANES and FE-SEM measurements in approx. 5 micron size individual sulfur blebs in EET79001 and Tissint glasses are carried out by us using sub-micron size beams, whereas Barrat and coworkers used approx. 90 micron size laser spots for LA- ICP-MS to determine REE abundances in bulk samples of the impact melt glasses. We contend that Martian regolith components in some shergottite impact glasses are present locally, and that studying impact melts in various shergottites can give evidence both for and against regolith components because of sample heterogeneity.

Sutton, S. R.↗

Chelation ion chromatography as an automated, and cost-effective analytical technique for REE determination: method development and applications

Rare earth elements (REEs), as critical minerals, have important uses in modern energy and technologies, yet are vulnerable to potential supply chain disruptions. To establish domestic REE supply chain, efficient REE detection methods for resource characterization and mineral processing will be needed to accelerate innovations for domestic REE recovery. This study developed a rapid, novel, and cost-effective for REE detection method using ion chromatography (IC) for aqueous samples. Various REE-targeted eluent gradients and post-column agent compositions were tested on the chelation ion chromatography (CIC) with UV-vis detector for optimal separation and quantification of REEs within approximately 20 min. The single-channel pump to deliver the post-column solution to UV-vis detector was replaced with a 4-channel gradient pump, to increase operation and maintenance efficiencies. After method optimization, resulting calibration curves for more than ten REEs achieved high coefficients of determination (R2>0.999) and low relatively standard deviations (below 3.24%), demonstrating sub-ppm level detection limits (0.0897 to 0.1149 mg/L). The reliability of the CIC method was validated through comparison with inductively coupled plasma mass spectrometry (ICP-MS), showing strong agreement in REE recovery from certified standards. The impact of metal ions and salts on REE recovery using CIC was also systematically investigated. CIC consistently exhibited reliable performance in the presence of salt solutions such as NaCl and Na₂SO₄ (up to 10,000 mg/L). Our study also found the presence of high concentrations of Al ions (at 10,000 mg/L) significantly influenced REE determination, and elevated concentrations of Ca ions affected the recovery of specific REEs, including La, Ce, and Pr. The CIC method was further tested on REE-containing eluents from solvent extraction tests out of fly ash leachates. REE detection from these real processing fluids were reported to achieve 90% to 100% recovery rate from our IC method, compared to ICP-MS results. This study underscores the potential of CIC as a reliable and efficient alternative for REE determination in complex matrices. It also highlights the importance of minimizing select interfering metal ions in solutions to ensure accurate results. The REE CIC method presents a promising, low-maintenance, salt-tolerant, and cost-effective alternative to traditional analytical methods for REE analysis.

detection of rare earth elements (REE)↗

The impact of gas purity on observed reactivity with NO using inductively coupled plasma tandem mass spectrometry

Interference removal in inductively coupled plasma tandem mass spectrometry (ICP-MS/MS) is strongly dependent on the gas selected for use within the collision/reaction cell. There has been little investigation on the effects that reaction gas impurities may have on the resulting spectra. The reactivity of 60 elements was evaluated using nitric oxide (NO 99.5%) with and without a gas purifier to reduce H 2 O impurities to <100 pptV. Experiments were performed using V, Ce, Tl and Th to investigate the effects of purified NO at various flowrates (0.22–1.49 mL min -1 ). Purified NO was shown to significantly mitigate oxy-hydride interferences, improve total ion sensitivity (notable at high gas flows), and shift product distributions advantageously. The reduction in oxy-hydride species results in a product distribution favoring the major expected products, where signals were shown to increase by an order of magnitude. Reduced background and increased signal for the major expected products provides avenues for improving various analytical applications of ICP-MS/MS.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Using yttrium as an indicator to estimate total rare earth element concentration: a case study of anthracite-associated clays from northeastern Pennsylvania

Abstract This study demonstrated using yttrium (Y) as an indicator to estimate the total rare earth element and Y contents (REY) in coal-associated samples and to facilitate selection of samples with high REY assays in a fast and inexpensive manner. More than 10 anthracite-associated samples were collected from each of three Pennsylvanian sites (sites B, J and C) based on Thorium gamma ray logging suggesting high REY content. Several samples from each site were analyzed by ICP-MS to determine the rare earth distribution patterns and to establish the site-specific linear equations of Y and REY. The Y contents of the remaining samples were measured by a portable X-ray fluorescence analyzer, and the REY values were estimated based on the site-specific linear equation developed earlier. R-squared values above 0.70 were obtained for all the estimation equations from all three sites on both a whole sample basis and an ash basis. Previously, ash content has been widely used as an indicator of high REY content. This may not be applicable for a specific site. Site B in this study is an example where ash contents could not be statistically correlated with REY, so using Y for estimation is more applicable. The demonstrated sample screening process is suitable for samples from sites that share more similar distribution patterns (either MREY or LREY or HREY) as well as for samples from sites that share multiple distribution patterns (LREY/MREY/HREY) depending on the desirable accuracy. The demonstrated process lowers the analytical cost from $70 to 80 dollars per sample to $10–15 per sample while significantly reducing the processing time and acid consumption for ICP digestion. This is particularly true when a relatively large sample size is involved, for example, 100 samples from one site analyzed by ICP-MS/OES.

Yang, Xiaojing↗

In situ liquid SIMS analysis of uranium oxide

Trace analysis of nuclear materials in solid particles collected in the environment or particles in liquid slurry generated in nuclear material manufacturing processes can pinpoint elemental, organic, and isotopic signatures of nuclear fuel cycle activities and processes. Such information can support nuclear safeguards programs by increasing our ability to detect undeclared nuclear materials, routine activities for safeguarding at declared facilities, and illicit activities. However, trace radioactive material analysis in liquids and slurries is challenging using bulk approaches. For example, one drawback of sensitive analysis such as inductively coupled plasma mass spectrometry (ICP-MS) is that sample is consumed or destroyed as a result of the technical approach. We developed a vacuum compatible microfluidic interface to enable surface analysis of liquids and liquid-solid interactions using time-of-flight secondary ion mass spectrometry (ToF-SIMS). In this work, we illustrate initial results of liquid standards containing uranium using in situ liquid SIMS. Specifically a series of diluted uranium standards used for ICPMS analysis were studied and the limit of detection was estimated. Since the liquid SIMS analysis is almost nondestructive, the same sample can be analyzed by other more destructive approaches afterwards or saved for future references. Consequently, multimodal analysis is possible. Our results demonstrate that in situ liquid SIMS can be used as a new approach to analyze radioactive materials in liquid and slurry forms of relevance to the IAEA safeguards missions.

In situ liquid ToF-SIMS, uranium, limit of detecti↗

Crosslinked Polyethyleneimine Gel Polymer Interface to Improve Cycling Stability of RFBs

Redox flow batteries are considered a promising technology for grid energy storage. However, capacity decay caused by crossover of active materials is a universal challenge for many flow battery systems, which are based on various chemistries. In this paper, using the vanadium redox flow battery as an example, we demonstrate a new gel polymer interface (GPI) consisting of crosslinked polyethyleneimine with a large amount of amino and carboxylic acid groups introduced between the positive electrode and the membrane. The GPI functions as a key component to prevent vanadium ions from crossing the membrane, thus supporting stable long-term cycling. Cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) measurements were conducted to investigate the effect of GPI on the electrochemical properties of graphitic carbon electrodes (GCFs) and redox reaction of catholyte. X-ray photoelectron spectroscopy (XPS) and 1 H nuclear magnetic resonance (NMR) spectra demonstrated that the crosslinked GPI is chemically stable for 100 cycles without dissolution of polymers and swelling in the strong acidic electrolytes. Results from inductively coupled plasma mass spectrometry (ICP-MS), Fourier-transform infrared (FTIR) spectroscopy, and energy-dispersive X-ray (EDX) spectroscopy proved that the GPI is effective in maintaining the concentration of vanadium species in their respective half-cells, resulting in improved cycling stability because of it prevents active species from crossing the membrane and stabilizes the oxidation states of active species.

Lim, Hyung-Seok↗

Petrology, Geochemistry, and Pairing of Lunar Meteorites from the Dominion Range

Introduction: During the 2018-2019 Antarctic Search for Meteorites (ANSMET) field season in the Dominion Range (DOM), 7 lunar meteorite stones were collected: DOM 18242 (15.1 g), DOM 18244 (25.1 g), DOM 18262 (6.8 g), DOM 18509 (16.5 g), DOM 18543 (13.6 g), DOM 18666 (45.9 g), and DOM 18678 (11.6 g). Here we present the initial results of electron microprobe and X-ray computed tomography (XCT) studies of these stones and look at the details of their petrography and mineral chemistry, as well as investigate possible pairing relationships, both with each other and with previously described lunar meteorites. Most of the work presented here is on the DOM 18509, 18543, and 18678 stones; subsamples of the other stones are in hand and similar measurements will be made on them by the time of the meeting. Methods: Textures in DOM 18509, DOM 18543, and DOM 18678 were characterized in 2D by optical microscopy, backscattered electron (BSE) imaging and elemental X-ray images on thin sections, as well as in 3D by X-ray computed tomography (XCT) on sample chips. Mineral compositions were assessed through a combination of wavelength dispersive spectroscopy EPMA (electron probe microanalysis) and x-ray mapping on the JEOL 8530 at NASA JSC. The bulk composition of all three meteorites was determined based on analyses of the fusion crust glass. XCT analyses were done on the Nikon XTH 320 at NASA JSC. ICP-MS data on bulk rock subsamples for each meteorite will be carried out in the near future. Results: The stones are all similar in macroscopic appearance with a dark aphanitic matrix hosting a variety of small- to medium-sized angular mineral and lithic fragments (often light colored in nature) [1,2]. Based on EPMA and XCT results, the three meteorites are polymict regolith breccias comprised of mineral, glass, and lithic clasts ranging up to several mm in length. Melt veins run through all three meteorite samples. Mineral clasts in all 3 stones are dominated by pyroxene and plagioclase (An82-96), with minor amounts of SiO2, olivine (Fo1-52), and FeTi-oxides. Pyroxene grains are mostly Fe-rich pigeonite and augite, and larger clasts are normally zoned and have fine exsolution lamellae. The lithic clasts in all stones consists of: (1) basalt clasts that contain zoned pyroxene, plagioclase laths, and ilmenite, with minor silica and Fe-rich olivine; (2) granulitic clasts; (3) anorthosite clasts; (4) Si-rich clasts that also contain ilmenite, troilite, high-Ca pyroxene, fayalite, and K-feldspar likely mesostasis from late stage basalts). All three meteorites contain glassy fusion crust that is highly vesicular, high in FeO and Al2O3 (15-17 wt% each), ferroan (Mg# of 23-24), and moderately rich in TiO2 (1.4-1.8 wt%). The composition of the fusion crust can serve as a proxy for the bulk meteorite composition and is identical within error for all three meteorites. Implications: The lithic and mineral clasts in all three stones are similar in clast population and assemblages as well as mineral chemistry. In addition, the fusion crust composition, a proxy for bulk composition, is within error of each other for all three stones. Thus DOM 18509, DOM 18543, and DOM 18678 are almost certainly paired. Based on similarities in macroscopic description as well as preliminary classification data [1,2], all 7 lunar stones from DOM are likely paired, though additional quantitative analyses are needed to confirm this. The presence of spherules and vesicular fusion crusts indicates that the DOM pairing group is a regolith breccia. The presence of basaltic and gabbroic clasts as well as more feldspathic materials, suggest that the regolith from which these meteorites formed contained a mixture of feldspathic highland material and mare material, suggesting a possible provenance near a marehighlands boundary. No evidence of KREEPy lithologies have been observed so far in these meteorites, however, future ICP-MS data on bulk rock chips for the stones will reveal any KREEP component if present. The DOM pairing group has many similarities to previously described lunar breccia meteorite MET 01210, however more detailed compositional data will be needed to make a definitive comparison.

R.A. Zeigler↗