Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “IBM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Optimization guide for programs compiled under IBM FORTRAN H (OPT=2)

Guidelines are given to provide the programmer with various techniques for optimizing programs when the FORTRAN IV H compiler is used with OPT=2. Subroutines and programs are described in the appendices along with a timing summary of all the examples given in the manual.

Smith, D. M.↗

System design package for IBM system one: solar heating and domestic hot water

This report is a collation of documents and drawings that describe a prototype solar heating and hot water system using air as the collector fluid and a pebble bed for heat storage. The system was designed for installation into a single family dwelling. The description, performance specification, subsystem drawings, verification plan/procedure, and hazard analysis of the system was packaged for evaluation of the system with information sufficient to assemble a similar system.

Source record↗

Solar energy system performance evaluation: Seasonal report for IBM System 2, Togus, Maine

The solar energy system, SIMS Prototype System 2, was designed to supply domestic hot water to single family residences. The system consists of flat plate collectors, silicone working fluid, storage tanks, pumps, heat exchanger, controls, and associated plumbing. The long term field performance of the installed system was analyzed and the results are described.

Source record↗

Solar energy system economic evaluation: IBM System 2, Togus, Maine

The economic analysis of the solar energy system, is developed for Torgus and four other sites typical of a wide range of environmental and economic conditions in the continental United States. This analysis is accomplished based on the technical and economic models in the f-chart design procedure with inputs taken on the characteristics of the installed system and local conditions. The results are expressed in terms of the economic parameters of present worth of system cost over a projected twenty year life, life cycle savings, year of positive savings and year of payback for the optimized solar energy system at each of the analysis sites. The sensitivity of the economic evaluation to uncertainties in constituent system and economic variables is also investigated. Results demonstrate that the solar energy system is economically viable at all of the five sites for which the analysis was conducted.

Source record↗

Solar energy system performance evaluation: Seasonal report for IBM System 1B, Carlsbad, New Mexico

A hot solar heating and hot water system's operational performance from April 1979 through March 1980 is evaluated. The space heating and hot water loads were near expected values for the year. Solar energy provided 43 percent of the space heating and 53 percent of the hot water energy. The system did not meet the total system solar fraction design value of 69 percent because of a combination of higher estimated space heating load than was actually encountered and the apportioning of solar energy between the space heating and the domestic hot water loads. System losses and high building temperatures also contributed to this deviation. Total net savings were 23.072 million BTUs. Most of the energy savings came during the winter months, but hot water savings were sufficient to justify running the system during the summer months.

Source record↗

Solar energy system economic evaluation: IBM System 4, Clinton, Mississippi

An economic analysis of the solar energy system was developed for five sites, typical of a wide range of environmental and economic conditions in the continental United States. The analysis was based on the technical and economic models in the F-chart design procedure, with inputs based on the characteristic of the installed system and local conditions. The results are of the economic parameters of present worth of system cost over a 20 year time span: life cycle savings, year of positive savings and year of payback for the optimized solar energy system at each of the analysis sites. The sensitivity of the economic evaluation to uncertainties in constituent system and economic variables is also investigated.

Source record↗

Solar energy system economic evaluation for IBM System 3, Glendo, Wyoming

This analysis was based on the technical and economic models in f-chart design procedures with inputs based on the characteristics of the parameters of present worth of system cost over a projected twenty year life: life cycle savings, year of positive savings, and year of payback for the optimized solar energy system at each of the analysis sites. The sensitivity of the economic evaluation to uncertainties in constituent system and economic variables was also investigated.

Source record↗

Transferring data oscilloscope to an IBM using an Apple II+

A set of PASCAL programs permitting the use of a laboratory microcomputer to facilitate and control the transfer of data from a digital oscilloscope (used with photomultipliers in experiments on soot formation in hydrocarbon combustion) to a mainframe computer and the subsequent mainframe processing of these data is presented. Advantages of this approach include the possibility of on-line computations, transmission flexibility, automatic transfer and selection, increased capacity and analysis options (such as smoothing, averaging, Fourier transformation, and high-quality plotting), and more rapid availability of results. The hardware and software are briefly characterized, the programs are discussed, and printouts of the listings are provided.

Miller, D. L.↗