Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “High precision control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

An advanced pitch change mechanism incorporating a hybrid traction drive

A design of a propeller pitch control mechanism is described that meets the demanding requirements of a high-power, advanced turboprop. In this application, blade twisting moment torque can be comparable to that of the main reduction gearbox output: precise pitch control, reliability and compactness are all at a premium. A key element in the design is a compact, high-ratio hybrid traction drive which offers low torque ripple and high torsional stiffness. The traction drive couples a high speed electric motor/alternator unit to a ball screw that actuates the blade control links. The technical merits of this arrangement and the performance characteristics of the traction drive are discussed.

Steinetz, B. M.↗

Precision pointing control for an orbital earth observing system

The design concept developed for the pointing system of the high-resolution imaging spectrometer (HIRIS) which will be flown on one of NASA's earth observing system platforms is presented. The instrument is an F/5.4-aperture spectrometer with a focal length of 1222 mm, and it uses a precision two-axis gimballed mirror pointing system to image and track targets. Pointing accuracy of better than 585 arcsec (peak-to-peak), and pointing jitter of less than 2.65 arcsec in 33 ms are ensured through the use of gimbal position and basebody rate sensors. A state-space controller implemented with a digital computer is used to provide a position loop bandwidth of 1 Hz and a rate loop bandwidth of 7 Hz. An overview of the system design and flight hardware is given, the development of the controller architecture is addressed, and a simulation assessment of the pointing system that takes into consideration issues such as nonlinear effects, sensor noise, and noncollocated sensors and actuators in a flexible structure is discussed.

Robeck, Linda S.↗

Dual clearance squeeze film damper for high load conditions

Squeeze film dampers are widely used to control vibrations in aircraft turbine engines and other rotating machinery. However, if shaft unbalance rises appreciably above the design value (e.g., due to a turbine blade loss), a conventional squeeze film becomes overloaded, and is no longer effective in controlling vibration amplitudes and bearing forces. A damper concept characterized by two oil films is described. Under normal conditions, only one low-clearance film is active, allowing precise location of the shaft centerline. Under high unbalance conditions, both films are active, controlling shaft vibration in a near-optimum manner, and allowing continued operation until a safe shutdown can be made.

Fleming, D. P.↗

Dual clearance squeeze film damper for high load conditions

Squeeze film dampers are widely used to control vibrations in aircraft turbine engines and other rotating machinery. However, if shaft unbalance rises appreciably above the design value (e.g., due to a turbine blade loss), a conventional squeeze film becomes overloaded, and is no longer effective in controlling vibration amplitudes and bearing forces. A damper concept characterized by two oil films is described. Under normal conditions, only one low-clearance film is active, allowing precise location of the shaft centerline. Under high unbalance conditions, both films are active, controlling shaft vibration in a near-optimum manner, and allowing continued operation until a safe shutdown can be made.

Fleming, D. P.↗

Controlling Shape And Vibration Of Antennas

Report discusses application of advanced techniques to maintain large wrap-rib, offset-feed spaceborne antenna reflector in precise shape required for high performance. Idea is to use integrated system of sensors, control processor, and actuators to measure and suppress both vibrations and static or slowly varying (e.g., thermal) deviations from desired shape. Technology applicable to other elastically deformable structures.

Mettler, E.↗

Damping and structural control of the JPL phase 0 testbed structure

This paper describes recent advances in structural quieting technology as applied to active truss structures intended for high precision space based optics applications. The active structure incorporates piezoelectric active members which exert control forces internal to the structure and thereby improve the structure's dimensional stability. The control architecture involves two layers of feedback control. The first utilizes collocated measurements of force and velocity at the active member to achieve active damping, the second utilizes noncollocated measurements of acceleration at the location of a simulated optical component to achieve structural stabilization. The local control loops are based on the concept of impedance matching, the global control loops are designed using robust control methods. These two levels of control are intended to operate simultaneously; however, in this paper each approach is applied individually. The combined implementation is left for future work.

Fanson, James L.↗

Evolution of the Lunar Receiving Laboratory to the Astromaterial Sample Curation Facility: Technical Tensions Between Containment and Cleanliness, Between Particulate and Organic Cleanliness

The Lunar Receiving Laboratory (LRL) was planned and constructed in the 1960s to support the Apollo program in the context of landing on the Moon and safely returning humans. The enduring science return from that effort is a result of careful curation of planetary materials. Technical decisions for the first facility included sample handling environment (vacuum vs inert gas), and instruments for making basic sample assessment, but the most difficult decision, and most visible, was stringent biosafety vs ultra-clean sample handling. Biosafety required handling of samples in negative pressure gloveboxes and rooms for containment and use of sterilizing protocols and animal/plant models for hazard assessment. Ultra-clean sample handling worked best in positive pressure nitrogen environment gloveboxes in positive pressure rooms, using cleanable tools of tightly controlled composition. The requirements for these two objectives were so different, that the solution was to design and build a new facility for specific purpose of preserving the scientific integrity of the samples. The resulting Lunar Curatorial Facility was designed and constructed, from 1972-1979, with advice and oversight by a very active committee comprised of lunar sample scientists. The high precision analyses required for planetary science are enabled by stringent contamination control of trace elements in the materials and protocols of construction (e.g., trace element screening for paint and flooring materials) and the equipment used in sample handling and storage. As other astromaterials, especially small particles and atoms, were added to the collections curated, the technical tension between particulate cleanliness and organic cleanliness was addressed in more detail. Techniques for minimizing particulate contamination in sample handling environments use high efficiency air filtering techniques typically requiring organic sealants which offgas. Protocols for reducing adventitious carbon on sample handling surfaces often generate particles. Further work is needed to achieve both minimal particulate and adventitious carbon contamination. This paper will discuss these facility topics and others in the historical context of nearly 50 years' curation experience for lunar rocks and regolith, meteorites, cosmic dust, comet particles, solar wind atoms, and asteroid particles at Johnson Space Center.

Allton, J. H.↗

Electronic Control Of Slow Rotations

Digital/analog circuit controls both angular position and speed of rotation of motor shaft with high precision. Locks angular position of motor to phase of rotation-command clock signal at binary submultiple of master clock signal. Circuit or modified version used to control precisely position and velocity of robotic manipulator, to control translation mechanism of crystal-growing furnace, to position hands of mechanical clock, or to control angular position and rate of rotation in any of large variety of rotating mechanisms.

Howard, David E.↗

NASA's Precision Segmented Reflectors (PSR) project

The PSR project representing a step toward developing the technology base needed to support future advanced astrophysics missions is described. The project is focused on producing high precision lightweight panels, large structures with proven erectability and accuracy, and lightweight and low power controls capable of achieving a high degree control of accuracy. Panels of sizes from 0.4 to 0.9 meter are fabricated to verify various design concepts for improving panel surface accuracy; in particular, a 0.4 meter panel is fabricated and refinished to a high degree of accuracy.

Pawlik, E.↗

High speed, precision motion strategies for lightweight structures

Research on space telerobotics is summarized. Adaptive control experiments on the Robotic Arm, Large and Flexible (RALF) were preformed and are documented, along with a joint controller design for the Small Articulated Manipulator (SAM), which is mounted on the RALF. A control algorithm is described as a robust decentralized adaptive control based on a bounded uncertainty approach. Dynamic interactions between SAM and RALF are examined. Unstability of the manipulator is studied from the perspective that the inertial forces generated could actually be used to more rapidly damp out the flexible manipulator's vibration. Currently being studied is the modeling of the constrained dynamics of flexible arms.

Book, Wayne J.↗

Trends in high-speed atmospheric flight

Some of the current problems and future trends for three types of flight within the Earth's atmosphere are considered. The three areas examined are atmosphere entry at very high speeds, atmosphere exit of launch vehicles, and sustained cruise within the atmosphere. The high-speed entry problems described are those encountered by vehicles returning to Earth after a manned mission to Mars. Such vehicles will experience atmosphere entry speeds up to 50,000 and perhaps as high as 70,000 feet per second. For these vehicles to execute a successful entry, accurate guidance at Earth approach must be provided and very precise control during the flight within the atmosphere will be a necessity. At the high entry speeds radiative heating-is greater than convective and thus it tends to exert a dominant influence on entry-vehicle configuration. The study and development of relatively slender vehicles is indicated in order to minimize the large radiative heating loads and associated heat-shield weights. Manned interplanetary missions in the future may also involve a need for very large launch vehicles. These large vehicles will have aerodynamic problems which differ somewhat from current problems. For example, drag losses decrease with increasing size and large vehicles may thus be of lower fineness ratio than present-day vehicles. With lower fineness ratio some of the difficult current problems produced by ground-wind loads and by buffet of hammerhead payload mountings will be avoided. In the case of high-speed cruise within the Earth's atmosphere, the use of hydrogen-fueled, airbreathing engines may permit attractive payload capabilities for long-range high-speed transports. For such vehicles aerodynamic problems arise because of the numerous constraints placed upon their flight paths as well as from the large volumes required for the hydrogen fuel. From payload considerations alone, attractive cruise speeds for such vehicles currently appear to be about twice that of the conventionally fueled supersonic transports now being intensively studied.

Atmospheric entry↗

A New Clinical Instrument for The Early Detection of Cataract Using Dynamic Light Scattering and Corneal Topography

A growing cataract can be detected at the molecular level using the technique of dynamic light scattering (DLS). However, the success of this method in clinical use depends upon the precise control of the scattering volume inside a patient's eye and especially during patient's repeat visits. This is important because the scattering volume (cross-over region between the scattered fight and incident light) inside the eye in a high-quality DLS set-up is very small (few microns in dimension). This precise control holds the key for success in the longitudinal studies of cataract and during anti-cataract drug screening. We have circumvented these problems by fabricating a new DLS fiber optic probe with a working distance of 40 mm and by mounting it inside a cone of a corneal analyzer. This analyzer is frequently used in mapping the corneal topography during PRK (photorefractive keratectomy) and LASIK (laser in situ keratomileusis) procedures in shaping of the cornea to correct myopia. This new instrument and some preliminary clinical tests on one of us (RRA) showing the data reproducibility are described.

Ansari, Rafat R.↗

High accuracy motor controller for positioning optical filters in the CLAES Spectrometer

The Etalon Drive Motor (EDM), a precision etalon control system designed for accurate positioning of etalon filters in the IR spectrometer of the Cryogenic Limb Array Etalon Spectrometer (CLAES) experiment is described. The EDM includes a brushless dc torque motor, which has an infinite resolution for setting an etalon filter to any desired angle, a four-filter etalon wheel, and an electromechanical resolver for angle information. An 18-bit control loop provides high accuracy, resolution, and stability. Dynamic computer interaction allows the user to optimize the step response. A block diagram of the motor controller is presented along with a schematic of the digital/analog converter circuit.

Thatcher, John B.↗

Space Suit Portable Life Support System Thermal Control Valve Ball Design

A Thermal Control Valve (TCV) has been in development for the Exploration Extravehicular Mobility Unit Portable Life Support System (xEMU PLSS). The xEMU PLSS TCV controls flow going to the liquid cooling and ventilation garment that the crew member wears during extra-vehicular activity to expel waste heat. A previous TCV version with a linear actuator and diverter valve has been tested to attempt to control the flow accurately. The previous valve has a non-linear flow response relative to valve position and has struggled to meet the setpoints desired for precise thermal control. While many diverter valve design variations have been attempted, all previous designs have had difficulty meeting set points. Additionally, high precision machining is required to create a metal-on-metal seal which has its own drawbacks and does not always meet requirements for internal leakage. This metal seal also requires stalling a linear actuator to load the seal in compression or tension which has caused sticking failures when stalled. A new approach and design for a TCV has been developed which uses a rotational ball to control flow and has demonstrated a much more precise and linear flow control. The design functions like a two-way ball valve with two Teflon seats that cradle and compress the ball for sealing. The ball outlet has a unique geometric design to create a set-able orifice like hole which is more predictable at controlling flow. Additionally, the Teflon seat performs much better for preventing internal leakage than the metal seal and prevents sticking by having a large range in which it is sealed without having to stall the actuator. This paper will review a new proposed xEMU PLSS TCV ball design and compare it with previous iterations of the design.

Ryan Ogilvie↗

Space Suit Portable Life Support System Thermal Control Valve Ball Design

A Thermal Control Valve (TCV) has been in development for the Exploration Extravehicular Mobility Unit Portable Life Support System (xEMU PLSS). The xEMU PLSS TCV controls flow going to the liquid cooling and ventilation garment that the crew member wears during extra-vehicular activity to expel waste heat. A previous TCV version with a linear actuator and diverter valve has been tested to attempt to control the flow accurately. The previous valve has a non-linear flow response relative to valve position and has struggled to meet the setpoints desired for precise thermal control. While many diverter valve design variations have been attempted, all previous designs have had difficulty meeting set points. Additionally, high precision machining is required to create a metal-on-metal seal which has its own drawbacks and does not always meet requirements for internal leakage. This metal seal also requires stalling a linear actuator to load the seal in compression or tension which has caused sticking failures when stalled. A new approach and design for a TCV has been developed which uses a rotational ball to control flow and has demonstrated a much more precise and linear flow control. The design functions like a two-way ball valve with two Teflon seats that cradle and compress the ball for sealing. The ball outlet has a unique geometric design to create a set-able orifice like hole which is more predictable at controlling flow. Additionally, the Teflon seat performs much better for preventing internal leakage than the metal seal and prevents sticking by having a large range in which it is sealed without having to stall the actuator. This paper will review a new proposed xEMU PLSS TCV ball design and compare it with previous iterations of the design.

Ryan Ogilvie↗

On-orbit control system performance of the HEAO-2 observatory

The on-orbit performance of the High Energy Astronomy Observatory is described. The control system utilizes precision gyros for attitude reference and skewed reaction wheels controlled by a reprogrammable computer. The observatory points at selected targets, maneuvers automatically and acquires guide stars for updating at each target. Performance data indicates maneuver accuracies less than one arc minute and pointing accuracies of 2-5 arc seconds. Use of 7th-9th magnitude guide stars has resulted in several improper updates caused by 'flat-field' stray light effects in the star trackers. The method used to discriminate true stars from the flat-field is also presented.

Rose, R. E.↗