Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Heat transfer performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Development of a Light-Trapping, Planar-Cavity Receiver for Enclosed Solar Particle Heating

Concentrating solar thermal power (CSP) technology development has recently focused on high efficiency power cycles and chemical reactions that require high operating temperatures. An increase in receiver operating temperatures relative to current commercial CSP technology is necessary to support more efficient, high temperature power cycles or thermochemical processes. Solar receivers operating with heat transfer media temperatures >700 degrees C face various challenges including thermal performance, scalability, thermal-mechanical issues, and receiver service life. In addition, heat transfer media selection for high-temperature processes has been moving towards inert solid particles in Gen3 CSP, and reactive solid media and/or gases in solar thermochemical processes. To overcome the shortcomings and limitations of conventional designs for molten salt or particle receivers and receiver reactors, we introduce a unique light-trapping, planar cavity receiver (LTPCR) configuration and will present the current development progresses to demonstrate receiver feasibility through modeling, testing, and prototype demonstration.

ENGINEERING,SOLAR ENERGY↗

Effects of Downstream Vortex Generators on Film Cooling a Flat Plate Fed by Crossflow

Counter-rotating vortices, formed by the interaction of film-cooling jets and the hot gas flow, adversely affect the performance of conventional film-cooling designs. Downstream vortex generators have been shown to improve cooling effectiveness by mitigating the effects of the counter-rotating vortices and by deflecting the cooling jet laterally. In this study, computational and experimental methods were used to examine how cylindrical film-cooling holes (D = 3.2 mm, L/D = 6, p/D = 3, α = 30 deg) with and without downstream vortex generators perform when the coolant supply channel is perpendicular to the direction of the hot gas. For this study, the hot gas had a temperature of 650 K and an average Mach number of 0.23. Here, the hot-gas-to-coolant temperature ratio was 1.9, and two blowing ratios (0.75 and 1.0) were studied. Results from the computational fluid dynamics study show how crossflow affects the interaction between the film-cooling jet and hot gas flow with and without downstream vortex generators. The experimental measurements were based on infrared thermography in a conjugate heat transfer environment. Results were obtained for film-cooling performance in terms of overall effectiveness, film effectiveness, and local heat transfer coefficients. The downstream vortex generators can increase the laterally averaged effectiveness by a factor of 1.5 relative to cylindrical holes, but this higher performance is restricted to low crossflow velocities and higher blowing ratios.

17 WIND ENERGY↗

Advanced Multi-Tube Mixer Combustion for 65% Efficiency (Final Report)

This project targeted advanced low NOx combustion for advanced gas turbines capable of 65%, or greater, efficiency in combined cycle application. This technology advancement has further potential to benefit gas turbines used in coal based IGCC applications with pre-combustion carbon capture and hydrogen as the resulting fuel. The program developed and synthesized the most advanced combustion system capable of achieving low NOX emissions up to turbine inlet temperatures of 3100F while also supporting the load-following needs of a modern grid. The combustion system contributes to the overall gas turbine efficiency goal by setting the maximum cycle temperature achievable for a given NOX level and by minimizing the through-combustor air flow pressure drop. Focus areas for this project targeted maximizing the turbine inlet temperature entitlement, as constrained by emissions considerations. The design also minimized parasitic air flow pressure drop by using advanced cooling techniques and performance materials selections and by minimizing hot surface area. These two technology objectives (maximum, emissions-compliant cycle temperature and minimum air flow pressure drop) were integrated into a prototype design. The primarily analytical project sought to identify the most promising technologies to meet these objectives. Additional critical “jugular” data were obtained from multi-tube mixer tests to realize the potential of leveraging “micro flames” for minimizing overall hot surface area. This data was used, in conjunction with an understanding of advanced material and cooling design technologies, to analytically develop multiple design concepts. Phase I focused on in-depth engineering analysis and design, with minimal supporting laboratory testing to enable a selection of the top three combustion architectures for achieving these overall objectives. Phase II of the program developed the selected design through a combination of sub-scale testing and analytical efforts. Early tests included a cold-flow cascade to establish aerodynamic performance characteristics and a sub-scale fired test at GE Global Research in Niskayuna, NY, to establish cooling and heat transfer characteristics in conjunction with combustion performance. The data from these tests validated the analytical models to ultimately design a full-scale, test article to evaluate at prototypical pressure and temperature conditions at GE Gas Power’s Gas Turbine Technology Laboratory in Greenville, SC. GE Gas Power also developed, tested, and recommended a suitable seal design to be applied to the unique features of the combustor. To assess the technology challenges from prospective future production of the combustor from a ceramic matrix composite material, screening tests of Environmental Barrier Coatings were completed.

20 FOSSIL-FUELED POWER PLANTS↗

Thermodynamic Modeling of Heat Engines Including Heat Transfer and Compression–Expansion Irreversibilities

In this paper, a thermodynamic model based on an endoreversible engine approach is developed to analyze the performance of heat engines operating under different thermodynamic cycles. The model considers finite heat transfer rate, variable heat source and sink temperatures, and irreversibilities associated with the expansion and compression. Expressions for the maximum power and efficiency at maximum power output are obtained as a function of hot and cold reservoir temperatures, the equivalent isentropic efficiency of compression and expansion components, and the effective conductance ratio between heat exchangers. In all cases, the Curzon–Ahlborn efficiency is retrieved at constant reservoir temperatures and neglected compression–expansion irreversibilities. The proposed model allows assessing the effect of isentropic efficiencies and heat exchanger design and operation characteristics for different thermodynamic cycles.

33 ADVANCED PROPULSION SYSTEMS↗

Advanced Serpentine Heat Exchangers to Minimize Number of Joints and Leakage in HVAC&R Systems

Refrigerant leakage has a significant impact on heating, ventilation, air conditioning and refrigeration (HVAC&R) industries in terms of both greenhouse gas (GHG) emissions and lost efficiency of the systems themselves. One of the major causes of refrigerant leakage is braze joints within a vapor compression system. The brazing process is often inconsistent and almost always imperfect. As a result, braze joints are left vulnerable to leaks and can be weaker than non-brazed tubing. Conventional tube-fin heat exchangers are manufactured using one brazed joint per tube. An alternative to the conventional approach is the use of a single continuous serpentine tube. An Advanced Serpentine Heat Exchanger was developed to provide a heat transfer solution that meets or exceeds performance while also significantly reducing the number of joints and, consequently, the potential for refrigerant leakage. The developed serpentine heat exchanger not only delivers on performance, but is also cost competitive with conventional heat exchangers on the market.

30 DIRECT ENERGY CONVERSION↗

Development of Numerical Model of Metal Foam with PCM for the Estimation of Effective Thermal Conductivity

Global warming due to climate change is a threat to humankind. Nuclear energy is one of the promising solutions to reduce fossil fuel usage. Nuclear energy can handle the base load, compensating for the volatility of renewable energy. If nuclear energy could achieve load following capability, the combination with renewable energy would be more suitable. Thermal energy storage (TES) is one of the options for enabling load following of nuclear reactors. The TES makes it possible to store surplus nuclear thermal energy and release it later as needed. In Idaho National Laboratory (INL), a new concept of latent heat TES integrated with high-temperature heat pipe has been proposed and is under development, which is called Heat pipe-Integrated Thermal Battery (HITB). HITB exchanges thermal energy between the reactor system and TES via heat pipe. The heat transferred to TES medium, made of phase change material (PCM), stores energy as sensible heat and/or latent heat. As PCM typically has poor thermal conductivity, however, various heat transfer enhancement techniques are required to achieve a rapid charging cycle. There are many techniques to enhance the heat transfer ability of TES medium such as disk, fin, and metal foam. Among them, metal foam is an appropriate option to enhance the heat transfer because it maximizes the heat transfer area through metal wicks. Metal foam is a lightweight metal structure that has a high porosity of over 0.9. The typical materials for metal foam are Aluminum, Copper, Nickel, and Silicon Carbide (SiC). Metal foam not only enhances heat transfer via conduction but also increases contact surface area. In the HITB design , the metal foam is being considered as one of the options to enhance the heat transfer of TES medium (PCM) [1]. To predict the enhanced thermal performance of TES, one should properly estimate the effective thermal conductivity of metal foam combined with PCM material or calculate heat transfer in distributed model. There are many experimental works that provides effective thermal conductivity of metal foam with various PCM [2,3]. Also, many theoretical models were developed based on the unit cell model of metal foam [4,5]. With a distributed model, on the other hand, detail heat transfer characteristics between metal foam and PCM material can be analyzed considering the geometry or buoyancy effect. However, due to the complex geometry of metal foam pores, the computational cost for three-dimensional modeling highly increases. Therefore, if metal foam structure can be modeled in simple and repetitive design, the computational cost would decrease Among the various metal foam models [2], lattice model is one of the simple and extendable design. The porosity and pores per inch (PPI) can be characterized by the size and spatial distance of lattice structure. If the three-dimensional metal foam model consists of lattice structure could properly estimate the heat transfer, which is characterized by effective thermal conductivity, it would be a good option to assess the thermal performance of metal foam with PCM. In this study, a three-dimensional numerical model was developed to simulate conductive heat transfer between metal foam and PCM. The three-dimensional lattice structure of square pillars was selected as a basic structure of the metal foam. The calculation result was characterized by the effective thermal conductivity of the whole domain. A sensitivity study was conducted for mesh size, domain size, and PPI to check whether the calculation result gives a converged result or not. Lastly, the effective thermal conductivity from the lattice model was compared with existing experimental data to validate the model result

25 ENERGY STORAGE↗

Thermal Management System for an Electric Machine with Additively Manufactured Hollow Conductors with Integrated Heat Pipes: Preprint

This paper discusses steps taken to size a thermal management system for an aircraft propulsion electric machine containing additively manufactured coils integrated with heat pipes aimed at boosting its specific power. Experimental setups are used to size and characterize heat pipes for the application and 3D thermal FEA is used to determine optimum heat transfer coefficient of convective boundaries. Geometric details of fin-based surface area enhancement required to reach target combined overall heat transfer coefficient (U) and surface area (A) performance (UA) in W/K, is worked out for relevant boundaries and the resulting UA is verified in 3D thermal FEA. Thermal management system's UA (by extension specific power) sensitivity to coolant temperature is explored and temperature distribution plots of optimized machine components are presented and discussed.

additive manufacturing↗

Solid-to-Fluid Radiative Heat Transfer Modeling for System Analysis Module

System Analysis Module (SAM) is a system-level thermal hydraulics code being developed at Argonne National Laboratory for advanced nuclear reactor analysis. In addition to a wide range of interests from the advanced reactor design community, SAM has also been adopted by the United States Nuclear Regulatory Commission's suite of codes purposed for advanced reactor licensing. Nevertheless, the code is still under active development and new capabilities are being added to address various modeling and simulation challenges for advanced reactor analysis. One such phenomenon important to the thermal behavior of some advanced reactor concepts is radiative heat transfer (radHT). Conditions, such as high temperatures and long optical paths, increase the radiative contributions from solids and coolants alike. This paper discusses the development of radHT modeling in SAM and describes the new capabilities provided for thermal analysis. Depending on the geometry and temperatures of the system at hand, as well as the coolant in question, thermal transfer due to thermal radiation will vary dramatically. Therefore, the ability to model variable radiative systems was maintained as a priority during development of SAM radHT modeling. This newly developed simulation feature provides a flexible solid-to-fluid radiative heat transfer framework necessary for SAM to perform accurate analysis for advanced reactor designs. Test cases are also presented and shown to match analytical solutions, which demonstrate the radHT model's efficacy.

Radiative heat transfer↗

Physics-based hybrid machine learning for critical heat flux prediction with uncertainty quantification

Critical heat flux (CHF) is a key quantity in nuclear system modeling due to its impact on heat transfer, safety margins, and reactor performance. This study develops and validates an uncertainty-aware hybrid modeling approach that combines machine learning with physics-based models to predict CHF in cases of dryout. The Biasi and Bowring empirical correlations were paired with three ML uncertainty quantification (UQ) techniques: deep neural network (DNN) ensembles, Bayesian neural networks (BNNs), and deep Gaussian processes (DGPs). A pure ML model without a base model was evaluated for comparison. Model performance was assessed under plentiful (7,350 points) and limited (9 points) training data scenarios using parity, uncertainty distributions, and calibration curves. Results show that the Biasi hybrid DNN ensemble achieved the best overall performance, with a mean absolute relative error of 1.846%, and well-calibrated uncertainty estimates. The BNN-based hybrids showed slightly higher error (2.14%) but superior uncertainty calibration. DGP models underperformed, with over 6% error and poor uncertainty calibration. All hybrid models outperformed pure machine learning configurations, demonstrating resistance against data scarcity. These findings indicate that hybrid modeling significantly improves predictive accuracy, interpretability, and resilience to data scarcity. The integration of uncertainty awareness provides actionable confidence in CHF predictions, which is vital for safety-critical decisions in nuclear applications. This hybrid approach offers a viable pathway for deploying ML models in reactor analysis tools while preserving domain knowledge and physical consistency.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

High-Performance Thermoelectric Generators for Field Deployments

Thermoelectric power generation is a reliable energy harvesting technique for directly converting heat into electricity. Recent studies have reported the thermal-to-electrical energy conversion efficiency of thermoelectric generators (TEGs) up to 11% under laboratory settings. However, the practical effectiveness of TEGs deployed under real environments is still not more than a few percent. In this study, we provide fundamental insight on the operation of TEGs in realistic environments by illustrating the combinatory effect of thermoelectric material properties, device boundary conditions, and environmental thermal resistivity on TEG performance in conjunction with the module parameters. Using numerical and experimental studies, we demonstrate the existence of a critical heat transfer coefficient that dramatically affects the design and performance of TEGs. Results provide a set of concrete design criteria for developing efficient TEGs that meet the metrics for field deployments. High-performance TEGs demonstrated in this study generated up to 28% higher power and 162% higher power per unit mass of thermoelectric materials as compared to the commercial module deployed for low-grade waste heat recovery. This advancement in understanding the TEG operation will have a transformative impact on the development of scalable thermal energy harvesters and in realizing their practical targets for efficiency, power density, and total output power.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Design and experimental testing of a 150 kWh thermal battery using thermosiphons embedded in a concrete matrix for power plant flexible operation

One of the options for achieving the global temperature limitation of 1.5 °C target, for the mitigation of global warming, is based on the better penetration of renewables into the electrical grid. This has imposed a burden to fossil fuel fired power plants since they are required to operate away from their baseload mode to compensate for the inherent intermittence of the renewable power. Integrating energy storage with fossil plants is an option to achieve their needed flexibility. A cost competitive energy storage option for the solution is based on storing sensible heat in concrete. Here, this paper reports research results and development of a thermal battery cell (TBC) capable of operating at temperatures up to 425 °C. A novel concept consisting of a concrete matrix for sensible heat storage, engineered to provide enhanced thermal and mechanical properties, and twenty-two thermosiphon elements, engineered for dual action were designed and fabricated into a single thermal energy storage (TES) module. Research for the development of the components for the TBC was performed in the laboratory. Efficient heat transfer, to/from the storage media, was demonstrated under several charging and discharging conditions with a thermal storage capacity of 150 kWh th and a rapid discharge, making the TBC suitable for fast ramping when integrated with a fossil fuel fired power plant. Efficient radial heat transfer to the concrete was observed due to the well designed spacing and location of thermosiphons in the radial direction. A minimal temperature difference of 2 °C, between the thermosiphons bottom and top was obtained, demonstrating the isothermicity of those elements. An overall end-to-end TBC energy-to-energy round trip efficiency of 70% was achieved.

25 ENERGY STORAGE↗

Multi-physics Modeling of Radiative Heat Transfer and Fluid Flow for the Reactor Cavity Cooling System

High-temperature gas-cooled reactors (HTGRs) are notable for their high thermal efficiency and potential for combined heat and power applications. These reactors are particularly appealing due to their advanced passive safety features. HTGRs utilize passive safety systems that function without requiring active components like pumps or compressors during emergencies. These reactor designs depend on a Reactor Cavity Cooling System (RCCS) to manage decay heat removal from the reactor pressure vessel (RPV) during accident conditions. The RCCS consists of vertical rectangular channels known as "risers" or riser ducts positioned around the RPV. These risers receive heat from the RPV through both convective and radiative heat transfer mechanisms. Understanding the interplay of multiple physical phenomena, such as fluid dynamics, heat transfer, and neutron interactions, is essential for the effective design and operation of nuclear reactors, particularly for systems like the RCCS. Multi-physics simulations provide a comprehensive approach to studying these interactions, offering detailed insights and enhancing accuracy. They are especially important in RCCS designs, where the interaction between radiative and convective heat transfer can significantly impact system performance. By leveraging multi-physics simulations, complex reactor behaviors can be modeled without compromising the fidelity of the underlying physical processes. This work aims to establish a robust methodology for coupling multiple physical processes in an air-cooled RCCS. By focusing on validating this multi-physics approach, the study involves designing test cases that simulate various conditions to verify the numerical models employed. The outcomes of this research will provide critical insights for accurately modeling and optimizing complex nuclear systems like the RCCS.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Large Eddy Simulation of Convective Heat Transfer in a Random Pebble Bed Using the Spectral Element Method

The development of fluoride-cooled high-temperature reactors has drastically increased the demand for an in-depth understanding of the heat transfer (HT) in packed beds cooled by liquid salts. The complex flow fields and space-dependent porosity found in a pebble bed require a detailed understanding to ensure the proper cooling of the reactor core during normal and accident conditions. As detailed experimental data are complicated to obtain for these configurations, high-fidelity simulation such as large eddy simulation and direct numerical simulation (DNS) can be employed to create a high-resolution heat transfer numerical database that can assist in addressing industrial-driven issues associated with the heat transfer behavior of fluoride-cooled high-temperature reactors. In this paper, we performed a series of large eddy simulation using computational fluid dynamics (CFD) code NekRS to investigate the heat transfer for a bed of 1741 pebbles. Further, the characteristics of the flow, such as average, rms, and time series of velocity and temperature, have been analyzed. Porous media averages have also been performed. The simulation results show a good agreement between non-conjugate heat transfer and conjugate heat transfer. The generated data will be used to benchmark heat transfer modeling methods and local maxima/minima of heat transfer parameters. It will also be used for supporting convective heat transfer quantification for Kairos Power and benchmarking lower fidelity models.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

3D CFD Model Validation Using Benchmark Data of 1/16th Scaled VHTR Upper Plenum and Development of Wall Heat-Transfer Correlation For Laminar Flow

With support from the U.S. Department of Energy-Office of Nuclear Energy’s (DOE-NE’s) Nuclear Energy Advanced Modeling and Simulation (NEAMS) program, an effort has been pursued to support high-temperature gas-cooled reactor (HTGR) technology development and its modeling and simulation needs. There is a particular need for advanced modeling and simulation tools to predict thermal-fluid behavior in the nuclear reactor primary system, especially in the core and the lower and upper plena, during safety-related transients. In this report, two main such activities are presented relevant to the HTGRs: (1) three-dimensional (3D) computational fluid dynamics (CFD) validation using benchmark data from the upper plenum of Texas A&M University’s 1/16th scaled very-high-temperature gas-cooled reactor (VHTR), and (2) development of wall heat-transfer correlation for laminar flow in a wall-heated pipe. The CFD tool validation exercises can be helpful to choose the models and CFD tools to simulate and design specific components of the HTRGs such as upper plenum where jet mixing is a complex phenomenon. In a loss of forced circulation event, the laminar flow can be observed during the development of natural circulation flow. This work includes the development and validation of heat transfer correlations for laminar flow using the Nek5000 CFD code due to limited available experimental data for laminar flow conditions to guide low-order models (1D). In this report, the flow characteristics of a single isothermal jet discharging into the upper plenum was investigated using the Nek5000 Large-Eddy Simulation (LES) CFD tool. Several numerical simulations were performed for various jet-discharged Reynolds numbers ranging from 3,413 to 12,819. A grid-independent study was performed. The numerical results of mean velocity, root-mean-square fluctuating velocity, and Reynolds stress were compared against the benchmark data. Good agreement was obtained between simulated and measured data for axial mean velocities, except near the upper plenum hemisphere. The maximum predicted errors for axial mean velocities at various normalized coolant channel diameter heights of 1, 5, and 10 are 1.56%, 1.88%, and 3.82%, respectively. In addition, the predicted root-mean-square fluctuating velocity and Reynolds stress are qualitatively in agreement with the experimental data. The Nek5000 code was used to develop wall-heat transfer correlation for laminar flow in a cylindrical tube. Several simulations were performed for various Reynolds flow and wall-heat fluxes. A new heat transfer correlation was developed using data from Nek5000 simulation results and regression functions in Matlab. The developed heat transfer correlation is valid for various Reynolds flows from 200 to 2000. The predicted R² value for model fit was 0.875, which ensures that 87.5% of the model data lies on the Nek5000 data. Moreover, a machine learning (ML) tool was used to train and test the Nek5000 data. A good fit of the ML-based model was observed with the test data.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

High-Temperature Particle Heat Exchanger for sCO2 Power Cycles [Award 30342]

This report describes the design, development, and testing of a prototype 100 kWt particle-to-supercritical CO 2 (sCO2) heat exchanger. An analytic hierarchy process was implemented to compare and evaluate alternative heat-exchanger designs (fluidized bed, shell-and-plate moving packed bed, and shell-and-tube moving packed bed) that could meet the high pressure (≥ 20 MPa) and high temperature (≥ 700 °C) operational requirements associated with sCO2 power cycles. Cost, heat-transfer coefficient, structural reliability, manufacturability, parasitics and heat losses, scalability, compatibility, erosion and corrosion, transient operation, and inspection ease were considered in the evaluation. A 100 kWt shell-and-plate design was selected for construction and integration with Sandia’s falling particle receiver system that heats the particles using concentrated sunlight. Sandia worked with industry to design and construct the moving packed-bed shell-and-plate heat exchanger. Tests were performed to evaluate its performance using both electrical heating and concentrated sunlight to heat the particles. Overall heat transfer coefficients at off-design conditions (reduced operating temperatures and only three stainless steel banks in the counter-crossflow heat exchanger) were measured to be approximately ~25 - 70 W/m 2 -K, significantly lower than simulated values of >100 W/m 2 -K. Tests using the falling particle receiver to heat the particles with concentrated sunlight yielded overall heat transfer coefficients of ~35 – 80 W/m 2 -K with four banks (including a nickel-alloy bank above the three stainless steel banks). The overall heat transfer coefficient was observed to decrease with increasing particle inlet temperatures, which contrasted the results of simulations that showed an increase in heat transfer coefficient with temperature due to increased effective particle-bed thermal conductivity from radiation. The likely cause of the discrepancy was particle-flow maldistributions and funnel flow within the heat exchanger caused by internal ledges and cross-bracing, which could have been exacerbated by increased particle-wall friction at higher temperatures. Additional heat loss at higher temperatures may also contribute to a lower overall heat-transfer coefficient. Design challenges including pressure drop, particle and sCO2 flow maldistribution, and reduced heat transfer coefficient are discussed with approaches for mitigation in future designs. Lessons learned regarding instrumentation, performance characterization, and operation of particle components and sCO2 flow loops are also discussed. Finally, a 200 MWt commercial-scale shell-and-plate heat-exchanger design based on the concepts investigated in this report is proposed.

14 SOLAR ENERGY↗

Transport Analysis & Optimization in a MW-Scale CO2 Electrolyzer (Final Report)

As Twelve continues to scale up their CO2 electrolyzers, both in the size of a single cell and in the number of cells used in a stack, thermal management becomes a growing concern, since excess heat can affect reaction yield and accelerate degradation. In this project, we aim to computationally explore how the anode flow fields used in Twelve’s CO2 electrolyzers function as heat exchangers. In particular, using a homogenized model of a CO2 electrolyzer, we first estimate the amount of heat generated in a cell. Then, we develop a computational fluid dynamics (CFD) model of the so-called “flow field”, i.e. a flow manifold, based on Twelve’s CAD drawings, to evaluate how these flow fields perform as a heat exchanger for the generated heat. We explore both a single cell and a 3-cell stack operating in parallel, where heat generated in one cell can now be transferred to another cell. We evaluate how performance is affected when environmental heat losses are taken into account. Finally, we leverage topology optimization to explore the types of design features a computational optimization algorithm would suggest to supplement our intuition. Overall, our work aims to provide design recommendations for CO2 electrolyzer flow fields and provides a foundation for future studies of flow field optimization.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Enhanced pool boiling heat transfer using novel inverted trapezoid microgroove structures

Pool boiling heat transfer improvements with enhanced surfaces have been extensively studied for various hydrofluorocarbon (HFC) refrigerants. However, there is a limited number of studies in the open literature that focus on the pool boiling heat transfer characteristics of hydrofluoroolefin (HFO) refrigerants on enhanced surfaces. This study aims to address this gap by analyzing the pool boiling behavior of HFO refrigerants, specifically R1234yf and R1234ze(E). Experiments were conducted on both plain surfaces and novel inverted trapezoid microgroove structures. Further, the experimental results indicate that the microgroove structures can improve heat transfer coefficients by up to 80% compared to plain surfaces. Additionally, the performance of R1234yf and R1234ze(E) was compared to that of R134. It was observed that R1234yf exhibited comparable performance to R134a, while R1234ze(E) showed slightly lower performance. To assess the influence of saturation temperature on pool boiling heat transfer, tests were conducted at different saturation temperatures of 15℃, 25℃, and 35℃. The findings revealed that the pool boiling heat transfer coefficient increases with rising saturation temperature.

42 ENGINEERING↗

Analysis on the Preliminary Gap Conductance Test with Single Primary Heat Extraction and Removal Emulator

Microreactor is a type of nuclear reactor that is intended to produce thermal energy from the micro and integrated design. Among various microreactor roadmaps, microreactor with heat pipes is one of the promising designs that under active development. At Idaho National Laboratory (INL) and supported by the Department of Energy (DOE) Microreactor Program (MRP), a Single Primary Heat Extraction and Removal Emulator (SPHERE) was developed. The main purpose of SPHRE is to understand thermal performance of heat pipe in the conjunction of heat source without using nuclear material. The heat pipe used in the SPHERE has sodium as a working fluid, with Argon gas in the vapor region, thus this heat pipe is variable conductance heat pipe (VCHP). The volume of non-condensable gas changes with power and elapsed time, so the area covered by non-condensable gas changes. This gives an effect that passively controls the cooling capability of condenser section. This preliminary experiment was intended to perform a gap conductance experiment that reveals heat transfer characteristics of gas at the gap around the heat pipe. However, there are not many experimental data that deals with heat transfer of the gas at the gap around heat pipe. In this research, the preliminary experimental result regarding to the heat pipe performance with different composition of gas at the gap, level of power is presented. The experimental data will be used for the validation study of SOCKEYE as a future plan.

42 ENGINEERING↗