Preshot Report for the NIF DDCyl Campaign: H_Hyd_DDCyl_DRT_AAA/BBB/CCC
The first two cylinder shot days on the National Ignition Facility, allocated through the Discovery Science program, provided a successful demonstration of the cylinder platform on the NIF. Both of these shot days used cylinders that were nominally 3 times larger in radial dimension than cylinders fielded at the OMEGA laser facility, here referred to as scale-3 targets. In the first Discovery Science shot day, we demonstrated that Rayleigh-Taylor instability growth during the deceleration phase is scale-invariant between the scale-1 OMEGA experiments and similarly tailored scale-3 NIF experiments at the same convergence ratio of CR=initial radius/final radius=2.25. In the second Discovery Science shot day, we increased the convergence ratio by lowering the density of the central foam from 300 mg/cm 3 to roughly 40 mg/cm 3 with the same laser drive, resulting in a higher CR=5 at the time when the rebounding shock strikes the aluminum marker. We also greatly improved the imaging setup for the second shot day, resulting in much higher quality (greater signal-to-noise) radiographs of the implosion. This current shot day was awarded through the High Energy Density (HED) Council, following this demonstration of platform viability. It was originally scheduled for June 2020, but it was postponed several times due to the COVID-19 pandemic. It is currently scheduled for January 6, 2021. For this shot day, we will increase the radial dimension of the cylinder to four times the OMEGA-scale targets, and these will be referred to as scale-4 cylinders. Increasing the radial dimension of the target is advantageous as we push these targets to higher convergence ratio. By starting with an initially larger target, the target can push to a higher CR while maintaining the same final viewing area. Other than the larger radial dimension, the targets are very similar in design to the previous ones, consisting of an epoxy ablator, an embedded aluminum marker layer, and a low density central CH foam. These will also use a 40 mg/cm3 CH foam, reaching a CR~4.5 with the same laser energy (the added target mass reduces the final CR slightly). Note that this is NOT designed to be scale-invariant with the previous scale-1 OMEGA and scale-3 NIF shots. It was determined that the laser energy required to achieve a scale-invariant implosion was above the allowable optics damage limits (though achievable on the NIF) for these scale-4 targets.