Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “H- source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Computational Study of an Iron(II) Polypyridine Electrocatalyst for CO 2 Reduction: Key Roles for Intramolecular Interactions in CO 2 Binding and Proton Transfer

A solar-driven conversion of CO 2 into fuels by artificial photosynthesis would not only mitigate the greenhouse effect but also provide an alternative to obtain fuels in a renewable fashion. To this end, the new iron polypyridine catalyst [Fe(bpy NHEt PY2Me)L 2 ] 2+ (L = H 2 O, CH 3 CN) was recently developed for the electrochemical reduction of CO 2 to CO. Here, we performed density functional theory (DFT) electronic structure calculations to shed light on a possible pathway for CO 2 reduction and the origin of the selectivity between CO 2 reduction versus the hydrogen evolution reaction. The metal center remains Lewis acidic throughout the reduction process due to ligand loss and mainly ligand-based reduction stabilized by antiferromagnetic coupling to a high-spin Fe(II) center. This results in a high barrier for hydride formation but a facile addition and activation of CO 2 via an η 2 coordination and stabilizing hydrogen bonding by the amine group. The second unoccupied equatorial coordination site opens up the possibility for an intramolecular protonation with a coordinated water ligand. This facilitates protonation because not only CO 2 but also the proton source H 2 O is activated and properly aligned for a proton transfer due to the Fe-OH 2 bond; consequently, both protonation steps are facile. The moderate ligand field allows a rapid ligand exchange for a second intramolecular protonation step and facilitates an exergonic CO release. The lower selectivity of the related [Fe(bpy OH PY2Me)L 2 ] 2+ complex can be related to its more acidic second coordination sphere, which enables an intramolecular proton transfer that is kinetically competitive with CO 2 addition.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Impedance Measurement of an Antenna with Hydrogen Plasma Driven by 13.56 MHz-rf for J-PARC H{sup -} ion source

In order to satisfy the Japan Proton Accelerator Research Complex (J-PARC) second stage requirements of an H{sup -} ion beam current of 50 mA and a life-time of 2000 hours, the development of a 13.56 MHz-rf-driven H{sup -} ion source was started by using an antenna developed at the Spallation Neutron Source (SNS). As the first step, the impedance of an antenna with hydrogen plasma, which is one of the most important parameters, was measured. For an rf-power of 0 kW, 1.25 kW or 7.45 kW, it was measured as j84.19+5.107 {Omega}, j80.22+11.82 {Omega} or j58.24+21.16 {Omega}, respectively. Its real-part had a rather large value and rather large rf-power dependence unexpectedly. By using the measured impedance, the circuit to produce rf-plasma in the plasma chamber on a -50 kV potential with a 13.56 MHz-rf-source on the ground potential was designed by the circuit simulation code LTSpice IV.

43 PARTICLE ACCELERATORS↗

Coupling of a High-Resolution Ambient Pressure Drift Tube Ion Mobility Spectrometer to a Commercial Time-of-flight Mass Spectrometer

Ion mobility spectrometry provides information about molecular structures of ions. Hence, high resolving power allows separation of isomers which is of major interest in several applications. In this work, we couple our high-resolution ion mobility spectrometer (IMS) with a resolving power of R{sub p} = 100 to a time-of-flight mass spectrometer (TOF-MS). Besides, the benefit of an increased resolving power such an IMS-MS also helps analyzing and understanding the ionization processes in IMS. Usually, the coupling between IMS and TOF-MS is realized by synchronizing data acquisition of the IMS and MS resulting in two-dimensional data containing ion mobility and mass spectra. However, due to peak widths of less than 100 μs in our high-resolution IMS, this technique is not practicable due to significant peak broadening during the ion transfer into the MS and an insufficient data acquisition rate of the MS. Thus, a novel but simple interface between the IMS and MS has been designed which minimizes ion losses, allows recording of ion mobility at full IMS resolving power, and enables a shuttered transmission of ions into the MS. The interface is realized by replacing the Faraday plate used in IMS by a Faraday grid that is shielded by two additional aperture grids. For demonstration, positive product ions of benzene, toluene, and m-xylene in air are investigated. The IMS is equipped with a radioactive {sup 3}H source. Besides the well-known product ions M{sup +} and M·NO{sup +}, a dimer ion is also observed for benzene and toluene, consisting of two molecules and three further hydrogen atoms. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Designed synthesis of multifunctional Fe{sub 3}O{sub 4}@SiO{sub 2}–NH{sub 2}@CS–Co(II) towards efficient oxidation of ethylbenzene

Highlights: • Cooperative integration of magnetic cores and chitosan layers. • Efficient and durable catalyst for the oxidation of ethylbenzene to acetophenone. • Exceptional results of 82.5% EB conversion and 80.4% AP selectivity. • Magnetic recoverable catalyst with excellent reusability even after 10 times run. - Abstract: The preparation of Co(II) supported magnetic heterogeneous catalyst, i.e. Fe{sub 3}O{sub 4}@SiO{sub 2}–NH{sub 2}@CS–Co, and its efficient and selective catalytic properties toward the oxidation of ethylbenzene to acetophenone are presented. The materials were characterized by various physicochemical techniques such as scanning electron microscopy, transmission electron microscopy, Fourier transform infrared spectroscopy, vibrating sample magnetometer, elemental analysis, inductively coupled plasma-atomic emission spectrometer and X-ray photoelectron spectroscopy, etc. The reaction conditions were thoroughly investigated and highly improved catalytic performance (82.5% conversion of ethylbenzene and 80.1% selectivity to acetophenone) was gained under more mild reaction conditions of lower temperature (70 °C), shorter reaction period (60 min) and cheaper and greener oxygen source (H{sub 2}O{sub 2}). More importantly, it could be reused successively at least 10 times when more than 80% of its catalytic activity maintained.

36 MATERIALS SCIENCE↗

A Status Report and a Comparison of H- Emittance at the Dome and ISTS

Why is the emittance in the H-Dome degrading? Can the H- source run reliably for 28 days at 120 Hz? Are the ISTS diagnostics and/or source good enough to proceed with meaningful experiments? For an entire year an effort to answer these questions was made by several teams across multiple groups. At the end of 2013, beginning of 2014, everything came together and for the most part we now have the answers. This talk concentrates on questions 1 and 3.

43 PARTICLE ACCELERATORS↗

Commissioning of Phase 1 of the LANL RFQ Test Stand - Beam Characterization

A series of numerical start-to-end simulations of Phase 1 of the 750 keV RFQ Test Stand which includes the ion source (H+ duoplasmatron), a 1-Solenoid LEBT, an emittance scan station and a Faraday cup were performed to find a mechanism for the characterization of the proton beam extracted from the duoplasmatron.

43 PARTICLE ACCELERATORS↗

The 1.5 - 3.5 Micron Spectroscopy of the Orion H2 Source

A synopsis of current research with near infrared airborne spectroscopy of the Orion molecular hydrogen emission line source is presented. It is suggested that (H2) is the most abundant molecular species in the interstellar medium and is of paramount importance to understand its behavior and distribution in that medium. The H2 has no permanent electric dipole moment which precludes dipole transitions. It is, however, detected in absorption against background starlight by UV electronic transitions and in the IR through electric quadrupole rotation/vibration and pure rotation emission lines. The physical parameters of this region, in the context of their relationships to other members of the complex family of Orion objects, molecular clouds, compact IR sources, H 2 regions, and shock fronts are described.

Davis, D. S.↗

Investigation of Rotor-Airframe Interaction Noise Associated with Small-Scale Rotary-Wing Unmanned Aircraft Systems

In this study, hover acoustic measurements are taken on isolated rotor-airframe configurations representative of smallscale, rotary-wing unmanned aircraft systems (UAS). Each rotor-airframe configuration consists of two fixed-pitch blades powered by a brushless motor, with a simplified airframe geometry intended to represent a generic multicopter arm. In addition to acoustic measurements, CFD-based aeroacoustic predictions are implemented on a subset of the experimentally tested rotor-airframe configurations in an effort to better understand the noise content of the rotor-airframe systems. Favorable agreements are obtained between acoustic measurements and predictions, based on both time- and frequency-domain post-processing techniques. Results indicate that close proximity of airframe surfaces result in the generation of considerable tonal acoustic content in the form of harmonics of the rotor blade passage frequency (BPF). Analysis of the acoustic prediction data shows that the presence of the airframe surfaces can generate noise levels either comparable to or greater than the rotor blade surfaces under certain rotor tip clearance conditions. Analysis of the on-surface Ffowcs Williams and Hawkings (FW-H) source terms provide insight as to the predicted physical noise-generating mechanisms on the rotor and airframe surfaces.

Zawodny, Nikolas S.↗

Fermilab PXIE Beam Diagnostics Development and Testing at the HINS Beam Facility

Fermilab is planning the construction of a prototype front end of the Project X linac. The Project X Injector Experiment (PXIE) is expected to accelerate 1 mA CW H- beam up to 30 MeV. Some of the major goals of the project are to test a CW RFQ and H- source, a broadband bunch-by-bunch beam chopper and a low-energy superconducting linac. The successful characterization and operation of such an accelerator place stringent requirements on beamline diagnostics. These crucial beam measurements include bunch currents, beam orbit, beam phase, bunch length, transverse profile and emittance and beam halo and tails, as well as the extinction performance of the broadband chopper. This paper presents PXIE beam measurement requirements and instrumentation development plans. Presented are plans to test key instruments at the Fermilab High Intensity Neutrino Source (HINS) beam facility. Since HINS is already an operational accelerator, utilizing HINS for instrumentation testing will allow for quicker development of the required PXIE diagnostics.

43 PARTICLE ACCELERATORS↗

Emittance measurements for optimum operation of the J-PARC RF-driven H{sup −} ion source

In order to satisfy the Japan Proton Accelerator Research Complex (J-PARC) second stage requirements of an H{sup −} ion beam of 60mA within normalized emittances of 1.5πmm•mrad both horizontally and vertically, a flat top beam duty factor of 1.25% (500μs×25Hz) and a life-time of longer than 1month, the J-PARC cesiated RF-driven H{sup −} ion source was developed by using an internal-antenna developed at the Spallation Neutron Source (SNS). The transverse emittances of the source were measured with various conditions to find out the optimum operation conditions minimizing the horizontal and vertical rms normalized emittances. The transverse emittances were most effectively reduced by operating the source with the plasma electrode temperature lower than 70°C. The optimum value of the cesium (Cs) density around the beam hole of the plasma electrode seems to be proportional to the plasma electrode temperature. The fine control of the Cs density is indispensable, since the emittances seem to increase proportionally to the excessiveness of the Cs density. Furthermore, the source should be operated with the Cs density beyond a threshold value, since the plasma meniscus shape and the ellipse parameters of the transverse emittances seem to be changed step-function-likely on the threshold Cs value.

43 PARTICLE ACCELERATORS↗

Development of a compact filament-discharge multi-cusp H{sup -} ion source

A 14 MeV medical cyclotron with the external ion source has been designed and is being constructed at China Institute of Atomic Energy. The H{sup -} ion will be accelerated by this machine and the proton beam will be extracted by carbon strippers in dual opposite direction. The compact multi-cusp H{sup -} ion source has been developed for the cyclotron. The 79.5 mm long ion source is 48 mm in diameter, which is consisting of a special shape filament, ten columns of permanent magnets providing a multi-cusp field, and a three-electrode extraction system. So far, the 3 mA/25 keV H{sup -} beam with an emittance of 0.3 {pi} mm mrad has been obtained from the ion source. The paper gives the design details and the beam test results. Further experimental study is under way and an extracted beam of 5 mA is expected.

43 PARTICLE ACCELERATORS↗

Maintenance and operation procedure, and feedback controls of the J-PARC RF-driven H{sup −} ion source

In order to satisfy the Japan Proton Accelerator Research Complex (J-PARC) second stage requirements of an H{sup −} ion beam of 60mA within normalized emittances of 1.5πmm•mrad both horizontally and vertically, a flat top beam duty factor of 1.25% (500μs×25Hz) and a life-time of longer than 1month, the J-PARC cesiated RF-driven H{sup −} ion source was developed by using an internal-antenna developed at the Spallation Neutron Source (SNS). The maintenance and operation procedure to minimize the plasma chamber (PCH) replacement time on the beam line, which is very important to maximize the J-PARC beam time especially for an antenna failure, is presented in this paper. The PCH preserved by filling argon (Ar) gas inside after pre-conditioning including pre-cesiation to produce the required beam at a test-stand successfully produced the required beam on the beam line with slight addition of cesium (Cs). The methods of the feedback controls of a 2MHz-RF-matching, an H{sup −} ion beam intensity and the addition of Cs are also presented. The RF-matching feedback by using two vacuum variable capacitors (VVCs) and RF-frequency shift produced the almost perfect matching with negligibly small reflected RF-power. The H{sup −} ion beam intensity was controlled within errors of ±0.1mA by the RF-power feedback. The amount of Cs was also controlled by remotely opening a Cs-valve to keep the RF-power lower than a settled value.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Plasma meniscus and extraction electrode studies of the ISIS H{sup -} ion source

In order to reduce the emittance and increase the transported beam current from the ISIS Penning-type H{sup -} ion source, improvements to the extraction system are required. This ion source is currently being commissioned on the front end test stand at the Rutherford Appleton Laboratory, which demands higher extraction energies, higher beam currents, and smaller emittances. To facilitate this, the present geometry requires optimization. This paper details the experimental and simulation studies performed of the plasma meniscus and the possible electrode geometry modifications needed to extract the highest quality beam.

43 PARTICLE ACCELERATORS↗

High-efficiency purification of CH 4 and H 2 energy sources enabled by a phosphotungstic acid-supported Os single-atom catalyst

Methane (CH 4 ) and hydrogen (H 2 ) show promise as low-carbon energy sources, but their impurities, including H 2 and CO, pose challenges for storage and use. To address these challenges, a robust purification protocol for CH 4 and/or H 2 , combined with the catalytic conversion of impurities into CO 2 and H 2 O, is a compelling solution. Here, in this work, we investigated 11 phosphotungstic acid (PTA)-supported single-atom catalysts (SACs) by density functional theory (DFT) computations. Os 1 /PTA SACs exhibited superior catalytic activity, and the ease of oxidation follows the CO > H 2 > CH 4 order. It facilitated efficient purification of CH 4 in solvents such as water, MeOH, and various others. For H 2 purification, Os 1 /PTA SACs demonstrated excellent performance in gas, water, and MeOH. Notably, in water and MeOH, it selectively removed CO without consuming H 2 with low free energy barriers. The strong Os-PTA interactions and charge transfer mechanism contributed to its exceptional catalytic activity. Our findings shed light on SAC behavior and their potential for efficient CH 4 and H 2 purification. By addressing impurity challenges and improving clean energy utilization, these findings contribute to the development of sustainable energy technologies.

30 DIRECT ENERGY CONVERSION↗

Optimization of the beam extraction systems for the Linac4 H{sup −} ion source

The development of the Linac 4 and its integration into CERN’s acceleration complex is part of the foreseen luminosity upgrade of the Large Hadron Collider (LHC). The goal is to inject a 160 MeV H{sup −} beam into the CERN PS Booster (PSB) in order to increase the beam brightness by a factor of 2 compared to the 50 MeV proton linac, Linac 2, that is currently in operation. The requirements for the ion source are a 45 keV H{sup −} beam of 80 mA intensity, 2 Hz repetition rate and 0.5 ms pulse length within a normalized rms-emittance of 0.25 mm· mrad. The previously installed beam extraction system has been designed for an H{sup −} ion beam intensity of 20 mA produced by an RF-volume source with an electron to H{sup −} ratio of up to 50. For the required intensity upgrades of the Linac4 ion source, a new beam extraction system is being produced and tested; it is optimized for a cesiated surface RF-source with a nominal beam current of 40 mA and an electron to H{sup −} ratio of 4. The simulations, based on the IBSIMU code, are presented. At the Brookhaven National Laboratory (BNL), a peak beam current of more than 100 mA was demonstrated with a magnetron H{sup −} source at an energy of 35 keV and a repetition rate of 2 Hz. A new extraction system is required to operate at an energy of 45 keV; simulation of a two stage extraction system dedicated to the magnetron is presented.

43 PARTICLE ACCELERATORS↗

Implementation of Design Changes Towards a More Reliable, Hands-off Magnetron Ion Source

As the main H- ion source for the accelerator complex, magnetron ion sources have been used at Fermilab since the 1970’s. At the offline test stand, new R&D is carried out to develop and upgrade the present magnetron-type sources of H- ions of up to 80 mA and 35 keV beam energy in the context of the Proton Improvement Plan. The aim of this plan is to provide high-power proton beams for the experiments at FNAL. In order to reduce the amount of tuning and monitoring of these ion sources, a new electronic system consisting of a current-regulated arc discharge modulator allow the ion source to run at a constant arc current for improved beam output and operation. A solenoid-type gas valve feeds H2 gas into the source precisely and independently of ambient temperature. This summary will cover several studies and design changes that have been tested and will eventually be implemented on the operational magnetron sources at Fermilab. Innovative results for this type of ion source include cathode geometries, solenoid gas valves, current controlled arc pulser, cesium boiler redesign, gas mixtures of hydrogen and nitrogen, and duty factor reduction, with the aim to improve source lifetime, stability, and reducing the amount of tuning needed. In this summary, I will highlight the advances made in ion sources at Fermilab and will outline the directions of the continuing R&D effort.

43 PARTICLE ACCELERATORS↗

Inferring the source of evaporated waters using stable H and O isotopes

Stable isotope ratios of H and O are widely used to identify the source of water, e.g., in aquifers, river runoff, soils, plant xylem, and plant-based beverages. In situations where the sampled water is partially evaporated, its isotope values will have evolved along an evaporation line (EL) in δ 2 H/δ 18 O space, and back-correction along the EL to its intersection with a meteoric water line (MWL) has been used to estimate the source water’s isotope ratios. Here, we review the theory underlying isotopic estimation of source water for evaporated samples (iSW E ). We note potential for bias from a commonly used regression-based approach for EL slope estimation and suggest that a model-based approach may be preferable if assumptions of the regression approach are not valid. We then introduce a mathematical framework that eliminates the need to explicitly estimate the EL–MWL intersection, simplifying iSW E analysis and facilitating more rigorous uncertainty estimation. We apply this approach to data from the US EPA's 2007 National Lakes Assessment. We find that data for most lakes are consistent with a water source similar to annual runoff, estimated from monthly precipitation and evaporation within the lake basin. Strong evidence for both summer- and winter-biased sources exists, however, with winter bias pervasive in most snow-prone regions. Furthermore, the new analytical framework should improve the rigor of iSW E in ecohydrology and related sciences, and our initial results from US lakes suggest that previous interpretations of lakes as unbiased isotope integrators may only be valid in certain climate regimes.

54 ENVIRONMENTAL SCIENCES↗