Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Gradient descent”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Scatter correction in cone-beam CT via a half beam blocker technique allowing simultaneous acquisition of scatter and image information

Purpose: X-ray scatter incurred to detectors degrades the quality of cone-beam computed tomography (CBCT) and represents a problem in volumetric image guided and adaptive radiation therapy. Several methods using a beam blocker for the estimation and subtraction of scatter have been proposed. However, due to missing information resulting from the obstruction of the blocker, such methods require dual scanning or dynamically moving blocker to obtain a complete volumetric image. Here, we propose a half beam blocker-based approach, in conjunction with a total variation (TV) regularized Feldkamp-Davis-Kress (FDK) algorithm, to correct scatter-induced artifacts by simultaneously acquiring image and scatter information from a single-rotation CBCT scan. Methods: A half beam blocker, comprising lead strips, is used to simultaneously acquire image data on one side of the projection data and scatter data on the other half side. One-dimensional cubic B-Spline interpolation/extrapolation is applied to derive patient specific scatter information by using the scatter distributions on strips. The estimated scatter is subtracted from the projection image acquired at the opposite view. With scatter-corrected projections where this subtraction is completed, the FDK algorithm based on a cosine weighting function is performed to reconstruct CBCT volume. To suppress the noise in the reconstructed CBCT images produced by geometric errors between two opposed projections and interpolated scatter information, total variation regularization is applied by a minimization using a steepest gradient descent optimization method. The experimental studies using Catphan504 and anthropomorphic phantoms were carried out to evaluate the performance of the proposed scheme. Results: The scatter-induced shading artifacts were markedly suppressed in CBCT using the proposed scheme. Compared with CBCT without a blocker, the nonuniformity value was reduced from 39.3% to 3.1%. The root mean square error relative to values inside the regions of interest selected from a benchmark scatter free image was reduced from 50 to 11.3. The TV regularization also led to a better contrast-to-noise ratio. Conclusions: An asymmetric half beam blocker-based FDK acquisition and reconstruction technique has been established. The proposed scheme enables simultaneous detection of patient specific scatter and complete volumetric CBCT reconstruction without additional requirements such as prior images, dual scans, or moving strips.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improving best-phase image quality in cardiac CT by motion correction with MAM optimization

Purpose: Research in image reconstruction for cardiac CT aims at using motion correction algorithms to improve the image quality of the coronary arteries. The key to those algorithms is motion estimation, which is currently based on 3-D/3-D registration to align the structures of interest in images acquired in multiple heart phases. The need for an extended scan data range covering several heart phases is critical in terms of radiation dose to the patient and limits the clinical potential of the method. Furthermore, literature reports only slight quality improvements of the motion corrected images when compared to the most quiet phase (best-phase) that was actually used for motion estimation. In this paper a motion estimation algorithm is proposed which does not require an extended scan range but works with a short scan data interval, and which markedly improves the best-phase image quality. Methods: Motion estimation is based on the definition of motion artifact metrics (MAM) to quantify motion artifacts in a 3-D reconstructed image volume. The authors use two different MAMs, entropy, and positivity. By adjusting the motion field parameters, the MAM of the resulting motion-compensated reconstruction is optimized using a gradient descent procedure. In this way motion artifacts are minimized. For a fast and practical implementation, only analytical methods are used for motion estimation and compensation. Both the MAM-optimization and a 3-D/3-D registration-based motion estimation algorithm were investigated by means of a computer-simulated vessel with a cardiac motion profile. Image quality was evaluated using normalized cross-correlation (NCC) with the ground truth template and root-mean-square deviation (RMSD). Four coronary CT angiography patient cases were reconstructed to evaluate the clinical performance of the proposed method. Results: For the MAM-approach, the best-phase image quality could be improved for all investigated heart phases, with a maximum improvement of the NCC value by 100% and of the RMSD value by 81%. The corresponding maximum improvements for the registration-based approach were 20% and 40%. In phases with very rapid motion the registration-based algorithm obtained better image quality, while the image quality of the MAM algorithm was superior in phases with less motion. The image quality improvement of the MAM optimization was visually confirmed for the different clinical cases. Conclusions: The proposed method allows a software-based best-phase image quality improvement in coronary CT angiography. A short scan data interval at the target heart phase is sufficient, no additional scan data in other cardiac phases are required. The algorithm is therefore directly applicable to any standard cardiac CT acquisition protocol.

60 APPLIED LIFE SCIENCES↗

SU-E-J-37: Combining Proton Radiography and X-Ray CT Information to Better Estimate Relative Proton Stopping Power in a Clinical Environment

Purpose: In standard proton therapy clinical practice, proton stopping power uncertainties are in the order of 3.5%, which affects the ability of placing the proton Bragg peak at the edge of the tumor. The innovating idea of this project is to approach the uncertainty problem in RSP by using combined information from X-ray CT and proton radiography along a few beam angles. In addition, this project aims to quantify the systematic error introduced by the theoretical models (Janni, ICRU49, Bischel) for proton stopping power in media. Methods: A 3D phantom of 36 cm3 composed of 9 materials randomly placed is created. Measured RSP values are obtained using a Gammex phantom with a proton beam. Theoretical RSP values are calculated with Beth-Block equation in combination with three databases (Janni, ICRU49 and Bischel). Clinical RSP errors are simulated by introducing a systematic (1.5%, 2.5%, 3.5%) and a random error (+/−0.5%) to the theoretical RSP. A ray-tracing algorithm uses each of these RSP tables to calculate energy loss for proton crossing the phantom through various directions. For each direction, gradient descent (GD) method is done on the clinical RSP table to minimize the residual energy difference between the simulation with clinical RSP and with theoretical RSP. The possibility of a systematic material dependent error is investigated by comparing measured RSP to theoretical RSP as calculated from the three models. Results: Using 10,000 iterations on GD algorithm, RSP differences between theoretical values and clinical RSP have converged (<1%) for each error introduced. Results produced with ICRU49 have the smallest average difference (0.021%) to the measured RSP. Janni (1.168%) and Bischel (−0.372%) database shows larger systematic errors. Conclusion: Based on these results, ray-tracing optimisation using information from proton radiography and X-ray CT demonstrates a potential to improve the proton range accuracy in a clinical environment.

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-J-83: Ion Imaging to Better Estimate In-Vivo Relative Stopping Powers Using X-Ray CT Prior-Knowledge Information

Purpose: To reduce uncertainties in relative stopping power (RSP) estimates for ions (alpha and carbon) by using Ion radiographic-imaging and X-ray CT prior-knowledge. Methods: A 36×36 phantom matrix composed of 9 materials with different thicknesses and randomly placed is generated. Theoretical RSPs are calculated using stopping power (SP) data from three references (Janni, ICRU49 and Bischel). We introduced an artificial systematic error (1.5%, 2.5% or 3.5%) and a random error (<0.5%) to the SP to simulated patient ion-range errors present in clinic environment. Carbon/alpha final energy for each RSPs set (theoretical and from CT images) is obtained with a ray-tracing algorithm. A gradient descent (GD) method is used to minimize the difference in exit particle energy, between theory and X-ray CT RSP maps, by iteratively correcting the RSP map from X-ray CT. Once a new set of RSPs is obtained for a direction a new optimization is done over other direction using the RSPs from the previous optimization. Theoretical RSPs are compared with experimental RSPs obtained with Gammex Phantom. Results: Preliminary results show that optimized RSP values can be obtained with smaller uncertainties (<1%) than clinical RSPs (1.5% to 3.5%). Theoretical values from three different references show uncertainties, up to 3% from experimental values. Further investigation will consider prior-knowledge from RSP obtained with CT images and ion radiographies from Monte Carlo Simulations. Conclusion: GD and ray-tracing methods have been implemented to reduce RSP uncertainties from values obtained for clinical treatment. Experimental RSPs will be obtained using carbon/alpha beams to consider the existence of material dependent systematic errors. Based on the results, it is hoped to show that using ray-tracing optimization with ion radiography and prior knowledge on RPSs, treatment planning accuracy and cost-effectiveness can be improved.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-J-195: Quantification of Rotations and Deformations in Head and Heck Radiotherapy

Purpose: To quantify the magnitude of patient rotations and deformations over the course of head and neck radiotherapy. Methods: 45 CBCT images acquired weekly were selected retrospectively from 5 head and neck cancer patients. CBCT images were registered to the corresponding planning CT images using translation, rigid-body, and cubic B-spline deformable transformations. Elastix ( elastix.isi.uu.nl ), an open-source public domain registration algorithm, was used for all registrations with mutual information as similarity metric and gradient descent as optimization. Four-level multiresolution approach was employed with 2 cm B-spline grid spacing at the finest resolution. Registration qualities were visually verified. Rotational occurrences were quantified from the rigid-body registrations. The magnitude of deformations in planning target volumes (PTV) and organs were quantified from the deformation vector fields with rigid registrations as baseline. Results: The measured rotations (mean±std) were 1.0±1.0 deg, - 0.3±1.0 deg, and 0.1±0.8 deg in the sagittal, coronal, and axial plains respectively. The estimated magnitudes of deformations (mean±std) were 3.4±2.1 mm for PTVs, 2.9±1.2 mm for parotid glands, 2.8±1.2 mm for mandible, and 2.2±1.1 mm for spinal cord. The overall deformation in the body contour was 4.3±4.3 mm. The organ spatial deviation due to rotation was small and approximately 8.4% of that from deformations. Results varied among patients. Conclusion: Rotations occurred about 1.0 deg (1SD) in the H'N area. Daily geometric deviation of target volumes was considerable and mainly from tissue deformation than rotations. Proper safety margin is necessary for adequate target coverage. Online plan adaptation may mitigate the daily differences between the plan and actual patient poses. Partially supported by a grant from Varian Medical Systems, Palo Alto, CA.

60 APPLIED LIFE SCIENCES↗

Semiautomatic registration of 3D transabdominal ultrasound images for patient repositioning during postprostatectomy radiotherapy

Purpose: The aim of the present work is to propose and evaluate registration algorithms of three-dimensional (3D) transabdominal (TA) ultrasound (US) images to setup postprostatectomy patients during radiation therapy. Methods: Three registration methods have been developed and evaluated to register a reference 3D-TA-US image acquired during the planning CT session and a 3D-TA-US image acquired before each treatment session. The first method (method A) uses only gray value information, whereas the second one (method B) uses only gradient information. The third one (method C) combines both sets of information. All methods restrict the comparison to a region of interest computed from the dilated reference positioning volume drawn on the reference image and use mutual information as a similarity measure. The considered geometric transformations are translations and have been optimized by using the adaptive stochastic gradient descent algorithm. Validation has been carried out using manual registration by three operators of the same set of image pairs as the algorithms. Sixty-two treatment US images of seven patients irradiated after a prostatectomy have been registered to their corresponding reference US image. The reference registration has been defined as the average of the manual registration values. Registration error has been calculated by subtracting the reference registration from the algorithm result. For each session, the method has been considered a failure if the registration error was above both the interoperator variability of the session and a global threshold of 3.0 mm. Results: All proposed registration algorithms have no systematic bias. Method B leads to the best results with mean errors of −0.6, 0.7, and −0.2 mm in left–right (LR), superior–inferior (SI), and anterior–posterior (AP) directions, respectively. With this method, the standard deviations of the mean error are of 1.7, 2.4, and 2.6 mm in LR, SI, and AP directions, respectively. The latter are inferior to the interoperator registration variabilities which are of 2.5, 2.5, and 3.5 mm in LR, SI, and AP directions, respectively. Failures occur in 5%, 18%, and 10% of cases in LR, SI, and AP directions, respectively. 69% of the sessions have no failure. Conclusions: Results of the best proposed registration algorithm of 3D-TA-US images for postprostatectomy treatment have no bias and are in the same variability range as manual registration. As the algorithm requires a short computation time, it could be used in clinical practice provided that a visual review is performed.

60 APPLIED LIFE SCIENCES↗

Sparsity-based acoustic inversion in cross-sectional multiscale optoacoustic imaging

Purpose: With recent advancement in hardware of optoacoustic imaging systems, highly detailed cross-sectional images may be acquired at a single laser shot, thus eliminating motion artifacts. Nonetheless, other sources of artifacts remain due to signal distortion or out-of-plane signals. The purpose of image reconstruction algorithms is to obtain the most accurate images from noisy, distorted projection data. Methods: In this paper, the authors use the model-based approach for acoustic inversion, combined with a sparsity-based inversion procedure. Specifically, a cost function is used that includes the L1 norm of the image in sparse representation and a total variation (TV) term. The optimization problem is solved by a numerically efficient implementation of a nonlinear gradient descent algorithm. TV–L1 model-based inversion is tested in the cross section geometry for numerically generated data as well as for in vivo experimental data from an adult mouse. Results: In all cases, model-based TV–L1 inversion showed a better performance over the conventional Tikhonov regularization, TV inversion, and L1 inversion. In the numerical examples, the images reconstructed with TV–L1 inversion were quantitatively more similar to the originating images. In the experimental examples, TV–L1 inversion yielded sharper images and weaker streak artifact. Conclusions: The results herein show that TV–L1 inversion is capable of improving the quality of highly detailed, multiscale optoacoustic images obtained in vivo using cross-sectional imaging systems. As a result of its high fidelity, model-based TV–L1 inversion may be considered as the new standard for image reconstruction in cross-sectional imaging.

60 APPLIED LIFE SCIENCES↗

SU-D-204-01: A Methodology Based On Machine Learning and Quantum Clustering to Predict Lung SBRT Dosimetric Endpoints From Patient Specific Anatomic Features

Purpose: To develop a data-mining methodology based on quantum clustering and machine learning to predict expected dosimetric endpoints for lung SBRT applications based on patient-specific anatomic features. Methods: Ninety-three patients who received lung SBRT at our clinic from 2011–2013 were retrospectively identified. Planning information was acquired for each patient, from which various features were extracted using in-house semi-automatic software. Anatomic features included tumor-to-OAR distances, tumor location, total-lung-volume, GTV and ITV. Dosimetric endpoints were adopted from RTOG-0195 recommendations, and consisted of various OAR-specific partial-volume doses and maximum point-doses. First, PCA analysis and unsupervised quantum-clustering was used to explore the feature-space to identify potentially strong classifiers. Secondly, a multi-class logistic regression algorithm was developed and trained to predict dose-volume endpoints based on patient-specific anatomic features. Classes were defined by discretizing the dose-volume data, and the feature-space was zero-mean normalized. Fitting parameters were determined by minimizing a regularized cost function, and optimization was performed via gradient descent. As a pilot study, the model was tested on two esophageal dosimetric planning endpoints (maximum point-dose, dose-to-5cc), and its generalizability was evaluated with leave-one-out cross-validation. Results: Quantum-Clustering demonstrated a strong separation of feature-space at 15Gy across the first-and-second Principle Components of the data when the dosimetric endpoints were retrospectively identified. Maximum point dose prediction to the esophagus demonstrated a cross-validation accuracy of 87%, and the maximum dose to 5cc demonstrated a respective value of 79%. The largest optimized weighting factor was placed on GTV-to-esophagus distance (a factor of 10 greater than the second largest weighting factor), indicating an intuitively strong correlation between this feature and both endpoints. Conclusion: This pilot study shows that it is feasible to predict dose-volume endpoints based on patient-specific anatomic features. The developed methodology can potentially help to identify patients at risk for higher OAR doses, thus improving the efficiency of treatment planning. R01-184173.

60 APPLIED LIFE SCIENCES↗

WE-AB-209-09: Optimization of Rotational Arc Station Parameter Optimized Radiation Therapy

Purpose: To develop a fast optimization method for station parameter optimized radiation therapy (SPORT) and show that SPORT is capable of improving VMAT in both plan quality and delivery efficiency. Methods: The angular space from 0° to 360° was divided into 180 station points (SPs). A candidate aperture was assigned to each of the SPs based on the calculation results using a column generation algorithm. The weights of the apertures were then obtained by optimizing the objective function using a state-of-the-art GPU based Proximal Operator Graph Solver (POGS) within seconds. Apertures with zero or low weight were thrown out. To avoid being trapped in a local minimum, a stochastic gradient descent method was employed which also greatly increased the convergence rate of the objective function. The above procedure repeated until the plan could not be improved any further. A weighting factor associated with the total plan MU also indirectly controlled the complexities of aperture shapes. The number of apertures for VMAT and SPORT was confined to 180. The SPORT allowed the coexistence of multiple apertures in a single SP. The optimization technique was assessed by using three clinical cases (prostate, H&N and brain). Results: Marked dosimetric quality improvement was demonstrated in the SPORT plans for all three studied cases. Prostate case: the volume of the 50% prescription dose was decreased by 22% for the rectum. H&N case: SPORT improved the mean dose for the left and right parotids by 15% each. Brain case: the doses to the eyes, chiasm and inner ears were all improved. SPORT shortened the treatment time by ∼1 min for the prostate case, ∼0.5 min for brain case, and ∼0.2 min for the H&N case. Conclusion: The superior dosimetric quality and delivery efficiency presented here indicates that SPORT is an intriguing alternative treatment modality.

60 APPLIED LIFE SCIENCES↗

Train Like a (Var)Pro: Efficient Training of Neural Networks with Variable Projection

Deep neural networks (DNNs) have achieved state-of-the-art performance across a variety of traditional machine learning tasks, e.g., speech recognition, image classification, and segmentation. The ability of DNNs to efficiently approximate high-dimensional functions has also motivated their use in scientific applications, e.g., to solve partial differential equations and to generate surrogate models. In this paper, we consider the supervised training of DNNs, which arises in many of the above applications. We focus on the central problem of optimizing the weights of the given DNN such that it accurately approximates the relation between observed input and target data. Devising effective solvers for this optimization problem is notoriously challenging due to the large number of weights, nonconvexity, data sparsity, and nontrivial choice of hyperparameters. To solve the optimization problem more efficiently, we propose the use of variable projection (VarPro), a method originally designed for separable nonlinear least-squares problems. Our main contribution is the Gauss--Newton VarPro method (GNvpro) that extends the reach of the VarPro idea to nonquadratic objective functions, most notably cross-entropy loss functions arising in classification. These extensions make GNvpro applicable to all training problems that involve a DNN whose last layer is an affine mapping, which is common in many state-of-the-art architectures. In our four numerical experiments from surrogate modeling, segmentation, and classification, GNvpro solves the optimization problem more efficiently than commonly used stochastic gradient descent (SGD) schemes. Finally, GNvpro finds solutions that generalize well, and in all but one example better than well-tuned SGD methods, to unseen data points.

97 MATHEMATICS AND COMPUTING↗

Bias-Variance Trade-Off in Physics-Informed Neural Networks with Randomized Smoothing for High-Dimensional PDEs

Physics-Informed Neural Networks (PINNs) have triggered a paradigm shift in scientific computing, leveraging mesh-free properties and robust approximation capabilities. While proving effective for low-dimensional partial differential equations (PDEs), the computational cost of PINNs remains a hurdle in high-dimensional scenarios. This is particularly pronounced when computing high-order and high-dimensional derivatives in the physics-informed loss. Randomized Smoothing PINN (RS-PINN) introduces Gaussian noise for stochastic smoothing of the original neural net model, enabling the use of Monte Carlo methods for derivative approximation, which eliminates the need for costly automatic differentiation. Despite its computational efficiency, especially in the approximation of high-dimensional derivatives, RS-PINN introduces biases in both loss and gradients, negatively impacting convergence, especially when coupled with stochastic gradient descent (SGD) algorithms. We present a comprehensive analysis of biases in RS-PINN, attributing them to the nonlinearity of the Mean Squared Error (MSE) loss as well as the intrinsic nonlinearity of the PDE itself. We propose tailored bias correction techniques, delineating their application based on the order of PDE nonlinearity. The derivation of an unbiased RS-PINN allows for a detailed examination of its advantages and disadvantages compared to the biased version. Specifically, the biased version has a lower variance and runs faster than the unbiased version, but it is less accurate due to the bias. To optimize the bias-variance trade-off, we combine the two approaches in a hybrid method that balances the rapid convergence of the biased version with the high accuracy of the unbiased version. In addition to methodological contributions, we present an enhanced implementation of RS-PINN. Extensive experiments on diverse high-dimensional PDEs, including Fokker-Planck, Hamilton-Jacobi-Bellman (HJB), viscous Burgers’, Allen-Cahn, and Sine-Gordon equations, illustrate the bias-variance trade-off and highlight the effectiveness of the hybrid RS-PINN. Empirical guidelines are provided for selecting biased, unbiased, or hybrid versions, depending on the dimensionality and nonlinearity of the specific PDE problem.

97 MATHEMATICS AND COMPUTING↗

Efficient Training of Deep Neural Operator Networks via Randomized Sampling

Neural operators (NOs) employ deep neural networks to learn the mappings between infinitedimensional function spaces. Deep operator network (DeepONet), a popular NO architecture, has demonstrated success in the real-time prediction of complex dynamics across various scientific and engineering applications. In this work, we introduce a random sampling technique to be adopted during the training of DeepONet, aimed at improving the generalization ability of the model, while significantly reducing the computational time. The proposed approach targets the trunk network of the DeepONet model that outputs the basis functions corresponding to the spatiotemporal locations of the bounded domain on which the physical system is defined. While constructing the loss function, DeepONet training traditionally considers a uniform grid of spatiotemporal points at which all the output functions are evaluated for each iteration. This approach leads to a larger batch size, resulting in poor generalization and increased memory demands, due to the limitations of the stochastic gradient descent (SGD) optimizer. The proposed random sampling over the inputs of the trunk net mitigates these challenges, improving generalization and reducing the memory requirements during training, resulting in significant computational gains. We validate our hypothesis through three benchmark examples, demonstrating substantial reductions in training time while achieving comparable or lower overall test errors relative to the traditional training approach. Our results indicate that incorporating randomization in the trunk network inputs during training enhances the efficiency and robustness of DeepONet, offering a promising avenue for improving the framework’s performance in modeling complex physical systems.

Karumuri, Sharmila [Department of Civil & Systems ↗

Integrated Model, Batch and Domain Parallelism in Training Neural Networks

We propose a new integrated method of exploiting model, batch and domain parallelism for the training of deep neural networks (DNNs) on large distributed-memory computers using minibatch stochastic gradient descent (SGD). Our goal is to find an efficient parallelization strategy for a fixed batch size using $P$ processes. Our method is inspired by the communication-avoiding algorithms in numerical linear algebra. We see $P$ processes as logically divided into a $P_r \times P_c$ grid where the $P_r$ dimension is implicitly responsible for model/domain parallelism and the $P_c$ dimension is implicitly responsible for batch parallelism. In practice, the integrated matrix-based parallel algorithm encapsulates these types of parallelism automatically. We analyze the communication complexity and analytically demonstrate that the lowest communication costs are often achieved neither with pure model nor with pure data parallelism. We also show how the domain parallel approach can help in extending the theoretical scaling limit of the typical batch parallel method.

97 MATHEMATICS AND COMPUTING↗

SwitchX : Gmin-Gmax Switching for Energy-efficient and Robust Implementation of Binarized Neural Networks on ReRAM Xbars

Memristive crossbars can efficiently implement Binarized Neural Networks (BNNs) wherein the weights are stored in high-resistance states (HRS) and low-resistance states (LRS) of the synapses. We propose SwitchX mapping of BNN weights onto ReRAM crossbars such that the impact of crossbar non-idealities, that lead to degradation in computational accuracy, are minimized. Essentially, SwitchX maps the binary weights in such a manner that a crossbar instance comprises of more HRS than LRS synapses. We find BNNs mapped onto crossbars with SwitchX to exhibit better robustness against adversarial attacks than the standard crossbar mapped BNNs, the baseline. Finally, we combine SwitchX with state-aware training (that further increases the feasibility of HRS states during weight mapping) to boost the robustness of a BNN on hardware. We find that this approach yields stronger defense against adversarial attacks than adversarial training, a state-of the-art software defense. We perform experiments on a VGG16 BNN with benchmark datasets (CIFAR-10, CIFAR-100 and TinyImagenet) and use Fast Gradient Sign Method (ϵ = 0.05 to 0.3) and Projected Gradient Descent (ϵ = $\frac{2}{255}$ to $\frac{32}{255}$, α = $\frac{2}{255}$) adversarial attacks. We show that SwitchX combined with state-aware training can yield upto ~35% improvements in clean accuracy and ~6–16% in adversarial accuracies against conventional BNNs. Furthermore, an important by-product of SwitchX mapping is increased crossbar power savings, owing to an increased proportion of HRS synapses, which is furthered with state-aware training. We obtain upto ~21–22% savings in crossbar power consumption for state-aware trained BNN mapped via SwitchX on 16 × 16 and 32 × 32 crossbars using the CIFAR-10 and CIFAR-100 datasets.

97 MATHEMATICS AND COMPUTING↗

Efficient QAOA Optimization using Directed Restarts and Graph Lookup

Variational Quantum Algorithms (VQA) aim to enhance the capabilities of Noisy Intermediate-Scale Quantum (NISQ) devices. These algorithms utilize parameterized circuits and classical optimizers to iteratively execute circuits with varying parameters. However, VQA faces computational overheads due to repeated iterations and random restarts. Prior work suggests using basic sub-graphs to transfer parameters for the input graph, reducing optimizer overheads but limiting applicability to structured regular graphs. In real-world applications, random irregular graphs are common, and existing methods are not scalable or practical for such graphs. This paper presents a framework that aims to improve random irregular graphs in VQA. The framework uses graph similarity and important features like total edge counts, average edge counts, and variance. It follows an iterative process to choose basis sub-graphs from a small database and adjust parameters accordingly. Classical optimizers then utilize these parameters to determine when to restart and perform gradient descent. This approach increases the chances of reaching global maximum points.

Wang, Meng↗

Parameter Optimization Toolbox for NS-3 network optimization, NS-3 Parameter Optimization Framework [SWR-18-60]

This simulation-based parameter optimization framework is proposed to tune parameters of different types of communication networks using ns-3 to achieve the optimal network performance. It consists of three main components: an ns-3 packet reporting module; a sampler running simulations with all possible parameter sets for the input parameter variables by using a parallel executor at each generation; and a hybrid optimization algorithm for tuning configurable parameters of hybrid designs and application parameter variables. The proposed hybrid metaheuristic optimization algorithm combines an evolutionary algorithm with a gradient descent function to quickly achieve an approximate globally optimum solution. This software is designed to be used in a multi-core processing Linux environment and run over a long duration of time. The execution time varies depending mainly upon the nature of the ns-3 configuration being simulated. This software includes a custom ns-3 QoS measurement application which must be included with the ns-3 source code during installation of the software.

Hasandka, Adarsh↗

EGSim v1.0

EGSim contains tools aimed at simulating static load flow solutions for power grids. It implements models for loads, generators, and transmission lines. The static load flow solution is computed via gradient descent. SAND20019-4672 M

SciDAC↗

Scalable deep text comprehension for Cancer surveillance on high-performance computing

Background: Deep Learning (DL) has advanced the state-of-the-art capabilities in bioinformatics applications which has resulted in trends of increasingly sophisticated and computationally demanding models trained by larger and larger data sets. This vastly increased computational demand challenges the feasibility of conducting cutting-edge research. One solution is to distribute the vast computational workload across multiple computing cluster nodes with data parallelism algorithms. In this study, we used a High-Performance Computing environment and implemented the Downpour Stochastic Gradient Descent algorithm for data parallelism to train a Convolutional Neural Network (CNN) for the natural language processing task of information extraction from a massive dataset of cancer pathology reports. We evaluated the scalability improvements using data parallelism training and the Titan supercomputer at Oak Ridge Leadership Computing Facility. To evaluate scalability, we used different numbers of worker nodes and performed a set of experiments comparing the effects of different training batch sizes and optimizer functions.Results: We found that Adadelta would consistently converge at a lower validation loss, though requiring over twice as many training epochs as the fastest converging optimizer, RMSProp. The Adam optimizer consistently achieved a close 2nd place minimum validation loss significantly faster; using a batch size of 16 and 32 allowed the network to converge in only 4.5 training epochs.Conclusions: We demonstrated that the networked training process is scalable across multiple compute nodes communicating with message passing interface while achieving higher classification accuracy compared to a traditional machine learning algorithm.

Qiu, John X.↗