Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Gas sample analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Deuterium analysis in zircaloy using ps laser-induced low pressure plasma

An experimental study on picosecond laser induced plasma spectroscopy of a zircaloy sample with low-pressure surrounding helium gas has been carried out to demonstrate its potential applicability to three-dimensional quantitative micro-analysis of deuterium impurities in zircaloy. This was achieved by adopting the optimal experimental condition ascertained in this study, which is specified as 7 mJ laser energy, 1.3 kPa helium pressure, and 50 {mu}s measurement window, and which was found to result in consistent D emission enhancement. Employing these operational parameters, a linear calibration line exhibiting a zero intercept was obtained from zircaloy-4 samples doped with various concentrations of D impurity, regarded as surrogates for H impurity. An additional measurement also yielded a detection limit of about 10 {mu}g/g for D impurity, well below the acceptable threshold of damaging H concentration in zircaloy. Each of these measurements was found to produce a crater size of only 25 {mu}m in diameter, promising its application for performing less-destructive measurements. The result of this study has thus paved the way for conducting a further experiment with hydrogen-doped zircaloy samples and the further technical development of a three-dimensional quantitative micro-analysis of detrimental hydrogen impurity in zircaloy vessels used in nuclear power plants.

36 MATERIALS SCIENCE↗

Analysis of 85Kr: a comparison at the 10-14 level using micro-liter samples

The isotopic abundance of 85Kr in the atmosphere, currently at the level of 10211, has increased by orders of magnitude since the dawn of nuclear age. With a half-life of 10.76 years, 85Kr is of great interest as tracers for environmental samples such as air, groundwater and ice. Atom Trap Trace Analysis (ATTA) is an emerging method for the analysis of rare krypton isotopes at isotopic abundance levels as low as 10214 using krypton gas samples of a few micro-liters. Both the reliability and reproducibility of the method are examined in the present study by an inter-comparison among different instruments. The 85Kr/Kr ratios of 12 samples, in the range of 10213 to 10210, are measured independently in three laboratories: a low-level counting laboratory in Bern, Switzerland, and two ATTA laboratories, one in Hefei, China, and the other in Argonne, USA. The results are in agreement at the precision level of 5%.

MASS SPECTROMETRY↗

Measuring Sub-micron Size Fractionated Particulate Matter on Aluminum Impactor Disks

Sub-micron sized airborne particulate matter is not collected well on regular quartz or glass fiber filter papers. We used a micro-orifice uniform deposit impactor (MOUDI) to size fractionate particulate matter (PM) into six size fractions and deposit it on specially designed high purity thin aluminum disks. The MOUDI separated PM into fractions 56-100 nm, 100-180 nm, 180-320 nm, 320-560 nm, 560-1000 nm, and 1000-1800 nm. Since MOUDI have low flow rates, it takes several days to collect sufficient carbon on 47 mm foil disks. The small carbon mass (20-200 microgram C) and large aluminum substrate ({approx}25 mg Al) presents several challenges to production of graphite targets for accelerator mass spectrometry (AMS) analysis. The Al foil consumes large amounts of oxygen as it is heated and tends to melt into quartz combustion tubes, causing gas leaks. We describe sample processing techniques to reliably produce graphitic targets for {sup 14}C-AMS analysis of PM deposited on Al impact foils.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Temperature Effect over Gas Bubble Evolution in Uranium-10 wt.% Molybdenum alloy Irradiated by Swift Xe Ions

Results from post-irradiation examination (PIE) of U-10Mo binary metallic fuel irradiated by 84 MeV Xe ions at two different temperatures (450°C & 275°C) have been evaluated and reported. The main goal of this study was to understand gas bubble formation (due to accumulation of Xe gas) and corresponding size evolution dependent upon net Xe deposition at two different temperatures, for the U-10Mo fuel samples. From the post ion irradiation examination analysis, it can be concluded that at 450°C the Xe gas bubbles seems to coarsen more easily compared to 275°C. The results of ion irradiation testing can provide initial data that may be beneficial for fuel system down-selections, and for the development and validation of fuel performance models.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Gas-Phase Detection of a Multi-Complex Lanthanide Sample for Nuclear Forensics

Post-detonation nuclear forensics is an area of research that continuously necessitates progress in the reduction of sample analysis time. Rapid analysis is an essential component of the post-detonation process in order to quickly inform relevant officials of the nature and characteristics of a nuclear weapon. In order to address this issue, a new technique has been developed to more quickly isolate and quantify elements and isotopes of interest from nuclear melt glass debris. This process exploits gas-phase chemistry to identify debris constituents in a more timely fashion than currently-practiced techniques. When fully functional, this technique is expected to significantly reduce analysis time for nuclear forensic samples. (authors)

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Tandem pyrolysis evolved gas–gas chromatography–mass spectrometry

Analysis of byproducts from thermal degradation of polymer materials provides a wealth of information about a materials’ composition, thermal stability, degradation mechanisms, and kinetics. However, regardless of the instrumentation used, only limited information is obtainable from a single experiment. Microfurnace technology, when interfaced to a gas chromatography-mass spectrometry (GC-MS), can be used to obtain both thermal and chemical information via evolved gas analysis-MS (EGA-MS) and GC-MS analysis modes. While both EGA-MS and Py-GC-MS are valuable when characterizing polymer materials, at least two experiments on distinct samples are required, which can be a liability for clear interpretation of results from inhomogeneous samples. Here, we seek to overcome this limitation by combining EGA-MS and Py-GC-MS modes in a single experimental setup. Further, this was done by developing new gas line modifications to allow for tandem Pyrolysis Evolved Gas-Gas Chromatography-Mass Spectrometry (Py/EG-GC-MS) analysis. Verification of Py/EG-GC-MS analysis was performed using a polystyrene standard. Results demonstrate successful Py/EG-GC-MS analysis for the first-time showing the potential of these modifications for application in areas where sample is limited or direct correlation of products to the thermal profile is desirable such as in forensics or product-specific kinetics.

36 MATERIALS SCIENCE↗

A high-dispersion molecular gas component in nearby galaxies

We present a comprehensive study of the velocity dispersion of the atomic (H I) and molecular (H{sub 2}) gas components in the disks (R ≲ R {sub 25}) of a sample of 12 nearby spiral galaxies with moderate inclinations. Our analysis is based on sensitive high-resolution data from the THINGS (atomic gas) and HERACLES (molecular gas) surveys. To obtain reliable measurements of the velocity dispersion, we stack regions several kiloparsecs in size, after accounting for intrinsic velocity shifts due to galactic rotation and large-scale motions. We stack using various parameters: the galactocentric distance, star formation rate surface density, H I surface density, H{sub 2} surface density, and total gas surface density. We fit single Gaussian components to the stacked spectra and measure median velocity dispersions for H I of 11.9 ± 3.1 km s{sup –1} and for CO of 12.0 ± 3.9 km s{sup –1}. The CO velocity dispersions are thus, surprisingly, very similar to the corresponding ones of H I, with an average ratio of σ{sub HI}/σ{sub CO}= 1.0 ± 0.2 irrespective of the stacking parameter. The measured CO velocity dispersions are significantly higher (factor of ∼2) than the traditional picture of a cold molecular gas disk associated with star formation. The high dispersion implies an additional thick molecular gas disk (possibly as thick as the H I disk). Our finding is in agreement with recent sensitive measurements in individual edge-on and face-on galaxies and points toward the general existence of a thick disk of molecular gas, in addition to the well-known thin disk in nearby spiral galaxies.

79 ASTRONOMY AND ASTROPHYSICS↗

Efficient collection and preparation of methane from low concentration waters for natural abundance radiocarbon analysis

Freshwater and marine environments constitute the largest global reservoirs of the greenhouse gas methane (CH 4 ) and natural abundance radiocarbon measurements ( 14 C-CH 4 ) can allow for high confidence interpretations about CH 4 dynamics operating in these environments. Collecting sufficient amounts of CH 4 sample for a standard, high precision 14 C-accelerator mass spectrometry (AMS) analysis (~ 200 μg carbon (C)) was previously unfeasible when sampling from low CH 4 concentration waters, such as much of the surface ocean (~ 2 nM), which would require collecting the CH 4 from 8500 L of seawater. The method described here involves pumping 20,000–40,000 L of seawater up from depth through a dissolved gas extraction system, which enables the collection of a sample composed of 100s of L of gas in less than 4 h on station. The large volume extracted gas sample is compressed into a 1.7 L cylinder for transport from the ship to the home laboratory. The home laboratory preparation of each sample to a CH 4 -derived carbon dioxide aliquot for 14 C-AMS analysis is carried out in 3 h on a flow-through vacuum line that simultaneously prepares aliquots for stable isotope analyses (δ 13 C-CH 4 and δ 2 H-CH 4 ). The total process blank of the method is small (5.0 μg CH 4 -C) and composes 1.2% of the average collected and prepared sample (424 ± 163 μg, from a recent campaign; n = 16). Finally, the 14 C-CH 4 blanks prepared on the vacuum line have acceptably low 14 C content (0.23 ± 0.07 percent Modern Carbon (pMC); n = 7) relative to the 14 C-dead (0 pMC) CH 4 from which they are prepared.

54 ENVIRONMENTAL SCIENCES↗

Hyperfine structure and isotope shifts of xenon measured for near-infrared transitions with Doppler-free saturated absorption spectroscopy

Hyperfine structure and isotope shifts of Xe were investigated with Doppler-free saturated absorption spectroscopy for all transitions in the 820-841 nm spectral interval. The Xe samples were commercial gases of natural isotopic abundances. The measurements were performed by employing a widely tunable narrow line Ti:sapphire laser. The hyperfine structures for 129 Xe and 131 Xe were well resolved. For the transitions with the wavelengths in vacuum near 820.860 nm and 841.150 nm also isotope shifts of the even isotopes were clearly observed. The modeling of the shapes of the observed absorption lines qualitatively reproduces experimental spectral profiles. The measured absorption peaks of the hyperfine structure and isotope shifts of Xe isotopes present characteristic spectral fingerprints for their identification. Eventually, quantitative spectral analysis will provide isotopic abundances of natural, as well as radioactive Xe gas samples.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Global Threat Reduction Initiative Fuel Thermo-Physical Characterization Project: Sample Management Plan

This sample management plan provides guidelines for sectioning, preparation, acceptance criteria, analytical path, and end-of-life disposal for the fuel element segments utilized in the Global Threat Reduction Initiative (GTRI), Fuel Thermo-Physical Characterization Project. The Fuel Thermo-Physical Characterization Project is tasked with analysis of irradiated Low Enriched Uranium (LEU) Molybdenum (U-Mo) fuel element samples to support the GTRI conversion program. Sample analysis may include optical microscopy (OM), scanning electron microscopy (SEM) fuel-surface interface analysis, gas pycnometry (density) measurements, laser flash analysis (LFA), differential scanning calorimetry (DSC), thermogravimetry and differential thermal analysis with mass spectroscopy (TG /DTA-MS), Inductively Coupled Plasma Spectrophotometry (ICP), alpha spectroscopy, and Thermal Ionization Mass Spectroscopy (TIMS). The project will utilize existing Radiochemical Processing Laboratory (RPL) operating, technical, and administrative procedures for sample receipt, processing, and analyses. Test instructions (TIs), which are documents used to provide specific details regarding the implementation of an existing RPL approved technical or operational procedure, will also be used to communicate to staff project specific parameters requested by the Principal Investigator (PI). TIs will be developed, reviewed, and issued in accordance with the latest revision of the RPL-PLN-700, RPL Operations Plan. Additionally, the PI must approve all project test instructions and red-line changes to test instructions.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Analytical method for nitroaromatic explosives in radiologically contaminated soil for ISO/IEC 17025 accreditation

Here, unique hazards are presented in the analysis of radiologically contaminated samples. Strenuous safety and security precautions must be in place to protect the analyst, laboratory, and instrumentation used to perform analyses. A validated method has been optimized for the analysis of select nitroaromatic explosives and degradative products using gas chromatography/mass spectrometry via sonication extraction of radiologically contaminated soils, for samples requiring ISO/IEC 17025 laboratory conformance. Target analytes included 2-nitrotoluene, 4-nitrotoluene, 2,6-dinitrotoluene, and 2,4,6-trinitrotoluene, as well as the degradative product 4-amino-2,6-dinitrotoluene. Analytes were extracted from soil in methylene chloride by sonication. Administrative and engineering controls, as well as instrument automation and quality control measures, were utilized to minimize potential human exposure to radiation at all times and at all stages of analysis, from receiving through disposition. Though thermal instability increased uncertainties of these selected compounds, a mean lower quantitative limit of 2.37 µg/mL and mean accuracy of 2.3% relative error and 3.1% relative standard deviation were achieved. Quadratic regression was found to be optimal for calibration of all analytes, with compounds of lower hydrophobicity displaying greater parabolic curve. Blind proficiency testing (PT) of spiked soil samples demonstrated a mean relative error of 9.8%. Matrix spiked analyses of PT samples demonstrated that 99% recovery of target analytes was achieved. To the knowledge of the authors, this represents the first safe, accurate, and reproducible quantitative method for nitroaromatic explosives in soil for specific use on radiologically contaminated samples within the constraints of a nuclear analytical lab.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A colorimetric method to measure in vitro nitrogenase functionality for engineering nitrogen fixation

Biological nitrogen fixation (BNF) is the reduction of N 2 into NH 3 in a group of prokaryotes by an extremely O 2 -sensitive protein complex called nitrogenase. Transfer of the BNF pathway directly into plants, rather than by association with microorganisms, could generate crops that are less dependent on synthetic nitrogen fertilizers and increase agricultural productivity and sustainability. In the laboratory, nitrogenase activity is commonly determined by measuring ethylene produced from the nitrogenase-dependent reduction of acetylene (ARA) using a gas chromatograph. The ARA is not well suited for analysis of large sample sets nor easily adapted to automated robotic determination of nitrogenase activities. Here, we show that a reduced sulfonated viologen derivative (S 2 V red ) assay can replace the ARA for simultaneous analysis of isolated nitrogenase proteins using a microplate reader. We used the S 2 V red to screen a library of NifH nitrogenase components targeted to mitochondria in yeast. Two NifH proteins presented properties of great interest for engineering of nitrogen fixation in plants, namely NifM independency, to reduce the number of genes to be transferred to the eukaryotic host; and O 2 resistance, to expand the half-life of NifH iron-sulfur cluster in a eukaryotic cell. This study established that NifH from Dehalococcoides ethenogenes did not require NifM for solubility, [Fe-S] cluster occupancy or functionality, and that NifH from Geobacter sulfurreducens was more resistant to O 2 exposure than the other NifH proteins tested. It demonstrates that nitrogenase components with specific biochemical properties such as a wider range of O 2 tolerance exist in Nature, and that their identification should be an area of focus for the engineering of nitrogen-fixing crops.

59 BASIC BIOLOGICAL SCIENCES↗

Morphology and molecular gas fractions of local luminous infrared galaxies as a function of infrared luminosity and merger stage

We present a new, detailed analysis of the morphologies and molecular gas fractions (MGFs) for a complete sample of 65 local luminous infrared galaxies from Great Observatories All-Sky Luminous Infrared Galaxies (LIRG) Survey using high resolution I-band images from The Hubble Space Telescope, the University of Hawaii 2.2 m Telescope and the Pan-STARRS1 Survey. Our classification scheme includes single undisturbed galaxies, minor mergers, and major mergers, with the latter divided into five distinct stages from pre-first pericenter passage to final nuclear coalescence. We find that major mergers of molecular gas-rich spirals clearly play a major role for all sources with L{sub IR}>10{sup 11.5}L{sub ⊙}; however, below this luminosity threshold, minor mergers and secular processes dominate. Additionally, galaxies do not reach L{sub IR}>10{sup 12.0}L{sub ⊙} until late in the merger process when both disks are near final coalescence. The mean MGF (MGF = M{sub H{sub 2}}/(M{sub ∗}+M{sub H{sub 2}})) for non-interacting and early-stage major merger LIRGs is 18 ± 2%, which increases to 33 ± 3%, for intermediate stage major merger LIRGs, consistent with the hypothesis that, during the early-mid stages of major mergers, most of the initial large reservoir of atomic gas (HI) at large galactocentric radii is swept inward where it is converted into molecular gas (H{sub 2}).

79 ASTRONOMY AND ASTROPHYSICS↗

Online elemental analysis of process gases with ICP-OES: A case study on waste wood combustion

Highlights: Black-Right-Pointing-Pointer Simultaneous measurements of 23 elements in process gases of a waste wood combustor. Black-Right-Pointing-Pointer Mobile ICP spectrometer allows measurements of high quality at industrial plants. Black-Right-Pointing-Pointer Continuous online measurements with high temporal resolution. Black-Right-Pointing-Pointer Linear correlations among element concentrations in the raw flue gas were detected. Black-Right-Pointing-Pointer Novel sampling and calibration methods for ICP-OES analysis of process gases. - Abstract: A mobile sampling and measurement system for the analysis of gaseous and liquid samples in the field was developed. An inductively coupled plasma optical emission spectrometer (ICP-OES), which is built into a van, was used as detector. The analytical system was calibrated with liquid and/or gaseous standards. It was shown that identical mass flows of either gaseous or liquid standards resulted in identical ICP-OES signal intensities. In a field measurement campaign trace and minor elements in the raw flue gas of a waste wood combustor were monitored. Sampling was performed with a highly transport efficient liquid quench system, which allowed to observe temporal variations in the elemental process gas composition. After a change in feedstock an immediate change of the element concentrations in the flue gas was detected. A comparison of the average element concentrations during the combustion of the two feedstocks showed a high reproducibility for matrix elements that are expected to be present in similar concentrations. On the other hand elements that showed strong differences in their concentration in the feedstock were also represented by a higher concentration in the flue gas. Following the temporal variations of different elements revealed strong correlations between a number of elements, such as chlorine with sodium, potassium and zinc, as well as arsenic with lead, and calcium with strontium.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Microwave-Assisted Synthesis of Perovskite SrSnO 3 Nanocrystals in Ionic Liquids for Photocatalytic Applications

Nanosized SrSnO 3 photocatalysts have been successfully synthesized by microwave synthesis in various ionic liquids (ILs) followed by a heat treatment process to optimize the materials’ crystallinity. The influence of the ILs with various cations such as 1-butyl-3-methylimidazolium ([C 4 mim] + ), 6-bis(3-methylimidazolium-1-yl)hexane ([C 6 (mim) 2 ] 2+ ), butylpyridinium ([C 4 Py] + ), and tetradecyltrihexylphosphonium ([P 66614 ] + ) and bis(trifluoromethanesulfonyl)amide ([Tf 2 N] - ) as the anion on the structure, crystallization, and morphology of the products was investigated. The samples were characterized by X-ray diffraction (XRD), thermogravimetry (TG), scanning electron microscopy (SEM), surface area analysis by gas adsorption, X-ray photoelectron spectroscopy (XPS), diffuse reflectance UV–vis spectroscopy, and Raman and IR spectroscopy. According to structure characterization by XRD and Raman spectroscopy all samples crystallized phase-pure in the orthorhombic GdFeO 3 perovskite structure type. SEM reveals that, on the basis of the IL, the obtained SrSnO 3 nanoparticles exhibit different morphologies and sizes. Rod-shaped particles are formed in [C 4 mim][Tf 2 N], [C 6 (mim) 2 ][Tf 2 N] 2 , and [P 66614 ][Tf 2 N]. However, the particle dimensions and size distribution vary depending on the IL and range from quite thin and long needlelike particles with a narrow size distribution obtained in [P 66614 ][Tf 2 N] to relatively larger particles with a broader size distribution obtained in [C 6 (mim) 2 ][Tf 2 N] 2 . In contrast, in [C 4 Py][Tf 2 N] nanospheres with a diameter of about 50 nm form. For these particles the highest photocatalytic activity was observed. Our investigations indicate that the improved photocatalytic activity of this material results from the synergistic effect of the relatively large surface area associated with nanosize and an appropriate energy band structure.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Hollow fiber mid-ID spectrometer with UV laser ablation sampling for fine spatial reoslution of isotope ratios in solids

We describe a system that combines isotope ratio analysis via mid-infrared (Mid-IR) laser absorption spectroscopy with fine spatial resolution sampling using a UV pulsed laser. The UV laser ablates a pit in a solid on the order of 10 microns in diameter. The sample-derived particulates resulting from laser ablation pass through a micro-combustor, and the resulting gas is analyzed using Mid-IR laser absorption spectroscopy in a capillary absorption spectrometer (CAS). The CAS uses a hollow fiber optic waveguide with a reflective inner coating and a small internal volume on the order of 1ml. The hollow fiber both guides the laser light from source to detector and contains the gas sample at reduced pressure. Near unity overlap between the laser beam and sample enables sensitive analysis with ultra-small sample size. A prototype system has been demonstrated to enable stable carbon isotopic analysis (d13C) with 1 per mil precision using <1 picomole of carbon and is currently being used to study nutrient exchange in soil/root/microbial rhizosphere studies. The smaller sample size of this system is enabling fine spatial resolution analysis (on the order of 10 microns), which is roughly an order of magnitude smaller than was possible with an isotope ratio mass spectrometer (IRMS). In addition to rhizosphere studies, the system can provide a useful tool for fine scale isotope analysis with applications in biological, forensic, and environmental science.

capillary absorption spectroscopy, laser ablation,↗

Analysis, identification and confirmation of synthetic opioids using chloroformate chemistry: Retrospective detection of fentanyl and acetylfentanyl in urine and plasma samples by EI-GC-MS and HR-LC-MS

Electron Impact Gas Chromatography-Mass Spectrometry (EI-GC-MS) and High Resolution Liquid Chromatography-Mass Spectrometry (HR-LC-MS) have been used in the analysis of products arising from the trichloroethoxycarbonylation of fentanyl and acetylfentanyl in urine and plasma matrices. The method involves the initial extraction of both synthetic opioids separately from the matrices followed by detection of the unique products that arise from their reaction with 2,2,2-trichloroethoxycarbonyl chloride (Troc-Cl), namely Troc-norfentanyl and Troc-noracetylfentanyl. The optimized protocol was successfully evaluated for its efficacy at detecting these species formed from fentanyl and acetylfentanyl when present at low and high levels in urine (fentanyl: 5 and 10 ng/mL and acetylfentanyl: 20 and 100 ng/mL) and plasma (fentanyl: 10 and 20 ng/mL and acetylfentanyl: 50 and 200 ng/mL), values that reflect levels reported in overdose victims. The HR-LC-MS method’s LOQ (limit of quantitation) for the Troc-norfentanyl and Troc-noracetylfentanyl products was determined to be ~10 ng/mL for both species. Even though the superiority in the detection of these species by HR-LC-MS over EI-GC-MS, the latter method proved to be important in the detection of the second product from the reaction, namely 2-phenylethyl chloride that is crucial in the determination of the original opioid. This observation highlights the importance of using complimentary analytical techniques in the analysis of a sample, whether biological or environmental in nature. The method herein serves as a complementary, qualitative confirmation for the presence of a fentanyl in collected urine, plasma and by extension other biological samples amenable to the common extraction procedures described for opioid analysis. More importantly, the method’s main strength comes from its ability to react with unknown fentanyls to yield products that can be not only detected by EI-GC-MS and HR-LC-MS but can then be used to retrospectively identify an unknown fentanyl.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗