Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “GaGe”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Strain Gage

HITEC Corporation developed a strain gage application for DanteII, a mobile robot developed for NASA. The gage measured bending forces on the robot's legs and warned human controllers when acceptable forces were exceeded. HITEC further developed the technology for strain gage services in creating transducers out of "Indy" racing car suspension pushrods, NASCAR suspension components and components used in motion control.

Source record↗

Fiber-Optic Strain-Gage Tank Level Measurement System for Cryogenic Propellants

Measurement of tank level, particularly for cryogenic propellants, has proven to be a difficult problem. Current methods based on differential pressure, capacitance sensors, temperature sensors, etc.; do not provide sufficiently accurate or robust measurements, especially at run time. These methods are designed to measure tank-level, but when the fluids are in supercritical state, the liquid-gas interface disappears. Furthermore, there is a need for a non-intrusive measurement system; that is, the sensors should not require tank modifications and/or disturb the fluids. This paper describes a simple, but effective method to determine propellant mass by measuring very small deformations of the structure supporting the tank. Results of a laboratory study to validate the method, and experimental data from a deployed system are presented. A comparison with an existing differential pressure sensor shows that the strain gage system provides a much better quality signal across all regimes during an engine test. Experimental results also show that the use of fiber optic strain gages (FOSG) over classic foil strain gages extends the operation time (before the system becomes uncalibrated), and increases accuracy. Finally, a procedure is defined whereby measurements from the FOSG mounted on the tank supporting structure are compensated using measurements of a FOSG mounted on a reference plate and temperature measurements of the structure. Results describing the performance of a deployed system that measures tank level during propulsion tests are included.

Figueroa, Fernando↗

Theory and Practice of Shear/Stress Strain Gage Hygrometry

Mechanical hygrometry has progressed during the last several decades from crude hygroscopes to state-of-the art strain-gage sensors. The strain-gage devices vary from different metallic beams to strain-gage sensors using cellulose crystallite elements, held in full shear restraint. This old technique is still in use but several companies are now actively pursuing development of MEMS miniaturized humidity sensors. These new sensors use polyimide thin film for water vapor adsorption and desorption. This paper will provide overview about modern humidity sensors.

Shams, Qamar A.↗

Experimental and Numerical Characterization of Transient Insertion of Heat Flux Gages in a Cylindrical Black Body Cavity at 1100 C

Initial transient thermal models have been developed to simulate a heat flux gage calibration process capable of generating high heat flux levels of interest to reciprocating and gas turbine engine industries as well as the aerospace industry. These transient models are based on existing, experimentally validated, steady state models of the cylindrical blackbody calibration system. The steady state models were modified to include insertion of a heat flux gage into the hot zone of the calibration system and time varying electrical current passing through the resistance heated blackbody. Heat fluxes computed using the initial transient models were compared to experimental measurements. The calculated and measured transient heat fluxes were within 5% indicating that the major physical phenomena in the transient calibration had been captured by the models. The predicted and measured transient heat fluxes were also compared at two different gage insertion depths. These results indicated that there is an optimum insertion position which maximizes heat flux and minimizes cavity disturbance.

Abdelmessih, A. N.↗

Comparison of Iterative and Non-Iterative Strain-Gage Balance Load Calculation Methods

The accuracy of iterative and non-iterative strain-gage balance load calculation methods was compared using data from the calibration of a force balance. Two iterative and one non-iterative method were investigated. In addition, transformations were applied to balance loads in order to process the calibration data in both direct read and force balance format. NASA's regression model optimization tool BALFIT was used to generate optimized regression models of the calibration data for each of the three load calculation methods. This approach made sure that the selected regression models met strict statistical quality requirements. The comparison of the standard deviation of the load residuals showed that the first iterative method may be applied to data in both the direct read and force balance format. The second iterative method, on the other hand, implicitly assumes that the primary gage sensitivities of all balance gages exist. Therefore, the second iterative method only works if the given balance data is processed in force balance format. The calibration data set was also processed using the non-iterative method. Standard deviations of the load residuals for the three load calculation methods were compared. Overall, the standard deviations show very good agreement. The load prediction accuracies of the three methods appear to be compatible as long as regression models used to analyze the calibration data meet strict statistical quality requirements. Recent improvements of the regression model optimization tool BALFIT are also discussed in the paper.

Ulbrich, N.↗

Detection of Bi-Directionality in Strain-Gage Balance Calibration Data

An indicator variable was developed for both visualization and detection of bi-directionality in wind tunnel strain-gage balance calibration data. First, the calculation of the indicator variable is explained in detail. Then, a criterion is discussed that may be used to decide which gage outputs of a balance have bi- directional behavior. The result of this analysis could be used, for example, to justify the selection of certain absolute value or other even function terms in the regression model of gage outputs whenever the Iterative Method is chosen for the balance calibration data analysis. Calibration data of NASA s MK40 Task balance is analyzed to illustrate both the calculation of the indicator variable and the application of the proposed criterion. Finally, bi directionality characteristics of typical multi piece, hybrid, single piece, and semispan balances are determined and discussed.

Ulbrich, Norbert↗

A Universal Tare Load Prediction Algorithm for Strain-Gage Balance Calibration Data Analysis

An algorithm is discussed that may be used to estimate tare loads of wind tunnel strain-gage balance calibration data. The algorithm was originally developed by R. Galway of IAR/NRC Canada and has been described in the literature for the iterative analysis technique. Basic ideas of Galway's algorithm, however, are universally applicable and work for both the iterative and the non-iterative analysis technique. A recent modification of Galway's algorithm is presented that improves the convergence behavior of the tare load prediction process if it is used in combination with the non-iterative analysis technique. The modified algorithm allows an analyst to use an alternate method for the calculation of intermediate non-linear tare load estimates whenever Galway's original approach does not lead to a convergence of the tare load iterations. It is also shown in detail how Galway's algorithm may be applied to the non-iterative analysis technique. Hand load data from the calibration of a six-component force balance is used to illustrate the application of the original and modified tare load prediction method. During the analysis of the data both the iterative and the non-iterative analysis technique were applied. Overall, predicted tare loads for combinations of the two tare load prediction methods and the two balance data analysis techniques showed excellent agreement as long as the tare load iterations converged. The modified algorithm, however, appears to have an advantage over the original algorithm when absolute voltage measurements of gage outputs are processed using the non-iterative analysis technique. In these situations only the modified algorithm converged because it uses an exact solution of the intermediate non-linear tare load estimate for the tare load iteration.

balance calibration analysis↗

Assessment of the Uniqueness of Wind Tunnel Strain-Gage Balance Load Predictions

A new test was developed to assess the uniqueness of wind tunnel strain-gage balance load predictions that are obtained from regression models of calibration data. The test helps balance users to gain confidence in load predictions of non-traditional balance designs. It also makes it possible to better evaluate load predictions of traditional balances that are not used as originally intended. The test works for both the Iterative and Non-Iterative Methods that are used in the aerospace testing community for the prediction of balance loads. It is based on the hypothesis that the total number of independently applied balance load components must always match the total number of independently measured bridge outputs or bridge output combinations. This hypothesis is supported by a control volume analysis of the inputs and outputs of a strain-gage balance. It is concluded from the control volume analysis that the loads and bridge outputs of a balance calibration data set must separately be tested for linear independence because it cannot always be guaranteed that a linearly independent load component set will result in linearly independent bridge output measurements. Simple linear math models for the loads and bridge outputs in combination with the variance inflation factor are used to test for linear independence. A highly unique and reversible mapping between the applied load component set and the measured bridge output set is guaranteed to exist if the maximum variance inflation factor of both sets is less than the literature recommended threshold of five. Data from the calibration of a six{component force balance is used to illustrate the application of the new test to real-world data.

strain-gage balance↗

Comparison of Two Load Prediction Methods for Strain-Gage Balances

Data from a high-capacity semi-span balance is used to perform a detailed comparison of the load prediction accuracy of two strain-gage balance load prediction methods. Both methods independently obtain their load prediction equations from multivariate least squares fits of balance calibration data. The first method is called Non-Iterative Method. This approach directly uses regression models of the individual load components of a balance for the load prediction. The second method is called Iterative Method. This alternate approach uses a load iteration equation for the load prediction that is constructed from the regression models of the gage outputs of the balance. Basic characteristics of the two methods are reviewed. Afterwards, both methods are applied to calibration and check load data of the chosen balance. Finally, selected analysis results are compared. These comparisons confirmed that the load prediction accuracy of the two methods is the same for all practical purposes.

wind tunnel test↗

Graphical and Numerical Description of Strain-Gage Balance Interactions

A new approach for the graphical and numerical description of strain-gage balance interactions is presented. The approach uses data from single-component loads as input. This choice has the two advantages. First, the number of applied loads is at the minimum needed for interactions to be observed. In addition, the loads used for the description of interactions can easily be repeated at different sites. Output differences relative to the outputs of the zero load point of a load series are used for the description of interactions. Similarly, load differences relative to the loads of the zero load point of a load series are used for the description of the loads. Interactions are plotted versus the load differences for each load component while omitting outputs of the primary gage of the chosen load component. The resulting plots have a star pattern as all interactions are zero at zero load. Estimates of the slopes of the interactions can be obtained from the load prediction equations of a balance if calibration data is examined. The slopes are the off-diagonal coefficients of the inverse of the matrix that has the coefficients of the linear terms of the fitted loads if the Non-Iterative Method is used for the analysis. Similarly, the slopes are the off-diagonal coefficients of the inverse of the matrix that is the non-iterative part of the primary load iteration equation if the Iterative Method is used for the analysis. Data sets from a manual and a machine calibration of a force balance are processed to illustrate the proposed description of interactions.

strain-gage balance↗

Precision gage measures ultrahigh vacuum levels

Ionization gage in which internally generated X rays are minimized is described. This gage permits the measurement of gas pressures in ultrahigh systems of micro-pico torr /10-18/.

Hudson, J. B.↗

Cold cathode ionization gage has rigid metal housing

Cold cathode ionization gage in a stainless steel housing accurately measures high pressures. The penning effect is used with a high voltage discharge in the presence of a magnetic field for an ion current proportional to the gas pressure in the gage.

Herzog, R.↗

Rod and dish cathode improves penning-type vacuum gage

Improved penning-type ionization gage provides range and sensitivity required to measure gas pressure below .01 torr under high vacuum conditions. The gage uses a highly conductive cathode composed of two disks of high magnetic permeability separated by a rod of low magnetic permeability.

Peppin, G. B.↗

Thin-film gage measures low heat-transfer rates

Low heat-transfer gage facilitates determination of the transition between laminar and turbulent conditions, in the boundary layer surrounding slender and moderately slender cones under test in a hypersonic blowdown helium tunnel. The gage consists of a thin layer of vacuum-evaporated platinum on a heat resistant glass substrate contoured to fit model surfaces.

Spitzer, C. R.↗

Modified McLeod pressure gage eliminates measurement errors

Modification of a McLeod gage eliminates errors in measuring absolute pressure of gases in the vacuum range. A valve which is internal to the gage and is magnetically actuated is positioned between the mercury reservoir and the sample gas chamber.

Kells, M. C.↗

Holding fixture facilitates pipe thread gage measurements

Holding fixture that holds the thread gage and three wires in the proper relationship facilitates the measurement of the pitch diameter of the tapered threads of a pipe thread gage. Modified, this device can be used to hold involute spur gears.

Cupps, B.↗

Gage monitors quality of cross-wire resistance welds

Gage nondestructively monitors the quality of cross-wire resistance welds during the welding operation. The gage gives a dial indication of the relative embedment of the cross wires during the actual welding operation. A direct relationship exists between the depth of embedment and both weld strength and consistency.

Etzel, J.↗