Evaluation of Low Environmental Impact Distributed Scroll Booster Technology for Supermarket Refrigeration

A distributed scroll booster refrigeration system is proposed as an alternative for current refrigeration systems used in supermarket applications. The distributed scroll booster system is configured to enable the use of low-pressure refrigerants such as R-1234yf, which has a global warming potential (GWP) of less than 1, in a cycle configuration that employs a two-stage compression process. This scroll booster system is comprised of medium-temperature compressors (high stage) coupled with low-temperature compressors (low stage). This two-stage system architecture allows both low-temperature and medium-temperature refrigerated display cases to be integrated in the same system. By design, this system reduces the refrigerant charge, produces higher efficiencies (two-stage compression), uses existing components minimizing cost impact, and will be able to use ultra-low GWP class A2L (low toxicity and low flammability) refrigerants such as R-1234yf when standards and building codes are updated (expected by 2025).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Eliminating the Need for Refrigerants Using New Liquid and Salt-Based Cooling and Heat-Pumping Technology (CRADA Final Report)

Calion Technologies, Inc. project team investigated various embodiments of the ionocaloric cycle. Ionocaloric technology provides a new platform for all heating and cooling that is zero-GWP, non-toxic, non-hazardous, and non-flammable. It is well-poised to replace vapor compression technology which uses high-GWP refrigerants which are on track to account for 25% of our global warming budget. Developing the ionocaloric technology as a drop-in replacement for vapor compression was the primary research thrust under this CRADA.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Industry Scan of Non-SF6 Gas-Insulated Technologies

Sulfur Hexafluoride (SF 6 ) is a specialty gas with excellent electrical insulation properties which has been used extensively in the power industry. This gas is unfortunately also one of the most potent greenhouse gases known to humanity. A 2014 report by the Intergovernmental Panel on Climate Change found that SF 6 has a global warming potential (GWP) 23,000 times higher than Carbon Dioxide, and has the highest GWP of all gases assessed (Myhre 2013). SF 6 is almost exclusively man-made and is produced for use as an insulator in high voltage electrical equipment. This makes the production and use of SF 6 one of the leading sources of anthropogenic climate change. Since SF 6 recognition as a significant contributor to climate change, most governments and organizations have sought ways to reduce or eliminate their use of this gas. Many utilities have initiated leak monitoring and repair programs which have significantly reduced emissions of this gas into the atmosphere. While leak reduction programs have been effective at reducing emission rates in the developed world, leak rates remain frozen at ~1% annually. However, one of the largest and fastest growing markets for this gas is in the developing world where emissions standards are often lacking (P&S Intelligence. 2023). To fully eliminate the environmental impacts of SF 6 , alternative technology is needed. The ideal replacement would be a technology that can fulfil the same role as SF 6 , at the same cost or cheaper, but without adverse environmental effects. Currently, no technology fits this description, however several promising technologies have begun to enter the market. This report was commissioned by the United States Department of Energy’s Office of Electricity under the Transformer Resilience and Advanced Components (TRAC) program to assess the state of industry adoption and manufacturing capability for SF 6 -free alternative technologies for use at the high-voltage level, and the primary barriers to broader adoption. While this report is tailored to the United States, the findings should be relevant to all stakeholders seeking to reduce SF 6 emissions.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

Subtask 1.22 - Microbial Cycling of CH4, CO2, and N2O in a Wetlands Environment

Soil microbial metabolic activities play an important role in determining CO{sub 2}, CH{sub 4}, and N{sub 2}O fluxes from terrestrial ecosystems. To verify and evaluate CO{sub 2} sequestration potential by wetland restoration in the Prairie Pothole Region (PPR), as well as to address concern over restoration effects on CH{sub 4} and N{sub 2}O emissions, laboratory and in situ microcosm studies on microbial cycling of CO{sub 2}, CH{sub 4}, and N{sub 2}O were initiated. In addition, to evaluate the feasibility of the use of remote sensing to detect soil gas flux from wetlands, a remote-sensing investigation was also conducted. Results of the laboratory microcosm study unequivocally proved that restoration of PPR wetlands does sequester atmospheric CO{sub 2}. Under the experimental conditions, the simulated restored wetlands did not promote neither N{sub 2}O nor CH{sub 4} fluxes. Application of ammonia enhanced both N{sub 2}O and CH{sub 4} emission, indicating that restoration of PPR wetlands may reduce both N{sub 2}O and CH{sub 4} emission by cutting N-fertilizer input. Enhancement of CO{sub 2} emission by the N-fertilizer was observed, and this observation revealed an overlooked fact that application of N-fertilizer may potentially increase CO{sub 2} emission. In addition, the CO{sub 2} results also demonstrate that wetland restoration sequesters atmospheric carbon not only by turning soil conditions from aerobic to anoxic, but also by cutting N-fertilizer input that may enhance CO{sub 2} flux. The investigation on microbial community structure and population dynamics showed that under the experimental conditions restoration of the PPR wetlands would not dramatically increase population sizes of those microorganisms that produce N{sub 2}O and CH{sub 4}. Results of the in situ study proved that restoration of the PPR wetland significantly reduced CO{sub 2} flux. Ammonia enhanced the greenhouse gas emission and linearly correlated to the CO{sub 2} flux within the experimental rate range (46-200 kg N ha{sup -1}). The results also clarified that the overall reduction in global warming potential (GWP) by the PPR wetland restoration was mainly contributed from reduction in CO{sub 2} flux. These results demonstrate that restoration of currently farmed PPR wetlands will significantly reduce the overall GWP budget. Remote sensing investigations indicate that while the 15-meter resolution of the imagery was sufficient to delineate multiple zones in larger wetlands, it was not sufficient for correlation with the ground-based gas flux measurement data, which were collected primarily for smaller wetland sites (<250 meters) in the areas evaluated by this task. To better evaluate the feasibility of using satellite imagery to quantify wetland gas flux, either higher-resolution satellite imagery or gas flux data from larger wetland sites is needed.

54 ENVIRONMENTAL SCIENCES↗

Heat Transfer, Refrigeration and Heat Pumps

The Special Issue entitled “Heat Transfer, Refrigeration and heat Pumps” accepted papers covering a wide range of topics related to heat pumps, thermal energy storage, and low-Global Warming Potential (GWP) alternative refrigerants. Heat pumps play a vital role in providing space conditioning and water heating while utilizing the energy of the environment. Since heat pumps use renewable thermal energy from the environs to provide the desired utility, they contribute to the portfolio of technologies that mitigate carbon footprint. The heat pump may be considered a truly renewable technology if the electricity it uses comes entirely from a renewable source. More accurately, a heat pump is a “low carbon technology”. These perspectives make heat pumps an indispensable option for the future in order to reduce the nocuous human impact on the environment. More efficient heat pumping technologies are being developed for the residential, commercial, and industrial sectors of the economy. Another R&D thrust is heat pumps for cold climates. Hardware components, use of low-GWP refrigerants, and identification of systemic inefficiencies are active research areas. This article is a synopsis of the papers submitted to the Special Issue.

42 ENGINEERING↗

Life Cycle Assessment of Bioethanol Production: A Case Study from Poplar Biomass Growth in the U.S. Pacific Northwest

Biomass appears to be one of the most prominent renewable resources for biofuels such as bioethanol, mainly due to its better environmental performance compared with fossil fuels. This study addresses a comprehensive environmental performance of bioethanol production, employing empirical data from hybrid poplar grown in the U.S. The study considers 1 MJ as a functional unit and employs a cradle-to-grave approach, which entails the feedstock and harvesting production of poplar, transport to a biorefinery, bioconversion of the biomass process, and fuel use. On average, bioconversion is the main contributor to environmental degradation in all the categories evaluated (77%). The second main contributor is either the feedstock and harvesting production of poplar (17%) or fuel use (6%), depending on the environmental category. Thus, focusing on only one category may induce a misinterpretation of the environmental performance of bioethanol production. Finally, environmental credits in the global warming potential (GWP) category were obtained from the carbon sequestered in the biomass during the growing period and from avoided fossil fuel emissions due to electricity production from a renewable source. This means that the net GWP of the life cycle of bioethanol from poplar biomass is slightly negative (–1.05 × 10 –3 kg CO 2 -eq·MJ –1 ).

09 BIOMASS FUELS↗

The Influence of Ozone Precursor Emissions from Four World Regions on Tropospheric Composition and Radiative Climate Forcing

Ozone (O3) precursor emissions influence regional and global climate and air quality through changes in tropospheric O3 and oxidants, which also influence methane (CH4) and sulfate aerosols (SO4 (sup 2-)). We examine changes in the tropospheric composition of O3, CH4, SO4 (sup 2-) and global net radiative forcing (RF) for 20% reductions in global CH4 burden and in anthropogenic O3 precursor emissions (NOx, NMVOC, and CO) from four regions (East Asia, Europe and Northern Africa, North America, and South Asia) using the Task Force on Hemispheric Transport of Air Pollution Source-Receptor global chemical transport model (CTM) simulations, assessing uncertainty (mean plus or minus 1 standard deviation) across multiple CTMs. We evaluate steady state O3 responses, including long-term feedbacks via CH4. With a radiative transfer model that includes greenhouse gases and the aerosol direct effect, we find that regional NOx reductions produce global, annually averaged positive net RFs (0.2 plus or minus 0.6 to 1.7 2 mWm(sup -2)/Tg N yr(sup -1), with some variation among models. Negative net RFs result from reductions in global CH4 (-162.6 plus or minus 2 mWm(sup -2) for a change from 1760 to 1408 ppbv CH4) and regional NMVOC (-0.4 plus or minus 0.2 to 0.7 plus or minus 0.2 mWm(sup -2)/Tg C yr(sup -1) and CO emissions (-0.13 plus or minus 0.02 to -0.15 plus or minus 0.02 mWm(sup-2)/Tg CO yr(sup-1). Including the effect of O3 on CO2 uptake by vegetation likely makes these net RFs more negative by -1.9 to- 5.2 mWm(sup -2)/Tg N yr(sup -1), -0.2 to -0.7 mWm(sup -2)/Tg C yr(sup -1), and -0.02 to -0.05 mWm(sup -2)/ Tg CO yr(sup -1). Net RF impacts reflect the distribution of concentration changes, where RF is affected locally by changes in SO4 (sup -2), regionally to hemispherically by O3, and globally by CH4. Global annual average SO4 2 responses to oxidant changes range from 0.4 plus or minus 2.6 to -1.9 plus or minus 1.3 Gg for NOx reductions, 0.1 plus or minus 1.2 to -0.9 plus or minus 0.8 Gg for NMVOC reductions, and -0.09 plus or minus 0.5 to -0.9 plus or minus 0.8 Gg for CO reductions, suggesting additional research is needed. The 100-year global warming potentials (GWP(sub 100)) are calculated for the global CH4 reduction (20.9 plus or minus 3.7 without stratospheric O3 or water vapor, 24.2 plus or minus 4.2 including those components), and for the regional NOx, NMVOC, and CO reductions (18.7 plus or minus 25.9 to 1.9 plus or minus 8.7 for NOx, 4.8 plus or minus 1.7 to 8.3 plus or minus 1.9 for NMVOC, and 1.5 plus or minus 0.4 to 1.7 plus or minus 0.5 for CO). Variation in GWP(sub 100) for NOx, NMVOC, and CO suggests that regionally specific GWPs may be necessary and could support the inclusion of O3 precursors in future policies that address air quality and climate change simultaneously. Both global net RF and GWP100 are more sensitive to NOx and NMVOC reductions from South Asia than the other three regions.

ozone↗

Model Analysis of the Factors Regulating Trends and Variability of Methane, Carbon Monoxide and OH: 1. Model Validation

Methane (CH4) is the second most important anthropogenic greenhouse gas (GHG). Its 100-year global warming potential (GWP) is 25 times larger than that for carbon dioxide. The 100-yr integrated GWP of CH4 is sensitive to changes in OH levels. Methane's atmospheric growth rate was estimated to be more than 10 ppb yr(exp -1) in 1998 but less than zero in 2001, 2004 and 2005 (Kirschke et al., 2013). Since 2006, the CH4 is increasing again. This phenomena is yet not well understood. Oxidation of CH4 by OH is the main loss process, thus affecting the oxidizing capacity of the atmosphere and contributing to the global ozone background. Current models typically use an annual cycle of offline OH fields to simulate CH4. The implemented OH fields in these models are typically tuned so that simulated CH4 growth rates match that measured. For future and climate simulations, the OH tuning technique may not be suitable. In addition, running full chemistry, multi-decadal CH4 simulations is a serious challenge and currently, due to computational intensity, almost impossible.

OH↗

Global benefits of non-continuous flooding to reduce greenhouse gases and irrigation water use without rice yield penalty

Non-continuous flooding is an effective practice for reducing greenhouse gas emissions (GHGs) and irrigation water use (IRR) in rice fields. However, advancing global implementation is hampered by the lack of comprehensive understanding of GHGs and IRR reduction benefits without compromising rice yield. Here, we present the largest observational data set for such effects as of yet. By using Random Forest regression models based on 636 field trials at 105 globally georeferenced sites, we identified the key drivers of effects of non-continuous flooding practices and mapped maximum GHGs or IRR reduction benefits under optimal non-continuous flooding strategies. The results show that variation in effects of non-continuous flooding practices are primarily explained by the UnFlooded days Ratio (UFR, that is the ratio of the number of days without standing water in the field to total days of the growing period). Non-continuous flooding practices could be feasible to be adopted in 76% of global rice harvested areas. This would reduce the global warming potential (GWP) of CH4 and N2O combined from rice production by 47% or the total GWP by 7% and alleviate irrigation water use by 25%, while maintaining yield levels. The identified UFR targets far exceed currently observed levels particularly in South and Southeast Asia, suggesting large opportunities for climate mitigation and water use conservation, associated with the rigorous implementation of non-continuous flooding practices in global rice cultivation.

climate change mitigation↗

Evaluating alternative refrigerants for high ambient temperature environments

According to the Montreal Protocol, developing countries have started the phase out schedule of the ozone depleting substances, including HCFC refrigerants, in 2015 and expect them to reach 35% reduction in 2020. This commitment to the start the phase out of HCFC refrigerants, especially R-22, in developing countries is seen as an opportunity to introduce lower Global Warming Potential (GWP) refrigerants. Furthermore, this paper summarizes an investigation into the performance of lower GWP refrigerants in high ambient temperature environments, experienced in some of the developed countries, in mini-split air conditioning units.

54 ENVIRONMENTAL SCIENCES↗

Reduced-order model to estimate safe flammable refrigerant charge limits for a one-room air conditioner

The Heating, Ventilation, Air-Conditioning and Refrigeration (HVAC&R) industry is currently transitioning away from high global warming potential (GWP) hydrofluorocarbon (HFC) refrigerants. However, many lower-GWP alternatives are flammable. Current safety codes restrict use of all flammable refrigerants; revision of the codes is needed to facilitate wider use of flammable alternatives. Hence, information is needed to enable reliable estimates of safe charge limits for flammable refrigerant options for different HVAC&R applications. A reduced-order model (ROM) was developed and validated to help estimate safe charge limits based on computational fluid dynamics (CFD) simulations of refrigerant releases in a single room for a range of parameters. Validation of the ROM vs. the CFD results showed good general agreement for mean refrigerant concentration. The normalized mean bias error (NMBE) was 0.67% with a maximum error of 15%.

Edwards, Dean↗

Characteristics of refrigerant leaks from small HVAC&R systems

Reduced use of high global warming potential (GWP) hydrofluorocarbon (HFC) refrigerants is desired. However, many lower-GWP alternatives are flammable, some of higher flammability levels, or A3, and others of lower flammability (A2 or A2L).Safety standards for A2 and A3 flammable refrigerants, including the International Electrotechnical Commission (IEC) standard IEC 60335-2-40 calculate maximum flammable refrigerant charge limits using a fixed 4-minute leak time based on the time to leak 150 g of CO2 through a capillary tube.Actual refrigerant leak times depend on the equipment type, leak location, leak orifice diameter and equipment operation condition (on or off).Five systems were installed in test chambers with leak quantities and rates measured by tracking total system weight during the leak event. Among the major results were that almost all of the system charge was shown to escape the units, >80% within the first 10 minutes.

Patel, Viral↗

Analysis of the P-T and T-S phase boundary in discriminating suitable low global warming potential and low flammability refrigerants

Although several alternative low GWP refrigerants including natural have been proposed, the HVAC industry consensus on how to deal with the attendant issues is still evolving. This paper provides a qualitative and quantitative insight into the peculiar phase boundary shapes of refrigerants, essential for understanding their application, and in evaluating existing and future refrigerants. The methodology is firmly grounded in the thermodynamics of phase equilibria and the criteria of positive-definiteness, a direct consequence of the Second Law and the existence of intermolecular forces (IMF). The formal methodology is strikingly easy to implement in practice and explains clearly why certain refrigerants display “re-entrant” behavior while others do not. The paper shows how an evidence-based selection can be made among the 40 refrigerants analyzed in this study. Keywords: Low GWP, alternate refrigerants, heat pumps, VLE

Ally, Moonis↗

Seismic Resilience of Large Power Transformer Bushings & Non-SF6 Industrial Base Scan Review

Large (high voltage) power transformers (LPT), and more specifically, their bushings, are known to be susceptible to seismic failure. With bushing failure, a transformer will have to be replaced, which has a considerable lead time, adding to the power outage duration. Cost-efficient, proven solutions are not currently available to mitigate this risk, which can persist for the more than 30-year life of a particular transformer. This work will focus on developing and demonstrating a hardware solution to address seismic vulnerabilities and reduce outage risks from LPT failure. Sulfur Hexafluoride (SF6) is a specialty gas with excellent electrical insulation properties which has been used extensively in the power industry. This gas is unfortunately also one of the most potent greenhouse gases known to humanity. A 2014 report by the Intergovernmental Panel on Climate Change found that SF6 has a global warming potential (GWP) 23,000 times higher than Carbon Dioxide, and has the highest GWP of all gases assessed (Myhre 2013). SF6 is almost exclusively man-made and is produced for use as an insulator in high voltage electrical equipment. This makes the production and use of SF6 one of the leading sources of anthropogenic climate change. To fully eliminate the environmental impacts of SF6, alternative technology is needed. The ideal replacement would be a technology that can fulfil the same role as SF6, at the same cost or cheaper, but without adverse environmental effects. Currently, no technology fits this description, however several promising technologies have begun to enter the market. An industry scan was performed to assess the state of industry adoption and manufacturing capability for SF6-free alternative technologies for use at the high-voltage level, and the primary barriers to broader adoption.

10 SYNTHETIC FUELS↗

Development of Methane Emissions Model to Assess Fuel Recovery Potential at Gas Well Sites Using On Site Compression

The U.S. natural gas production and consumption has increased 85.5% since 2005 primarily due to the unconventional production methods of horizontal drilling and hydraulic fracturing. Natural gas used as a fuel has a lower greenhouse gas (GHG) footprint than coal and petroleum due to lower Carbon Dioxide (CO2) emissions when combusted. However, the “greener” benefit to natural gas may be negated by leaks in production and transmission systems. Methane (CH4), the primary hydrocarbon in natural gas, has an estimated Global Warming Potential (GWP) of 28-36 over 100 years, meaning it can absorb 28-36 more energy than CO2 which has a GWP of 1.0. Natural gas well sites are prone to methane emissions, or leaks and irregular gas releases, vented to atmosphere throughout production and transmission. The U.S. Department of Energy (DOE) and the National Energy Technology Laboratory (NETL) has recently granted West Virginia University (WVU) funding under agreement DE-FOA-0002005, to “Advance technologies to mitigate methane emissions and increase the efficiency of the natural gas transportation infrastructure”. As part of this funding WVU was tasked with identifying and quantifying sources of methane emissions at unconventional well sites, processing this data, and developing a system to recapture these emissions. A 0-D Simulink model was developed, utilizing standardized methodologies, data from previously conducted studies, as well as collected data from well sites in the Marcellus shale play region. The model was developed to predict emission rates from various components at natural gas well sites as well as the potential to utilize these emissions as fuel for the natural gas powered compressor engines on-site. This model was utilized to run high, medium, and low cases for four identified emission sources, engine size, pneumatic controller count, liquid level production which dictates tank emissions, and compressor packing vent emissions. Due to discrepancies in transient tank emission data, a high and low emission factor for tanks was used, resulting in two sets of 81 executed cases, and 162 unique cases of total site emissions and potential for fuel consumption. Each of the cases were run over 86,400 seconds at a 1 Hz, representative of a full 24 hour day of operation. The fuel consumption offset an average of 557% of fuel consumption on an energy density basis across all 81 cases with the high tank emission factor with a maximum offset of 2334%. The fuel consumption offset was an average of 82.9% for all 81 cases with the low tank emission factor with a maximum offset of 337%. This study highlights flaws in the use of publicly available methane number calculations to determine natural gas’s suitability as an engine fuel as well as the lack of public data for transient liquid storage tank emissions.

03 NATURAL GAS↗

Energy Efficient and Sustainable HPC at Pacific Northwest National Laboratory

Power consumption in US data centers has been escalating at an alarming rate. In response to Public Law 109-431, EPA reported that electricity usage by US data centers accounted for 1.5% of the total electricity used in the US in 2006. They projected that if current data center operating practices continue, electricity usage will almost double to 2.9% of the total electricity used in the US in 2011 (EPA, 2007). Consequently EPA issued a call to action to both government and industry to collaborate and set aggressive goals to reduce power consumption in data centers. In the spirit of responding to the findings and recommendations of the EPA report, the Pacific Northwest National Laboratory (PNNL) has teamed with several key organizations including: The Green Grid (TGG), ASHRAE TC9.9, IBM, 3M, and SprayCool. As part of this effort, a highly instrumented liquid-cooled cluster has been installed at PNNL. The cluster is housed in an 800 ft2 data center which resides in a mixed-use data center with a significant amount of instrumentation as well. The eventual objective of the effort is to be able to report the real-time power consumption, energy efficiency, and productivity of the liquid-cooled data center. Preliminary results from the effort at PNNL are reported in this paper. Thermal results are reported for the hottest server components, including the microprocessors and memory DIMMs. Under all conditions tested, the components have not exceeded manufacturers’ specifications. More importantly, the data show that the liquid-cooled servers can be maintained within specifications while rejecting to non-chilled facility water at 78°F (25.6°C). Furthermore, a reasonable extrapolation suggests that the specifications can still be maintained at 86°F (30°C). In an effort to address global warming, work has started on the qualification of a new 3M Fluoroketone fluid that has a Global Warming Potential (GWP) of 1. This GWP is the lowest published value of all commercially available coolants. Details are provided in the body of this paper.

54 ENVIRONMENTAL SCIENCES↗

Experimental study of R452B and R454B as drop-in replacement for R410A in split heat pumps having tube-fin and microchannel heat exchangers

The objective of this study is to experimentally evaluate two residential split heat pumps using low-GWP refrigerants, i.e., R452B and R454B, and compare the results against R410A. In this work, each heat pump used the same model of two-speed scroll compressor, the same indoor blower and outdoor fan. However, they were distinguished by the indoor and outdoor heat exchanger types: tube-fin heat exchangers (TFHXs) in one case, and microchannel heat exchangers (MCHXs) in the other. The two heat pumps were extensively evaluated following the test conditions for two-speed SEER (cooling seasonal energy efficiency rating)/HSPF (heating seasonal performance factor) ratings.In general, these results show that R452B and R454B are good replacement candidates for R410A for heat pump using tube-fin heat exchangers and microchannel heat exchangers. R452B and R454B led to lower capacities. In the TFHX heat pump, on average, compared to the performance of R410A, the cooling capacity of R452B is 96%; the heating capacity of R452B is 91%; the cooling capacity of R454B is 95%, the heat capacity of R454B is 89%. In the MCHX heat pump, the cooling capacity of R452B is 97%; the heating capacity of R452B is 97%; the cooling capacity of R454B is 98%, the heat capacity of R454B is 97%. With respect to cooling and heating seasonal performances, in the TFHX heat pump, the SEERs of R452B and R454B are 1.5% lower than R410A. HSPFs of the three refrigerants are identical. In the MCHX heat pump, R454B has 7% higher SEER, and R452B has 2% higher SEER than R410A; in heating mode, R454B has the same HSPF as R410A, while R452B is 4% more efficient. The compressor lubricant overheating issue of R452B and R454B, at low ambient heating condition, high stage, should be noticed.

42 ENGINEERING↗

Model validations for low-global warming potential refrigerants in mini-split air-conditioning units

To identify low GWP (global warming potential) refrigerants to replace R-22 and R-410A, extensive experimental evaluations were conducted for multiple candidates of refrigerant at the standard test conditions and at high-ambient conditions with outdoor temperature varying from 27.8 C to 55.0 C.. In the study, R-22 was compared to propane (R-290), DR-3, ARM-20B, N-20B and R-444B in a mini-split air conditioning unit originally designed for R-22; R-410A was compared to R-32, DR-55, ARM-71A, L41-2 (R-447A) in a mini-split unit designed for R-410A. To reveal physics behind the measured performance results, thermodynamic properties of the alternative refrigerants were analysed. In addition, the experimental data was used to calibrate a physics-based equipment model, i.e. ORNL Heat Pump Design Model (HPDM). The calibrated model translated the experimental results to key calculated parameters, i.e. compressor efficiencies, refrigerant side two-phase heat transfer coefficients, corresponding to each refrigerant. As a result, these calculated values provide scientific insights on the performance of the alternative refrigerants and are useful for other applications beyond mini-split air conditioning units.

54 ENVIRONMENTAL SCIENCES↗