Computational Fluid Dynamics (CFD) Analyses of a Glovebox under Glove Loss Conditions
Abstract not provided
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Abstract not provided
Abstract not provided.
To accelerate nuclear fuel qualification and deployment efforts, Oak Ridge National Laboratory has led the world in developing vehicles for accelerating burnup accumulation in nuclear fuel by testing miniature samples in the High Flux Isotope Reactor. However, a challenge remains to establish parity between post irradiation characterization methods for miniature fuel specimens in comparison to conventional fuel elements. This work aims to identify artifacts associated with the thermal analysis of miniature disk specimens in comparison to samples of standardized dimensions through a combination of experimental and computational tools. Using a newly procured Netzsch 427 laser flash diffusivity system, preliminary data on mild steel specimens were collected, and finite element techniques were used to model heat transfer using 1D conditions to assess issues associated with pulse width and data collection frequency effects. These preliminary investigations found that significant variability in measured thermal diffusivity exist within datasets. These variations are not necessarily attributed to limitations with respect to data collection rate; nor are they associated with limitations on pulse width. Instead, these artifacts may be a result of limitations in detector intensity. Future work aims to design a focusing lens to better measure the smaller surface area of miniature specimens analyzed using the laser flash analysis system.
The results of the experiments presented above are summarized in Table 1. Timing of critical events, such as appearance of bubbles on the specimen surface and rupture are noted. Relevant temperature and pressure data are also summarized. These results indicate a few critical aspects of the response of Hypalon glove material when exposed to a high temperature environment. Glove specimens began to show changes in surface appearance (appearance of bubbles on surface) when the temperature at the specimen surface was 530 ± 32 °F, regardless of specimen thickness. The bubbles are likely the result of the glove material decomposing and off-gassing. In the case of the 15 mil thickness gloves, specimens ruptured shortly after bubbling was observed. The ruptures are likely the result the bubbles growing in size, eventually forming pinholes through the thickness of the specimen. It should be noted that the specimens did not need to ignite in order to cause a perforation of the specimen. Specimens located 10, 11 and 12 inches from the burner ruptured, while the specimen located 14 inches from the burner did not rupture; in fact no change in surface appearance was observed. The 30 mil thickness specimens exhibited a different post-bubble response with only the specimen located 10 inches from the burner (i.e. highest surface temperature) resulting in rupture. There was a longer delay between surface bubbling and rupture than was observed in the 15 mil thickness specimens. This specimen also ignited before the specimen ruptured. While the 30 mil thickness specimens located 11 and 12 inches from the burner did show surface bubbling corresponding to thermal breakdown, neither specimen ruptured. Examination of the specimens after testing revealed that a slightly hard layer of melted material had formed on the rear of the specimen. This layer may have acted to seal the rear surface of the specimen by forming a barrier that bubbles could not penetrate. The specimen located 14 inches from the burner did not rupture, and did not exhibit any change in surface characteristics. In general the 30 mil thickness glove materials proved more resistant to thermal-induced rupturing as compared with the 15 mil thickness glove material. It was shown to be possible to rupture a 15 mil thick glove without igniting the glove, while the only test case that resulted in a rupture of a 30 mil thickness specimen also showed the specimen igniting several seconds before eventual rupture. Furthermore, it was observed that 30 mil thickness specimens could be exposed to temperatures high enough to cause decomposition (bubbling), yet not rupture. Thus, it is possible that the 30 mil gloves rupture by burning through the specimen material, while the 15 mil thickness specimens could be ruptured by small bubbles formed by thermal off-gassing expanding and causing pinholes through the specimen thickness. We also note that thermal decomposition and the appearance of surface bubbles was observed in all experiments with a maximum temperature exceeding ∼500 °F. Lastly, we can state that specimens subjected to temperatures below 400 °F experienced no thermal damage, staying below this threshold should prevent damage and potential rupture of either thickness glove materials.
Explore the source record for details and available documents.
Three simple experiments, namely, Marangoni convection in closed containers (MCCC), fiber pulling in microgravity, and stability of a double float zone are described which were conducted during the U.S. Microgravity Laboratory mission (USML) in July 1992. Results show that, in the MCCC experiment, there was no evidence of partial wetting between the liquid and the walls either in the wetting or nonwetting configuration. In the nonwetting system, the void formed a hemispherical bubble that remained pinned to the walls with considerable contact line resistance. Significant differences were observed in the ability to pull liquid strings in low gravity in those materials which readily form liquid strands in normal gravity and do not necessarily form strands in reduced gravity. The double float zone configuration appeared to be quite stable in both cylindrical and sheet form.
The passive accelerometer system (PAS) is a simple moving ball accelerometer capable of measuring the small magnitude steady relative acceleration that occurs in a low earth orbit spacecraft due to atmospheric drag and the earth's gravity gradient. The accelerometer can be used when the spacecraft continuously rotates during the orbit such that some line of reference in the craft always points along the vector connecting the earth's mass center with the spacecraft mass center. PAS was used successfully on the first United States Microgravity Laboratory (USML-1).
The vibratory conveyor, routinely employed for normal-gravity transport of granular materials, usually consists of a continuous open trough vibrated sinusoidally to induce axial movement of a granular material. Motivated in part by a hypothetical application in zero gravity, we propose a novel modification of the vibratory conveyor based on a closed 2d trough operating in a "slide-conveying" mode, with the granular mass remaining permanently in contact with the trough walls. We present a detailed analysis of the mechanics of transport, based on a rigid-slab model for the granular mass with frictional (Coulomb) slip at the upper and lower walls. The form of the vibration cycle plays a crucial role, and the optimal conveying cycle is not the commonly assumed rectilinear sinusoidal motion. The conveying efficiency for the novel slide conveyor will be presented for several simple vibration cycles, including one believed to represent the theoretical optimum.
Porosity in the form of "bubbles and pipes" can occur during controlled directional solidification processing of metal alloys. It is detrimental to material properties and precludes obtaining meaningful scientific results. On Earth, density differences allow an initiated bubble can rise through the liquid and "pop" at the surface resulting in a sound casting. This is not likely to occur in a microgravity environment and, unfortunately, a number of experiments conducted in microgravity have suffered from porosity effects. The current investigation is a systematic effort towards understanding porosity formation and mobility during controlled directional solidification in a microgravity environment. This will be investigated by utilizing a transparent material, succinonitrile (SCN), in conjunction with a translating temperature gradient stage so that direct observation and recording of pore generation and mobility can be made. The talk will cover the porosity problem, the details of the proposed experiments and the experimental hardware, and the expectations from the microgravity experiments.
A new method for initiating nucleation from solutions in microgravity which avoids nucleation on container walls and other surfaces is described. This method consists of injecting a small quantity of highly concentrated, heated solution into the interior of a lightly supersaturated, cooler host gowth solution. It was tested successfully on USML-I, producing a large number of LAP crystals whose longest dimension averaged 1 mm.
No abstract available
No abstract available
For the first time on ISS, BASS-II utilized MSG working volume dilution with gaseous nitrogen (N2). We developed a perfectly stirred reactor model to determine the N2 flow time and flow rate to obtain the desired reduced oxygen concentration in the working volume for each test. We calibrated the model with CSA-CP oxygen readings offset using the Mass Constituents Analyzer reading of the ISS ambient atmosphere data for that day. This worked out extremely well for operations, and added a new vital variable, ambient oxygen level, to our test matrices. The main variables tested in BASS-II were ambient oxygen concentration, ventilation flow velocity, and fuel type, thickness, and geometry. BASS-II also utilized the on-board CSA-CP for oxygen and carbon monoxide readings, and the CDM for carbon dioxide readings before and after each test. Readings from these sensors allow us to evaluate the completeness of the combustion. The oxygen and carbon dioxide readings before and after each test were analyzed and compared very well to stoichiometric ratios for a one step gas-phase reaction. The CO versus CO2 followed a linear trend for some datasets, but not for all the different geometries of fuel and flow tested. Lastly, we calculated the heat release rates during each test from the oxygen consumption and burn times, using the constant 13.1 kJ of heat released per gram of oxygen consumed. The results showed that the majority of the tests had heat release rates well below 100 Watts.
Explore the source record for details and available documents.
Explore the source record for details and available documents.