Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “GAS CHROMATOGRAPHY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Analysis of chemical components from plant tissue samples

Information is given on the type and concentration of sterols, free fatty acids, and total fatty acids in plant tissue samples. All samples were analyzed by gas chromatography and then by gas chromatography-mass spectrometry combination. In each case the mass spectral data was accumulated as a computer printout and plot. Typical gas chromatograms are included as well as tables describing test results.

Laseter, J. L.↗

Analysis of Mixed Aryl/Alkyl Esters by Pyrolysis Gas Chromatography-Mass Spectrometry in the Presence of Perchlorate

Mars is an important target for Astrobiology. A key goal of the MSL mission was to determine whether Mars was habitable in the past, a que-tion that has now been definitely determined to be yes. Another key goal for Mars exploration is to understand the origin and distribution of organic material on Mars; this question is being addressed by the SAM instrument on MSL, and will also be informed by two upcoming Mars exploration missions, ExoMars and Mars 2020. These latter two missions have instrumentation capable of detecting and characterize organic molecules. Over the next decade, these missions will analyze organics in surface, near-surface and sub-surface samples. Each mission has the capability to analyze organics by different methods (pyrolysis gas chromatography-mass spectrometry [py-GC-MS]; laser desorption and thermal volatilization GC-MS; and Raman spectroscopy). Plausibly extraterrestrial organics were recently discovered by the Mars Science Laboratory (MSL), providing an important first step towards understanding the organic inventory on Mars [1]. The compounds detected were chlorobenzenes and chloroalkanes, but it was argued that chlorination of these compounds occurred during pyrolysis of samples containing unchlorinated organics in the presence of perchlorate. A recent report analyzed a suite of aromatic (benzene, toluene, benzoic acid, phthalic acid, and mellitic acid) and aliphatic (acetic acid, propane, propanol, and hexane) by pyrolysis under SAM-like conditions in the presence of perchlorate to attempt to constrain possible precursor molecules for the organic molecules detected on Mars. For aromatic compounds, the aromatic acids all readily produced SAM-relevant chlorobenzes, whereas benzene and toluene did not. This observation suggests that the chlorobenzene detected on Mars could have derived from compounds like mellitic acid, consistent with the previous hypothesis by Benner et al. [3]. Among the aliphatic molecules, it was shown that pyrolysis of alkanes and alcohols in the presence of perchlorates produced polychlorine containing chloro-alkanes similar to what was observed on Mars. Surpris-ingly, however, similar treatment of acetic acid pro-duced chloroketones, instead, and no chloroalkanes were reported. This suggests that the chloroalkanes detected in the Sheepbed mudstone were not derived from aliphatic carboxylic acids, but instead were from more reduced alcohols or even alkanes, or perhaps were degradation products of more complicated organic material. Because organics analyses on mars will rely heavily on py-GC-MS of perchlorate-containing samples over the next decade, it is important to understand the fate of organic molecules of biotic and abiotic origin under such conditions. In this work we begin a series of experiments to improve our understanding of products generated during py-GC-MS of increasingly complex organic molecules (esters, amides, peptides, nucleic acids, fatty acids) in the presence of perchlorate.

Burton, A. S.↗

Quantitative insights for diagnosing performance bottlenecks in lithium–sulfur batteries

Lithium–sulfur (Li–S) batteries hold significant promise for electric vehicles and aviation due to their high energy density and cost-effectiveness. However, understanding the root causes of performance degradation remains a formidable challenge, as the interplay of multiple factors obscures key failure mechanisms. A major limitation has been the inability to quantify soluble sulfur species within practical detection limits accurately and to correlate electrochemical processes with associated physical inventory changes. Here, we introduce the high-performance liquid chromatography-ultraviolet spectroscopy and gas chromatography sequential characterization (HUGS) toolkit, capable of precisely quantifying seven distinct sulfur and polysulfide species at concentrations as low as 40 ppb. HUGS has been successfully applied to practical coin and pouch cells without requiring cell modification. Furthermore, our self-developed software, Dr HUGS, enhanced the data analysis speed by over 30 times, enabling multi-source data integration and delivering comprehensive analysis results within minutes. Using HUGS, we identify significant capacity losses from inactive lithium and sulfur during initial cycles and sulfide-rich solid–electrolyte interphase (SEI) formation on the anode during later cycles. Notably, our findings reveal that soluble polysulfides have minimal contributions to capacity loss, challenging long-standing assumptions. Moreover, HUGS demonstrates that constant-pressure setups in Li–S pouch cells improve compositional uniformity compared to constant-gap configurations. For sulfurized polyacrylonitrile (SPAN) cathodes, unique issues such as non-sulfide SEI formation and lithium pulverization are observed, which can be mitigated through localized high-concentration electrolytes to enhance lithium inventory retention. By enabling precise quantification of critical inventory components, HUGS provides transformative insights into failure mechanisms across various electrolytes and cathode chemistries, guiding rational design strategies for next-generation energy storage systems.

25 ENERGY STORAGE↗

Synthesis and Development of Porous Polymeric Column Packing and Microchip Detectors for GC Analysis of Extraterrestrial Atmospheres

This report summarizes the last nine years research accomplishments under Cooperative Agreement NCC2-650 between NASA, Ames Research Center and SETI Institute. Four Major research tasks are conducted: 1. Gas chromatography column development. 2. Pyrosensor development. 3. Micro-machining gas chromatography instrument development. 4. Amino acid analysis and high molecular weight polyamino acid synthesis under prebiotic conditions. The following describes these results.

Shen, Thomas C.↗

Tri- and tetraterpenoid hydrocarbons in the Messel oil shale

The high-molecular-weight constituents of the branched and cyclic hydrocarbon fraction of the Messel oil shale (Eocene) have been examined by high-resolution gas chromatography and combined gas chromatography/mass spectrometry. The following compounds are present: perhydrolycopene, together with one or more unsaturated analogs with the same skeleton; a series of 4-methylsteranes in higher abundance than their 4-desmethyl analogs; two series of pentacyclic triterpanes, one series based on the hopane structure, and the other based on the 17 alpha-H hopane structure; and an intact triterpene hop-17(21)-ene. Only two additional triterpanes were detected in minor concentrations - namely, 30-normoretane and a C31 triterpane based on the hopane/lupane-type skeleton. The presence of these compounds suggests a significant microbial contribution to the forming sediment.

Kimble, B. J.↗

Temperature-dependent changes in gas chromatographic separation metrics for trihexyl(tetradecyl)phosphonium-based ionic liquid stationary phases and comparison to conventional polysiloxane stationary phases

Here, to assess whether the trihexyl(tetradecyl)phosphonium chloride ([P 66614 + ][Cl - ]) ionic liquid (IL), employed as a gas chromatographic stationary phase, exhibits temperature-dependent phase transitions or structural heterogeneity, retention thermodynamics for probe molecules of varied chemical structure were investigated by gas chromatography (GC) over the temperature range of 25 to 64 °C using van’t Hoff analysis. All van’t Hoff plots for n-alkanes (C8–C12) and other probe analytes were linear, indicating the absence of detectable phase-transition behavior. The [P 66614 + ][Cl - ] IL was further compared with the [P 66614 + ] bis[(trifluoromethyl)sulfonyl]imide ([P 66614 + ][NTf 2 - ]) IL and commercial polysiloxane stationary phases in terms of temperature-dependent resolution behavior and chromatographic selectivity over the temperature range of 28–52 °C. The resolution factors of analytes in mixtures obtained using gas chromatography–mass spectrometry (GC–MS) and the summation of resolution values decreased smoothly with temperature on both IL stationary phases and on the dimethylphenylcyano-substituted polymeric stationary phase (OV-1701), whereas the poly(50% diphenyl/50% dimethyl siloxane) stationary phase (SPB-50) exhibited irregularities in its temperature-dependent summation of resolution profile, showing a distinct maximum in the temperature range of 34–40 °C. Selectivity values for the IL stationary phases were largely determined by the anion, with the [P 66614 + ][Cl - ] IL providing enhanced separation between polar and aromatic analytes, while the [P 66614 + ][NTf 2 - ] IL favored dispersive and π-π interactions that resulted in a reversal of elution order for some aliphatic–aromatic and alkyne-containing analyte pairs. Capillary columns prepared using different surface activation methods and coated with identical [P 66614 + ][Cl - ] IL stationary phase showed indistinguishable temperature-dependent trends in summation of resolution value and selectivity. An evaluation of analyte-specific selectivity provides insight into the characteristic separation behavior of the stationary phases and enables identification of analyte classes that are more efficiently separated on the [P 66614 + ]-based IL stationary phases compared to conventional stationary phase materials.

Chromatographic selectivity↗

In situ identification of the Martian surface material and its interaction with the Martian atmosphere using DTA/GC

Little is known about the mineralogy of the martian surface material. Several techniques have been suggested as candidates for the in situ identification of the martian surface material. The most promising of these techniques include differential thermal analysis (DTA) coupled with gas chromatography (GC) and differential scanning calorimetry (DSC) coupled with either mass spectrometry (MS) or GC. Our studies showed that differential thermal analysis coupled with gas chromatography (DTA/GC) is a more appropriate analytical technique than DSC/MS or DSC/GC to identify the mineralogy of the martian surface material in situ. DTA/GC can be regarded as an advancement from pyrolytic GC analyses that were successfully flown on previous missions, but have supplied only limited mineralogical information.

Mancinelli, R. L.↗

Carbon isotopic analysis of atmospheric methane by isotope-ratio-monitoring gas chromatography-mass spectrometry

Less than 15 min are required for the determination of delta C(sub PDB)-13 with a precision of 0.2 ppt(1 sigma, single measurement) in 5-mL samples of air containing CH4 at natural levels (1.7 ppm). An analytical system including a sample-introduction unit incorporating a preparative gas chromatograph (GC) column for separation of CH4 from N2, O2, and Ar is described. The 15-min procedure includes time for operation of that system, high-resolution chromatographic separation of the CH4, on-line combustion and purification of the products, and isotopic calibration. Analyses of standards demonstrate that systematic errors are absent and that there is no dependence of observed values of delta on sample size. For samples containing 100 ppm or more CH4, preconcentration is not required and the analysis time is less than 5 min. The system utilizes a commercially available, high-sensitivity isotope-ratio mass spectrometer. For optimal conditions of smaple handling and combustion, performance of the system is within a factor of 2 of the shot-noise limit. The potential exists therefore for analysis of samples as small as 15 pmol CH4 with a standard deviation of less than 1 ppt.

Merritt, Dawn A.↗

Characterization of Kariya ( Hildegardia barteri (Mast.) Kosterm) Seed Oil Fatty Acid Methyl Ester Prepared from Basic Catalytic Transesterification

The rising global energy demand, alongside concerns regarding environmental deterioration due to the use of fossil fuels, has spurred extensive investigation into renewable energy alternatives. Biomass-derived biodiesel, especially from lesser-known oil sources, emerges as a promising option. This research focuses on analyzing the fatty acid methyl esters (FAMEs) derived from Kariya (Hildegardia barteri (Mast.) Kosterm) seed oil through basic catalytic transesterification using gas chromatography–flame ionization detector (GC–FID) analysis, assessing its potential as a biodiesel feedstock. Oil extraction from Kariya seeds was carried out using three solvents (n-hexane, ethanol, and a 1:1 blend of hexane and ethanol), followed by transesterification with methanol. Gas chromatography–mass spectrometry (GC–MS) and GC–FID analyses were utilized to identify and quantify FAMEs in the resulting biodiesel. The results revealed various FAMEs, including methyl myristate, methyl palmitate, methyl stearate, methyl oleate, methyl linoleate, and methyl linolenate. Significant differences in FAME composition were observed among the samples, with hexane–ethanol Kariya oil biodiesel (HE-KOB) showing the highest FAME content (76.1%). This combination of solvents exhibited synergistic effects on the composition of HE-KOB, suggesting potential optimization strategies for biodiesel production. Fourier transform infrared spectroscopy (FTIR) provided additional insights into the molecular composition of the biodiesel samples, confirming their biodiesel nature through the identified functional groups such as methyl, methylene, hydrocarbon, ester, aldehyde, and alkene. Thermogravimetric analysis (TGA) for thermal decomposition also gave an insight into FAME composition and its contribution to the degree of conversion of biodiesel to energy. These findings highlight the feasibility of utilizing Kariya seed oil as a biodiesel feedstock, emphasizing the importance of solvent selection and transesterification conditions in optimizing FAME yield and composition. This research contributes to the exploration of underutilized oil sources for sustainable biodiesel production, aligning with the global shift towards cleaner and renewable energy sources.

09 BIOMASS FUELS↗

A gas chromatographic air analyzer fabricated on a silicon wafer

A miniature gas analysis system has been built based on the principles of gas chromatography (GC). The major components are fabricated in silicon using photolithography and chemical etching techniques, which allows size reductions of nearly three orders of magnitude compared to conventional laboratory instruments. The chromatography system consists of a sample injection valve and a 1.5-m-long separating capillary column, which are fabricated on a substrate silicon wafer. The output thermal conductivity detector is separately batch fabricated and integrably mounted on the substrate wafer. The theory of gas chromatography has been used to optimize the performance of the sensor so that separations of gaseous hydrocarbon mixtures are performed in less than 10 s. The system is expected to find application in the areas of portable ambient air quality monitors, implanted biological experiments, and planetary probes.

Terry, S. C.↗

Search for life on Mars: Evaluation of techniques

An important question for exobiology is, did life evolve on Mars? To answer this question, experiments must be conducted on the martian surface. Given current mission constraints on mass, power, and volume, these experiments can only be performed using proposed analytical techniques such as: electron microscopy, X-ray fluorescence, X-ray diffraction, a-proton backscatter, g-ray spectrometry, differential thermal analysis, differential scanning calorimetry, pyrolysis gas chromatography, mass spectrometry, and specific element detectors. Using prepared test samples consisting of 1% organic matter (bovine serum albumin) in palagonite and a mixture of palagonite, clays, iron oxides, and evaporites, it was determined that a combination of X-ray diffraction and differential thermal analysis coupled with gas chromatography provides the best insight into the chemistry, mineralogy, and geological history of the samples.

Schwartz, D. E.↗

Analytical methods for toxic gases from thermal degradation of polymers

Toxic gases evolved from the thermal oxidative degradation of synthetic or natural polymers in small laboratory chambers or in large scale fire tests are measured by several different analytical methods. Gas detector tubes are used for fast on-site detection of suspect toxic gases. The infrared spectroscopic method is an excellent qualitative and quantitative analysis for some toxic gases. Permanent gases such as carbon monoxide, carbon dioxide, methane and ethylene, can be quantitatively determined by gas chromatography. Highly toxic and corrosive gases such as nitrogen oxides, hydrogen cyanide, hydrogen fluoride, hydrogen chloride and sulfur dioxide should be passed into a scrubbing solution for subsequent analysis by either specific ion electrodes or spectrophotometric methods. Low-concentration toxic organic vapors can be concentrated in a cold trap and then analyzed by gas chromatography and mass spectrometry. The limitations of different methods are discussed.

Hsu, M.-T. S.↗

Evaluation of the application of some gas chromatographic methods for the determination of properties of synthetic fuels

The purpose of the investigation was to evaluate the applicability, to some synthetic fuels, of some gas chromatographic methods now under development for use with petroleum based fuels. Thirty-two jet and diesel fuel samples which were prepared from oil shale and coal syncrudes were examined. The boiling range distribution of each was determined by gas chromatography, and from that data distillation properties were calculated. The calculated results gave sufficient agreement with the measured values that the equations could be useable in their present form. Bulk fuel properties were calculated for the sixteen JP-5 and Diesel No. 2 type fuels. The results show that the equations would not give useable results. Capillary column gas chromatography was used to determine the n-alkane content of the eight JP-5 type samples and the results related to the observed freezing points. The results show that the concentrations of the long straight chain molecules in the fuels exert influence on the freezing point but are not the complete controlling factor.

Antoine, A. C.↗

Evaluation of the application of some gas chromatographic methods for the determination of properties of synthetic fuels

The purpose of the investigation was to evaluate the applicability, to some synthetic fuels, of some gas chromatographic methods now under development for use with petroleum based fuels. Thirty-two jet and diesel fuel samples which were prepared from oil shale and coal syncrudes were examined. The boiling range distribution of each was determined by gas chromatography, and from that data distillation properties were calculated. The calculated results gave sufficient agreement with the measured values that the equations could be useable in their present form. Bulk fuel properties were calculated for the 16 JP-5 and Diesel No. 2 type fuels. The results show that the equations would not give useable results. Capillary column gas chromatography was used to determine the n-alkane content of the eight JP-5 type samples and the results related to the observed freezing points. The results show that the concentrations of the long straight chain molecules in the fuels exert influence on the freezing point but are not the complete controlling factor.

Antoine, A. C.↗

Surface Protection and Catalytic CH Alumination

This dataset supports a publication, "Surface Protected Organozirconium Catalyzes C–H Alumination of Saturated Hydrocarbons", and describes the surface-organozirconium catalyzed exchange of ethyl group in AlEt3 for dodecyl or methyl from dodecane or methane. The research describes the benefits of capping remaining surface OH with SiMe3 for improving yields and turnovers. The dataset includes characterization of the precatalyst using solid-state nuclear magnetic resonance spectroscopy and diffuse reflectance infrared Fourier transform spectroscopy (DRIFTS), as well as gas chromatography and solution NMR of reaction products.

Catalysis and mechanisms of reactions↗

Using Separation-Enhanced Isotope Ratio Mass Spectrometry to Enable Increased Renewable Carbon Content in Transportation Fuels (CRADA 525)

Stable isotope ratio measurements of carbon atoms using isotope ratio mass spectrometry (IRMS) can be an effective tool for quantifying biogenic carbon in co-processed fuels, with results approaching the precision and accuracy of accelerator mass spectrometry (AMS). The lower cost of an IRMS may enable deployment to refineries, improving access and analysis turnaround times (≤2 hours), and, by extension, provide data that can allow process optimization to maximize renewable carbon in desired refinery products. This project explored the integration of chemical separation with IRMS analyses to enable highly detailed tracking of biogenic carbon into fuel product streams separated by boiling point range, chemical class, or specific compound. Forty-nine fuels and fuel components of fossil and biogenic origin, spanning gasoline and diesel boiling point ranges, were received from three refiners and were analyzed for their δ 13 C values via IRMS. Results spanned a 13 C range from ca. 10‰ to 44‰ and reflect materials derived from sustainable sources (e.g., C4 or C3 plants, animal-based pathways, syngas) or from fossil-derived fuels. Common ranges are approximately 18‰ to 9‰ and approximately 30‰ to 20‰ for C4 and C3 plants, respectively, and approximately 34‰ to 24‰ and approximately 70‰ to 33‰ for petroleum-derived fuels and methane, respectively. Fuel-like standards were developed and tested using direct-injection elemental analyzer (EA) IRMS for liquid fuels. This method was compared with the published methods, yielding statistically similar results. Four blend curve sets were produced ranging from 0% to 100% of a fuel containing biogenic carbon, focusing on 0% to 10% biogenic carbon. Linear fits were the most applicable for two of the four blend curve sets; however, two sets were found to exhibit slightly quadratic behavior, which was more pronounced in low biogenic blend samples, necessitating second-order fits. The origin of the slight quadratic behavior remains unclear; however, the discussion points to possible interpretations. CanmetENERGY thoroughly characterized a majority of the samples using one- and two-dimensional gas chromatography (GC and GC×GC, respectively) and other analyses. Selected samples were subjected to solid phase extraction (SPE) for saturate, olefin, aromatic, and polar (SOAP) analysis, and the resulting solvent-diluted fractions containing saturates and aromatics were returned to Pacific Northwest National Laboratory (PNNL), where the solvent was removed via evaporation or physical separation using GC techniques. Characterization and separations provided an understanding of saturate and aromatic content, as well as boiling point ranges for each sample and sample fraction. Samples resulting from SPE were examined using EA-IRMS and gas chromatography combustion IRMS (GC-C-IRMS) analyses. Both approaches suggest that the range in values between end-members can be increased by selecting the paraffinic or aromatic fraction of the end-member or by selecting among individual compounds resulting from GC separation of the paraffinic fractions. Considerable work remains to put these approaches into practice and statistically validate the benefit for using a fraction or individual compound over bulk analysis of a sample. However, initial results suggest that separations provide advantages for samples having blend ratios of less than 10% biogenic blendstocks. 13 C results showed statistically similar biofuel blend results to those obtained at PNNL, although additional work is needed to obtain better reproducibility. Select samples were sent to Los Alamos National Laboratory (LANL) for IRMS measurements and Beta Analytics for AMS measurements. This work suggests that IRMS and AMS yield closely comparable results and in some circumstances, IRMS could serve as a surrogate for AMS. While additional work is needed to better resolve statistical advantages for separations and better show the comparable nature of IRMS and AMS in both the biogenic carbon analysis of bulk chemical classes, initial results from this study suggest that these should be pursued in order to proliferate this approach for quantifying biogenic carbon in transportation fuels to the refinery level, thereby potentially enabling process optimization in co-processing scenarios.

09 BIOMASS FUELS↗