Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Fourier imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Algorithm for Wavefront Sensing Using an Extended Scene

A recently conceived algorithm for processing image data acquired by a Shack-Hartmann (SH) wavefront sensor is not subject to the restriction, previously applicable in SH wavefront sensing, that the image be formed from a distant star or other equivalent of a point light source. That is to say, the image could be of an extended scene. (One still has the option of using a point source.) The algorithm can be implemented in commercially available software on ordinary computers. The steps of the algorithm are the following: 1. Suppose that the image comprises M sub-images. Determine the x,y Cartesian coordinates of the centers of these sub-images and store them in a 2xM matrix. 2. Within each sub-image, choose an NxN-pixel cell centered at the coordinates determined in step 1. For the ith sub-image, let this cell be denoted as si(x,y). Let the cell of another subimage (preferably near the center of the whole extended-scene image) be designated a reference cell, denoted r(x,y). 3. Calculate the fast Fourier transforms of the sub-sub-images in the central NxN portions (where N < N and both are preferably powers of 2) of r(x,y) and si(x,y). 4. Multiply the two transforms to obtain a cross-correlation function Ci(u,v), in the Fourier domain. Then let the phase of Ci(u, v) constitute a phase function, phi(u,v). 5. Fit u and v slopes to phi (u,v) over a small u,v subdomain. 6. Compute the fast Fourier transform, Si(u,v) of the full NxN cell si(x,y). Multiply this transform by the u and phase slopes obtained in step 4. Then compute the inverse fast Fourier transform of the product. 7. Repeat steps 4 through 6 in an iteration loop, cumulating the u and slopes, until a maximum iteration number is reached or the change in image shift becomes smaller than a predetermined tolerance. 8. Repeat steps 4 through 7 for the cells of all other sub-images.

Sidick, Erkin↗

The Wide-Field Imaging Interferometry Testbed: Enabling Techniques for High Angular Resolution Astronomy

The Wide-Field Imaging Interferometry Testbed (WIIT) was designed to develop techniques for wide-field of view imaging interferometry, using "double-Fourier" methods. These techniques will be important for a wide range of future spacebased interferometry missions. We have provided simple demonstrations of the methodology already, and continuing development of the testbed will lead to higher data rates, improved data quality, and refined algorithms for image reconstruction. At present, the testbed effort includes five lines of development; automation of the testbed, operation in an improved environment, acquisition of large high-quality datasets, development of image reconstruction algorithms, and analytical modeling of the testbed. We discuss the progress made towards the first four of these goals; the analytical modeling is discussed in a separate paper within this conference.

Rinehart, S. A.↗

Nonnegative Matrix Factorization for Efficient Hyperspectral Image Projection

Hyperspectral imaging for remote sensing has prompted development of hyperspectral image projectors that can be used to characterize hyperspectral imaging cameras and techniques in the lab. One such emerging astronomical hyperspectral imaging technique is wide-field double-Fourier interferometry. NASA's current, state-of-the-art, Wide-field Imaging Interferometry Testbed (WIIT) uses a Calibrated Hyperspectral Image Projector (CHIP) to generate test scenes and provide a more complete understanding of wide-field double-Fourier interferometry. Given enough time, the CHIP is capable of projecting scenes with astronomically realistic spatial and spectral complexity. However, this would require a very lengthy data collection process. For accurate but time-efficient projection of complicated hyperspectral images with the CHIP, the field must be decomposed both spectrally and spatially in a way that provides a favorable trade-off between accurately projecting the hyperspectral image and the time required for data collection. We apply nonnegative matrix factorization (NMF) to decompose hyperspectral astronomical datacubes into eigenspectra and eigenimages that allow time-efficient projection with the CHIP. Included is a brief analysis of NMF parameters that affect accuracy, including the number of eigenspectra and eigenimages used to approximate the hyperspectral image to be projected. For the chosen field, the normalized mean squared synthesis error is under 0.01 with just 8 eigenspectra. NMF of hyperspectral astronomical fields better utilizes the CHIP's capabilities, providing time-efficient and accurate representations of astronomical scenes to be imaged with the WIIT.

NMF↗

Discrete Fourier Transform in a Complex Vector Space

An image-based phase retrieval technique has been developed that can be used on board a space based iterative transformation system. Image-based wavefront sensing is computationally demanding due to the floating-point nature of the process. The discrete Fourier transform (DFT) calculation is presented in "diagonal" form. By diagonal we mean that a transformation of basis is introduced by an application of the similarity transform of linear algebra. The current method exploits the diagonal structure of the DFT in a special way, particularly when parts of the calculation do not have to be repeated at each iteration to converge to an acceptable solution in order to focus an image.

Dean, Bruce H.↗

Signal-to-noise ratio comparison of encoding methods for hyperpolarized noble gas MRI

Some non-Fourier encoding methods such as wavelet and direct encoding use spatially localized bases. The spatial localization feature of these methods enables optimized encoding for improved spatial and temporal resolution during dynamically adaptive MR imaging. These spatially localized bases, however, have inherently reduced image signal-to-noise ratio compared with Fourier or Hadamad encoding for proton imaging. Hyperpolarized noble gases, on the other hand, have quite different MR properties compared to proton, primarily the nonrenewability of the signal. It could be expected, therefore, that the characteristics of image SNR with respect to encoding method will also be very different from hyperpolarized noble gas MRI compared to proton MRI. In this article, hyperpolarized noble gas image SNRs of different encoding methods are compared theoretically using a matrix description of the encoding process. It is shown that image SNR for hyperpolarized noble gas imaging is maximized for any orthonormal encoding method. Methods are then proposed for designing RF pulses to achieve normalized encoding profiles using Fourier, Hadamard, wavelet, and direct encoding methods for hyperpolarized noble gases. Theoretical results are confirmed with hyperpolarized noble gas MRI experiments. Copyright 2001 Academic Press.

Non-NASA Center↗

The application of an optical Fourier spectrum analyzer on detecting defects in mass-produced satellite photographs

Various defects in mass-produced pictures transmitted to earth from a satellite are investigated. It is found that the following defects are readily detectable via Fourier spectrum analysis: (1) bit slip, (2) breakup causing loss of image, and (3) disabled track at the top of the imagery. The scratches made on the film during mass production, which are difficult to detect by visual observation, also show themselves readily in Fourier spectrum analysis. A relation is established between the number of scratches, their width and depth and the intensity of their Fourier spectra. Other defects that are found to be equally suitable for Fourier spectrum analysis or visual (image analysis) detection are synchronous loss without blurring of image, and density variation in gray scale. However, the Fourier spectrum analysis is found to be unsuitable for detection of such defects as pin holes, annotation error, synchronous loss with blurring of images, and missing image in the beginning of the work order. The design of an automated, real time system, which will reject defective films, is treated.

Athale, R.↗

Stellar spectrum classifier

Stellar classification is accomplished by correlating holograms of classified spectra with the Fourier transform of the spectral images to be classified.

Reid, J. H.↗

Pulse Phase Thermography for Defect Detection and Visualization

Pulse Phase Thermography (PPT) has been reported as a novel powerful technique of the thermal NDE. It employs application of the Discrete Fourier Transform (DFT) to thermal images obtained following flash heating of the front surface of a specimen. The computed phasegrams are excellent for defect visualization in a wide range of materials. This is in part due to their low sensitivity to uneven heating. This work is an attempt to analyze advantages and limitations of PPT. Results of application of the DFT to simulated temperature decays are presented. The temperature evolution on a surface has been simulated based on an analytical solution of the one-dimensional heat diffusion problem. A more sophisticated study has been done for different sizes of defects using numerical solution of the three-dimensional mathematical model. Capabilities of PPT for in-depth scanning and for monitoring of the material loss are discussed. The recommendations for the practical application of the PPT are presented. Experimental results obtained following these recommendations are reported.

Marinetti, Sergio↗

Measuring Low-Order Aberrations in a Segmented Telescope

The in-focus PSF optimizer (IPO) is an algorithm for use in monitoring and controlling the alignment of the segments of a segmented-mirror astronomical telescope. IPO is so named because it computes wave-front aberrations of the telescope from digitized pointspread functions (PSFs) measured in infocus images. Inasmuch as distant astronomical objects that behave optically as point sources can typically be seen in almost any astronomical image, the main benefit afforded by IPO may be to enable maintenance of mirror-segment alignments without detracting from valuable scientific-observation time. IPO evolved from prescription-retrieval type algorithms. Prescription retrieval uses in-focus and out-of-focus PSFs to infer the state of an imaging optical system. The state, in this context, refers to the positions, orientations, and low-order figure errors of the optical elements in the system. Both prescription- retrieval and IPO use an iterative, nonlinear, least-squares optimizer to compute the optimal state parameters such that a digital computer-generated model image matches the digitized image acquired from the real system. The difference between IPO and prescription- retrieval algorithms is that IPO is specifically designed to utilize infocus images only. Although the restriction to in-focus images limits IPO to calculating only the lowest-order wave front aberrations, it also causes the resulting computation to take much less time because fewer degrees of freedom are included in the optimization process. In the prescription retrieval software developed at JPL, the model images are generated using the ray-trace/physical optics program, MACOS. IPO, on the other hand, uses a linear sensitivity matrix to compute the exit-pupil wave front from the system parameters; the wave front is then converted into a complex pupil field, which is then propagated to the image plane via a fast Fourier transform. This approach is computationally faster and requires less computer memory than is needed for prescription retrieval.

Ohara, Catherine↗

The Primordial Inflation Explorer (PIXIE)

The Primordial Inflation Explorer is an Explorer-class mission to measure the gravity-wave signature of primordial inflation through its distinctive imprint on the linear polarization of the cosmic microwave background. PIXIE uses an innovative optical design to achieve background-limited sensitivity in 400 spectral channels spanning 2.5 decades in frequency from 30 GHz to 6 THz (1 cm to 50 micron wavelength). Multi-moded non-imaging optics feed a polarizing Fourier Transform Spectrometer to produce a set of interference fringes, proportional to the difference spectrum between orthogonal linear polarizations from the two input beams. The differential design and multiple signal modulations spanning 11 orders of magnitude in time combine to reduce the instrumental signature and confusion from unpolarized sources to negligible levels. PIXIE will map the full sky in Stokes I, Q, and U parameters with angular resolution 2.6 deg and sensitivity 0.2 uK per 1 deg square pixel. The principal science goal is the detection and characterization of linear polarization from an inflationary epoch in the early universe, with tensor-to-scalar ratio r <10(exp -3) at 5 standard deviations. In addition, the rich PIXIE data will constrain physical processes ranging from Big Bang cosmology to the nature of the first stars to the physical conditions within the interstellar medium of the Galaxy. We describe the PIXIE instrument and mission architecture needed to detect the signature of an inflationary epoch in the early universe using only 4 semiconductor bolometers.

Kogut, Alan J.↗

The Primordial Inflation Explorer (PIXIE)

The Primordial Inflation Explorer is an Explorer-class mission to measure the gravity-wave signature of primordial inflation through its distinctive imprint on the linear polarization of the cosmic microwave background. PIXIE uses an innovative optical design to achieve background-limited sensitivity in 400 spectral channels spanning 2.5 decades in frequency from 30 GHz to 6 THz (1 cm to 50 micron wavelength). Multi-moded non-imaging optics feed a polarizing Fourier Transform Spectrometer to produce a set of interference fringes, proportional to the difference spectrum between orthogonal linear polarizations from the two input beams. Multiple levels of symmetry and signal modulation combine to reduce the instrumental signature and confusion from unpolarized sources to negligible levels. PIXIE will map the full sky in Stokes I, Q, and U parameters with angular resolution 2.6 deg and sensitivity 0.2 μK per 1 deg square pixel. The principal science goal is the detection and characterization of linear polarization from an inflationary epoch in the early universe, with tensor-to-scalar ratio r less than 10(exp −3) at 5 standard deviations. In addition, PIXIE will measure the absolute frequency spectrum to constrain physical processes ranging from inflation to the nature of the first stars to the physical conditions within the interstellar medium of the Galaxy. We describe the PIXIE instrument and mission architecture with an emphasis on the expected level of systematic error suppression.

Primordial Inflation Explorer is an Explorer-class↗

The Primordial Inflation Explorer (PIXIE)

The Primordial Inflation Explorer is an Explorer-class mission to open new windows on the early universe through measurements of the polarization and absolute frequency spectrum of the cosmic microwave background. PIXIE will measure the gravitational-wave signature of primordial inflation through its distinctive imprint in linear polarization, and characterize the thermal history of the universe through precision measurements of distortions in the blackbody spectrum. PIXIE uses an innovative optical design to achieve background-limited sensitivity in 400 spectral channels spanning over 7 octaves in frequency from 30 GHz to 6 THz (1 cm to 50 micron wavelength). Multi-moded non-imaging optics feed a polarizing Fourier Transform Spectrometer to produce a set of interference fringes, proportional to the difference spectrum between orthogonal linear polarizations from the two input beams. Multiple levels of symmetry and signal modulation combine to reduce systematic errors to negligible levels. PIXIE will map the full sky in Stokes I, Q, and U parameters with angular resolution 2.6 degrees and sensitivity 70 nK per 1degree square pixel. The principal science goal is the detection and characterization of linear polarization from an inflationary epoch in the early universe, with tensor-to-scalar ratio r < 10(exp. -3) at 5 standard deviations. The PIXIE mission complements anticipated ground-based polarization measurements such as CMBS4, providing a cosmic-variance-limited determination of the large-scale E-mode signal to measure the optical depth, constrain models of reionization, and provide a firm detection of the neutrino mass (the last unknown parameter in the Standard Model of particle physics). In addition, PIXIE will measure the absolute frequency spectrum to characterize deviations from a blackbody with sensitivity 3 orders of magnitude beyond the seminal COBE/FIRAS limits. The sky cannot be black at this level; the expected results will constrain physical processes ranging from inflation to the nature of the first stars and the physical conditions within the interstellar medium of the Galaxy. We describe the PIXIE instrument and mission architecture required to measure the CMB to the limits imposed by astrophysical foregrounds.

Kogut, Alan↗

Geologic interpretation of texture in Seasat and SIR-A radar images

Geological information in radar images of heavily vegetated areas is contained mainly in the depiction of topography as image texture. This paper describes three techniques for the analysis of texture in radar images: the split-spectrum technique, Fourier transforms of subareas, and spatial frequency bandpass classification. These techniques were applied to a heavily vegetated area of Belize in Central America in order to evaluate their utility for geological mapping; Seasat and Shuttle Imaging Radar (SIR-A) images were considered.

Farr, T. G.↗

Synthetic estimation filters for a control system

Hybrid optical correlators, which use spatial light modulators and solid state imagers to interface computers and optical Fourier correlators, will allow the rapid changing of filters and digital pre- or post-correlation processing in vision systems. However, optical correlation (particulary with phase-only filtration) is notoriously sensitive to mismatches of rotation and magnification between the reference image and the input image. Such sharpness is not always desirable if the correlation pattern is to be used in a control system. Two methods of conforming the response of an inherently sharp-response optical correlation to an in plane rotation between reference and object images are discussed. The objective is to condition the correlation for better suitability to a vision-controlled system. The first method is controlled convolutional blurring of a reference image followed by construction of a matched filter (perhaps implemented as a phase-only filter). An alternative is discussed in more detail: it is a synthesis from sharp filters, so weighted as to produce a specified off-center behavior.

Juday, Richard D.↗

A statistical technique for processing radio interferometer data

The output of a radio interferometer is the Fourier transform of the object under investigation. Due to the limited coverage of the Fourier plane, the reconstruction of the image of the source is blurred by the beam of the synthesized array. A maximum-likelihood processing technique is described which uses the statistical properties of the received noise-like signals. This technique has been used extensively in the processing of large-aperture seismic arrays. This inversion method results in a synthesized beam that is more uniform, has lower sidelobes, and higher resolution than the normal Fourier transform methods. The maximum-likelihood method algorithm was applied successfully to very long baseline and short baseline interferometric data.

Papadopoulos, G. D.↗

(abstract) Topographic Signatures in Geology

Topographic information is required for many Earth Science investigations. For example, topography is an important element in regional and global geomorphic studies because it reflects the interplay between the climate-driven processes of erosion and the tectonic processes of uplift. A number of techniques have been developed to analyze digital topographic data, including Fourier texture analysis. A Fourier transform of the topography of an area allows the spatial frequency content of the topography to be analyzed. Band-pass filtering of the transform produces images representing the amplitude of different spatial wavelengths. These are then used in a multi-band classification to map units based on their spatial frequency content. The results using a radar image instead of digital topography showed good correspondence to a geologic map, however brightness variations in the image unrelated to topography caused errors. An additional benefit to the use of Fourier band-pass images for the classification is that the textural signatures of the units are quantative measures of the spatial characteristics of the units that may be used to map similar units in similar environments.

topography geology texture Fourier analysis↗

Prototype Optical Correlator For Robotic Vision System

Known and unknown images fed in electronically at high speed. Optical correlator and associated electronic circuitry developed for vision system of robotic vehicle. System recognizes features of landscape by optical correlation between input image of scene viewed by video camera on robot and stored reference image. Optical configuration is Vander Lugt correlator, in which Fourier transform of scene formed in coherent light and spatially modulated by hologram of reference image to obtain correlation.

Scholl, Marija S.↗