Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Flight Control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Harnessing Chemical Short‐Range Disorder to Improve Lithium Retention in Epitaxial LLTO Solid‐Electrolyte Thin Films

Lithium lanthanum titanate Li 3x La 2/3-x TiO 3 (LLTO) is a promising perovskite-based solid-state electrolyte for next-generation lithium-ion batteries, but controlling crystallinity and Li stoichiometry in thin-film form is challenging because high growth temperatures are required to achieve good crystallinity while Li remains strongly volatile. Here, we systematically investigate the effect of substrate temperature on epitaxial LLTO thin films grown by pulsed laser deposition. We identify a narrow growth window (750–800°C) in which LLTO films grow as c-axis oriented with atomically flat surfaces. Lower growth temperatures (<750°C) stabilize laterally extended, chemically disordered stripe domains that coexist with ordered LLTO regions, whereas higher temperatures (≥825°C) suppress these defects but promote island morphologies and Al/Ti interdiffusion. While spectroscopy measurements show that Ti remains in the 4+ oxidation state and Li is globally deficient for all films, our depth-resolved time-of-flight secondary ion mass spectrometry studies reveal that the 700°C film retains the highest Li content across its thickness. These results clarify how growth temperature controls crystallinity, chemical short-range disorder, and Li retention, and highlight moderate growth temperatures (∼700°C) as a route to mitigate Li loss in epitaxial solid-electrolyte films.

chemical short-range disorder↗

Initial Characterization of the NREL Large-Amplitude Motion Platform

The Large Amplitude Motion Platform (LAMP) at NREL represents a significant advancement in the controlled testing of Wave Energy Converters (WECs) under laboratory conditions. Originally designed by E2M as a six-degree-of-freedom (DOF) Stewart platform for flight simulation, LAMP has been adapted by NREL to facilitate the mounting and evaluation of WECs. This adaptation enables dry testing of WECs using motion profiles similar to the ocean, facilitating the iterative design, testing, and validation of WEC performance prior to ocean deployments. This report presents the initial work completed to characterize LAMP, with particular emphasis on its stability and operational capabilities across various single and multi-degree-of-freedom (DOF) motion profiles. The report includes planned comparisons at three distinct mass payloads, aimed at assessing the platform's positional accuracy, frequency response, and endurance over extended runtime periods. These experimental tests are critical for establishing the platform's limitations and ensuring that the data generated during WEC validation is both accurate and reproducible. The outcomes of this study not only contribute to a deeper understanding of LAMP's capabilities but also lay the groundwork for future advancements in WEC testing methodologies. By providing robust and reliable performance data within a controlled laboratory setting, the findings are expected to significantly enhance the development and commercialization of marine energy technologies. This report presents the initial findings of the LAMP Characterization work and proposed steps to further understand and characterize LAMP. Data collected during this work can be found on MHKDR at: https://mhkdr.openei.org/submissions/602 Note that this report shares the measured/found instantaneous maximum operating range of LAMP. For most applications the maximum operating range cannot be used for system health and longevity. The operating range and capabilities of LAMP will be evaluated on a case-by-case basis, single-DOF position, velocity, and acceleration values presented in Table 4a-c, and Table 5 should be taken as instantaneous absolute maximum values. Future use of LAMP will likely be limited to smaller values.

16 TIDAL AND WAVE POWER↗

Direct Visualization of Charge Migration in Bilayer Tantalum Oxide Films by Multimodal Imaging

Inspired by biological neuromorphic computing, artificial neural networks based on crossbar arrays of bilayer tantalum oxide memristors have shown to be promising alternatives to conventional complementary metal-oxide-semiconductor (CMOS) architectures. In order to understand the driving mechanism in these oxide systems, tantalum oxide films are resistively switched by conductive atomic force microscopy (C-AFM), and subsequently imaged by kelvin probe force microscopy (KPFM) and spatially resolved time-of-flight secondary ion mass spectrometry (ToF-SIMS). These workflows enable induction and analysis of the resistive switching mechanism as well as control over the resistively switched region of the film. In this work it is shown that the resistive switching mechanism is driven by both current and electric field effects. Reversible oxygen motion is enabled by applying low (<1 V) electric fields, while high electric fields generate irreversible breakdown of the material (>1 V). Fully understanding oxygen motion and electrical effects in bilayer oxide memristor systems is a fundamental step toward the adoption of memristors as a neuromorphic computing technology.

36 MATERIALS SCIENCE↗

3D camera assisted fully automated calibration of scanning laser Doppler vibrometers

Scanning laser Doppler vibrometers (LDV) are used to measure full-field vibration shapes of products and structures. In most commercially available scanning laser Doppler vibrometer systems the user manually draws a grid of measurement locations on a 2D camera image of the product. The determination of the correct physical measurement locations can be a time consuming and diffcult task. In this paper we present a new methodology for product testing and quality control that integrates 3D imaging techniques with vibration measurements. This procedure allows to test prototypes in a shorter period because physical measurements locations will be located automatically. The proposed methodology uses a 3D time-of-flight camera to measure the location and orientation of the test-object. The 3D image of the time-of-flight camera is then matched with the 3D-CAD model of the object in which measurement locations are pre-defined. A time of flight camera operates strictly in the near infrared spectrum. To improve the signal to noise ratio in the time-of-flight measurement, a time-of-flight camera uses a band filter. As a result of this filter, the laser spot of most laser vibrometers is invisible in the time-of-flight image. Therefore a 2D RGB-camera is used to find the laser-spot of the vibrometer. The laser spot is matched to the 3D image obtained by the time-of-flight camera. Next an automatic calibration procedure is used to aim the laser at the (pre)defined locations. Another benefit from this methodology is that it incorporates automatic mapping between a CAD model and the vibration measurements. This mapping can be used to visualize measurements directly on a 3D CAD model. Secondly the orientation of the CAD model is known with respect to the laser beam. This information can be used to find the direction of the measured vibration relatively to the surface of the object. With this direction, the vibration measurements can be compared more precisely with numerical experiments.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Direct synthesis of nanostructured V2O5 films using solution plasma spray approach for lithium battery application

We demonstrate for the first time, the synthesis of vanadium pentoxide (V{sub 2}O{sub 5}) nanoparticles and nanorods in the films using a high throughput solution plasma spray deposition approach. The scalable plasma spray method enables the direct deposition of large area nanostructured films of V{sub 2}O{sub 5} with controllable particle size and morphology. In this approach, the solution precursors (vanadium oxychloride and ammonium metavanadate) were injected externally into the plasma jet, which atomizes and pyrolyzes the precursors in-flight, resulting in the desired films on the current collectors. The microstructure analysis of the as synthesized films revealed pure nanocrystalline phase for V{sub 2}O{sub 5} with particles in the size range of 20-50 nm. The V{sub 2}O{sub 5} film based electrodes showed stable reversible discharge capacity in the range of 200-250 mAh g{sup -1} when cycled in the voltage window 2-4 V. We further discuss the mechanism for controlling the particle growth and morphology, and also the optimization of reversible lithium storage capacity. The nanorods of V{sub 2}O{sub 5} formed after the anneal treatment also show reversible storage capacity indicative of the potential use of such film based electrodes for energy storage.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Note: Optical and electronic design of an amplitude-modulated continuous-wave laser scanner for high-accuracy distance measurement

To utilize a time-of-flight-based laser scanner as a distance measurement sensor, the measurable distance and accuracy are the most important performance parameters to consider. For these purposes, the optical system and electronic signal processing of the laser scanner should be optimally designed in order to reduce a distance error caused by the optical crosstalk and wide dynamic range input. Optical system design for removing optical crosstalk problem is proposed in this work. Intensity control is also considered to solve the problem of a phase-shift variation in the signal processing circuit caused by object reflectivity. The experimental results for optical system and signal processing design are performed using 3D measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Proteomic profiling of brain cortex tissues in a Tau transgenic mouse model of Alzheimer's disease

Highlights: Black-Right-Pointing-Pointer A transgenic mouse model expressing NSE-htau23 was used. Black-Right-Pointing-Pointer 2D-gel electrophoresis to analyze the cortex proteins of transgenic mice was used. Black-Right-Pointing-Pointer Differentially expressed spots in different stages of AD were identified. Black-Right-Pointing-Pointer GSTP1 and CAII were downregulated with the progression of AD. Black-Right-Pointing-Pointer SCRN1 and ATP6VE1 were up regulated and down regulated differentially. -- Abstract: Alzheimer's disease (AD) involves regionalized neuronal death, synaptic loss, and an accumulation of intracellular neurofibrillary tangles and extracellular senile plaques. Although there have been numerous studies on tau proteins and AD in various stages of neurodegenerative disease pathology, the relationship between tau and AD is not yet fully understood. A transgenic mouse model expressing neuron-specific enolase (NSE)-controlled human wild-type tau (NSE-htau23), which displays some of the typical Alzheimer-associated pathological features, was used to analyze the brain proteome associated with tau tangle deposition. Two-dimensional electrophoresis was performed to compare the cortex proteins of transgenic mice (6- and 12-month-old) with those of control mice. Differentially expressed spots in different stages of AD were identified with ESI-Q-TOF (electrospray ionization quadruple time-of-flight) mass spectrometry and liquid chromatography/tandem mass spectrometry. Among the identified proteins, glutathione S-transferase P 1 (GSTP1) and carbonic anhydrase II (CAII) were down-regulated with the progression of AD, and secerin-1 (SCRN1) and V-type proton ATPase subunit E 1 (ATP6VE1) were up-regulated only in the early stages, and down-regulated in the later stages of AD. The proteins, which were further confirmed by RT-PCR at the mRNA level and with western blotting at the protein level, are expected to be good candidates as drug targets for AD. The study of up- and down-regulation of proteins during the progression of AD helps to explain the mechanisms associated with neuronal degeneration in AD.

60 APPLIED LIFE SCIENCES↗

Identification of serum biomarkers for occupational medicamentosa-like dermatitis induced by trichloroethylene using mass spectrometry

Occupational medicamentosa-like dermatitis induced by trichloroethylene (OMLDT) is an autoimmune disease and it has become a serious occupational health hazard. In the present study, we collected fasting blood samples from patients with OMLDT (n = 18) and healthy volunteers (n = 33) to explore serum peptidome patterns. Peptides in sera were purified using weak cation exchange magnetic beads (MB-WCX), and analyzed by matrix-assisted laser desorption ionization time-of-flight-mass spectrometry (MALDI-TOF-MS) and ClinProTools bioinformatics software. The intensities of thirty protein/peptide peaks were significantly different between the healthy control and OMLDT patients. A pattern of three peaks (m/z 2106.3, 2134.5, and 3263.67) was selected for supervised neural network (SNN) model building to separate the OMLDT patients from the healthy controls with a sensitivity of 95.5% and a specificity of 73.8%. Furthermore, two peptide peaks of m/z 4091.61 and 4281.69 were identified as fragments of ATP-binding cassette transporter family A member 12 (ABCA12), and cationic trypsinogen (PRRS1), respectively. Our findings not only show that specific proteomic fingerprints in the sera of OMLDT patients can be served as a differentiated tool of OMLDT patients with high sensitivity and high specificity, but also reveal the novel correlation between OMLDT with ABC transports and PRRS1, which will be of potential value for clinical and mechanistic studies of OMLDT. - Highlights: • Identify 30 differential protein/peptide peaks between OMLDT and healthy control • The test sensitivity and test specificity were 95.5% and 73.8%, respectively. • ABCA12 and PRSS1 were identified as potential biomarkers in OMLDT patients.

60 APPLIED LIFE SCIENCES↗

FPGA-Based Self-Calibrating Time-to-Digital Converter for Time-of-Flight Experiments

We describe the architecture of a FPGA-based self-calibrating Time to Digital Converter (TDC), specifically intended to measure the width of an input pulse. The configuration consists of two controllable ring oscillators with a very small difference in their frequencies, wherein this difference determines the achievable resolution. The calibration scheme relies on an accurate pulse-generator or external crystal-oscillator to provide a stable calibration pulse for the system. We implemented the TDC on an Altera Stratix II device where we measured a Least Significant Bit of 41 ps (an RMS resolution of 11.8 ps). We present details of the methods used to calibrate the TDC, the characterization process, and discuss the effects of variations in temperature and voltage.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Apolipoprotein C-II Is a Potential Serum Biomarker as a Prognostic Factor of Locally Advanced Cervical Cancer After Chemoradiation Therapy

Purpose: To determine pretreatment serum protein levels for generally applicable measurement to predict chemoradiation treatment outcomes in patients with locally advanced squamous cell cervical carcinoma (CC). Methods and Materials: In a screening study, measurements were conducted twice. At first, 6 serum samples from CC patients (3 with no evidence of disease [NED] and 3 with cancer-caused death [CD]) and 2 from healthy controls were tested. Next, 12 serum samples from different CC patients (8 NED, 4 CD) and 4 from healthy controls were examined. Subsequently, 28 different CC patients (18 NED, 10 CD) and 9 controls were analyzed in the validation study. Protein chips were treated with the sample sera, and the serum protein pattern was detected by surface-enhanced laser desorption and ionization–time-of-flight mass spectrometry (SELDI-TOF MS). Then, single MS-based peptide mass fingerprinting (PMF) and tandem MS (MS/MS)-based peptide/protein identification methods, were used to identify protein corresponding to the detected peak. And then, turbidimetric assay was used to measure the levels of a protein that indicated the best match with this peptide peak. Results: The same peak 8918 m/z was identified in both screening studies. Neither the screening study nor the validation study had significant differences in the appearance of this peak in the controls and NED. However, the intensity of the peak in CD was significantly lower than that of controls and NED in both pilot studies (P=.02, P=.04) and validation study (P=.01, P=.001). The protein indicated the best match with this peptide peak at 8918 m/z was identified as apolipoprotein C-II (ApoC-II) using PMF and MS/MS methods. Turbidimetric assay showed that the mean serum levels of ApoC-II tended to decrease in CD group when compared with NED group (P=.078). Conclusion: ApoC-II could be used as a biomarker for detection in predicting and estimating the radiation treatment outcome of patients with CC.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Experimental determination of precision, resolution, accuracy and trueness of time-of-flight neutron diffraction strain measurements

We discuss a simple statistical analysis which yields the precision, resolution, accuracy and trueness of diffraction-based lattice strain measurements. The procedure consists of measuring the thermal expansion induced in each component of an ideal, non-reacting, two-component, crystalline powder sample in situ. One component, with a high coefficient of thermal expansion (CTE), serves as an internal thermometer. The quantities of interest are obtained by determining the smallest, statistically significant, thermal lattice strain which can be detected through diffraction analysis in the second, low CTE, component in response to controlled temperature changes. This procedure also provides a robust check of the alignment of the diffraction system and is able to reveal the presence of systematic errors. The application of this technique to a time-of-flight engineering diffractometer/strain scanner is presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Videos, photos, and AI-derived grain size data associated with “High-throughput AI Video Surveys Enable Reproducible Multiscale Sediment Size Mapping, with Implications for Hydrobiogeochemical Parameterization”

NOTE: The manuscript associated with this data package is currently in review. The data may be revised based on reviewer feedback. Upon manuscript acceptance, this data package will be updated with the final dataset and additional metadata. This data package is associated with the manuscript “High-throughput AI Video Surveys Enable Reproducible Multiscale Sediment Size Mapping, with Implications for Hydrobiogeochemical Parameterization” under review. This data package includes five data types: 1) raw photos and videos from drone survey and walking smartphone surveys; 2) images derived from raw videos; 3) manual labeling of reference scales; 4) metadata for all images and photo resolution derived from artificial intelligence (AI) models or manual labels, 5) grain size data obtained from AI models for all photos, 6) metadata and grain size data after quality control, 7) summaries of sample efficiency for all data, and 8) computational fluid dynamics (CFD) data used to support hydro-biogeochemical (HBGC) parameter estimation. Such data is used to 1) demonstrate significant improvements in accuracy, efficiency, and quality control for grain size data collection with the help of AI models, 2) study the spatial heterogeneity of grain size and observation reproducibility based on tens of thousands of data points generated by the AI models, and 3) evaluate the impacts of grain size heterogeneity on key HBGC parameters across sediment-to-reach and hourly-to-yearly scales. In particular, the data package contains 116 folders and 179696 files. The files include 41 videos in .mov format, 64047 photos in .jpg format, 13541 video-derived photos in .png format, 12747 segmentation mask data in .tif format, 12747 segmentation data in .json format, 24771 .csv files that with metadata and grain size for each individual photo as well as water depth and velocity data from CFD and observation, 51791 .txt files of raw AI predicted labels, and 11 flight record data in .srt format. The summary for all metadata and grain size statistics information is included in “Scales_V3_NG.csv” and “Statistics_V3_NG.csv”. The summary for data that pass data quality control (QC) level 0-2 is included in “QCStatistics_V3_NG.csv”. The QC level 0 represents photos whose photo resolution is positive, excluding photos that miss reference scale. The QC level 1 means reference scale circularity uncertainty is less than 5% for smartphone images while representing photo resolution is larger than 0.44 mm/pixel for drone images. The QC level 2 means excluding photos whose grain number is less than 100, a minimum number of grains recommended by classic literature. The summary for each video’s name, length, frame rates, survey area, grain number, survey efficiency, etc. can be found in “QCSummary_V3_NG.csv”. The summary for site name, GPS coordinates, and number of images at each site can be found in “SitesSummary_V3_*.csv” files. Overall computational efficiency summary is reported in Table 4 of accompanying manuscript. Additionally, the nitrate concentration data used in this work was downloaded from an existing dataset published on ESS-DIVE (Boat-Dragged Sensor Hanford Reach.csv; Conner A. et al., 2020). We thank the United States Forest Service, Washington Department of Fish and Wildlife, Washington Department of Natural Resources, Cowiche Canyon Conservatory, Port of Benton, and the Confederated Tribes and Bands of the Yakama Nation for access to field locations where the data were collected. We also thank the Yakama Nation Tribal Council and Yakama Nation Fisheries for working with us to facilitate data collection and optimization of data usage according to their values and worldview.

54 ENVIRONMENTAL SCIENCES↗

Synthesis and Purification of Homogeneous Lipid-Based Peptide Nanocarriers by Overcoming Phospholipid Ester Hydrolysis

Despite the therapeutic promise of phospholipid-based nanocarriers, a major obstacle to their widespread clinical translation is a susceptibility to fatty acid ester hydrolysis, leading to lack of quality control and inconsistencies in self-assembly formulations. Using electrospray ionization mass spectrometry fragmentation in combination with matrix-assisted laser desorption/ionization time-of-flight mass spectrometry, we have demonstrated a method to detect hydrolysis of one or both of the fatty acid esters in a PEGylated phospholipid, DSPE-PEG, in conditions commonly applied during nanocarrier production. Because such carriers are increasingly being used to deliver peptide-based therapeutics, we further investigated the hydrolysis of phospholipid esters in conditions used for solid-phase peptide synthesis and high-performance liquid chromatography of peptides. We ultimately detail a synthetic strategy to reliably produce pure phospholipid–peptide bioconjugates (peptide amphiphiles), while avoiding unintended or unnoticed hydrolyzed byproducts that could lead to polymorphic nanotherapeutics with dampened therapeutic efficacy. We believe that such an approach could help standardize phospholipid–peptide-based therapeutic development, testing, and clinical translation.

60 APPLIED LIFE SCIENCES↗

Feasibility study of a compact neutron resonance transmission analysis instrument

Neutron Resonance Transmission Analysis (NRTA) uses resonant absorption of neutrons to infer the absolute isotopic composition of a target object, enabling applications in a broad range of fields such as archaeology, enrichment analysis of nuclear fuel, and arms control treaty verification. In the past, NRTA involved large user facilities and complex detector systems. However, recent advances in the intensity of compact neutron sources have made compact neutron imaging designs increasingly feasible. This work describes the Monte Carlo (MC) based design of a compact epithermal NRTA radiographic instrument which uses a moderated, compact deuterium-tritium (DT) neutron source and an epithermal neutron detector. Such an instrument would have a wide range of applications, and would be especially impactful for such scenarios as nuclear inspection and arms control verification exercises, where system complexity and mobility may be of critical importance. The MC simulations presented in this work demonstrate accurate time-of-flight (TOF) reconstructions for transmitted neutron energies, capable of differentiating isotopic compositions of nuclear material with high levels of accuracy. A new generation of miniaturized and increasingly more intense neutron sources will allow this technique to achieve measurements with greater precision and speed, with significant impact on a variety of engineering and societal problems.

47 OTHER INSTRUMENTATION↗

THE COSMIC INFRARED BACKGROUND EXPERIMENT (CIBER): THE LOW RESOLUTION SPECTROMETER

Absolute spectrophotometric measurements of diffuse radiation at 1 {mu}m to 2 {mu}m are crucial to our understanding of the radiative content of the universe from nucleosynthesis since the epoch of reionization, the composition and structure of the zodiacal dust cloud in our solar system, and the diffuse galactic light arising from starlight scattered by interstellar dust. The Low Resolution Spectrometer (LRS) on the rocket-borne Cosmic Infrared Background Experiment is a {lambda}/{Delta}{lambda} {approx} 15-30 absolute spectrophotometer designed to make precision measurements of the absolute near-infrared sky brightness between 0.75 {mu}m <{lambda} < 2.1 {mu}m. This paper presents the optical, mechanical, and electronic design of the LRS, as well as the ground testing, characterization, and calibration measurements undertaken before flight to verify its performance. The LRS is shown to work to specifications, achieving the necessary optical and sensitivity performance. We describe our understanding and control of sources of systematic error for absolute photometry of the near-infrared extragalactic background light.

79 ASTRONOMY AND ASTROPHYSICS↗

Elucidating High Field Phases of the Multiferroic MnWO4 with a Pulsed Magnetic Field and Time of Flight Neutron Laue Diffraction

We have combined time-of-flight neutron Laue diffraction and pulsed high magnetic fields at the Spallation Neutron Source to study the phase diagram of the multiferroic material MnWO4. The control of the field-pulse timing enabled an exploration of magnetic Bragg scattering through the time dependence of both the neutron wavelength and the pulsed magnetic field. This allowed us to observe several magnetic Bragg peaks in different field-induced phases of MnWO4 with a single instrument configuration. These phases were not previously amenable to neutron diffraction studies due to the large fields involved.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗