Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Fiber optic distributed temperature sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Measurement accuracy and spatial resolution of a distributed temperature sensor based on a two-pulse differential coherent reflectometer

We present a model and numerical simulation of a distributed temperature sensor based on a two-pulse differential coherent optical time-domain reflectometer (COTDR). The differential phase measured using a phase-sensitive Rayleigh reflectometer is shown to have a regular component, which is a linear function of temperature, and a random component, which is related to a random distribution of scattering centres in the fibre and restricts the accuracy of measurements of variations in temperature. Measurement accuracy can be improved by reducing the relative contribution of the random component via a decrease in pulse duration and/or an increase in the time delay between pulses. The spatial resolution of a differential two-pulse phase-sensitive reflectometer is shown to be determined by the time delay between pulses and to vary little with pulse duration. At a typical pulse duration (200 ns) and delay time (300 ns), the accuracy in measurements of variations in temperature in the 0.1-K range is 2 % and the spatial resolution is about 30 m. (fibre-optic sensors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Corrosion Sensors for Structural Health Monitoring of Oil and Natural Gas Infrastructure: A Review

Corrosion has been a great concern in the oil and natural gas industry costing billions of dollars annually in the U.S. The ability to monitor corrosion online before structural integrity is compromised can have a significant impact on preventing catastrophic events resulting from corrosion. This article critically reviews conventional corrosion sensors and emerging sensor technologies in terms of sensing principles, sensor designs, advantages, and limitations. Conventional corrosion sensors encompass corrosion coupons, electrical resistance probes, electrochemical sensors, ultrasonic testing sensors, magnetic flux leakage sensors, electromagnetic sensors, and in-line inspection tools. Emerging sensor technologies highlight optical fiber sensors (point, quasi-distributed, distributed) and passive wireless sensors such as passive radio-frequency identification sensors and surface acoustic wave sensors. Emerging sensors show great potential in continuous real-time in-situ monitoring of oil and natural gas infrastructure. Distributed chemical sensing is emphasized based on recent studies as a promising method to detect early corrosion onset and monitor corrosive environments for corrosion mitigation management. Additionally, challenges are discussed including durability and stability in extreme and harsh conditions such as high temperature high pressure in subsurface wellbores.

passive RFID sensors↗

Calcined Polyethyleneimine Coated Optical Fibers for Distributed pH Monitoring at High Pressures and Temperatures

In the oil and gas, CO2 sequestration, H2 subsurface storage, and geothermal energy sectors, subsurface pH measurements are critical for monitoring the geochemical conditions and estimating potential corrosion rates of wellbore systems. Real-time pH measurements in these conditions are vital for detecting and predicting corrosion deterioration of wellbore components that may jeopardize the safety and continued operation of wellbore systems. Building off of earlier TiO2 based pH sensors and the known pH sensitivity of amine-based polymers, a coating based on the secondary amine polymer polyethyleneimine (PEI) was developed. The sensor coating was treated with a high temperature (500 °C) calcination procedure in air to convert it into a more stable oxidized coating capable of withstanding hot aqueous solutions without dissolving while retaining linear pH sensitivity from pH values between 2 and 11. The sensor performance was measured using optical transmission measurements in solutions of various pHs and using optical backscatter reflectometry for distributed pH sensing demonstration in wellbore-relevant pressures (up to 1000 psi) and temperatures (80 °C). A calibration curve with strong differentiation between acidic and alkaline pH was developed for both transmission-based and distributed pH measurements, using fixed wavelength transmission and integrated linear amplitude of backscattered light for distributed measurements.

Shumski, Alexander↗

Integrating Radio-Over-Fiber Communication System and BOTDR Sensor System

In this paper, we propose and experimentally demonstrate for the first time, the integration of a radio-over-fiber (RoF) communication system and a Brillouin optical time-domain reflectometry (BOTDR) distributed sensor system using a single optical fiber link. In this proof-of-concept integrated system, the communication system is composed of three modulation formats of quadrature phase-shift keying (QPSK), 16-quadrature amplitude modulation (16-QAM) and 64-QAM, which are modulated onto an orthogonal frequency division multiplexing (OFDM) signal. Whereas, the BOTDR sensor system is used for strain and/or temperature monitoring over the fiber distance with a spatial resolution of 5 m using a 25 km single-mode silica fiber. The error vector magnitude (EVM) is analyzed in three modulation formats in the presence of various BOTDR input pump powers. Using QPSK modulation, optimized 18 dBm sensing and 10 dBm data power, the measured EVM values with and without bandpass filter are 3.5% and 14.5%, respectively. The proposed system demonstrates a low temperature measurement error (±0.49 °C at the end of 25 km) and acceptable EVM values, which were within the 3GPP requirements. The proposed integrated system can be effectively applied for practical applications, which significantly reduces the fiber infrastructure cost by effective usage of a single optical fiber link.

42 ENGINEERING↗

Fiber optic and laser sensors IV; Proceedings of the Meeting, Cambridge, MA, Sept. 22-24, 1986

The conference presents papers on industrial uses of fiber optic sensors, point and distributed polarimetric optical fiber sensors, fiber optic electric field sensor technology, micromachined resonant structures, single-mode fibers for sensing applications, and measurement techniques for magnetic field gradient detection. Consideration is also given to electric field meter and temperature measurement techniques for the power industry, the calibration of high-temperature fiber-optic microbend pressure transducers, and interferometric sensors for dc measurands. Other topics include the recognition of colors and collision avoidance in robotics using optical fiber sensors, the loss compensation of intensity-modulating fiber-optic sensors, and an embedded optical fiber strain tensor for composite structure applications.

De Paula, Ramon P.↗

Micro-optical Distributed Sensors for Aero Propulsion Applications

The objective of this research is to develop micro-opto-mechanical system (MOMS)-based sensors for time- and space-resolved measurements of flow properties in aerodynamics applications. The measurement technique we propose uses optical resonances in dielectric micro-spheres that can be excited by radiation tunneling from optical fibers. It exploits the tunneling-induced and morphology-dependent shifts in the resonant frequencies. The shift in the resonant frequency is dependent on the size, shape, and index of refraction of the micro-sphere. A physical change in the environment surrounding a micro-bead can change one or more of these properties of the sphere thereby causing a shift in frequency of resonance. The change of the resonance frequency can be detected with high resolution by scanning a frequency-tunable laser that is coupled into the fiber and observing the transmission spectrum at the output of the fiber. It is expected that, in the future, the measurement concept will lead to a system of distributed micro-sensors providing spatial data resolved in time and space. The present project focuses on the development and demonstration of temperature sensors using the morphology-dependent optical resonances although in the latter part of the work, we will also develop a pressure sensor. During the period covered in this report, the optical and electronic equipment necessary for the experimental work was assembled and the experimental setup was designed for the single sensor temperature measurements. Software was developed for real-time tracking of the optical resonance shifts. Some preliminary experiments were also carried out to detect temperature using a single bead in a water bath.

Arnold, S.↗

Monitoring local heating around an interventional MRI antenna with RF radiometry

Purpose: Radiofrequency (RF) radiometry uses thermal noise detected by an antenna to measure the temperature of objects independent of medical imaging technologies such as magnetic resonance imaging (MRI). Here, an active interventional MRI antenna can be deployed as a RF radiometer to measure local heating, as a possible new method of monitoring device safety and thermal therapy. Methods: A 128 MHz radiometer receiver was fabricated to measure the RF noise voltage from an interventional 3 T MRI loopless antenna and calibrated for temperature in a uniformly heated bioanalogous gel phantom. Local heating (ΔT) was induced using the antenna for RF transmission and measured by RF radiometry, fiber-optic thermal sensors, and MRI thermometry. The spatial thermal sensitivity of the antenna radiometer was numerically computed using a method-of-moment electric field analyses. The gel’s thermal conductivity was measured by MRI thermometry, and the localized time-dependent ΔT distribution computed from the bioheat transfer equation and compared with radiometry measurements. A “H-factor” relating the 1 g-averaged ΔT to the radiometric temperature was introduced to estimate peak temperature rise in the antenna’s sensitive region. Results: The loopless antenna radiometer linearly tracked temperature inside a thermally equilibrated phantom up to 73 °C to within ±0.3 °C at a 2 Hz sample rate. Computed and MRI thermometric measures of peak ΔT agreed within 13%. The peak 1 g-average temperature was H = 1.36 ± 0.02 times higher than the radiometric temperature for any media with a thermal conductivity of 0.15–0.50 (W/m)/K, indicating that the radiometer can measure peak 1 g-averaged ΔT in physiologically relevant tissue within ±0.4 °C. Conclusions: Active internal MRI detectors can serve as RF radiometers at the MRI frequency to provide accurate independent measures of local and peak temperature without the artifacts that can accompany MRI thermometry or the extra space needed to accommodate alternative thermal transducers. A RF radiometer could be integrated in a MRI scanner to permit “self-monitoring” for assuring device safety and/or monitoring delivery of thermal therapy.

60 APPLIED LIFE SCIENCES↗

Explainable machine learning for incipient anomaly detection in compact molten salt heat exchanger with overlapping feature distributions

High-temperature molten salt-cooled reactors (MSCRs) are a promising next-generation nuclear technology option, offering efficient power conversion and inherent safety features. However, the reliability of these systems depends on the robust operation of heat exchangers (HXs), which are susceptible to failure due to temperature gradients and channel plugging caused by fluid freezing. Conventional monitoring methods, relying on inlet and outlet measurements, lack the spatial resolution needed to detect early-stage faults. We propose a novel design of a compact salt-to-salt matrix-type HX design consisting of interleaved arrays of parallel tubes, with integrated synthetic fiber optic distributed temperature sensing (DTS) to enable localized detection of incipient faults. To evaluate performance of this design, we generate high-fidelity synthetic data using heat transfer computational modeling to simulate channel plugging, and introduce sensor noise for realistic modeling of measurements. The dataset comprises of 97% normal operation and 3% anomaly cases, with each anomaly class representing 1% of the data. These early anomalies result in overlapping temperature profiles between normal and faulty channels, producing a non-separable dataset that challenges traditional classification techniques. We benchmark eight supervised machine learning (ML) models and demonstrate that XGBoost achieves the highest performance. To improve transparency, we develop an explainability framework combining Shapley values and partially ordered sets (POSETs) to quantify and structurally analyze feature importance. This approach identifies both dominant predictors and ambiguous feature relationships, enhancing trust and interpretability. Our results highlight the potential of combining DTS and explainable ML with intelligent feature selection to improve predictive maintenance and ensure operational resilience in advanced nuclear systems.

Prantikos, Konstantinos [Argonne National Laborato↗

Date Release Report for Large Surface Explosion Coupling Experiment (LSECE) Nevada National Security Site

The DTRA sponsored 2020-2022 Large Surface Explosion Coupling Experiment (LSECE) consists of two large ground surface chemical explosions, data collection, analysis and modeling carried out in 2020-2022. The LSECE chemical explosions were carried out at the site of prior NNSA sponsored buried chemical explosions that were part of the Source Physics Experiment (SPE) Phase II in Dry Alluvium Geology (DAG). This report described the data collected under LSECE that is being made publicly available. The prior buried explosion DAG data are described in a separate report (https://www.osti.gov/biblio/1825534) and are also publicly available. The LSECE explosions, data analysis and numerical modeling work sponsored by DTRA were intended to address three objectives: 1) Generate seismo-acoustic data to test and improve numerical models of explosion energy coupling in dry alluvium geology; 2) To improve seismo-acoustic yield estimation techniques as a function of depth and medium properties; 3) To study and improve acoustic propagation modeling under two different atmospheric conditions. The LSECE data that were collected have expanded the prior DAG buried explosion dataset to include surface chemical explosions recorded on a common set of seismo-acoustic stations. They have allowed a more detailed study of above and below surface seismo-acoustic energy coupling with applications to explosion monitoring and assessment. The two approximately 1-ton TNT equivalent yield LSECE explosions were detonated at different times of the day to explore the effects of the different atmospheric conditions. The first chemical explosion “Artemis” was conducted before dawn when temperature inversions were present. The second chemical explosion “Apollo” was conducted on a sunny afternoon when the temperature gradient was more linear. The LSECE chemical explosion data were also collected across a variety of different sensor types to allow evaluation of their effectiveness in recovering useful information. The LSECE instrumentation included fiber optic or Distributed Acoustic Sensing (DAS), a dense array or Large-N array of seismometers, borehole accelerometers, DAS and a velocity meter, airborne acoustic instruments and a variety of visual and remote sensing data.

58 GEOSCIENCES↗

Distributed Fiber Optic Arrays: Integrated Temperature and Seismic Sensing for Detection of CO 2 Flow, Leakage and Subsurface Distribution (Final Report)

This report describes the seismic and heat-pulse monitoring equipment, surveys, results and accomplishments of the fiber optic (FO) project funded by the U.S. Department of Energy (DOE) under Agreement Number DE-FE0012700. The formal title of the project is “Distributed Fiber Optic Arrays: Integrated Temperature and Seismic Sensing for Detection of CO 2 Flow, Leakage and Subsurface Distribution.” The project focuses on the field acquisition of FO data using Distributed Acoustic Sensing (DAS) arrays for subsurface imaging of geologic structure and to track the CO 2 migration in the injection interval using time-lapse techniques. A second component of the project uses a novel heat-pulse monitoring method that relies on Distributed Temperature Sensing (DTS) to evaluate near-field leakage of CO 2 or brine in and around the wellbore. The Southeast Regional Carbon Sequestration (SECARB) partnership hosted the project at the Anthropogenic Test site near Citronelle, Alabama after the original site host, the Kansas Geological Survey (KGS), experienced significant delays in permitting its CO 2 injection well at the Wellington Oil Field site in Kansas. The KGS project was later terminated in 2017 before an injection permit issued. A second field trial was planned for the Livingston Oil Field, located in Louisiana, but the site host ran into financial troubles and the project was terminated in 2015. A replacement field-site host was not found for the Livingston field trial. Both the Wellington, Kansas and Livingston, Louisiana projects were funded by DOE. A novel sensor platform referred to as the Modular Borehole Monitoring (MBM) system deployed at the Citronelle field site was utilized by the FO project. Two different seismic sensor technologies were incorporated in the Citronelle MBM system design including: (1) a semi-permanent, tubing-deployed, 18-level geophone array with custom hydraulic clamps; and (2) two, single mode optical fibers for Distributed Acoustic Sensing (DAS). Incorporation of the 18-level geophone array in the MBM system provided an ideal opportunity to compare the DAS response to conventional geophones. A heat-pulse monitoring system consisting of two, multi-mode optical fibers for Distributed Temperature Sensing (DTS) and copper heater element were also incorporated into the MBM package. This report provides an overview of the design of the MBM, DAS, and DTS equipment and the surveys performed during the study. The heat-pulse monitoring technique was used to diagnose a completion problem with observation well D-9-8 #2 where the MBM system was installed in 2012, thus successfully demonstrating its application for leak detection. In 2015, CO 2 unexpectedly arrived at the observation well approximately one year after CO 2 injection and heat-pulse monitoring ended. It was determined at this time that saltwater intrusion had likely penetrated the stainless-steel capillary tube containing the fibers and copper heater elements, thus preventing the heater from being used. DTS measurements indicated that the fiber had also degraded probably due to hydrogen darkening. It is recommended that the capillary tube be constructed of a more corrosive resistant material (e.g., Inconel) in the future should it be deployed in similar harsh downhole environments. Geophysical imaging of the subsurface and monitoring of the CO 2 were successful using DAS in the vertical seismic profile (VSP) survey configuration. A high resolution VSP image of the subsurface was obtained in 2014 using DAS, which exceeded our expectations in comparison to a lower resolution image obtained by SECARB in 2012 using an 80-level geophone array. A time-lapse image of the redistribution of CO 2 after injection ended in September 2014 was obtained using two DAS VSP surveys from June 2014 and December 2015, thus successfully demonstrating its application. DAS data were also acquired during a crosswell seismic survey conducted in 2014. Unfortunately, the DAS technique was not success in the crosswell survey configuration because the noise level was too high, increasing by a factor of ten, over the high frequency output (100-1,200) of the piezoelectric source.

58 GEOSCIENCES↗

Composite Cure Process Modeling and Simulations using COMPRO(Registered Trademark) and Validation of Residual Strains using Fiber Optics Sensors

Composite cure process induced residual strains and warping deformations in composite components present significant challenges in the manufacturing of advanced composite structure. As a part of the Manufacturing Process and Simulation initiative of the NASA Advanced Composite Project (ACP), research is being conducted on the composite cure process by developing an understanding of the fundamental mechanisms by which the process induced factors influence the residual responses. In this regard, analytical studies have been conducted on the cure process modeling of composite structural parts with varied physical, thermal, and resin flow process characteristics. The cure process simulation results were analyzed to interpret the cure response predictions based on the underlying physics incorporated into the modeling tool. In the cure-kinetic analysis, the model predictions on the degree of cure, resin viscosity and modulus were interpreted with reference to the temperature distribution in the composite panel part and tool setup during autoclave or hot-press curing cycles. In the fiber-bed compaction simulation, the pore pressure and resin flow velocity in the porous media models, and the compaction strain responses under applied pressure were studied to interpret the fiber volume fraction distribution predictions. In the structural simulation, the effect of temperature on the resin and ply modulus, and thermal coefficient changes during curing on predicted mechanical strains and chemical cure shrinkage strains were studied to understand the residual strains and stress response predictions. In addition to computational analysis, experimental studies were conducted to measure strains during the curing of laminated panels by means of optical fiber Bragg grating sensors (FBGs) embedded in the resin impregnated panels. The residual strain measurements from laboratory tests were then compared with the analytical model predictions. The paper describes the cure process procedures and residual strain predications, and discusses pertinent experimental results from the validation studies.

Sreekantamurthy, Thammaiah↗

Development of a fiber optic high temperature strain sensor

From 1 Apr. 1991 to 31 Aug. 1992, the Georgia Tech Research Institute conducted a research program to develop a high temperature fiber optic strain sensor as part of a measurement program for the space shuttle booster rocket motor. The major objectives of this program were divided into four tasks. Under Task 1, the literature on high-temperature fiber optic strain sensors was reviewed. Task 2 addressed the design and fabrication of the strain sensor. Tests and calibration were conducted under Task 3, and Task 4 was to generate recommendations for a follow-on study of a distributed strain sensor. Task 4 was submitted to NASA as a separate proposal.

Rausch, E. O.↗

Coated fiber optic chemical and radiation sensors

Distributed fiber optic chemical and radiation sensors formed by coating the fibers with certain types of response materials are provided. For distributed chemical sensors, the coatings are reactive with the targets; the heat absorbed or released during a reaction will cause a local temperature change on the fiber. For distributed radiation sensors, coating a fiber with a scintillator enhances sensitivity toward thermal neutrons, for example, by injecting light into the fiber. The luminescent components in these materials are taken from conjugated polymeric and oligomeric dyes, metal organic frameworks with sorbed dyes, and two-photon-absorbing semiconductors. The compositions may exhibit strong gamma rejection. Other scintillators combining luminescent materials with neutron converters are available. With a multiple-layer coating, it may be possible to identify the presence of both neutrons and gamma rays, for example. Coatings may be applied during manufacture or in the field.

Lamberti, Vincent E.↗

Initial Feasibility Assessment and Broader Strategy Development for Fiber Integration via Advanced Manufacturing

Structural health monitoring is critical for ensuring the operational safety and cost-competitiveness of the developing advanced reactor designs. The extreme operational envelopes of these advanced architectures, having operating temperatures ranging 400°C–1,000°C and heightened displacement damage doses, render conventional commercially available piezoelectric transducers and resistive strain gauges unviable. Optical fiber sensors present an attractive solution for advanced radiation-hardened instrumentation due to their high thermal stability and distributed sensing capabilities. However, their deployment in embedded applications can be hindered by the severe thermomechanical strain driven by the coefficient of thermal expansion mismatch between fused silica glass and structural metal alloys like stainless steel (e.g., SS316L).

36 MATERIALS SCIENCE↗

Segregation of Chromium and Titanium in Sapphire Optical Fiber Grown via the Laser-Heated Pedestal Growth Technique

Our research involves growth of single crystal (SC) optical fibers to be used for sensing applications in harsh environments. Silica optical fibers are an affordable and reliable option for a wide variety of applications including optical fiber sensors and fiber lasers. However, for applications in harsh environments, such as high temperatures, radioactivity, corrosivity, etc., silica fibers are not suitable due to their instability under such conditions. Fibers composed of SC materials such as sapphire and YAG are mechanically, chemically, and thermally more robust to harsh conditions, and thus are more appropriate for sensing applications in environments such as nuclear reactors, jet engines, and boiler. However, SC fibers grown via the laser-heated pedestal growth (LHPG) technique do not intrinsically have a functional cladding layer. A cladding layer is required to reduce the modal volume for distributed sensing applications, to reduce frustrated total internal reflection induced by surface contact of the fiber in certain applications, and to improve transmissivity. Our lab investigates introduction of dopant materials during LHPG to induce an effective core-cladding structure while maintain the crystallinity of the host material. This process results in optical fiber that is not only robust to harsh environments, but also has improved optical properties for distributed sensor applications.

distributed sensing↗

Segregation of Chromium and Titanium in Sapphire Optical Fiber Grown via the Laser-Heated Pedestal Growth Technique

Our research involves growth of single crystal (SC) optical fibers to be used for sensing applications in harsh environments. Silica optical fibers are an affordable and reliable option for a wide variety of applications including optical fiber sensors and fiber lasers. However, for applications in harsh environments, such as high temperatures, radioactivity, corrosivity, etc., silica fibers are not suitable due to their instability under such conditions. Fibers composed of SC materials such as sapphire and YAG are mechanically, chemically, and thermally more robust to harsh conditions, and thus are more appropriate for sensing applications in environments such as nuclear reactors, jet engines, and boiler. However, SC fibers grown via the laser-heated pedestal growth (LHPG) technique do not intrinsically have a functional cladding layer. A cladding layer is required to reduce the modal volume for distributed sensing applications, to reduce frustrated total internal reflection induced by surface contact of the fiber in certain applications, and to improve transmissivity. Our lab investigates introduction of dopant materials during LHPG to induce an effective core-cladding structure while maintain the crystallinity of the host material. This process results in optical fiber that is not only robust to harsh environments, but also has improved optical properties for distributed sensor applications.

distributed sensing↗

Intrinsic Fiber Optic Chemical Sensors for Subsurface Detection of CO 2

Intelligent Optical Systems, Inc. has developed distributed intrinsic fiber optic sensors to directly quantify the concentration of dissolved or gas-phase CO 2 for leak detection or plume migration in carbon capture and sequestration (CCS). The capability of the sensor for highly sensitive detection of CO 2 in the pressure and temperature range of 15 to 2,000 psi and 25°C to 175°C was demonstrated, as was the capability of operating in highly corrosive and contaminated environments such as those often found in CO 2 injection sites. The novel sensor system was for the first time demonstrated deployed in a deep well, detecting multiple CO 2 releases, in real time, at varying depths. Early CO 2 release detection, by means of a sensor cable integrating multiple sensor segments, was demonstrated, as was the capability of quantifying the leak. The novel fiber optic sensor system exhibits capabilities not achieved by any other monitoring technology. This project represents a breakthrough in monitoring capabilities for CCS applications.

54 ENVIRONMENTAL SCIENCES↗