Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Fiber Lens”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

159 records · Page 9

Digital angular position sensor using wavelength division multiplexing

Future aircraft will use fly-by-light control systems with fiber-linked optical sensors for such measurands as temperature, pressure, and linear and angular position. A digital optical sensor is described which was developed to transmit the angular position of such slowly rotating parts as a throttle of fuel flow control valve on an aircraft. The sensor employs a reflective code plate with ten channels providing a resolution of 0.35 degrees. Two light-emitting diodes with overlapping spectra are used as light sources. A single microoptic multiplexer-demultiplexer composed of a GRIN rod lens and a miniature grating is used to disperse the spectrum and recombine the spectral components from each channel after reflection by the code plate. The results of preliminary environmental tests of this unit are discussed. The sensor has been operated for brief periods of time between -60 C and +125 without adverse effects. Preliminary vibration tests indicate that the unit will work properly at the maximum vibration levels expected in a jet-engine environment.

Fritsch, Klaus↗

Laboratory-based micro-X-ray fluorescence setup using a von Hamos crystal spectrometer and a focused beam X-ray tube

The high-resolution von Hamos bent crystal spectrometer of the University of Fribourg was upgraded with a focused X-ray beam source with the aim of performing micro-sized X-ray fluorescence (XRF) measurements in the laboratory. The focused X-ray beam source integrates a collimating optics mounted on a low-power micro-spot X-ray tube and a focusing polycapillary half-lens placed in front of the sample. The performances of the setup were probed in terms of spatial and energy resolution. In particular, the fluorescence intensity and energy resolution of the von Hamos spectrometer equipped with the novel micro-focused X-ray source and a standard high-power water-cooled X-ray tube were compared. The XRF analysis capability of the new setup was assessed by measuring the dopant distribution within the core of Er-doped SiO{sub 2} optical fibers.

36 MATERIALS SCIENCE↗

Performance of the Microwave Anisotropy Probe AST-201 Star Trackers

The Microwave Anisotropy Probe (MAP) was launched to create a full-sky map of the cosmic microwave background. MAP incorporates two modified Lockheed Martin AST-201 (Autonomous Star Tracker) star trackers. The AST-201 employs an eight element radiation hardened lens assembly which is used to focus an image on a charge coupled device (CCD). The CCD image is then processed by a star identification algorithm which outputs a three-axis attitude. A CCD-shift algorithm called Time Delayed Integration (TDI) was also included in each star tracker. In order to provide some radiation effect filtering during MAP's three to five phasing loop passes through the Van Allen radiation belts, a simple pixel filtering scheme was implemented, rather than using a more complex, but more robust windowing algorithm. The trackers also include a fiber optic data interface. This paper details the ground testing that was accomplished on the MAP trackers.

Ward, David K.↗

First indirect x-ray imaging tests with an 88-mm diameter single crystal

Using the 1-BM-C beamline at the Advanced Photon Source (APS), we have performed the initial indirect x - ray imaging point-spread-function (PSF) test of a unique 88-mm diameter YAG:Ce single crystal of only 100 - micron thickness. The crystal was bonded to a fiber optic plat e (FOP) for mechanical support and to allow the option for FO coupling to a large format camera. This configuration resolution was compared to that of self - supported 25-mm diameter crystals, with and without an Al reflective coating. An upstream monochromator was used to select 17-keV x-rays from the broadband APS bending magnet source of synchrotron radiation. The upstream , adjustable Mo collimators were then used to provide a series of x-ray source transverse sizes from 200 microns down to about 15-20 microns (FWHM) at the crystal surface. The emitted scintillator radiation was in this case lens coupled to the ANDOR Neo sCMOS camera, and the indirect x-ray images were processed offline by a MATLAB - based image processing program. Based on single Gaussian peak fits to the x-ray image projected profiles, we observed a 10.5 micron PSF. This sample thus exhibited superior spatial resolution to standard P43 polycrystalline phosphors of the same thickness which would have about a 100-micron PSF. Lastly, this single crystal resolution combined with the 88-mm diameter makes it a candidate to support future x-ray diffraction or wafer topography experiments.

43 PARTICLE ACCELERATORS↗

Infrared thermography NDT for in-situ defect detection in sandwich composite panel manufacturing

Composite manufacturing presents numerous challenges, as defects can arise from various sources throughout the process. In sandwich composite structures, the integration of a foam core introduces additional complexity and increases the likelihood of defect formation like delamination. To mitigate these issues and reduce the risk of future structural failures, in-situ monitoring during manufacturing is essential. This study investigates infrared (IR) thermography as a non-destructive technique for detecting manufacturing defects in foam-core sandwich composite panels under thermally excited conditions representative of in-situ processing. A stationary FLIR A8590 IR camera (640 × 512 pixels, 30Hz, 17mm lens, 9 ft stand-off distance) was used to monitor prefabricated panels subjected to controlled external heating simulating compression molding and resin cure exotherm. Interlaminar delamination defects with characteristic sizes ranging from 0.25 × 0.25in² to 5 × 5in² produced measurable surface temperature depressions of approximately 4–10°C during transient cooling, exceeding the effective noise floor of the camera by more than two standard deviations. Thicker laminates exhibited prolonged defect detectability windows due to increased thermal diffusion time. In contrast, embedded Teflon inclusions generated weak thermal contrasts of ≤ 3°C, approaching the measurement noise floor, due to limited thermal property contrast with the surrounding glass fiber composite. These results establish quantitative detectability limits for stationary thermographic inspection of sandwich composite panels under manufacturing-representative thermal cycles.

Barakat, Abdallah [ORNL] (ORCID:0000000296141398)↗

Calculation and experimental verification of a collimator with a Kerr lens for fibre laser mode locking

We present the calculation and experimental verification of the operation of a collimator coupling a light beam into an optical fibre with an As{sub 2}S{sub 3} nonlinear plate. It is shown that a Kerr lens formed in the plate with an increase in the peak pulse power leads to an increase in the output coupling ratio by about 15%, which can be used for the passive mode locking of a fibre laser. (lasers)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The Effect of a Pre-Lens Aperture on the Temperature Range and Image Uniformity of Microbolometer Infrared Cameras

This paper explores the temperature range extension of long-wavelength infrared (LWIR) cameras by placing an aperture in front of the lens. An aperture smaller than the lens will reduce the radiance to the sensor, allowing the camera to image targets much hotter than typically allowable. These higher temperatures were accurately determined after developing a correction factor which was applied to the built-in temperature calibration. The relationship between aperture diameter and temperature range is linear. The effect of pre-lens apertures on the image uniformity is a form of anti-vignetting, meaning the corners appear brighter (hotter) than the rest of the image. An example of using this technique to measure temperatures of high melting point polymers during 3D printing provide valuable information of the time required for the weld-line temperature to fall below the glass transition temperature.

3D Printing↗

Diffractive Combiner of Single-Mode Pump Laser-Diode Beams

An optical beam combiner now under development would make it possible to use the outputs of multiple single-mode laser diodes to pump a neodymium: yttrium aluminum garnet (Nd:YAG) nonplanar ring oscillator (NPRO) laser while ensuring that the laser operates at only a single desired frequency. Heretofore, an Nd:YAG NPRO like the present one has been pumped by a single multimode laser-diode beam delivered via an optical fiber. It would be desirable to use multiple pump laser diodes to increase reliability beyond that obtainable from a single pump laser diode. However, as explained below, simplistically coupling multiple multimode laser-diode beams through a fiber-optic combiner would entail a significant reduction in coupling efficiency, and lasing would occur at one or more other frequencies in addition to the single desired frequency. Figure 1 schematically illustrates the principle of operation of a laser-diode-pumped Nd:YAG NPRO. The laser beam path is confined in a Nd:YAG crystal by means of total internal reflections on the three back facets and a partial-reflection coating on the front facet. The wavelength of the pump beam - 808 nm - is the wavelength most strongly absorbed by the Nd:YAG crystal. The crystal can lase at a wavelength of either 1,064 nm or 1,319 nm - which one depending on the optical coating on the front facet. A thermal lens effect induced by the pump beam enables stable lasing in the lowest-order transverse electromagnetic mode (the TEM00 mode). The frequency of this laser is very stable because of the mechanical stability of the laser crystal and the unidirectional nature of the lasing. The unidirectionality is a result of the combined effects of (1) a Faraday rotation induced by an externally applied magnetic field and (2) polarization associated with non-normal incidence and reflection on the front facet.

Liu, Duncan↗

Interpreting the Strain Tensor During Injection into a Reservoir

A suite of well tests was conducted to evaluate the feasibility of measuring and interpreting the strain tensor during injection. Water was injected at 1 liter/s for a few days to a few weeks into a well completed at a depth of 530 m in the Bartlesville sandstone in the North Avant Field in Oklahoma. The strain tensor was measured using strainmeters at a depth of 30m and a distance of 220m from the well. We used a Gladwin strainmeter, a state-of-the-art geodetic strainmeter, as well as novel borehole strainmeters developed for the project. After processing, the horizontal strains were tensile and the vertical strain was compressive during injection. The radial strain was less than the circumferential strain. Strain magnitudes increased during injection and recovered afterward. The strain rate was as fast as 100 nanostrain/d at the start of injection, and decreased to 10 nanostrain/d after a few days. The normal strain signals were approximately proportional to the log of time during the first few days of injection, and the semi-log slope was 50 to 75 nanostrain. Data from the Gladwin strainmeter were essentially identical to data from a strainmeter we developed using optical fiber sensors. Tilt was measured using two tiltmeters, but the tilts were erratic compared to the normal strain and were of limited value. Strain data were analyzed using a strain type-curve method, an analytical solution to a poroelastic inhomogeneity, and a stochastic inversion method. Poroelastic simulations explain the data well. Results from the interpretation methods are consistent with each other, and with independent information characterizing the area. The hydraulic diffusivity is approximately 0.5 m2/s and the permeability is between 100 and 500 mD, according to analysis of the strain signals. This is consistent with measurements of permeability from cores, and with analyses of pressure transients. The analyses indicate that Young’s modulus of the reservoir is between 2 and 6 GPa. Strain interpretations indicate the well intersects a permeable lens with a maximum dimension of 500 to 1,000 m. An isopach map of coarse-grained sand confirms a feature roughly 1,000 m in lateral extent. The results demonstrate that the strain signal measured at shallow (30m) depth can be used to infer properties and heterogeneities in an underlying reservoir or aquifer.

Murdoch, Larry↗

Embryonic development of the cornea in the eye of the clearnose skate, Raja eglanteria: I. Stromal development in the absence of an endothelium

Embryos of the clearnose skate, Raja eglanteria, develop in sea water at 20-22 degrees C, hatching after 82 +/- 4 days (Luer and Gilbert, Environ. Biol. Fishes, 13:161-171, 1985). Eyes develop as steadily enlarging spheres whose corneas have the same radius of curvature as the sclera. The cornea begins development as a 2-cell thick epithelium beneath which by Day 12 there is only a basal lamina and a wispy matrix separating it from the underlying lens. This matrix, modified by Day 16, is displaced on Day 22 by a few orthogonal plies of fibrillar primary stroma. Ply number increases to at least 13 by Day 30, reaching the final number of 20 +/- 2 by Day 42. Stromal fibroblasts (keratocytes) appear at the corneal periphery by Day 22, and in increased numbers by Day 30, a time at which no keratocytes are seen in the central stroma. However, by Day 40, many fibroblasts are present at the corneal periphery, invading the primary stroma between plies, occasionally reaching even the central cornea. By Day 53, keratocytes are present between all plies, from corneal periphery to center. Thickness of each ply in this secondary stroma increases, but the number of plies remains the same as in the primary stroma. Bowman's layer, non-invaded matrix beneath the epithelial basal lamina, is not evident until Day 53. Sutural fibers, first seen on Day 22, originate in the corneal epithelial basal lamina, traversing perpendicularly the plies of the primary stroma. Sutural fibers persist throughout development of the secondary stroma and into adulthood. In contrast to chicks, skate corneas remain transparent throughout development, and never form an endothelium.

Non-NASA Center↗

NASA Tech Briefs, January 2012

Contents of this issue are: (1) Energy-Based Tetrahedron Sensor for High-Temperature, High-Pressure Environments (2) Handheld Universal Diagnostic Sensor (3) Large-Area Vacuum Ultraviolet Sensors (4) Fiber Bragg Grating Sensor System for Monitoring Smart Composite Aerospace Structures (5) Health-Enabled Smart Sensor Fusion Technology (6) Extended-Range Passive RFID and Sensor Tags (7) Hybrid Collaborative Learning for Classification and Clustering in Sensor Networks (8) Self-Healing, Inflatable, Rigidizable Shelter (9) Improvements in Cold-Plate Fabrication (10) Technique for Radiometer and Antenna Array Calibration - TRAAC (11) Real-Time Cognitive Computing Architecture for Data Fusion in a Dynamic Environment (12) Programmable Digital Controller (13) Use of CCSDS Packets Over SpaceWire to Control Hardware (14) Key Decision Record Creation and Approval Module (15) Enhanced Graphics for Extended Scale Range (16) Debris Examination Using Ballistic and Radar Integrated Software (17) Data Distribution System (DDS) and Solar Dynamic Observatory Ground Station (SDOGS) (18) Integration Manager (19) Eclipse-Free-Time Assessment Tool for IRIS (20) Automated and Manual Rocket Crater Measurement Software (21) MATLAB Stability and Control Toolbox Trim and Static Stability Module (22) Patched Conic Trajectory Code (23) Ring Image Analyzer (24) SureTrak Probability of Impact Display (25) Implementation of a Non-Metallic Barrier in an Electric Motor (26) Multi-Mission Radioisotope Thermoelectric Generator Heat Exchangers for the Mars Science Laboratory Rover (27) Uniform Dust Distributor for Testing Radiative Emittance of Dust-Coated Surfaces (28) MicroProbe Small Unmanned Aerial System (29) Highly Stable and Active Catalyst for Sabatier Reactions (30) Better Proton-Conducting Polymers for Fuel-Cell Membranes (31) CCD Camera Lens Interface for Real-Time Theodolite Alignment (32) Peregrine 100-km Sounding Rocket Project (33) SOFIA Closed- and Open-Door Aerodynamic Analyses (34) Sonic Thermometer for High-Altitude Balloons (35) Near-Infrared Photon-Counting Camera for High-Sensitivity Observations (36) Integrated Optics Achromatic Nuller for Stellar Interferometry (37) High-Speed Digital Interferometry (38) Ultra-Miniature Lidar Scanner for Launch Range Data Collection (39) Shape and Color Features for Object Recognition Search (40) Explanation Capabilities for Behavior-Based Robot Control (41) A DNA-Inspired Encryption Methodology for Secure, Mobile Ad Hoc Networks (42) Quality Control Method for a Micro-Nano-Channel Microfabricated Device (43) Corner-Cube Retroreflector Instrument for Advanced Lunar Laser Ranging (44) Electrospray Collection of Lunar Dust (45) Fabrication of a Kilopixel Array of Superconducting Microcalorimeters with Microstripline Wiring Spacecraft Attitude Tracking and Maneuver Using Combined Magnetic Actuators (46) Coherent Detector for Near-Angle Scattering and Polarization Characterization of Telescope Mirror Coatings

Source record↗

NASA Tech Briefs, January 2011

The topics include: 1) Distributed Aerodynamic Sensing and Processing Toolbox; 2) Collaborative Supervised Learning for Sensor Networks; 3) Hazard Detection Software for Lunar Landing; 4) Onboard Nonlinear Engine Sensor and Component Fault Diagnosis and Isolation Scheme; 5) Network-Capable Application Process and Wireless Intelligent Sensors for ISHM; 6) Interface Supports Multiple Broadcast Transceivers for Flight Applications; 7) FPGA Sequencer for Radar Altimeter Applications; 8) Miniature Sapphire Acoustic Resonator - MSAR; 9) Process-Hardened, Multi-Analyte Sensor for Characterizing Rocket Plume Constituents; 10) SAD5 Stereo Correlation Line-Striping in an FPGA; 11) Hybrid Composite Cryogenic Tank Structure; 12) Nanoscale Deformable Optics; 13) Reliability-Based Design Optimization of a Composite Airframe Component; 14) Zinc Oxide Nanowire Interphase for Enhanced Lightweight Polymer Fiber Composites; 15) Plasma Igniter for Reliable Ignition of Combustion in Rocket Engines; 16) Wire Test Grip Fixture; 17) A Sub-Hertz, Low-Frequency Vibration Isolation Platform; 18) Carbon Nanofibers Synthesized on Selective Substrates for Nonvolatile Memory and 3D Electronics; 19) Nanoparticle/Polymer Nanocomposite Bond Coat or Coating; 20) High-Resolution Wind Measurements for Offshore Wind Energy Development; 21) Spring Tire; 22) Marsviewer 2008; 23) Mission Services Evolution Center Message Bus; 24) Major Constituents Analysis for the Vehicle Cabin Atmosphere Monitor; 25) Astronaut Health Participant Summary Application; 26) Adaption of the AMDIS Method to Flight Status on the VCAM Instrument; 27) Natural Language Interface for Safety Certification of Safety-Critical Software; 28) Cryogenic Caging for Science Instrumentation; 29) Wide-Range Neutron Detector for Space Nuclear Applications; 30) In Situ Guided Wave Structural Health Monitoring System; 31) Multiplexed Energy Coupler for Rotating Equipment; 32) Attitude Estimation in Fractionated Spacecraft Cluster Systems; 33) Full Piezoelectric Multilayer-Stacked Hybrid Actuation/Transduction Systems; 34) Active Flow Effectors for Noise and Separation Control; 35) Method and System for Temporal Filtering in Video Compression Systems; 36) Apparatus for Measuring Total Emissivity of Small, Low-Emissivity Samples; 37) Multiple-Zone Diffractive Optic Element for Laser Ranging Applications; 38) Simplified Architecture for Precise Aiming of a Deep-Space Communication Laser Transceiver; 39) Two-Photon-Absorption Scheme for Optical Beam Tracking; 40) High-Sensitivity, Broad-Range Vacuum Gauge Using Nanotubes for Micromachined Cavities; 41) Wide-Field Optic for Autonomous Acquisition of Laser Link; 42) Extracting Zero-Gravity Surface Figure of a Mirror; 43) Modeling Electromagnetic Scattering From Complex Inhomogeneous Objects; 44) Visual Object Recognition and Tracking of Tools; 45) Method for Implementing Optical Phase Adjustment; 46) Visual SLAM Using Variance Grid Maps; 47) Rapid Calculation of Spacecraft Trajectories Using Efficient Taylor Series Integration; 48) Efficient Kriging Algorithms; 49) Predicting Spacecraft Trajectories by the WeavEncke Method; 50) An Augmentation of G-Guidance Algorithms; 51) Comparison of Aircraft Icing Growth Assessment Software; 52) Silicon-Germanium Voltage-Controlled Oscillator at 105 GHz; 53) Estimation of Coriolis Force and Torque Acting on Ares-1; 54) Null Lens Assembly for X-Ray Mirror Segments; and 55) High-Precision Pulse Generator.

Source record↗

Sub-2 Kelvin Characterization of Nitrogen-Vacancy Centers in Silicon Carbide Nanopillars

The development of efficient quantum communication technologies depends on the innovation in multiple layers of its implementation, a challenge we address from the fundamental properties of the physical system at the nanoscale to the instrumentation level at the macroscale. We select a promising near-infrared quantum emitter, the nitrogen-vacancy (NV) center in 4H-SiC, and integrate it, at an ensemble level, with nanopillar structures that enhance photon collection efficiency into an objective lens. Moreover, changes in collection efficiency in pillars compared to bulk can serve as indicators of color center orientation in the lattice. To characterize NV center properties at the unprecedented sub-2 K temperatures, we incorporate compatible superconducting nanowire single photon detectors inside the chamber of an optical cryostat and create the ICECAP, the Integrated Cryogenic system for Emission, Collection And Photon detection. ICECAP measurements show no significant line-width broadening of NV ensemble emission and up to 14-fold enhancement in collected emission. With additional filtering, we measure emitter lifetimes of NV centers in a basal ( hk ) and axial ( kk ) orientation, unveiling their cryogenic values of 2.2 and 2.8 ns.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Characterizing degraded visual environments with scanning lenses to improve contrast recovery

Atmospheric aerosols, such as fog and smoke, degrade optical signals via the scattering and absorption of light, making it difficult to recover information from the surrounding environment. Here, we present a technique that measures the angular distribution of light in scattering environments to help recover these degraded optical signals. This is done by passing a collimated beam through the aerosol environment and collecting the scattered and unscattered light with an f-theta scan lens. The lens transforms the angular distribution of the scattered light into the linear domain, mapping the collected light onto a detector. The measured angular scattering distribution is then used to estimate the point spread function of the environment at an arbitrary stand-off distance. This point spread function can be used to deconvolve images blurred by the aerosol environment in which the angular scattering distribution was initially measured. With this approach, we demonstrate improvements in the effective resolution of deblurred images up to 26% over a 120-cm stand-off distance. Experimentation was performed in the Sandia National Laboratories tabletop fog chamber, a platform that generates aerosol environments analogous to real-world fogs. We intend to leverage this technique in future work to develop a low-SWaP system for the in situ characterization of aerosol environments.

Aerosols↗