Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Fermilab”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

EOS at the Fermilab LHC Physics Center(LPC)

The Fermilab CMS LPC center has operated an EOS instance since initial testing began in June 2012, transitioning to production storage in 2013 with an initial capacity of 600\,TB. Today, the system provides approximately 16\,PB of storage to support the 4{,}500-core LPC user analysis cluster, which serves several hundred active CMS users at any given time. In this talk, we will provide an update on our system setup and outline near-term plans for the CMS LPC production EOS system. We will share operational experiences from running our EOS system over the past year. Additionally, we will briefly discuss our recent efforts within the Fermilab Disk Evolution Project to consider the future architecture of HEP data storage at Fermilab for the HL-LHC era.

Wu, Yujun↗

Measurement of Light-antiquark Flavor Asymmetry by Drell–Yan Experiment SeaQuest at Fermilab

The amounts of \(\bar{d}\) and \(\bar{u}\) in the proton were expected to be the same based on the flavor independence of gluon splitting. However, muon deep inelastic scattering experiment NMC at CERN found that the amount of \(\bar{d}\) is larger than \(\bar{u}\) in the proton. Bjorken x dependence of the sea quark flavor asymmetry can be studied in Drell–Yan experiments. The E866 experiment at Fermilab showed that \(\bar{d}(x)/\bar{u}(x) > 1.0\) at \(0.015 < x < 0.20\). SeaQuest at Fermilab measures the light-antiquark flavor asymmetry \(\bar{d}/\bar{u}\) precisely in a large x range (\(0.15 < x < 0.45\)) including the unrevealed region in E866. It uses a 120 GeV proton beam extracted from Fermilab Main Injector colliding with liquid hydrogen and deuterium targets to measure the Drell–Yan process. The light-antiquark flavor asymmetry \(\bar{d}(x)/\bar{u}(x)\) is derived from the cross section ratio of proton–deuteron to proton–proton Drell–Yan processes. SeaQuest released the preliminary result in 2016. The analyses toward final results are in progress.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Spin Tracking of Polarized Protons in the Main Injector at Fermilab

The Main Injector (MI) at Fermilab currently produces high-intensity beams of protons at energies of 120 GeV for a variety of physics experiments. Acceleration of polarized protons in the MI would provide opportunities for a rich spin physics program at Fermilab. To achieve polarized proton beams in the Fermilab accelerator complex, shown in Fig.1.1, detailed spin tracking simulations with realistic parameters based on the existing facility are required. This report presents studies at the MI using a single 4-twist Si-berian snake to determine the depolarizing spin resonances for the relevant synchrotrons. Results will be presented first for a perfect MI lattice, followed by a lattice that includes the real MI imperfections, such as the measured magnet field errors and quadrupole misalignments. The tolerances of each of these factors in maintaining polariza-tion in the Main Injector will be discussed.

Xiao, M.↗

Progress Towards Doubling the Beam Power at Fermilab's Accelerator Complex

After a 16 month shutdown to reconfigure the Fermilab Accelerators for high power operations, the Fermilab Accelerator Complex is again providing beams for numerous Physics Experiments. By using the Recycler to slip stack protons while the Main Injector is ramping, the beam power at 120 GeV can reach 700 KW, a factor of 2 increase. The progress towards doubling the Fermilab's Accelerator complex beam power will be presented.

43 PARTICLE ACCELERATORS↗

Perpendicular Biased Ferrite Tuned Cavities for the Fermilab Booster

The aging Fermilab Booster RF system needs an upgrade to support future experimental program. The important feature of the upgrade is substantial enhancement of the requirements for the accelerating cavities. The new requirements include enlargement of the cavity beam pipe aperture, increase of the cavity voltage and increase in the repetition rate. The modification of the present traditional parallel biased ferrite cavities is rather challenging. An alternative to rebuilding the present Fermilab Booster RF cavities is to design and construct new perpendicular biased RF cavities, which potentially offer a number of advantages. An evaluation and a preliminary design of the perpendicular biased ferrite tuned cavities for the Fermilab Booster upgrade is described in the paper. Also it is desirable for better Booster performance to improve the capture of beam in the Booster during injection and at the start of the ramp. One possible way to do that is to flatten the bucket by introducing second harmonic cavities into the Booster. This paper also looks into the option of using perpendicularly biased ferrite tuners for the second harmonic cavities.

43 PARTICLE ACCELERATORS↗

Design Considerations for Proposed Fermilab Integrable RCS

Integrable optics is an innovation in particle accelerator design that provides strong nonlinear focusing while avoiding parametric resonances. One promising application of integrable optics is to overcome the traditional limits on accelerator intensity imposed by betatron tune-spread and collective instabilities. The efficacy of high-intensity integrable accelerators will be undergo comprehensive testing over the next several years at the Fermilab Integrable Optics Test Accelerator (IOTA) and the University of Maryland Electron Ring (UMER). We propose an integrable Rapid-Cycling Synchrotron (iRCS) as a replacement for the Fermilab Booster to achieve multi-MW beam power for the Fermilab high-energy neutrino program. We provide a overview of the machine parameters and discuss an approach to lattice optimization. Integrable optics requires arcs with integer-pi phase advance followed by drifts with matched beta functions. We provide an example integrable lattice with features of a modern RCS - long dispersion-free drifts, low momentum compaction, superperiodicity, chromaticity correction, separate-function magnets, and bounded beta functions.

43 PARTICLE ACCELERATORS↗

Virtual Facility at Fermilab: Infrastructure and Services Expand to Public Clouds

In preparation for its new Virtual Facility Project, Fermilab has launched a program of work to determine the requirements for running a computation facility on-site, in public clouds, or a combination of both. This program builds on the work we have done to successfully run experimental workflows of 1000-VM scale both on an on-site private cloud and on Amazon AWS. To do this at scale we deployed dynamically launched and discovered caching services on the cloud. We are now testing the deployment of more complicated services on Amazon AWS using native load balancing and auto scaling features they provide. The Virtual Facility Project will design and develop a facility including infrastructure and services that can live on the site of Fermilab, off-site, or a combination of both. We expect to need this capacity to meet the peak computing requirements in the future. The Virtual Facility is intended to provision resources on the public cloud on behalf of the facility as a whole instead of having each experiment or Virtual Organization do it on their own. We will describe the policy aspects of a distributed Virtual Facility, the requirements, and plans to make a detailed comparison of the relative cost of the public and private clouds. Furthermore, this talk will present the details of the technical mechanisms we have developed to date, and the plans currently taking shape for a Virtual Facility at Fermilab.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Overview of the Liquid Argon Cryogenics for the Short Baseline Neutrino Program (SBN) at Fermilab

The Short-Baseline Neutrino (SBN) physics program will involve three LAr-TPC detectors located along the Booster Neutrino Beam (BNB) at Fermilab. This new SBN Program will deliver a rich and compelling physics opportunity, including the ability to resolve a class of experimental anomalies in neutrino physics and to perform the most sensitive search to date for sterile neutrinos at the eV mass-scale through both appearance and disappearance oscillation channels. The Program will be composed of an existing and operational detector known as Micro Boone (170 ton LAr mass) plus two new experiments known as the SBN Near Detector (SBND, ~ 260 ton) and the SBN Far Detector (SBN-FD, ~ 600 tons). Fermilab is now building two new facilities to house the experiments and incorporate all cryogenic and process systems to operate these detectors beginning in the 2018-2019 time frame. The SBN cryogenics are a collaborative effort between Fermilab and CERN. The SBN cryogenic systems for both detectors are composed of several sub-systems: External/Infrastructure (or LN2), Proximity (or LAr), and internal cryogenics. For each detector the External/Infrastructure cryogenics includes the equipment used to store and the cryogenic fluids needed for the operation of the Proximity cryogenics, including the LN2 and LAr storage facilities. The Proximity cryogenics consists of all the systems that take the cryogenic fluids from the external/infrastructure cryogenics and deliver them to the internal at the required pressure, temperature, purity and mass flow rate. It includes the condensers, the LAr and GAr purification systems, the LN2 and LAr phase separators, and the interconnecting piping. The Internal cryogenics is comprised of all the cryogenic equipment located within the cryostats themselves, including the GAr and LAr distribution piping and the piping required to cool down the cryostats and the detectors. These cryogenic systems will be engineered, manufactured, commissioned, and qualified by an international engineering team. This contribution presents the performance, the functional requirements and the modes of operation of the SBN cryogenics, and details the current status of the design, present and future needs.

Norris, Barry↗

Beam Based RF Voltage Measurements and Longitudinal Beam Tomography at the Fermilab Booster

Increasing proton beam power on neutrino production targets is one of the major goals of the Fermilab long term accelerator programs. In this effort, the Fermilab 8 GeV Booster synchrotron plays a critical role for at least the next two decades. Therefore, understanding the Booster in great detail is important as we continue to improve its performance. For example, it is important to know accurately the available RF power in the Booster by carrying out beam-based measurements in order to specify the needed upgrades to the Booster RF system. Since the Booster magnetic field is changing continuously measuring/calibrating the RF voltage is not a trivial task. Here, we present a beam based method for the RF voltage measurements. Data analysis is carried out using computer programs developed in Python and MATLAB. The method presented here is applicable to any RCS which do not have flat-bottom and flat-top in the acceleration magnetic ramps. We have also carried out longitudinal beam tomography at injection and extraction energies with the data used for RF voltage measurements. Beam based RF voltage measurements and beam tomography were never done before for the Fermilab Booster. The results from these investigations will be very useful in future intensity upgrades.

43 PARTICLE ACCELERATORS↗

The Fermilab Test Beam Facility Data Acquisition System Based on $otsdaq$

The Real-Time Systems Engineering Department of the Scientific Computing Division at Fermilab has deployed set of customizations to our Off-The-Shelf Data Acquisition solution (otsdaq) at the Fermilab Test Beam Facility (FTBF) to read out the beamline instrumentation in support of FTBF users. In addition to reading out several detectors which use various detection technologies and readout hardware, the FTBF Data Acquisition system (DAQ) can perform basic track reconstruction through the facility in real time and provide data to facility users. An advanced prototype smart coincidence module, known as the NIM+, performs trigger distribution and throttling, allowing the beamline instrumentation to be read out at different rates. Spill data are saved to disk for studies of the facility performance, and hit data are also made available on the FTBF network for experiments' use. A web-based run control and configuration GUI are provided, and the online monitoring snapshots created after each beam spill are viewable from any computer connected to the Fermilab network. The integrated DAQ system for the facility provides users with high-precision tracking data along the beamline and a single location for obtaining data from the facility detectors, which set the baseline for testing their own detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Advances and Enhancements in the Fabric for Frontier Experiments Project at Fermilab

The FabrIc for Frontier Experiments (FIFE) project within the Fermilab Scientific Computing Division is charged with integrating offline computing components into a common computing stack for the non-LHC Fermilab experiments, supporting experiment offline computing, and consulting on new, novel workflows. We will discuss the general FIFE onboarding strategy, the upgrades and enhancements in the FIFE toolset, and plans for the coming year. These enhancements include: expansion of opportunistic computing resources (including GPU and high-performance computing resources) available to experiments; assistance with commissioning computing resources at European sites for individual experiments; StashCache repositories for experiments; enhanced job monitoring tools; and a custom workflow management service. Additionally we have completed the first phase of a Federated Identity Management system to make it easier for FIFE users to access Fermilab computing resources.

Herner, Kenneth↗

The Status and Prospects of the Muon $g-2$ Experiment at Fermilab

The E989 Muon $g-2$ Experiment at Fermilab aims to measure the muon magnetic anomaly, $a_\mu$, to an unprecedented precision of 140 parts per billion (ppb), representing a four-fold improvement over the current best measurement, achieved at Brookhaven National Lab. There stands a greater than 3 standard deviations discrepancy between the Brookhaven measurement of $a_\mu$ and the theoretical value predicted using the Standard Model. The Fermilab experiment seeks to either resolve or confirm this discrepancy, which is suggestive of new physics interactions. To achieve the E989 target precision, the anomalous precession frequency of muons in a magnetic storage ring must be determined with a systematic uncertainty below 70\,ppb, and the average magnetic field experienced by these stored muons must be known equally well. The muon anomalous precession frequency is imprinted on the time-dependent energy distribution of decay positrons observed by 24 electromagnetic calorimeters. A suite of pulsed NMR probes continually monitors the magnetic field. This document presents the current status of the Fermilab experiment while emphasizing the ongoing analysis of the 2018 Run 1 dataset and the systematic effects that complicate it.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fermilab EP Facility Implovements

Electro-chemical Polishing (EP) is one of the key technologies of surface treatments for niobium superconducting cavities. Fermilab has established cold EP method and applied on all single cell cavities (1.3 GHz~3.9 GHz) processed at Fermilab EP facility. Cold EP method allows achieving continuous large current oscillations during EP process and providing the uniform removal over the cell with the variation of ±15%. Here we report details of Fermilab EP facility and cold EP method in this paper.

43 PARTICLE ACCELERATORS↗

Optimization of Clean Room Infrastructure and Procedure During LCLS-II Cryomodule Production at Fermilab

Optimization of Fermilab string assembly procedure and infrastructure has yielded a significant improvement of cryomodule particulate counts. Late production of LCLSII cryomodules were tested at CMTF at Fermilab and showed little to no x-ray up to administrative limit. The paper describes the field emission measurement instrumentation, field emission results of Fermilab’s LCLS-II cryomodules, clean room infrastructure upgrade and procedure optimization.

43 PARTICLE ACCELERATORS↗

Animation of Fermilab's Accelerator Complex

The 6,800-acre Fermilab site is home to a chain of particle accelerators that provide particle beams to numerous experiments and R&D programs. This 2-minute animation explains how the proton source provides the particles that get accelerated and travel through the accelerator complex at close to the speed of light. Scientists use these beams to generate protons, neutrons, muons, pions and neutrinos for various research areas across the Fermilab site. More than 4,000 scientists from over 50 countries use Fermilab and its particle accelerators, detectors and computers for their research. More information is at http://www.fnal.gov/pub/science/.

43 PARTICLE ACCELERATORS↗

Search for CPT and Lorentz invariance violation in the muon $g -2$ experiment at Fermilab

The Muon g-2 experiment at Fermilab (E989) aims to measure the anomalous magnetic moment of the muon, $a_{\mu}= (g-2)/2$, to a groundbreaking precision of $140$ ppb, obtaining a near four-fold increase in precision over the previous experiment, E821, at the Brookhaven National Laboratory (BNL). The value of $a_{\mu}$ from BNL currently differs from the Standard Model prediction by $\sim 3.7$ standard deviations, suggesting the potential for new physics and therefore, motivating a new experiment.Because the theory predicts this number with high precision, testing the g-factor through experiment provides a stringent test of the SM and can suggest physics beyond the Standard Model. The goal of the Fermilab Muon $g-2$ experiment is to increase the statistical precision by more than a factor of 20 and reduce systematic errors by a factor of 3. By measuring muon precession rate ($\omega_a$) in an external magnetic field, the anomalous magnetic moment will be calculated. This is an incredibly challenging experiment with a unique opportunity to provide new insight into nature. \\ The $g-2$ data also provides a great opportunity for setting the most stringent limits on some of the Standard Model Extension CPT Lorentz violating (LV) parameters in the muon sector. One of the CPT and Lorentz violating signatures that we can look for using $g-2$ data is a sidereal variation of $\omega_a(t)$. Extensive simulation studies confirm that the sensitivity regarding the sidereal varation roughly scales with $\omega_a$ uncertainty. Hence, the $g-2$ experiment at FNAL should be able to reach limits of $\sim 5\times10^{-25}$ GeV. Because the CPT and LV analyses are essentially studies of variations in $\omega_a$ as a function of time and charge, performing an $\omega_a$ analysis sets the stage for the CPT and LV measurement. This dissertation focuses on the methodology of a fully functioning framework and analyzing the Fermilab Muon $g - 2$ Run 2 data containing $\sim 11$ billion events above an energy threshold of $1.7$~GeV.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Operational Use of Ionization Profile Monitors in the Fermilab Main Injector

Ionization profile monitors (IPMs) are used in the Fermilab Main Injector (MI) to monitor injection lattice matching by measuring turn-by-turn sigmas at injection and to measure transverse emittance of the beam during the acceleration cycle. The IPMs provide a periodic, non-destructive means of performing turn-by-turn emittance measurements where other techniques are not applicable. As Fermilab is refocusing its attention on the intensity frontier, non-intercepting diagnostics such as IPMs are expected to become even more important. This paper gives an overview of the operational use of IPMs for emittance measurements and injection lattice matching measurements at Fermilab, and summarizes the future plans.

43 PARTICLE ACCELERATORS↗

Measurement of the muon spin precession frequency using the straw tracking detectors at the Fermilab Muon g-2 experiment

The measurement of the anomalous magnetic dipole moment of the muon ($a_{\mu}$) has long stood as an excellent precision test of the Standard Model (SM). The Fermilab Muon g-2 experiment has recently finished data-taking and in July 2023 published its latest determination of $a_\mu$ with a world-leading precision of 0.2\,ppm. In this publication, it surpassed the systematic uncertainty goal defined in the TDR. The analyses of a dataset approximately four times larger than this recent publication is now underway. The principle measurement of the Muon g-2 experiment measures $a_{\mu}$ by taking the ratio of two frequencies; the anomalous precession frequency ($\omega_a$) and the muon-weighted magnetic field of the experiment's storage ring measured from the precession frequency of protons in water using nuclear magnetic resonance (NMR) probes. In all publications to date, $\omega_a$ has been determined using energy deposits in the 24 calorimeters. However, the Fermilab experiment has t wo straw tracker detectors measuring the time and momentum of charged particles which can in principle also be used to to measure $\omega_a$ and such a measurement can provide an invaluable cross-check of the calorimeter result with different, and reduced, systematic uncertainties. This thesis presents the first (blinded) determination of $\omega_a$ using just charged tracks from the straw tracking detectors as opposed to calorimeter energy deposits. This analysis was undertaken using the Run-2/3 dataset which represents approximately 25\% of the final dataset. A total uncertainty of 2.19\,ppm on $\omega_a$ was obtained which is dominated by the statistical uncertainty of 2.16\,ppm. Additionally two new methodologies important to the analysis of the straw tracking data have been developed: one to better determine the track arrival time ($t_0$) and one to determine the level of pileup in the tracking detectors. The new $t_0$ algorithm which incorporates angular information improves t he resolution on the determination of the $t_0$ by a factor of two and results in 19\% more tracks being successfully reconstructed. The data from the trackers is also used to determine the beam profile that weights the magnetic field in the determination of $a_\mu$ and in determining several of the systematic uncertainties in the calorimeter-based $\omega_a$ analysis. A detailed study of the impact of the internal alignment of the tracker, the $t_0$ and pileup on the determination of the beam position was undertaken and propagated through to an uncertainty in the $\omega_a$ determination. These uncertainties were used in the Fermilab Muon g-2 experiment's recent publication in Phys. Rev. Lett.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗