Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Fermi acceleration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Ensuring High-Purity Liquid Argon for the LBNF FDC: Collaborative Cryogenics Research Between UNICAMP and Fermilab

Ensuring High-Purity Liquid Argon for the LBNF FDC: Collaborative Cryogenics Research Between UNICAMP and Fermilab R. Doubnik1, M. Adamowski1, F. de M. Blaszczyk1, A. Hahn1, D. Montanari1, R. Mrowca1, Z. West1, C. Adriano2, T. P.M. Alegre2, D. Correia2, A. A. B. Machado2, E. Segreto2, R. G. Gonçalves3, E. M. Assaf6, J. M. Assaf3, D. Cardoso3, M. B. Fontes4, H. Da Motta4, D. Noriler5, P. J. G. Pagliuso2. 1 Fermi National Accelerator Laboratory, PO Box 500, Batavia IL 60510, United States. 2 “Gleb Wataghin” Institute of Physics, UNICAMP, Campinas-SP, 13083-859, Brazil. 3 CPqMAE - Research Center on Advanced Materials and Energy, Federal University of São Carlos (UFSCar), São Carlos, 13565-905, Brazil. 4 The Brazilian Center for Research in Physics (CBPF), Rio de Janeiro-RJ, 22290-180, Brazil. 5 School of Chemical Engineering, UNICAMP, Campinas-SP, 13083-859, Brazil. 6 São Carlos Institute of Chemistry, University of São Paulo, São Carlos-SP, 13566-590, Brazil. Email: rdoubnik@fnal.gov Abstract. The Long-Baseline Neutrino Facility (LBNF) located at the Sanford Underground Research Facility (SURF) in Lead, South Dakota, hosts the Deep Underground Neutrino Experiment (DUNE). This experiment employs cryostats containing nearly 70,000 metric tons of high-purity liquid argon (LAr). Ensuring LAr purity is critical for achieving the required electron lifetime, which directly impacts the experiment’s signal-to-noise ratio. The Horizontal Drift (HD) detector demands an electron lifetime exceeding 3 ms within its 3.5 m drift, equivalent to less than 100 parts-per-trillion (ppt) Oxygen contamination, while the Vertical Drift (VD) detector requires over 6 ms electron lifetime within its 6.0 m drift, corresponding to less than 50 ppt Oxygen contamination. To mitigate Nitrogen (N2) quenching of scintillation light, N2 contamination must remain below 1 ppm, as higher levels can result in up to a 20 % loss of light. The Brazil State University of Campinas (UNICAMP) significantly contributes to LBNF FDC through the development of argon purification and regeneration systems for HD and VD cryostats. UNICAMP designed and constructed the Purification Liquid Argon Cryostat (PuLArC), a small-scale test facility holding approximately 90 liters of LAr. Tests using PuLArC demonstrated that 1.2 kg of Li-FAU zeolite could reduce N₂ contamination from 20-50 ppm to 0.1-1.0 ppm within 1-2 hours. Tests at Fermilab’s Iceberg cryostat (2,596 liters) confirmed scalability, with 3 kg of Li-FAU reducing N₂ contamination from ~5 ppm to <1 ppm over 96 hours cycles without active circulation. This presentation will detail the research methods, test setups, and results, showcasing the potential of Li-FAU as an alternative to Molecular Sieve 4A for large-scale LAr systems. This advancement enhances DUNE's precision and demonstrates the impact of international collaboration on cryogenic research.

Doubnik, Roza [Fermilab]↗

Electron Beam Irradiation for Water Treatment of Per- and Polyfluoroalkyl Substances (PFAS)

Per- and polyfluoroalkyl substances (PFAS) are widely used but are now considered a water contamination risk. Fermi National Accelerator Laboratory’s IARC group has demonstrated that passing water through electron beam radiation can destroy PFAS. This project aims to develop a process to scale the system for bulk water treatment. The key is efficient radiation usage, ensuring that all water receives only the minimum dose. Software was developed for this purpose, consisting of a computational fluid dynamics model (CFD) in COMSOL, which calculates particle trajectories through the radiation area. A MATLAB script integrates the radiation dose of these particles, and statistical analysis is performed to evaluate the radiation utilization efficiency. These models are validated with a flow test where colored dye is injected and optically tracked. Radiation dose is measured by testing under an e-beam to measure the degradation of a PFAS analog.

Mueller, Scott [Northern Illinois U.]↗

Neutrino Oscillations at the NOvA Experiment

The NOvA experiment is a long-baseline neutrino oscillation experiments based at Fermi National Accelerator Laboratory in IL, USA. The experiment was designed to observe muon neutrino (muon anti-neutrino) disappearance and electron neutrino (electron anti-neutrino) appearance oscillations using a set of technological identical liquid scintillation detectors. The detectors are situated 14.6 milli-radians off-axis to the Fermilab's NuMI beam line that provides a beam of neutrinos (anti-neutrinos) to the experiment. The latest results from 3-flavor neutrino oscillation analysis from 10 years of NOvA data will be discussed in the talk.

Choudhary, Brajesh [Delhi U.]↗

Current Progress on the High-Field Cable Testing Facility at Fermilab

Fermi National Accelerator Laboratory (Fermilab) is constructing a new High Field Vertical Magnet Test Facility (HFVMTF) with capabilities comparable to the European facilities EDIPO and FRESCA2. The facility, located at Fermilab, will feature a background magnetic field of 15 T, generated by a magnet provided by Lawrence Berkeley National Laboratory (LBNL). The HFVMTF will support two U.S. national programs under the DOE Office of Science: the U.S. Fusion Energy Science (FES) program and the Magnet Development Program (MDP). It will enable the testing of HTS samples in high magnetic fields across a wide range of temperatures and facilitate the development of hybrid magnets combining LTS and HTS superconductors. This paper presents an overview of the current progress in constructing the facility, including updates on the test cryostat, power supplies, and systems for quench protection and monitoring.

Velev, G. [Fermilab]↗

New Measurement of Electron Neutrino Interactions on Argon in MicroBooNE

MicroBooNE, located at the Fermi National Accelerator Laboratory, is an 85-tonne liquid argon time-projection chamber designed to study neutrinos from the Booster Neutrino Beam and Neutrinos at the Main Injector (NuMI) beam. Understanding neutrino-nucleon interactions is essential for improving the accuracy of neutrino event generators, which are critical for modelling neutrino behaviour and interpreting data from oscillation experiments. The NuMI beam's high electron neutrino flux relative to its muon neutrino flux makes it particularly suited to probe these interactions. This poster presents new single-differential cross-section measurements of charged-current electron-neutrino interactions on argon with protons and no pions in the final state. These results use data from NuMI beam operations in both neutrino and antineutrino modes. Cross sections are reported as functions of key kinematic observables, including electron energy, total visible energy, and the opening angle between the electron and leading proton. Interaction rates as a function of proton multiplicity are also shown. These results are compared to theoretical predictions generated by widely used neutrino event generators.

Barnard, Abbey G. [Oxford U.] (ORCID:0000000161171↗

Fitness For Service Assessment of a Corroded Heat Exchanger

Within the Fermi National Accelerator complex, there exist various water systems that support accelerator operations. One of these systems is extremely vital to the operation of the machine; that is the cooling system. The cooling system consists of nine relatively large heat exchangers that take untreated pond water and use it to cool the process fluid that further cools machine components. Over the 30 years these heat exchangers have been in operation, they have undergone significant material loss on the channels. This material loss, due to various forms of corrosion such as galvanic and microbiologically influenced corrosion (MIC) and possibly others, has deteriorated more than 80% of the nominal wall thickness of some of the exchangers and placed them in a questionable state. ASME FFS-1 (API 579) has been applied to address the condition of the heat exchangers due to their noncompliance with the governing code, BPVC Sec. VIII Div. 1. The assessments encompassed ASME FFS-1 parts 4: General Metal Loss and 9: Crack Like Flaw using level 1, 2, and 3 analysis techniques based on inspection data obtained by API 510 inspections. Level 1 and 2 assessments were deemed unfit for the corroded regions due to their location relative to a major structural discontinuity (channel to tube-sheet joint), so a level 3 analysis was conducted according to ASME Sec. VIII Div. 2 (design by analysis) rules for pressure vessels. Supplemental information included pond water tests to determine an accurate future corrosion allowance due to lacking inspection history. A leak before break (LBB) route was chosen to evaluate the possibility of leaking prior to the onset of failure. The analysis of one heat exchanger shows that the possibility the channel will develop a pinhole leak over 2.5 more years of operation should not be overlooked, but burst was unlikely from operation. The use of fracture mechanics show, that if a through-wall crack were to develop, it would not propagate further than the channel geometry and cause a leak not greater than 35 GPM. Using ASME Section XI Code Case N-705-1, allowing us to operate with a leak until the next outage given certain operating conditions and developing a leak mitigation procedure, this heat exchanger is deemed fit-for-service.

Humenik, Alex [Fermilab]↗

Effects of Surface Treatments on the Outgassing of 3D-Printed 316L Stainless Steel.

Fermi National Accelerator Laboratory (Fermilab) is a world leader in designing and operating particle accelerators for nuclear and particle physics research. These accelerators rely on electric fields to propel particle beams, which are then directed and focused using magnetic fields. To ensure these beams travel without interference, they must move through an ultra-high vacuum environment, typically around 10⁻⁹ torr. Maintaining such a vacuum requires materials with exceptionally low outgassing rates. 316L stainless steel is a common material choice for vacuum systems due to its low outgassing rates, excellent corrosion resistance, non-magnetic properties, and high mechanical strength. When manufactured using traditional methods like machining, extrusion, and casting, the vacuum properties of 316L stainless steel are well understood. However, the behavior of 316L stainless steel produced through additive manufacturing, such as Direct Metal Laser Sintering (DMLS), is not as well documented. This study aims to determine the outgassing rate of 316L stainless steel fabricated using DMLS. The investigation focuses on measuring the outgassing rates of 1.5 2 vacuum reducers and evaluating the effects of surface preparation techniques, such as mechanical polishing and electropolishing, on the outgassing performance. Understanding the outgassing performance of 3D-printed 316L stainless steel could enable Fermilab engineers to adopt this fabrication method for producing complex parts designed for ultra-high vacuum environments. These advancements have the potential to benefit projects, such as the Long-Baseline Neutrino Facility (LBNF) and the Proton Improvement Plan-II (PIP-II), by improving design flexibility and fostering innovation in accelerator development.

Cloud, Jaiden [Central State University]↗

Analysis of scintillation light dependence on liquid Argon purity

Previous studies have investigated the correlation between impurity concentrations in Liquid Argon (LAr) and the temporal evolution of either the slow scintillation decay time or the light yield. These impurities typically consist of various molecular species. Electronegative contaminants directly affect electron drift and photon production, while other molecules, such as nitrogen (N_2),can influence LAr scintillation properties without necessarily affecting electron lifetime. Many current and future neutrino and dark-matter experiments use LAr detectors. This study aims to evaluate the measured electron lifetimes in relation to the timing characteristics of the scintillation light signal in the SBN ICARUS detector at Fermi National Accelerator Laboratory. The ICARUS experiment consists of two cryostats that have shown some discrepancies in the measured electron lifetime over the years. In particular, this study addresses the use of data collected under varying purity conditions in the two cryostats.

Saia, Clara [Catania Astrophys. Observ.]↗

PSEC5 Physical Verification

Ultra-Fast timing detectors, having a time resolution of 10pSec or less, are becoming increasingly important for many scientific disciplines, including High Energy Physics, Nuclear Physics, Medical Imaging and more. When developing ultra-fast detectors such as MCPs, LAPPDs, LGADs, SNSPDs, it is necessary to have access to a readout system that is low power, can support many channels and is cost effective. The PSEC5 chip was an application specific integrated circuit (ASIC) developed by the pioneering group of Prof. Henry Frisch at University of Chicago and micro electronic engineers at Fermi National Accelerator Laboratory. Three boards were designed, two to implement the readout system for an LAPPD and one to only characterize the PSEC1 chip. The main goal of the project shifted to setting up a testing environment to focus on the characterization of the chip. My student and I tested and characterized this ASIC using the third chip-on-board printed circuit board. Results show the successful fabrication and operation of some of the key building blocks and lead to the suggestions on modification for the second iteration of the chip.

Rico Aniles, H. D. [Unlisted]↗

Neutrino Oscillations at the NOvA Experiment

NOvA is a long-baseline neutrino oscillation experiment located at Fermi National Accelerator Laboratory (Fermilab) in Batavia, IL, USA. Its main goal is to extract neutrino oscillation parameters by examining the disappearance of $\nu_\mu \ (\bar{\nu}_\mu)$ and the appearance of $\nu_e \ (\bar{\nu}_e)$ at its far detector. The experiment uses the NuMI beamline at Fermilab, which delivers a high-purity neutrino and antineutrino beam. NOvA consists of two functionally similar, high-resolution liquid scintillator tracking calorimeters, both placed 14.6 milliradians off the beam axis. The near detector, positioned 100 m underground and 1 km from the beam's origin, captures unoscillated $\nu_\mu (\bar{\nu}_\mu)$ and instrinsic beam $\nu_e \ (\bar{\nu}_e)$ events. The far detector, located 810 km away from the beam source in Ash River, Minnesota, measures both unoscillated $\nu_\mu \ (\bar{\nu}_\mu)$ and those that have oscillated into $\nu_\mu \ (\bar{\nu}_\mu) \to \nu_e \ (\bar{\nu}_e)$. This poster will cover the latest results on three-flavor neutrino oscillation parameters, derived from an exposure of neutrino beam of $26.60 \times 10^{20}$ POT and anti-neutrino beam exposure of $12.50\times 10^{20}$ POT including an additional low energy $\nu_e$ sample.

Singh, Ishwar [Delhi U.]↗

Multi-Differential Charged Current 𝝂_𝝁− Argon Cross Section without Pions in the Final State Measurement in MicroBooNE , and Current Status of Simultaneous Cross Section Extraction with ANNIE

MicroBooNE, an 85-tonne liquid argon time projection chamber detector is on-axis to the Booster Neutrino Beam (BNB) at Fermi National Accelerator Laboratory. MicroBooNE is elucidating neutrino interactions with argon through cross-section measurements to refine interaction models and reduce uncertainties. In this poster, we present recent published single and double multi-differential charged current (CC) cross section with zero pions in the final state (CC-0 ) as a function of muon momentum ( ) and the cosine of the muon angle ( ). We present the details of the event selection and the extraction of 1D and 2D cross sections. We further report on the status of a simultaneous cross-section extraction conducted in conjunction with the ANNIE experiment, which employs a Gd-H O target and operates on the same BNB beamline. This joint measurement enables a precision test of nuclear A-dependence between oxygen and argon, with shared flux and cross-section model correlations leading to the cancellation of systematic uncertainties.

Nguyen, Christian Van [Rutgers U., Piscataway] (OR↗

Track Matching in the DUNE Near Detectors

The Deep Underground Neutrino Experiment (DUNE) is an international particle physics experiment looking answer some of the largest unanswered questions in neutrino physics. DUNE uses a high power neutrino beam produced at Fermi National Accelerator Laboratory (Fermilab), and consists of a near detector (ND) also located at Fermilab and a far detector (FD) 1300 km away at the Sanford Underground Research Facility (SURF) in South Dakota. In the first phase of the experiment, the ND complex will contain a modular liquid argon TPC (ND-LAr) and a solid scintillator-based muon spectrometer (TMS), in addition to a beam monitoring detector (SAND) and systems for moving ND-LAr and TMS away from the neutrino beam axis (PRISM). A prototype of ND-LAr, the 2x2 demonstrator, alongside a solid scintillator muon tagger provided by repurposed MINERvA planes, has been built and taken data at Fermilab. For analyses with the ND, connecting particle tracks (such as muons) that exit the liquid argon active volume into the solid scintillator muon detector can improve particle identification and energy reconstruction, and alleviate pileup due to the intense beam. To match tracks between detectors during reconstruction, we have explored using Graph Neural Networks (GNNs) to connect tracks segments between the liquid argon detector region and the solid scintillator detector planes. We have trained a GNN on reconstructed simulated data from the 2×2 demonstrator and repurposed MINERvA planes. We will evaluate its performance and then train a similar network on reconstructed ND-LAr and TMS simulations.

Xing, Daniel [U. Colorado, Boulder]↗

Real-Time Anomaly Detection for Beyond Standard Model Searches in ProtoDUNE Horizontal Drift

This paper summarizes work conducted throughout a SULI internship at Fermi National Accelerator Laboratory focused on building an unsupervised machine learning model for real-time anomaly detection in ProtoDUNE Horizontal Drift. Using simulated data, we trained an autoencoder model on a pure cosmic dataset, and evaluated it on both cosmic and neutrino events---making the model an anomaly detector. The goal was to make a model which matches or exceeds the current ADC Simple Window trigger algorithm so that our model can perform at the same rate but provide sensitivity to potential beyond-the-Standard-Model (BSM) signatures. In the end, we were able to construct a model which slightly exceeds the capabilities of the ADC Simple Window while remaining completely unsupervised, achieving $31.9 \pm 0.2$\% ($26.6 \pm 0.2$\%) $\nu$ efficiency at 5 Hz (2 Hz), a 3.6 (3.2) percentage point increase. Additionally, $17.5 \pm 0.3$\% ($18.3 \pm 0.3$\%) of the events that passed the autoencoder at 5 Hz (2 Hz) were missed by the current trigger algorithm. Future work will investigate alternative normalization methods, including quantile transformation, and evaluate the model on ProtoDUNE-HD detector-glitch data if that data becomes available.

Wilson, Cameron C. [Cincinnati U., RWC]↗

Captan+X Data Converter Integration

Fermi National Accelerator Laboratory's CAPTAN (Compact And Programmable daTa Acquisition Node) series provides a flexible hardware platform for data acquisition across a range of experiments and facilities. The latest iteration, CAPTAN+X, is built around a Kintex-7 FPGA supporting four FPGA Mezzanine Card (FMC) connections. As part of a broader laboratory effort to bring facility systems under a Model-Based Systems Engineering (MBSE) framework, CAPTAN+X is one of several systems slated to be incorporated into this modeling environment in the near term. A necessary step toward that goal is incorporating the platform's core functionality, which centers on integration with the LXD31K4 FMC, a data converter module combining dual AD9652 analog-to-digital converters and dual AD9142A digital-to-analog converters. Achieving compatibility required resolving pin-mapping conflicts between the LXD31K4's High Pin Count connector and the CAPTAN+X's available pin types, adapting a Board Support Project originally written for an UltraScale-class evaluation board to the Kintex-7 architecture, replacing incompatible primitives, restructuring clock distribution, and manually configuring chip initialization in place of an unsupported soft-processor-based approach. Functional verification of the ADC and DAC channels, followed by closed-loop testing combining both converters with real-time filtering, confirmed correct operation of the integrated system. These results establish a working hardware and firmware baseline for the CAPTAN+X platform, positioning it for future inclusion in the laboratory's growing MBSE modeling effort.

Espinoza, David [Illinois U., Urbana (main)]↗

Real-Time Anomaly Detection for Beyond Standard Model Searches in ProtoDUNE Horizontal Drift

This paper summarizes work conducted throughout a SULI internship at Fermi National Accelerator Laboratory focused on building an unsupervised machine learning model for real-time anomaly detection in ProtoDUNE Horizontal Drift. Using simulated data, we trained an autoencoder model on a pure cosmic dataset, and evaluated it on both cosmic and neutrino events---making the model an anomaly detector. The goal was to make a model which matches or exceeds the current ADC Simple Window trigger algorithm so that our model can perform at the same rate but provide sensitivity to potential beyond-the-Standard-Model (BSM) signatures. In the end, we were able to construct a model which slightly exceeds the capabilities of the ADC Simple Window while remaining completely unsupervised, achieving $31.9 \pm 0.2$\% ($26.6 \pm 0.2$\%) $\nu$ efficiency at 5 Hz (2 Hz), a 3.6 (3.2) percentage point increase. Additionally, $17.5 \pm 0.3$\% ($18.3 \pm 0.3$\%) of the events that passed the autoencoder at 5 Hz (2 Hz) were missed by the current trigger algorithm. Future work will investigate alternative normalization methods, including quantile transformation, and evaluate the model on ProtoDUNE-HD detector-glitch data if that data becomes available.

Wilson, Cameron C. [Cincinnati U., RWC]↗

An Iterative Machine Learning Framework for Event Classification and Monte Carlo Tuning in SpinQuest

The E1039/SpinQuest experiment at Fermi National Accelerator Laboratory uses a 120~GeV proton beam from the Main Injector incident on transversely polarized proton and deuteron targets, using $NH_3$ and $ND_3$, respectively. In addition to measuring the Sivers asymmetry in Drell--Yan $pp$ and $pd$ scattering from sea quarks, SpinQuest will study transverse-spin effects, particularly the transverse single-spin asymmetry (TSSA) in $J/\psi$ production. The angular distributions from the $J/\psi$ decay could play an important role in understanding the gluon contribution to the proton spin structure. However, before extracting these angular distributions, it is necessary to isolate signal events originating from the target from events produced by other sources and from the combinatorial background. To effectively and accurately classify the target events, it is important to ensure that the simulated events are properly tuned to the experimental physics channels. We have introduced an iterative technique to match simulated and experimental events and to classify the physics channels using deep neural networks and a generative model based on normalizing flows.

Hossain, Forhad [Virginia U. (main)] (ORCID:000000↗

Final Design and Current Status of the Mu2e Crystal Calorimeter

The Mu2e experiment at Fermi National Accelerator Laboratory will search for the CLFV neutrino-less conversion of a negative muon into an electron in the field of an aluminum nucleus. The Mu2e design has been studied to improve the single event sensitivity of four orders of magnitude with respect to the previous experiments and provide an indirect probe for New Physics energy scales up to thousands TeV. Mu2e is composed of a tracker, an electromagnetic calorimeter, and an external veto for cosmic rays. The calorimeter provides a powerful particle identification and an online trigger while operating in a harsh environment. We report on the status of the calorimeter components production, the quality assurance tests, and the tests performed with a reduced-scale prototype.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Beam dynamics corrections to the Run-1 measurement of the muon anomaly $a_{\mu}$ at Fermilab

The Fermi National Accelerator Laboratory (FNAL) Muon $g\!-\!2$ Experiment has measured the positive muon magnetic anomaly $a_{\mu} \equiv (g_{\mu}-2)/2$ with a precision of 0.46 parts per million, with data collected during its first physics run in 2018. The experimental result combined with the measurement from the former experiment at Brookhaven National Laboratory increases the tension with the Standard Model expectation to $4.2\sigma$, thus strengthening evidence for new physics.The magnetic anomaly is determined from the precision measurements of the muon spin precession frequency, relative to the muon momentum, and the average magnetic field seen by the beam. In an ideal case with muons orbiting in a horizontal plane with a uniform vertical magnetic field, the anomalous precession frequency $\omega_a$ is given by the difference between the spin ($s$) and cyclotron ($c$) frequencies, $\omega_a = \omega_s - \omega_c$. The observable $\omega_a$ is proportional to $a_{\mu}$.This proceeding presents the beam dynamics systematic corrections that are required to adjust the measured muon precession frequency $\omega^{m}_{a}$ to its true physical value $\omega_{a}$.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗