SU-C-18C-02: Specifcation of X-Ray Projection Angles Which Are Aligned with the Aortic Valve Plane From a Planar Image of a Valvuloplasty Balloon Inflated Across the Aortic Valve

Purpose: Transcatheter aortic valve replacement (TAVR) procedures provide a method to implant a prosthetic aortic valve via a minimallyinvasive, catheter-based procedure. TAVR procedures require use of interventional fluoroscopy c-arm projection angles which are aligned with the aortic valve plane to minimize prosthetic valve positioning error due to x-ray imaging parallax. The purpose of this work is to calculate the continuous range of interventional fluoroscopy c-arm projection angles which are aligned with the aortic valve plane from a single planar image of a valvuloplasty balloon inflated across the aortic valve. Methods: Computational methods to measure the 3D angular orientation of the aortic valve were developed. Required inputs include a planar x-ray image of a known valvuloplasty balloon inflated across the aortic valve and specifications of x-ray imaging geometry from the DICOM header of the image. A-priori knowledge of the species-specific typical range of aortic orientation is required to specify the sign of the angle of the long axis of the balloon with respect to the x-ray beam. The methods were validated ex-vivo and in a live pig. Results: Ex-vivo experiments demonstrated that the angular orientation of a stationary inflated valvuloplasty balloon can be measured with precision less than 1 degree. In-vivo pig experiments demonstrated that cardiac motion contributed to measurement variability, with precision less than 3 degrees. Error in specification of x-ray geometry directly influences measurement accuracy. Conclusion: This work demonstrates that the 3D angular orientation of the aortic valve can be calculated precisely from a planar image of a valvuloplasty balloon inflated across the aortic valve and known x-ray geometry. This method could be used to determine appropriate c-arm angular projections during TAVR procedures to minimize x-ray imaging parallax and thereby minimize prosthetic valve positioning errors.

60 APPLIED LIFE SCIENCES↗

SU-C-18C-06: Radiation Dose Reduction in Body Interventional Radiology: Clinical Results Utilizing a New Imaging Acquisition and Processing Platform

Purpose: To quantify the patient radiation dose reduction achieved during transarterial chemoembolization (TACE) procedures performed in a body interventional radiology suite equipped with the Philips Allura Clarity imaging acquisition and processing platform, compared to TACE procedures performed in the same suite equipped with the Philips Allura Xper platform. Methods: Total fluoroscopy time, cumulative dose area product, and cumulative air kerma were recorded for the first 25 TACE procedures performed to treat hepatocellular carcinoma (HCC) in a Philips body interventional radiology suite equipped with Philips Allura Clarity. The same data were collected for the prior 85 TACE procedures performed to treat HCC in the same suite equipped with Philips Allura Xper. Mean values from these cohorts were compared using two-tailed t tests. Results: Following installation of the Philips Allura Clarity platform, a 42.8% reduction in mean cumulative dose area product (3033.2 versus 1733.6 mGycm∧2, p < 0.0001) and a 31.2% reduction in mean cumulative air kerma (1445.4 versus 994.2 mGy, p < 0.001) was achieved compared to similar procedures performed in the same suite equipped with the Philips Allura Xper platform. Mean total fluoroscopy time was not significantly different between the two cohorts (1679.3 versus 1791.3 seconds, p = 0.41). Conclusion: This study demonstrates a significant patient radiation dose reduction during TACE procedures performed to treat HCC after a body interventional radiology suite was converted to the Philips Allura Clarity platform from the Philips Allura Xper platform. Future work will focus on evaluation of patient dose reduction in a larger cohort of patients across a broader range of procedures and in specific populations, including obese patients and pediatric patients, and comparison of image quality between the two platforms. Funding for this study was provided by Philips Healthcare, with 5% salary support provided to authors K. Pallav Kolli and Robert G. Gould for time devoted to the study. Data acquisition and analysis was performed by the authors independent of the funding source.

60 APPLIED LIFE SCIENCES↗

SU-E-I-37: Low-Dose Real-Time Region-Of-Interest X-Ray Fluoroscopic Imaging with a GPU-Accelerated Spatially Different Bilateral Filtering

Purpose: The purpose of our study is to reduce imaging radiation dose while maintaining image quality of region of interest (ROI) in X-ray fluoroscopy. A low-dose real-time ROI fluoroscopic imaging technique which includes graphics-processing-unit- (GPU-) accelerated image processing for brightness compensation and noise filtering was developed in this study. Methods: In our ROI fluoroscopic imaging, a copper filter is placed in front of the X-ray tube. The filter contains a round aperture to reduce radiation dose to outside of the aperture. To equalize the brightness difference between inner and outer ROI regions, brightness compensation was performed by use of a simple weighting method that applies selectively to the inner ROI, the outer ROI, and the boundary zone. A bilateral filtering was applied to the images to reduce relatively high noise in the outer ROI images. To speed up the calculation of our technique for real-time application, the GPU-acceleration was applied to the image processing algorithm. We performed a dosimetric measurement using an ion-chamber dosimeter to evaluate the amount of radiation dose reduction. The reduction of calculation time compared to a CPU-only computation was also measured, and the assessment of image quality in terms of image noise and spatial resolution was conducted. Results: More than 80% of dose was reduced by use of the ROI filter. The reduction rate depended on the thickness of the filter and the size of ROI aperture. The image noise outside the ROI was remarkably reduced by the bilateral filtering technique. The computation time for processing each frame image was reduced from 3.43 seconds with single CPU to 9.85 milliseconds with GPU-acceleration. Conclusion: The proposed technique for X-ray fluoroscopy can substantially reduce imaging radiation dose to the patient while maintaining image quality particularly in the ROI region in real-time.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-I-86: Evaluation of the New RaySafe Unfors X2 Dosimetry System

Purpose: To evaluate the new RaySafe Unfors X2 (X2) dosimetry system and compare it to the operation of the RaySafe Unfors Xi (Xi) and Radcal Accugold (RCAG) dosimetry systems. The comparison was done for the radiographic/fluoroscopic detectors, mammography detectors and the CT ionization chambers. Methods: This study used several R/F rooms, GE AMX4 portable x-ray unit, Siemens Biograph 16 slice CT scanner and a Hologic Dimensions mammography unit to evaluate the dosimetry systems. The three X2 detectors were compared to similar detectors of the older Xi and RCAG detectors under clinical conditions used for diagnostic medical physics testing. Measurements of kVp, HVL and exposure were made under identical conditions. Results: For radiography and fluoroscopy the three systems agreed to within +2 kVp in the 60 to 140 kVp range, HVL measurements agreed to within +2 mm Al and the exposures agreed to within +5%. The RCAG 6 cc ionization chamber measured at least 3% higher than the diode systems. The X2 R/F detector appeared to be transparent to the fluoroscopy AEC system. For exposures made using both the CT ACR dose phantoms, the X2 agreed to within +3% of the other two systems. For mammography measurements, the three systems agreed to within +0.4kVp (25-49 kVp range), HVL measurements agreed to within +0.05 mm Al and the exposures agreed to within +1% of the ionization chamber. Conclusion: The X2 system is a new version of the older Xi system. The system is faster, more robust, very easy to use, has a larger dynamic range, produced less errors and stores 1000 exposures. The measurements showed that the system performs well in the clinical environment and the X2 is within + 5% agreement of the other two calibrated systems.

60 APPLIED LIFE SCIENCES↗

SU-E-J-176: Results of Images Acquired with Backscattered MV Radiation Using a Pinhole Collimator

Purpose: To ascertain the feasibility of acquiring real time images of small lung tumors from scattered photons while undergoing radiation treatment.There are several methodologies currently used to track tumor location such as MV-cine acquisition and kV fluoroscopy. However, MVcine offers no information parallel to the beam axis while kV fluoroscopy offers little potential for soft tissue discernability while also increasing the patient dose. This study investigates the feasibility of observing an actual simulated tumor while exploring techniques that may improve image quality. Methods: A prototype imager consisting of a gamma camera pinhole collimator and a computed radiography (CR) plate were used in conjunction with a Varian TrueBeam linac. One study consisted of a 2.5 cm diameter solid water cylinder representing a solid tumor imbedded within a lung equivalent material slab. The cylinder with the lung slab was sandwiched between 1 cm lung equivalent slabs and these were sandwiched between 2 slabs of solid water. The top water slab was 1 cm thick. The other imaging study consisted of three different density plugs, 0.46, 1.09, and 1.82 g/cm3 placed on the accelerator couch. The gantry was orientated 70° relative to the CR plate. The slabs and plugs were irradiated with 2000 MU and 500 MU respectively using the 6FFF mode. Results: The solid water plug was visually discernible in the slab phantom. The ratio of the signal coming from the higher density plugs (placed on the treatment couch) to that between the plugs increased from 1.02 to about 3.0 after subtracting the background image acquired with no plugs present. Conclusion: Preliminary results indicate that a lung tumor could be visualized with scattered radiation during treatment. Improvements in discerning an object can be enhanced by filtering out the head leakage and background scattered radiation not emanating from the imaged object.

60 APPLIED LIFE SCIENCES↗

WE-A-17A-11: Implanted Brachytherapy Seed Movement Due to Transrectal Ultrasound Probe-Induced Prostate Deformation

Purpose: To characterize the movement of implanted brachytherapy seeds due to transrectal ultrasound probe-induced prostate deformation and to estimate the effects on prostate dosimetry. Methods: Implanted probe-in and probe-removed seed distributions were reconstructed for 10 patients using C-arm fluoroscopy imaging. The prostate was delineated on ultrasound and registered to the fluoroscopy seeds using a visible subset of seeds and residual needle tracks. A linear tensor and shearing model correlated the seed movement with position. The seed movement model was used to infer the underlying prostate deformation and to simulate the prostate contour without probe compression. Changes in prostate and surrogate urethra dosimetry were calculated. Results: Seed movement patterns reflecting elastic decompression, lateral shearing, and rectal bending were observed. Elastic decompression was characterized by anterior-posterior expansion and superior-inferior and lateral contractions. For lateral shearing, anterior movement up to 6 mm was observed for extraprostatic seeds in the lateral peripheral region. The average intra-prostatic seed movement was 1.3 mm, and the residual after linear modeling was 0.6 mm. Prostate D90 increased by 4 Gy on average (8 Gy max) and was correlated with elastic decompression. For selected patients, lateral shearing resulted in differential change in D90 of 7 Gy between anterior and posterior quadrants, and increase in whole prostate D90 of 4 Gy. Urethra D10 increased by 4 Gy. Conclusion: Seed movement upon probe removal was characterized. The proposed model captured the linear correlation between seed movement and position. Whole prostate dose coverage increased slightly, due to the small but systematic seed movement associated with elastic decompression. Lateral shearing movement increased dose coverage in the anterior-lateral region, at the expense of the posterior-lateral region. The effect on whole prostate D90 was smaller due to the subset of peripheral seeds involved, but lateral shearing movement can have greater consequences for local dose coverage.

60 APPLIED LIFE SCIENCES↗

Poster — Thur Eve — 77: Implanted Brachythearpy Seed Movement due to Transrectal Ultrasound Probe-Induced Prostate Deformation

The study investigated the movement of implanted brachytherapy seeds upon transrectal US probe removal, providing insight into the underlying prostate deformation and an estimate of the impact on prostate dosimetry. Implanted seed distributions, one obtained with the prostate under probe compression and another with the probe removed, were reconstructed using C-arm fluoroscopy imaging. The prostate, delineated on ultrasound images, was registered to the fluoroscopy images using seeds and needle tracks identified on ultrasound. A deformation tensor and shearing model was developed to correlate probe-induced seed movement with position. Changes in prostate TG-43 dosimetry were calculated. The model was used to infer the underlying prostate deformation and to estimate the location of the prostate surface in the absence of probe compression. Seed movement patterns upon probe removal reflected elastic decompression, lateral shearing, and rectal bending. Elastic decompression was characterized by expansion in the anterior-posterior direction and contraction in the superior-inferior and lateral directions. Lateral shearing resulted in large anterior movement for extra-prostatic seeds in the lateral peripheral region. Whole prostate D90 increased up to 8 Gy, mainly due to the small but systematic seed movement associated with elastic decompression. For selected patients, lateral shearing movement increased prostate D90 by 4 Gy, due to increased dose coverage in the anterior-lateral region at the expense of the posterior-lateral region. The effect of shearing movement on whole prostate D90 was small compared to elastic decompression due to the subset of peripheral seeds involved, but is expected to have greater consequences for local dose coverage.

60 APPLIED LIFE SCIENCES↗

Verification and compensation of respiratory motion using an ultrasound imaging system

Purpose: The purpose of this study was to determine if it is feasible to use ultrasound imaging as an aid for moving the treatment couch during diagnosis and treatment procedures associated with radiation therapy, in order to offset organ displacement caused by respiratory motion. A noninvasive ultrasound system was used to replace the C-arm device during diagnosis and treatment with the aims of reducing the x-ray radiation dose on the human body while simultaneously being able to monitor organ displacements. Methods: This study used a proposed respiratory compensating system combined with an ultrasound imaging system to monitor the compensation effect of respiratory motion. The accuracy of the compensation effect was verified by fluoroscopy, which means that fluoroscopy could be replaced so as to reduce unnecessary radiation dose on patients. A respiratory simulation system was used to simulate the respiratory motion of the human abdomen and a strain gauge (respiratory signal acquisition device) was used to capture the simulated respiratory signals. The target displacements could be detected by an ultrasound probe and used as a reference for adjusting the gain value of the respiratory signal used by the respiratory compensating system. This ensured that the amplitude of the respiratory compensation signal was a faithful representation of the target displacement. Results: The results show that performing respiratory compensation with the assistance of the ultrasound images reduced the compensation error of the respiratory compensating system to 0.81–2.92 mm, both for sine-wave input signals with amplitudes of 5, 10, and 15 mm, and human respiratory signals; this represented compensation of the respiratory motion by up to 92.48%. In addition, the respiratory signals of 10 patients were captured in clinical trials, while their diaphragm displacements were observed simultaneously using ultrasound. Using the respiratory compensating system to offset, the diaphragm displacement resulted in compensation rates of 60%–84.4%. Conclusions: This study has shown that a respiratory compensating system combined with noninvasive ultrasound can provide real-time compensation of the respiratory motion of patients.

60 APPLIED LIFE SCIENCES↗

SU-E-J-194: Continuous Patient Surface Monitoring and Motion Analysis During Lung SBRT

Purpose: Continuous monitoring of the SBRT lung patient motion during delivery is critical for ensuring adequate target volume margins in stereotactic body radiotherapy (SBRT). This work assesses the deviation of the patient surface motion using a real-time surface tracking system throughout treatment delivery. Methods: Our SBRT protocol employs abdominal compression to reduce the diaphragm movement to within 1 cm, and this is confirmed daily with fluoroscopy. Most patients are prescribed 3–5 fractions, and on treatment day a repeat motion analysis with fluoroscopy is performed, followed by a kV CBCT is aligned with the original planning CT image for 3D setup confirmation. During this entire process a patient surface data restricted to whole chest or the sternum at the middle of the breathing cycle was captured using AlignRT optical surface tracking system and defined as a reference surface. For 10 patients, the deviation of the patient position from the reference surface was recorded during the SBRT delivery in the anterior-posterior (AP) direction at 3–6 measurements per second. Results: On average, the patient position deviated from the reference surface more than 4 mm, 3 mm and 2 mm in the AP direction for 0.95%, 3.7% and 11.1% of the total treatment time, respectively. Only one of the 10 patients showed that the maximum deviation of the patient surface during the SBRT delivery was greater than 1 cm. The average deviation of the patient surface from the reference surface during the SBRT delivery was not greater than 1.6 mm for any patient. Conclusion: This investigation indicates that AP motion can be significant even though the frequency is low. Continuous monitoring during SBRT has demonstrated value in monitoring patient motion ensuring that margins selected for SBRT are appropriate, and the use of non-ionizing and high-frequency imaging can provide useful indicators of motion during treatment.

60 APPLIED LIFE SCIENCES↗

WE-AB-303-03: A Scheme for Real-Time, Marker-Less and Low-Dose Tumor Tracking Using Scattering Imaging: Monte Carlo Simulation Study

Purpose: In-treatment tumor localization is critical for the management of tumor motion in lung cancer radiotherapy. Conventional tumor-tracking methods using a kV or MV x-ray projection has limited contrast. To facilitate real-time, marker-less and low-dose in-treatment image tumor tracking, we propose a novel scheme using Compton scatter imaging. This study reports Monte Carlo (MC) simulations on this scheme for the purpose of proof-of-principle. Methods: A slit x-ray beam along the patient superior-inferior (SI) direction is directed to the patient, intersecting the patient lung at a 2D plane containing majority part of the tumor motion trajectory. X-ray photons are scattered due to Compton effect from this plane, which are spatially collimated by, e.g., a pinhole, on one side of the plane and then captured by a detector behind it. The captured image, after correcting for x-ray attenuation and scatter angle variation, reflects the electron density, which allows visualization of the instantaneous anatomy on this plane. We performed MC studies on a phantom and a patient case for the initial test of this proposed method. Results: In the phantom case, the contrast-resolution calculated using tumor/lung as foreground/background for kV fluoroscopy, cone-beam CT, and scattering image were 0.0625, 0.6993, and 0.5290, respectively. In the patient case, tumor motion can be clearly observed in the scatter images. Compared to fluoroscopy, scattering imaging also significantly reduced imaging dose because of its narrower beam design. Conclusion: MC simulation studies demonstrated the potential of the proposed scheme in terms of capturing the instantaneous anatomy of a patient on a 2D plane. Clear visualization of the tumor will probably facilitate ‘marker-less’ and ‘real-time’ tumor tracking with low imaging dose. NIH (1R01CA154747-01, 1R21CA178787-01A1 and 1R21EB017978-01A1)

60 APPLIED LIFE SCIENCES↗

WE-EF-303-05: Development and Commissioning of Real-Time Imaging Function for Respiratory-Gated Spot-Scanning Proton Beam Therapy

Purpose: To realize real-time-image gated proton beam therapy (RGPT) for treating mobile tumors. Methods: The rotating gantry of spot scanning proton beam therapy has been designed to equip two x-ray fluoroscopy devices that enable real-time imaging of the internal fiducial markers during respiration. Three-dimensional position of the fiducial marker located near the tumor can be calculated from the fluoroscopic images obtained from orthogonal directions and therapeutic beam is gated only when the fiducial marker is within the predefined gating window. Image acquisition rate can be selected from discrete value ranging from 0.1 Hz to 30 Hz. In order to confirm the effectiveness of RGPT and apply it clinically, clinical commissioning was conducted. Commissioning tests were categorized to main three parts including geometric accuracy, temporal accuracy and dosimetric evaluation. Results: Developed real-time imaging function has been installed and its basic performances have been confirmed. In the evaluation of geometric accuracy, coincidence of three-dimensional treatment room coordinate system and imaging coordinate system was confirmed to be less than 1 mm. Fiducial markers (gold sphere and coil) were able to be tracked in simulated clinical condition using an anthropomorphic chest phantom. In the evaluation of temporal accuracy, latency from image acquisition to gate on/off signal was about 60 msec in typical case. In dosimetric evaluation, treatment beam characteristics including beam irradiation position and dose output were stable in gated irradiation. Homogeneity indices to the mobile target were 0.99 (static), 0.89 (w/o gating, motion is parallel to direction of scan), 0.75 (w/o gating, perpendicular), 0.98 (w/ gating, parallel) and 0.93 (w/ gating, perpendicular). Dose homogeneity to the mobile target can be maintained in RGPT. Conclusion: Real-time imaging function utilizing x-ray fluoroscopy has been developed and commissioned successfully in order to realize RGPT. Funding Support: This research was partially supported by Japan Society for the Promotion of Science (JSPS) through the FIRST Program. Conflict of Interest: Prof. Shirato has research fund from Hitachi Ltd, Mitsubishi Heavy Industries Ltd and Shimadzu Corporation.

60 APPLIED LIFE SCIENCES↗

WE-G-204-03: Photon-Counting Hexagonal Pixel Array CdTe Detector: Optimal Resampling to Square Pixels

Purpose: Detectors with hexagonal pixels require resampling to square pixels for distortion-free display of acquired images. In this work, the presampling modulation transfer function (MTF) of a hexagonal pixel array photon-counting CdTe detector for region-of-interest fluoroscopy was measured and the optimal square pixel size for resampling was determined. Methods: A 0.65mm thick CdTe Schottky sensor capable of concurrently acquiring up to 3 energy-windowed images was operated in a single energy-window mode to include ≥10 KeV photons. The detector had hexagonal pixels with apothem of 30 microns resulting in pixel spacing of 60 and 51.96 microns along the two orthogonal directions. Images of a tungsten edge test device acquired under IEC RQA5 conditions were double Hough transformed to identify the edge and numerically differentiated. The presampling MTF was determined from the finely sampled line spread function that accounted for the hexagonal sampling. The optimal square pixel size was determined in two ways; the square pixel size for which the aperture function evaluated at the Nyquist frequencies along the two orthogonal directions matched that from the hexagonal pixel aperture functions, and the square pixel size for which the mean absolute difference between the square and hexagonal aperture functions was minimized over all frequencies up to the Nyquist limit. Results: Evaluation of the aperture functions over the entire frequency range resulted in square pixel size of 53 microns with less than 2% difference from the hexagonal pixel. Evaluation of the aperture functions at Nyquist frequencies alone resulted in 54 microns square pixels. For the photon-counting CdTe detector and after resampling to 53 microns square pixels using quadratic interpolation, the presampling MTF at Nyquist frequency of 9.434 cycles/mm along the two directions were 0.501 and 0.507. Conclusion: Hexagonal pixel array photon-counting CdTe detector after resampling to square pixels provides high-resolution imaging suitable for fluoroscopy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

WE-G-204-04: Focal Spot Deblurring For High Resolution Amorphous Selenium (aSe) Complementary Metal Oxide Semiconductor (CMOS) X-Ray Detector

Purpose: CMOS-based aSe detectors compared to CsI-TFT-based flat panels have the advantages of higher spatial sampling due to smaller pixel size and decreased blurring characteristic of direct rather than indirect detection. For systems with such detectors, the limiting factor degrading image resolution then becomes the focal-spot geometric unsharpness. This effect can seriously limit the use of such detectors in areas such as cone beam computed tomography, clinical fluoroscopy and angiography. In this work a technique to remove the effect of focal-spot blur is presented for a simulated aSe detector. Method: To simulate images from an aSe detector affected with focal-spot blur, first a set of high-resolution images of a stent (FRED from Microvention, Inc.) were acquired using a 75µm pixel size Dexela-Perkin-Elmer detector and averaged to reduce quantum noise. Then the averaged image was blurred with a known Gaussian blur at two different magnifications to simulate an idealized focal spot. The blurred images were then deconvolved with a set of different Gaussian blurs to remove the effect of focal-spot blurring using a threshold-based, inverse-filtering method. Results: The blur was removed by deconvolving the images using a set of Gaussian functions for both magnifications. Selecting the correct function resulted in an image close to the original; however, selection of too wide a function would cause severe artifacts. Conclusion: Experimentally, focal-spot blur at different magnifications can be measured using a pin hole with a high resolution detector. This spread function can be used to deblur the input images that are acquired at corresponding magnifications to correct for the focal spot blur. For CBCT applications, the magnification of specific objects can be obtained using initial reconstructions then corrected for focal-spot blurring to improve resolution. Similarly, if object magnification can be determined such correction may be applied in fluoroscopy and angiography.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Accuracy and calibration of integrated radiation output indicators in diagnostic radiology: A report of the AAPM Imaging Physics Committee Task Group 190

Due to the proliferation of disciplines employing fluoroscopy as their primary imaging tool and the prolonged extensive use of fluoroscopy in interventional and cardiovascular angiography procedures, “dose-area-product” (DAP) meters were installed to monitor and record the radiation dose delivered to patients. In some cases, the radiation dose or the output value is calculated, rather than measured, using the pertinent radiological parameters and geometrical information. The AAPM Task Group 190 (TG-190) was established to evaluate the accuracy of the DAP meter in 2008. Since then, the term “DAP-meter” has been revised to air kerma-area product (KAP) meter. The charge of TG 190 (Accuracy and Calibration of Integrated Radiation Output Indicators in Diagnostic Radiology) has also been realigned to investigate the “Accuracy and Calibration of Integrated Radiation Output Indicators” which is reflected in the title of the task group, to include situations where the KAP may be acquired with or without the presence of a physical “meter.” To accomplish this goal, validation test protocols were developed to compare the displayed radiation output value to an external measurement. These test protocols were applied to a number of clinical systems to collect information on the accuracy of dose display values in the field.

60 APPLIED LIFE SCIENCES↗

SU-F-P-42: “To Navigate, Or Not to Navigate: HDR BT in Recurrent Spine Lesions”

Purpose: We compare the accuracy of HDR catheter placement for paraspinal lesions using O-arm CBCT imaging combined with StealthStation navigation and traditional fluoroscopically guided catheter placement. Methods: CT and MRI scans were acquired pre-treatment to outline the lesions and design treatment plans (pre-plans) to meet dosimetric constrains. The pre-planned catheter trajectories were transferred into the StealthStation Navigation system prior to the surgery. The StealthStation is an infra red (IR) optical navigation system used for guidance of surgical instruments. An intraoperative CBCT scan (O-arm) was acquired with reference IR optical fiducials anchored onto the patient and registered with the preplan image study to guide surgical instruments in relation to the patients’ anatomy and to place the brachytherapy catheters along the pre-planned trajectories. The final treatment plan was generated based on a 2nd intraoperative CBCT scan reflecting achieved implant geometry. The 2nd CBCT was later registered with the initial CT scan to compare the preplanned dwell positions with actual dwell positions (catheter placements). Similar workflow was used in placement of 8 catheters (1 patient) without navigation, but under fluoroscopy guidance in an interventional radiology suite. Results: A total of 18 catheters (3 patients) were placed using navigation assisted surgery. Average displacement of 0.66 cm (STD=0.37cm) was observed between the pre-plan source positions and actual source positions in the 3 dimensional space. This translates into an average 0.38 cm positioning error in one direction including registration errors, digitization errors, and the surgeons ability to follow the planned trajectory. In comparison, average displacement of non-navigated catheters was 0.50 cm (STD=0.22cm). Conclusion: Spinal lesion HDR brachytherapy planning is a difficult task. Catheter placement has a direct impact on target coverage and dose to critical structures. While limited to a handful of patients, our experience shows navigation and fluoroscopy guided placement yield similar results.

60 APPLIED LIFE SCIENCES↗

SU-F-I-11: Software Development for 4D-CBCT Research of Real-Time-Image Gated Spot Scanning Proton Therapy

Purpose: To acquire correct information for inside the body in patient positioning of Real-time-image Gated spot scanning Proton Therapy (RGPT), utilization of tomographic image at exhale phase of patient respiration obtained from 4-dimensional Cone beam CT (4D-CBCT) has been desired. We developed software named “Image Analysis Platform” for 4D-CBCT researches which has technique to segment projection-images based on 3D marker position in the body. The 3D marker position can be obtained by using two axes CBCT system at Hokkaido University Hospital Proton Therapy Center. Performance verification of the software was implemented. Methods: The software calculates 3D marker position retrospectively by using matching positions on pair projection-images obtained by two axes fluoroscopy mode of CBCT system. Log data of 3D marker tracking are outputted after the tracking. By linking the Log data and gantry-angle file of projection-image, all projection-images are equally segmented to spatial five-phases according to marker 3D position of SI direction and saved to specified phase folder. Segmented projection-images are used for CBCT reconstruction of each phase. As performance verification of the software, test of segmented projection-images was implemented for sample CT phantom (Catphan) image acquired by two axes fluoroscopy mode of CBCT. Dummy marker was added on the images. Motion of the marker was modeled to move in 3D space. Motion type of marker is sin4 wave function has amplitude 10.0 mm/5.0 mm/0 mm, cycle 4 s/4 s/0 s for SI/AP/RL direction. Results: The marker was tracked within 0.58 mm accuracy in 3D for all images, and it was confirmed that all projection-images were segmented and saved to each phase folder correctly. Conclusion: We developed software for 4D-CBCT research which can segment projection-image based on 3D marker position. It will be helpful to create high quality of 4D-CBCT reconstruction image for RGPT.

60 APPLIED LIFE SCIENCES↗

TU-AB-BRA-06: BEST IN PHYSICS (JOINT IMAGING-THERAPY): An MRI Compatible Externally and Internally Deformable Lung Motion Phantom for Multi-Modality IGRT

Purpose: MRI has become an attractive tool for tumor motion management. Current MR-compatible phantoms are only capable of reproducing translational motion. This study describes the construction and validation of a more realistic, MRI-compatible lung phantom that is deformable internally as well as externally. We demonstrate a radiotherapy application of this phantom by validating the geometric accuracy of the open-source deformable image registration software NiftyReg (UCL, UK). Methods: The outer shell of a commercially-available dynamic breathing torso phantom was filled with natural latex foam with eleven water tubes. A rigid foam cut-out served as the diaphragm. A high-precision programmable, in-house, MRI-compatible motion platform was used to drive the diaphragm. The phantom was imaged on a 3T scanner (Philips, Ingenia). Twenty seven tumor traces previously recorded from lung cancer patients were programmed into the phantom and 2D+t image sequences were acquired using a sparse-sampling sequence k-t BLAST (accn=3, resolution=0.66×0.66×5mm3; acquisition-time=110ms/slice). The geometric fidelity of the MRI-derived trajectories was validated against those obtained via fluoroscopy using the on board kV imager on a Truebeam linac. NiftyReg was used to perform frame by frame deformable image registration. The location of each marker predicted by using NiftyReg was compared with the values calculated by intensity-based segmentation on each frame. Results: In all cases, MR trajectories were within 1 mm of corresponding fluoroscopy trajectories. RMSE between centroid positions obtained from segmentation with those obtained by NiftyReg varies from 0.1 to 0.21 mm in the SI direction and 0.08 to 0.13 mm in the LR direction showing the high accuracy of deformable registration. Conclusion: We have successfully designed and demonstrated a phantom that can accurately reproduce deformable motion under a variety of imaging modalities including MRI, CT and x-ray fluodoscopy, making it an invaluable research tool for validating novel motion management strategies. This work was partially supported through research funding from National Institutes of Health (R01CA169102).

60 APPLIED LIFE SCIENCES↗

{sup 90}Y Resin Microspheres Radioembolization for Colon Cancer Liver Metastases Using Full-Strength Contrast Material

ObjectivesTo assess safety and efficacy of {sup 90}Y resin microspheres administration using undiluted non-ionic contrast material (UDCM) {100% Omnipaque-300 (Iohexol)} in both the “B” and “D” lines.Materials and methodsWe reviewed all colorectal cancer liver metastases patients treated with {sup 90}Y resin microspheres radioembolization (RAE) from 2009 to 2017. As of April 2013, two experienced operators started using UDCM (study group) instead of standard sandwich infusion (control group). Occurrence of myelosuppression (leukopenia, neutropenia, erythrocytopenia or/and thrombocytopenia), stasis, nontarget delivery (NTD), median fluoroscopy radiation dose (FRD), median infusion time (IT), liver progression-free (LPFS) and overall survivals (OS) was evaluated. Complications within 6 months post-RAE were reported according to CTCAE v3.0 criteria.ResultsStudy and control groups comprised 23(28%) and 58(72%) patients, respectively. Median follow-up was 9.1 months. There was no statistically significant difference in myelosuppression incidence within 6 months post-RAE between groups. Median FRD and IT for study and control groups were 44.6 vs. 97.35 Gy/cm{sup 2} (p = 0.048) and 31 vs. 39 min (p = 0.006), respectively. A 38% lower stasis incidence in study group was not significant (p = 0.34). NTD occurred in 1/27(4%) study vs. 5/73(7%) control group procedures (p = 1). Grade 1–2 and grade 3–4 toxicities between study and control group patients were 36%(8/22) vs. 45%(26/58), p = 0.61 and 9%(2/22) vs. 16%(9/58), p = 0.72, respectively. There was no difference in LPFS and OS between groups.ConclusionAdministration of {sup 90}Y resin microspheres using UDCM in both lines is safe and effective, resulting in lower fluoroscopy radiation dose and shorter infusion time, without evidence of myelosuppression or increased stasis incidence.

62 RADIOLOGY AND NUCLEAR MEDICINE↗