Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FLUID MEASUREMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Experimental Investigation of Hydraulic Fracturing and Stress Sensitivity of Fracture Permeability Under Changing Polyaxial Stress Conditions

Understanding and predicting fracture propagation and subsequent fluid flow characteristics is critical to geoenergy technologies that engineer and/or utilize favorable geological conditions to store or extract fluids from the subsurface. Fracture permeability decreases nonlinearly with increasing normal stress, but the relationship between shear displacement and fracture permeability is less well understood. We utilize the new Geo–Reservoir Experimental Analogue Technology (GREAT cell), which can apply polyaxial stress states and realistic reservoir temperatures and pressures to cylindrical samples and has the unique capability to alter both the magnitude and orientation of the radial stress field by increments of 11.25° during an experiment. We load synthetic analogue materials and real rock samples to stress conditions representative of 500–1,000 m depth, investigate the hydraulic stimulation process, and then conduct flow experiments while changing the fluid pressure and the orientation of the intermediate and minimum principal stresses. High–resolution circumferential strain measurements combined with fluid pressure data indicate fracture propagation can be both stable (no fluid pressure drop) and unstable (fluid pressure drop). The induced fractures exhibit both opening and shear displacements during their creation and/or during fluid flow with changing radial stress states. Flow tests during radial stress field rotation reveal that fracture normal effective stress has first–order control on fracture permeability but increasing fracture offset can lead to elevated permeabilities at maximum shear stress. Here, the results have implications for our conceptual understanding of fracture propagation as well as fluid flow and deformation around fractures.

58 GEOSCIENCES↗

Quantifying error of lidar and sodar Doppler beam swinging measurements of wind turbine wakes using computational fluid dynamics

Wind-profiling lidars are now regularly used in boundary-layer meteorology and in applications such as wind energy and air quality. Lidar wind profilers exploit the Doppler shift of laser light backscattered from particulates carried by the wind to measure a line-of-sight (LOS) velocity. The Doppler beam swinging (DBS) technique, used by many commercial systems, considers measurements of this LOS velocity in multiple radial directions in order to estimate horizontal and vertical winds. The method relies on the assumption of homogeneous flow across the region sampled by the beams. Using such a system in inhomogeneous flow, such as wind turbine wakes or complex terrain, will result in errors. To quantify the errors expected from such violation of the assumption of horizontal homogeneity, we simulate inhomogeneous flow in the atmospheric boundary layer, notably stably stratified flow past a wind turbine, with a mean wind speed of 6.5 m s -1 at the turbine hub-height of 80 m. This slightly stable case results in 15° of wind direction change across the turbine rotor disk. The resulting flow field is sampled in the same fashion that a lidar samples the atmosphere with the DBS approach, including the lidar range weighting function, enabling quantification of the error in the DBS observations. The observations from the instruments located upwind have small errors, which are ameliorated with time averaging. However, the downwind observations, particularly within the first two rotor diameters downwind from the wind turbine, suffer from errors due to the heterogeneity of the wind turbine wake. Errors in the stream-wise component of the flow approach 30% of the hub-height inflow wind speed close to the rotor disk. Errors in the cross-stream and vertical velocity components are also significant: cross-stream component errors are on the order of 15% of the hub-height inflow wind speed (1.0 m s −1 ) and errors in the vertical velocity measurement exceed the actual vertical velocity. By three rotor diameters downwind, DBS-based assessments of wake wind speed deficits based on the stream-wise velocity can be relied on even within the near wake within 1.0 s -1 (or 15% of the hub-height inflow wind speed), and the cross-stream velocity error is reduced to 8% while vertical velocity estimates are compromised. Furthermore, measurements of inhomogeneous flow such as wind turbine wakes are susceptible to these errors, and interpretations of field observations should account for this uncertainty.

17 WIND ENERGY↗

Axisymmetric flows from fluid injection into a confined porous medium

In this work, we study the axisymmetric flows generated from fluid injection into a horizontal confined porous medium that is originally saturated with another fluid of different density and viscosity. Neglecting the effects of surface tension and fluid mixing, we use the lubrication approximation to obtain a nonlinear advection-diffusion equation that describes the time evolution of the sharp fluid-fluid interface. The flow behaviors are controlled by two dimensionless groups: M , the viscosity ratio of displaced fluid relative to injected fluid, and Γ , which measures the relative importance of buoyancy and fluid injection. For this axisymmetric geometry, the similarity solution involving R 2 /T (where R is the dimensionless radial coordinate and T is the dimensionless time) is an exact solution to the nonlinear governing equation for all times. Four analytical expressions are identified as asymptotic approximations (two of which are new solutions): (i) injection-driven flow with the injected fluid being more viscous than the displaced fluid ( Γ $\ll$ 1 and M < 1) where we identify a self-similar solution that indicates a parabolic interface shape; (ii) injection-driven flow with injected and displaced fluids of equal viscosity ( Γ $\ll$ 1 and M = 1), where we find a self-similar solution that predicts a distinct parabolic interface shape; (iii) injection-driven flow with a less viscous injected fluid ( Γ $\ll$ 1 and M > 1) for which there is a rarefaction wave solution, assuming that the Saffman-Taylor instability does not occur at the reservoir scale; and (iv) buoyancy-driven flow ( Γ $\gg$ 1) for which there is a well-known self-similar solution corresponding to gravity currents in an unconfined porous medium [S. Lyle et al. “Axisymmetric gravity currents in a porous medium,” J. Fluid Mech. 543, 293–302 (2005)]. The various axisymmetric flows are summarized in a Γ - M regime diagram with five distinct dynamic behaviors including the four asymptotic regimes and an intermediate regime. The implications of the regime diagram are discussed using practical engineering projects of geological CO 2 sequestration, enhanced oil recovery, and underground waste disposal.

42 ENGINEERING↗

Study of a Double Bubbler for Material Balance in Liquids (Training Report 2013)

The objective of this project was to determine the potential of a double bubbler to measure density and fluid level of the molten salt contained in an electrorefiner. Such in-situ real-time measurements can provide key information for material balances in the pyroprocessing of the nuclear spent fuel. This theoretical study showed this technique has a lot of promise. Four different experiments were designed and performed. The first three experiments studied the influence of a variety of factors such as depth difference between the two tubes, gas flow rate, the radius of the tubes and determining the best operating conditions. The last experiment purpose was to determine the precision and accuracy of the apparatus during specific conditions. The elected operating conditions for the characterization of the system were a difference of depth of 25 cm and a flow rate of 55 ml/min in each tube. The measured densities were between 1,000 g/l and 1,400g/l and the level between 34cm and 40 cm. The depth difference between the tubes is critical, the larger, the better. The experiments showed that the flow rate should be the same in each tube. The concordances with theoretical predictions were very good. The density precision was very satisfying (spread<0.1%) and the accuracy was about 1%. For the level determination, the precision was also very satisfying (spread<0.1%), but the accuracy was about 3%. However, those two biases could be corrected with calibration curves. In addition to the aqueous systems studied in the present work, future work will focus on examining the behavior of the double bubbler instrumentation in molten salt systems. The two main challenges which were identified in this work are the effect of the temperature and the variation of the superficial tension.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Tissue factor pathway inhibitor prevents airway obstruction, respiratory failure and death due to sulfur mustard analog inhalation

Sulfur mustard (SM) inhalation causes airway injury, with enhanced vascular permeability, coagulation, and airway obstruction. The objective of this study was to determine whether recombinant tissue factor pathway inhibitor (TFPI) could inhibit this pathogenic sequence. Methods: Rats were exposed to the SM analog 2-chloroethyl ethyl sulfide (CEES) via nose-only aerosol inhalation. One hour later, TFPI (1.5 mg/kg) in vehicle, or vehicle alone, was instilled into the trachea. Arterial O{sub 2} saturation was monitored using pulse oximetry. Twelve hours after exposure, animals were euthanized and bronchoalveolar lavage fluid (BALF) and plasma were analyzed for prothrombin, thrombin–antithrombin complex (TAT), active plasminogen activator inhibitor-1 (PAI-1) levels, and fluid fibrinolytic capacity. Lung steady-state PAI-1 mRNA was measured by RT-PCR analysis. Airway-capillary leak was estimated by BALF protein and IgM, and by pleural fluid measurement. In additional animals, airway cast formation was assessed by microdissection and immunohistochemical detection of airway fibrin. Results: Airway obstruction in the form of fibrin-containing casts was evident in central conducting airways of rats receiving CEES. TFPI decreased cast formation, and limited severe hypoxemia. Findings of reduced prothrombin consumption, and lower TAT complexes in BALF, demonstrated that TFPI acted to limit thrombin activation in airways. TFPI, however, did not appreciably affect CEES-induced airway protein leak, PAI-1 mRNA induction, or inhibition of the fibrinolytic activity present in airway surface liquid. Conclusions: Intratracheal administration of TFPI limits airway obstruction, improves gas exchange, and prevents mortality in rats with sulfur mustard-analog-induced acute lung injury. - Highlights: • TFPI administration to rats after mustard inhalation reduces airway cast formation. • Inhibition of thrombin activation is the likely mechanism for limiting casts. • Rats given TFPI had improved tissue oxygenation, and mortality was prevented.

60 APPLIED LIFE SCIENCES↗

Petrophysical properties of saprolites from the Oak Ridge Integrated Field Research Challenge site, Tennessee

At the Oak Ridge Integrated Field Research Challenge site, near Oak Ridge, Tennessee, the shallow saprolitic aquifer is contaminated by nitric acid, uranium, and metals originating from the former S3 settling ponds. To interpret low-frequency geophysical methods used to image contaminant plumes, we have characterized the petrophysical properties of three representative saprolite core samples. Their hydraulic conductivity ranges from to in agreement with field data. Complex conductivity measurements, in the frequency range of 1 mHz to 45 kHz, were performed with NaCl solutions with electrical conductivities in the range to , a range representative of field conditions. The electrical conductivity data were well reproduced with a simple linear conductivity model between the saprolite conductivity and the pore water conductivity. The conductivity plots were used to estimate the formation factor (the cementation exponent was about ) and the surface conductivity ( ). The magnitude of the surface conductivity depended on the degree of weathering and therefore on the amount of smectite and mixed layer (illite-smectite) clays present in the saprolite. The chargeability of the core samples was in the range of and is strongly dependent on the salinity. We also performed streaming potential measurements with the same pore fluid composition as that used for the complex conductivity measurements. We found an excess of movable electrical charges on the order of 100 to in agreement with previous investigations connecting the movable excess charge density to permeability. The zeta potential was in the range of to independent on the salinity. The electrical measurements were consistent with an average cation exchange capacity in the range of 1.4 to and a specific surface area on the order of 4000 to about 30,000 . Read More: http://library.seg.org/doi/abs/10.1190/geo2012-0176.1

Revil, André↗

Opto-mechano-fluidic viscometer

The recent development of opto-mechano-fluidic resonators has provided—by harnessing photon radiation pressure—a microfluidics platform for the optical sensing of fluid density and bulk modulus. Here, we show that fluid viscosity can also be determined through optomechanical measurement of the vibrational noise spectrum of the resonator mechanical modes. A linear relationship between the spectral linewidth and root-viscosity is predicted and experimentally verified in the low viscosity regime. Our result is a step towards multi-frequency measurement of viscoelasticity of arbitrary fluids, without sample contamination, using highly sensitive optomechanics techniques.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Containers and systems for the measurement of radioactive gases and related methods

Containers for a fluid sample containing a radionuclide for measurement of radiation from the radionuclide include an outer shell having one or more ports between an interior and an exterior of the outer shell, and an inner shell secured to the outer shell. The inner shell includes a detector receptacle sized for at least partial insertion into the outer shell. The inner shell and outer shell together at least partially define a fluid sample space. The outer shell and inner shell are configured for maintaining an operating pressure within the fluid sample space of at least about 1000 psi. Systems for measuring radioactivity in a fluid include such a container and a radiation detector received at least partially within the detector receptacle. Methods of measuring radioactivity in a fluid sample include maintaining a pressure of a fluid sample within a Marinelli-type container at least at about 1000 psi.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Broadband Laboratory Study of the Seismic Properties of Cracked and Fluid-Saturated Synthetic Glass Media

In this paper, for better understanding of frequency dependence (dispersion) of seismic wave velocities caused by stress-induced fluid flow, broadband laboratory measurements were performed on a suite of synthetic glass media containing both equant pores and thermal cracks. Complementary forced oscillation, resonant bar, and ultrasonic techniques provided access to millihertz-hertz frequencies, ~1 kHz frequency, and ~1 MHz frequency, respectively. The wave speeds or effective elastic moduli and associated dissipation were measured on samples under dry, argon- or nitrogen-saturated, and water-saturated conditions in sequence. The elastic moduli, in situ permeability, and crack porosity inferred from in situ X-ray computed tomography all attest to strong pressure-induced crack closure for differential (confining-minus-pore) pressures <30 MPa, consistent with zero-pressure crack aspect ratios <4 × 10 -4 . The low permeabilities of these materials allow access to undrained conditions, even at subhertz frequencies. The ultrasonically measured elastic moduli reveal consistently higher shear and bulk moduli upon fluid saturation—diagnostic of the saturated-isolated regime. For a glass rod specimen, containing cracks but no pores, saturated-isolated conditions apparently persist to subhertz frequencies—requiring in situ aspect ratios (minimum/maximum dimension) <10 -5 . In marked contrast, the shear modulus measured at subhertz frequencies on a cracked glass bead specimen of 5% porosity, is insensitive to fluid saturation, consistent with the Biot-Gassmann model for the saturated-isobaric regime. Finally, the measured dispersion of the shear modulus approaches 10% over the millihertz-megahertz frequency range for the cracked and fluid-saturated media—implying that laboratory ultrasonic data should be used with care in the interpretation of field data.

58 GEOSCIENCES↗

Capturing soil moisture and salinity changes in flooded coastal forests using electrical resistivity and induced polarization

Geophysical methods provide high-resolution spatial measurements of physical quantities sensitive to changes in soil moisture and salinity and can be used to monitor soil hydrological responses to flooding. However, extracting quantitative hydrological information from geophysical data remains challenging. In this study, we extended existing petrophysical models to estimate soil moisture and salinity from electrical measurements to address this challenge. We manipulated two hydrologically isolated 2000 m 2 experimental plots by simultaneously inundating them with 265 m 3 of either freshwater or estuarine water. Repeated electrical resistivity and induced polarization measurements were used to image the water and solute infiltration along two transects that are 100 and 42 m in length. Petrophysical models derived from laboratory multi-salinity electrical measurements were used to estimate changes in soil moisture and fluid salinity from field measurements of real and imaginary conductivity during the ecosystem-scale flooding experiment. The real conductivity increased by ∼100% in the freshwater plot and ∼570% in the saltwater plot. The change in imaginary conductivity in the freshwater plot was <1 mS/m, whereas that of the estuarine water plot was ∼5 mS/m. Real conductivity shows dependence on soil moisture content with a coefficient of determination (R 2 ) > 0.7, while the imaginary conductivity shows a dependence on soil salinity with R 2 > 0.6. The results validate the use of electrical resistivity for estimating changes in soil moisture content in response to flooding. Combining electrical resistivity imaging with induced polarization measurements provides the possibility to account for changes in pore fluid conductivity.

Adebayo, Moses B. [Univ. of Toledo, OH (United Sta↗

Miniature Flow and Viscosity Sensors

Integration of flow sensing into microfluidic systems such as automated sample preparation and processing has seen limited applications due to the large cost and size of commercially available flow sensors. Nevertheless, flow sensing is a critical missing components for many high precision microfluidic applications. Los Alamos National Laboratory researchers have developed a miniature flow sensor technology based on a novel microfluidic method developed at the Laboratory. The method takes advantage of the fluid-structure interaction between the fluid and an elastic membrane to provide precision measurement. Depending on how it is integrated, it is also possible to use the technology to measure viscosity of the fluid. The flow sensor can work with a wide range of fluids.

47 OTHER INSTRUMENTATION↗

Chaos analysis of viscoelastic chaotic flows of polymeric fluids in a micro-channel

Many fluids, including biological fluids such as mucus and blood, are viscoelastic. Through the introduction of chaotic flows in a micro-channel and the construction of maps of characteristic chaos parameters, differences in viscoelastic properties of these fluids can be measured. This is demonstrated by creating viscoelastic chaotic flows induced in an H-shaped micro-channel through the steady infusion of a polymeric fluid of polyethylene oxide (PEO) and another immiscible fluid (silicone oil). A protocol for chaos analysis was established and demonstrated for the analysis of the chaotic flows generated by two polymeric fluids of different molecular weight but with similar relaxation times. The flows were shown to be chaotic through the computation of their correlation dimension (D{sub 2}) and the largest Lyapunov exponent (λ{sub 1}), with D{sub 2} being fractional and λ{sub 1} being positive. Contour maps of D{sub 2} and λ{sub 1} of the respective fluids in the operating space, which is defined by the combination of polymeric fluids and silicone oil flow rates, were constructed to represent the characteristic of the chaotic flows generated. It was observed that, albeit being similar, the fluids have generally distinct characteristic maps with some similar trends. The differences in the D{sub 2} and λ{sub 1} maps are indicative of the difference in the molecular weight of the polymers in the fluids because the driving force of the viscoelastic chaotic flows is of molecular origin. This approach in constructing the characteristic maps of chaos parameters can be employed as a diagnostic tool for biological fluids and, more generally, chaotic signals.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Toward predictive permeabilities: Experimental measurements and multiscale simulation of methanol transport in Nafion

A polymer membrane's permeability to solutes determines its suitability for various applications: a permeability value is essential for predicting performance in diverse contexts. Using aqueous methanol permeation through Nafion as an example, we describe a methodology for determining membrane permeability that accounts for boundary layer effects and the possibility of swelling. For the materials and apparatus used herein, analysis of a permeance measurement and computational fluid dynamics simulations show that the mass transfer boundary layer is on the order of ones to tens of microns. Additionally, the data are used to develop and validate a multiscale model describing solute permeation through a hydrated membrane as a series of physical mechanistic steps: reversible adsorption from solution at the membrane interface, diffusion driven by a concentration gradient within the membrane, and reversible desorption into solution at the opposite membrane interface. The validated model is used to predict methanol transport across a solar-driven CO 2 reduction device and to assess the impact of polymer changes on the measured value. The approach of combining experimental data, computational fluid dynamics, and the mechanistic multiscale model is expected to provide more accurate analysis of membrane permeation data in cases with polymer swelling or unusual device geometries, among others.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The role of stress and fluid saturation on the acoustic response of fractured rock

Standard rock physics models are formulated to describe the behavior of porous sedimentary reservoirs, with clean sandstones being the archetypal system; however, many situations demand geophysical monitoring of rocks with significantly different structures, such as low porosity, fractured reservoirs. Conventional models also suggest that these “stiff” reservoirs can be challenging to monitor seismically due to small fluid substitution effects, but the presence of fractures leads to stress dependence which may be leveraged for remote monitoring purposes. Using samples from the Duperow Formation (dolostone) obtained from the Danielson test well in Kevin Dome, MT, we conducted ultrasonic and multi-scale structural (profilometry, synchrotron micro-tomography, pressure sensitive film) measurements on naturally fractured core in order to characterize the effects of fluid substitution and effective stress on the acoustic response of fractured reservoir rock with a focus in particular on the textural and seismic characteristics of natural fractures. We find that changes in effective stress can yield changes in velocity of up to 20% and changes in attenuation up to 200%. Measured fluid substitution effects are resolvable, but stress effects dominate. These measurements provide insight into the physical processes controlling acoustic response of fractured rocks in general and can also be used to inform monitoring efforts in fractured reservoirs.

58 GEOSCIENCES↗

Simultaneous Real-Time Measurement of Composition, Flow, Attenuation, Density, and Pipe-Wall Thickness in Multiphase Fluids

Researchers at Los Alamos National Lab have developed an apparatus and method for making simultaneous measurements of composition, fluid flow, and sound attenuation in a multiphase fluid flowing through a pipe in real-time, using a single device. Additionally, the apparatus provides real-time pipe-wall thickness monitoring for observing pipe corrosion. The use of short-duration frequency chirp excitation enables the apparatus to provided multiple levels of information in a single measurement.

42 ENGINEERING↗

Viscosity-dependent drain current noise of AlGaN/GaN high electron mobility transistor in polar liquids

The drain current fluctuation of ungated AlGaN/GaN high electron mobility transistors (HEMTs) measured in different fluids at a drain-source voltage of 0.5 V was investigated. The HEMTs with metal on the gate region showed good current stability in deionized water, while a large fluctuation in drain current was observed for HEMTs without gate metal. The fluctuation in drain current for the HEMTs without gate metal was observed and calculated as standard deviation from a real-time measurement in air, deionized water, ethanol, dimethyl sulfoxide, ethylene glycol, 1,2-butanediol, and glycerol. At room temperature, the fluctuation in drain current for the HEMTs without gate metal was found to be relevant to the dipole moment and the viscosity of the liquids. A liquid with a larger viscosity showed a smaller fluctuation in drain current. The viscosity-dependent fluctuation of the drain current was ascribed to the Brownian motions of the liquid molecules, which induced a variation in the surface dipole of the gate region. This study uncovers the causes of the fluctuation in drain current of HEMTs in fluids. The results show that the AlGaN/GaN HEMTs may be used as sensors to measure the viscosity of liquids within a certain range of viscosity.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Method for noninvasive determination of acoustic properties of fluids inside pipes

A method for determining the composition of fluids flowing through pipes from noninvasive measurements of acoustic properties of the fluid is described. The method includes exciting a first transducer located on the external surface of the pipe through which the fluid under investigation is flowing, to generate an ultrasound chirp signal, as opposed to conventional pulses. The chirp signal is received by a second transducer disposed on the external surface of the pipe opposing the location of the first transducer, from which the transit time through the fluid is determined and the sound speed of the ultrasound in the fluid is calculated. The composition of a fluid is calculated from the sound speed therein. The fluid density may also be derived from measurements of sound attenuation. Several signal processing approaches are described for extracting the transit time information from the data with the effects of the pipe wall having been subtracted.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗