Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FIBERGLASS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Process Development for Stamping Á-Pillar Covers with Aluminum

In this work, performed in close collaboration with PACCAR and Magna International, a 6XXX series aluminum alloy was used for the development of A-Pillar cover for the cab of a typical heavy-duty Class-8 truck. The use of Al alloy for the A-pillar cover represents an approximately 40% weight savings over its steel or molded fiberglass composite counterpart. For the selected Al alloy, a small amount of cold work (5% tensile strain), following prior hot-forming, was found to significantly improve the subsequent age-hardening response. The role of solutionizing temperature and rate of cooling on the age-hardening response after paint-bake treatment were investigated. For the temperature range selected in this work, higher solutionizing temperature correlated with greater subsequent age-hardening and vice-versa. However, the age-hardening response was insensitive to the mode of cooling (water quench vs. air cooling). Finally, a two-step forming process was developed where, in the first step, the blank was heated to solutionizing temperature, quenched, and then partially formed at room temperature. For the second step, the pre-form was re-heated and quenched as in the first step, and the forming was completed at room temperature. The resulting A-pillars had sufficient residual ductility to be compatible with hemming and riveting

A-pillar cover↗

Infusible acrylic thermoplastic resins: Tailoring of chemorheological properties

Infusible liquid resins that polymerize into a thermoplastic are desirable for many applications. Similar to unsaturated and vinylester thermosetting systems, they consist of polymers dissolved in reactive monomer. This work presents a method to decrease cycle time by tuning the molecular weight and concentration of the predissolved polymer in the resin. Variation of these properties allows precise control of the viscosity which in turn controls the time at which peak exotherm is reached, the maximum temperature for a given part thickness, and cure time. In this work, predictive models for the viscosity dependence on molecular weight, polymer concentration, shear rate, and temperature are developed. Two fiberglass panels are fabricated and tested; one with a lower molecular weight ($M_w$~30 kg mol –1 ) poly(methyl methacrylate) dissolved in methyl methacrylate and the second with higher molecular weight ($M_w$~500 kg mol –1 ) predissolved polymer in the resin. Mechanical properties are indistinguishable but the lower molecular weight panel cures up to three times faster.

36 MATERIALS SCIENCE↗

Structure-property relationships and recyclability of natural fiber insulation

Thermal insulation can significantly decrease the energy required to maintain internal temperatures within buildings, saving money and decreasing environmental impacts. Many industrially available insulation options utilize petroleum-derived materials, such as polyurethane, fiberglass, and polystyrene, which can be detrimental to the environment by emitting greenhouse gases during production. A sustainable alternative to these synthetic insulations is the use of renewable feedstocks to produce comparable insulation products. In this work, natural fibers such as flax and banana were bound with an epoxy system to produce natural-fiber insulation. Key experimental parameters for this study included evaluating the fiber lengths and processing methods while varying the viscosity of the epoxy binder solvent dissolution. Insulation performance was determined by comparing density, thermal conductivity, resilience, and compressive strength; these parameters were tested to further understand and investigate the structure- property relationships within the system and to understand how these composites compare to current commercial materials. Furthermore, from this characterization and optimization, a natural fiber sample with an R/in. >5 was achieved, making these materials competitive with commercial alternatives.

Compressive strength↗

Extracting single fiber transverse and shear moduli from off-axis misalignment fiber tensile testing

Small diameter (<100 μm) fibers (e.g. carbon fibers, Kevlar, and fiberglass) and wires (e.g. ultrafine copper and aluminum wires) are frequently used in many different engineering applications, such as for light weighting structures, electromagnetic shielding for aircraft/infrastructure/EVs, vibration damping, biological sensors, aerospace electrical devices, and electric windings just to name a few. Due to the manufacturing process, the fibers and wires are pulled and stretched to produce a preferential alignment. Therefore, thin fibers and wires typically display different properties along the length of the fiber as opposed to their cross section and many fibers/wires are considered transversely isotropic. The axial properties of fibers/wires can be ascertained via tensile testing of single-filaments or fiber tows, but the radial properties require much more effort to measure. Knowing these properties is important for the accurate prediction of micromechanical models and manipulation of fibers during micromanufacturing. In this paper, a new technique was developed to determine the transverse/shear moduli and strength of a material by conducting tensile tests of the material at increasing misalignment angles from the tensile axis. Due to the transversely isotropic nature of the material, the transverse/shear moduli and strength influence the experimental results recorded by the test machine to different degrees based on the amount of misalignment in the test setup. An equation was derived to determine the influence of each of the material properties based on the misalignment angle by manipulating the stiffness matrix for transversely isotropic materials using the transformation matrices. Then, curve fitted coefficients were used to identify the material properties. Here, the strengths were similarly determined by curve fitting an off-axis Tsai-Hill failure criteria to determine the influence of transverse, shear, and tensile strengths based on the complex loading condition provided by the off-axis tensile test. Zoltek Panex 35 carbon fibers were used to demonstrate this new technique and the determined properties were then compared to those obtained from nanoindentation and from literature. Fracture surfaces provide insight into the different failure mechanisms at various misalignment angles.

36 MATERIALS SCIENCE↗

Chemical changes in thirdhand smoke associated with remediation using an ozone generator

Ozonation is a common remediation approach to eliminate odors from mold, tobacco and fire damage in buildings. Little information exists to: 1) assess its effectiveness; 2) provide guidance on operation conditions; and 3) identify potential risks associated with the presence of indoor ozone and ozonation byproducts. The goal of this study is to evaluate chemical changes in thirdhand smoke (THS) aerosols induced by high levels of ozone, in comparison with THS aerosols aged under similar conditions in the absence of ozone. Samples representing different stages of smoke aging in the absence of ozone, including freshly emitted secondhand smoke (SHS) and THS, were collected inside an 18-m 3 room-sized chamber over a period of 42 h after six cigarettes were consumed. The experiments involved collection and analysis of gas phase species including volatile organic compounds (VOCs), volatile carbonyls, semivolatile organic compounds (SVOCs), and particulate matter. VOC analysis was carried out by gas chromatography/mass spectrometry with a thermal desorption inlet (TD-GC/MS), and volatile carbonyls were analyzed by on-line derivatization with dinitrophenylhydrazine (DNPH), followed by liquid chromatography with UV/VIS detection. SVOCs were extracted from XAD-coated denuders and Teflon-coated fiberglass filters in the absence of ozone. In those extracts, tobacco-specific nitrosamines (TSNAs) and other SVOCs were analyzed by gas chromatography with positive chemical ionization-triple quadrupole mass spectrometric detection (GC/PCI-QQQ-MS), and polycyclic aromatic hydrocarbons (PAHs) were quantified by gas chromatography with ion trap mass spectrometric detection (GC/IT-MS) in selected ion monitoring mode. Particulate matter concentration was determined gravimetrically. In a second experiment, a 300 mg h -1 commercial ozone generator was operated during 1 h, one day after smoke was generated, to evaluate the remediation of THS by ozonation. VOCs and volatile carbonyls were analyzed before and after ozonation. Extracts from fabrics that were exposed in the chamber before and after ozonation as surrogates for indoor furnishings were analyzed by GC/IT-MS, and aerosol size distribution was studied with a scanning mobility particle sizer. Ozone concentration was measured with a photometric detector. An estimated 175 mg ozone reacted with THS after 1 h of treatment, corresponding to 58% of the total O 3 released during that period. Fabric-bound nicotine was depleted after ozonation, and the surface concentration of PAHs adsorbed to fabric specimens decreased by an order of magnitude due to reaction with ozone, reaching pre-smoking levels. These results suggest that ozonation has the potential to remove harmful THS chemicals from indoor surfaces. However, gas phase concentrations of volatile carbonyls, including formaldehyde, acetaldehyde and acetone were higher immediately after ozonation. Ultrafine particles (UFP, in most cases with size <60 nm) were a major ozonation byproduct. UFP number concentrations peaked shortly after ozonation ended, and remained at higher-than background levels for several hours. Based on these results, minimum re-entry times after ozone treatment were predicted for different indoor scenarios. Clearly defining re-entry times can serve as a practical measure to prevent acute exposures to ozone and harmful ozonation byproducts after treatment. This study evaluated potential benefits and risks associated with THS remediation using ozone, providing insights into this technology.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Laboratory pull-out tests on fully grouted rock bolts and cable bolts: Results and lessons learned

Laboratory pull-out tests were conducted on the following rock bolts and cable bolts: steel rebars, smooth steel bars, fiberglass reinforced polymer threaded bolts, flexible cable bolts, IR5/IN special cable bolts and Mini-cage cable bolts. The diameter of the tested bolts was between 16 mm and 26 mm. The bolts were grouted in a sandstone sample using resin or cement grouts. The tests were conducted under either constant radial stiffness or constant confining pressure boundary conditions applied on the outer surface of the rock sample. In most tests, the rate of displacement was about 0.02 mm/s. The tests were performed using a pull-out bench that allows testing a wide range of parameters. This paper provides an extensive database of laboratory pull-out test results and confirms the influence of the confining pressure and the embedment length on the pull-out response (rock bolts and cable bolts). Furthermore, it also highlights the sensitivity of the results to the operating conditions and to the behavior of the sample as a whole, which cannot be neglected when the test results are used to assess the bolt-grout or the grout–rock interface.

42 ENGINEERING↗

A high-precision miniaturized rotating coil transducer for magnetic measurements

A miniaturized Printed Circuit Board (PCB) sensing coil, jointly developed by CERN and Fermilab for measuring the field of small-gap (less than 10 mm) accelerator magnets, is illustrated. A sensing coil array, with a scheme for compensating the main field when measuring the harmonic error components, hosted on a synthetic sapphire-based transducer, is presented. Key innovating features are (i) very-small size, both for the sensing coil array (thickness of 1.380 mm) and for the transducer (overall diameter of 7.350 mm), (ii) metrological performance, namely accuracy (more than five times better than state of the art), and 1-sigma repeatability (ten times better on harmonics with amplitude less than 100 ppm), and (iii) manufacturing technology of both the coil array (13 double layers aligned within 10 μm), and the sapphire support (concentricity, the most important uncertainty source for rotating coils, 3 μm of uncertainty, namely one order of magnitude better than fiberglass support). After stating the measurement problem, the design of the transducer and a case study of a two-layer PCB sensor array are also illustrated. Then, the prototyping and quality control of both the sensor and the transducer are discussed. Furthermore, the calibration and the results obtained with a prototype setup at Fermilab are presented. Finally, in the appendix, the theory of the rotating coil, the sensor geometry, and the harmonic compensation are briefly reviewed for the reader easiness.

06.20.fb/calibration↗

A non-volatile thermal switch for building energy savings

Compared with traditional static insulation, a thermally switchable building envelope could reduce annual heating and cooling loads by intermittently coupling to the outside environment when beneficial. Here, we demonstrate a voltage-actuated, contact/non-contact thermal switch that meets the unique challenges of this application. The switch is non-volatile, consuming electricity only briefly while switching and none to hold steady state. The switch ratio is 12, the off state has a low effective thermal conductivity of 0.045 W m -1 K -1 , comparable to fiberglass insulation, and the performance is stable over 1,000 switching cycles. Numerical simulations using real-world climate data show that combining this thermal switch with a thermal storage layer in a building envelope can yield annual energy savings of 9%-55% (heating) and 17%-76% (air conditioning), depending on the climate zone. The greatest benefits are realized when the exterior temperature crosses well above and below the desired interior temperature within a single 24 h period.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Renewable unsaturated polyesters from muconic acid

cis,cis -Muconic acid is an unsaturated dicarboxylic acid that can be produced in high yields via biological conversion of sugars and lignin-derived aromatic compounds. Muconic acid is often targeted as an intermediate to direct replacement monomers such as adipic or terephthalic acid. However, the alkene groups in muconic acid provide incentive for its direct use in polymers, for example, in the synthesis of unsaturated polyester resins. Here, biologically derived muconic acid is incorporated into polyesters via condensation polymerization using the homologous series of poly(ethylene succinate), poly(propylene succinate), poly(butylene succinate), and poly(hexylene succinate). Additionally, dimethyl cis,cis -muconate is synthesized and subsequently incorporated into poly(butylene succinate). NMR measurements demonstrate that alkene bonds are present in the polymer backbones. In all cases, the glass transition temperatures are increased whereas the melting and degradation temperatures are decreased. In the case of poly(butylene succinate), utilization of neat muconic acid yields substoichiometric incorporation consistent with a tapered copolymer structure, whereas the muconate diester exhibits stoichiometric incorporation and a random copolymer structure based on thermal and mechanical properties. Prototypical fiberglass panels were produced by infusing a mixture of low molecular weight poly(butylene succinate-co-muconate) and styrene into a woven glass mat and thermally initiating polymerization resulting in thermoset composites with shear moduli in excess of 30 GPa, a value typical of commercial composites. The increased glass transition temperatures with increasing mucconic incorporation leads to improved composites properties. We find that the molecular tunability of poly(butylene succinate-co-muconate) as a tapered or random copolymer enables the tunability of composite properties. Altogether, this study demonstrates the utility of muconic acid as a monomer suitable for direct use in commercial composites.

09 BIOMASS FUELS↗

Biomass-derived monomers for performance-differentiated fiber reinforced polymer composites

Nearly all polymer resins used to manufacture critically important fiber reinforced polymer (FRP) composites are petroleum sourced. In particular, unsaturated polyesters (UPEs) are widely used as matrix materials and are often based on maleic anhydride, a four-carbon, unsaturated diacid. Typically, maleic anhydride is added as a reactant in a conventional step-growth polymerization to incorporate unsaturation throughout the backbone of the UPE, which is then dissolved in a reactive diluent (styrene is widely used) infused into a fiber mat and cross-linked. Despite widespread historical use, styrene has come under scrutiny due to environmental and health concerns; in addition, many conceivable UPEs are not soluble in styrene. In this study, we demonstrate that renewably-sourced monomers offer the ability to overcome these issues and improve overall composite performance. The properties of poly(butylene succinate)-based UPEs incorporating maleic anhydride are used as a baseline for comparison against UPEs derived from fumaric acid, cis , cis -muconate, and trans , trans -muconate, all of which can be obtained biologically. The resulting biobased UPEs are combined with styrene, methacrylic acid, or a mixture of methacrylic acid and cinnaminic acid, infused into woven fiberglass and cross-linked with the addition of a free-radical initiator and heat. This process produces a series of partially or fully bio-derived composites. Overall, the muconate-containing UPE systems exhibit a more favorable property suite than the maleic anhydride and fumaric acid counterparts. In all cases at the same olefinic monomer loading, the trans , trans -muconate polymers exhibit the highest shear modulus, storage modulus, and glass transition temperature indicating stronger and more thermally resistant materials. They also exhibit the lowest loss modulus indicating a greater adhesion to the glass fibers. The use of a mixture of methacrylic and cinnaminic acid as the reactive diluent results in a FRP composite with properties that can be matched to reinforced composites prepared with styrene. Significantly, at one-third the monomer loading (corresponding to two-thirds the number of double bonds), trans , trans -muconate produces approximately the same storage modulus and glass transition temperature as maleic anhydride, while exhibiting a superior loss modulus. Altogether, this work demonstrates the novel synthesis of performance-differentiated FRP composites using renewably-sourced monomers.

09 BIOMASS FUELS↗

High Chrome Refractory Characterization: Part I. Impact of Melt Reduction/Oxidation on the Corrosion Mechanism

High Cr 2 O 3 containing Monofrax ™ K‐3 is a robust refractory that is used in the fiberglass industry and used in radioactive waste glass melters worldwide. Monofrax ™ K‐3 is tolerant of transition metal oxides but contains highly reduced solid solutions of spinels, that is, (Mg,Fe 2+ )(Al,Cr) 2 O 3 . Conversely, many of the waste feeds being processed are highly oxidizing. The K‐3 refractory corrosion was tested in sealed crucibles starting with slurried melter feed instead of prereacted glass called for by ASTM C621. Testing the refractory coupon during the feed‐to‐glass conversion exposes the refractory to the oxidizing and reducing species being released during vitrification, for example, NO 3 − , NO 2 − , CO 2 , CO , O 2 . Corrosion rates measured in highly oxidizing (high nitrate) feeds were ~1.8–2.8 times higher than those determined using prereacted glass or reduced feeds. Confirmatory corrosion rates were measured on Monofrax ™ K‐3 coupons immersed in oxidizing feed in a 1/100th‐scale HLW pilot‐scale melter. Corrosion is heterogeneous or incongruent as Ni and Fe in the waste glass exchange with Mg and Al in the refractory. An insoluble NiFe 2 O 4 spinel corrosion product is formed that can build up a protective layer along the refractory walls or spall and settle to the melter floor depending on melt pool convection/agitation.

Jantzen, Carol M.↗

Hybrid Li-S pouch cell with a reinforced sulfide glass solid-state electrolyte film separator

Here, in this paper, sulfide glass electrolyte powder with a nominal composition of (Li 2 S) 60 (SiS 2 ) 28 (P 2 S 5 ) 12 is hot pressed at a 330°C and 12 MPa into separator films using non-woven fiberglass reinforcement. The reinforced separator films are 93% dense, bendable, and have an ionic conductivity of 0.7 mS/cm at room temperature. When integrated into hybrid Li-S coin cells with liquid electrolyte, these reinforced glass separators blocked the parasitic polysulfide shuttle sufficiently to enable reversible cycling without LiNO 3 co-salt. Furthermore, the scalability of the reinforced glass separator technology is demonstrated by assembling and testing a hybrid single-layer pouch cell.

25 ENERGY STORAGE↗

Manufacturing a 9-Meter Thermoplastic Composite Wind Turbine Blade: Preprint

Currently, wind turbine blades are manufactured from a combination of glass and/or carbon fiber composite materials with a thermoset resin such as epoxy, which requires energy-intensive and expensive heating processes to cure. Newly developed in-situ polymerizing thermoplastic resin systems for composite wind turbine blades polymerize at room temperature, eliminating the heating process and significantly reducing the blade manufacturing cycle time and embodied energy, which in turn reduces costs. Thermoplastic materials can also be thermally welded, eliminating the need for adhesive bonds between blade components and increasing the overall strength and reliability of the blades. As well, thermoplastic materials enable end-of-life blade recycling by reheating and decomposing the materials, which is a limitation of existing blade technology. This paper presents a manufacturing demonstration for a 9-m-long thermoplastic composite wind turbine blade. This blade was constructed in the Composites Manufacturing Education and Technology facility at the National Wind Technology Center at the National Renewable Energy Laboratory (NREL) using a vacuum-assisted resin transfer molding process. Johns Manville fiberglass and an Arkema thermoplastic resin called Elium were used. Additional materials included Armacell-recycled polyethylene terephthalate foam from Creative Foam and low-cost carbon- fiber pultruded spar caps (manufactured in collaboration with NREL, Oak Ridge National Laboratory, Huntsman, Strongwell, and Chomarat). This paper highlights the development of the thermoplastic resin formulations, including an additive designed to control the peak exothermic temperatures. Infusion and cure times of less than 3 hours are also demonstrated, highlighting the efficiency and energy savings associated with manufacturing thermoplastic composite blades.

17 WIND ENERGY↗

Deep Penetration in Aerospace Composite Materials Using Near-Infrared Laser Radiation

Previous work on lethality against composite material targets considered only surface deposition of laser energy, with lethality achieved via target penetration or material removal by ply separation, delamination, and blow-off in high-speed airflow. To produce lethal effect in a militarily relevant timescale, typically on the order of seconds, requires laser irradiance in the range of ten to a few hundred kilowatts per cm2. This Feasibility Study discovers that volume heating, either by direct in-depth absorption of laser energy, for example in near-infrared (IR) laser irradiation of translucent fiberglass composite, or by rapid conduction of surface-deposited energy as in the case of opaque carbon composite, can induce failure under load in seconds by softening the resin matrix at irradiance less than 100 W/cm2 – one to three orders of magnitude lower than the intensity required to produce lethal effect by target penetration or material removal.

42 ENGINEERING↗

Lucid Energy Inc. In-Conduit Hydropower. Final Research Performance Progress Report

With the goal of commercializing the LucidPipe Power System (LucidPipe) in late 2012, Lucid Energy performed much research and testing of turbines, particularly focusing on understanding and mitigating cavitation and improving performance, as well as to improve data acquisition, monitoring and control of the LucidPipe system. Lucid Energy developed a 24” version of the LucidPipe to complement the 42” system, which had been the primary focus up to that point. Lucid Energy replaced the prototype system in Riverside, California with a new system that included a bypass pipe in order to provide year-round access to the turbine, as well as replacing the temporary “trench box” in which it formerly resided with a poured concrete vault. This system was commissioned in January 2012 and has been operational since that time. This new system was the first LucidPipe version to utilize fiberglass composite blades with an improved blade profile and bolted end connections. Using the accelerated test methodology developed by the Fracture Mechanics and Materials Durability Laboratory at the University of Illinois, Lucid Energy evaluated various composite blade materials and coatings in order to select a material with optimum resistance to cavitation. Various other components have been designed, and Lucid Energy has worked with several suppliers to improve the capabilities of purchased components such as seals, bearings and mechanical brakes. These improvements were primarily to increase the robustness of the LucidPipe systems for use in commercial applications. Lucid Energy performed testing on series inline turbines at the Utah Water Research Laboratory Page 36 of 44 in order to evaluate the performance implications of installing LucidPipe systems consisting of multiple inline turbines in commercial applications. Lucid Energy is currently planning to install a commercial four-turbine, 42” system in Portland, Oregon in the first quarter of 2013 and a three-turbine 24” system at San Antonio Water System in San Antonio, Texas in the second quarter of 2013.

13 HYDRO ENERGY↗

Energy Implications of In-Line Filtration in California

Occupant concern about indoor air quality (IAQ) issues has led to the increased use of more effective air filters in residential heating and cooling systems. This study performed measurements in ten California houses to determine the effects of changing filter performance and related characteristics on the energy use of the heating and cooling systems. Multiple filters were evaluated covering a wide range of filter effectiveness from simple low filtration fiberglass filters up to high efficiency filters that might be used by occupants concerned about IAQ. Sophisticated analysis and simulation tools used the field-testing results to determine filter impacts for a wide range of parameters and California climates. The results indicate that for MERV 10/11/13 filters the effects on energy use are moderate (<5%) over a wide range of performance conditions and climates. Using higher MERV 16 filters can lead to significantly increased energy use (>5%). The high airflow resistance of MERV 16 filters led to excess noise in some test houses from air bypassing the filter and the blower motor. Filter loading rates varied more from house to house than by MERV rating and overall were quite low in many of the homes. Filter related energy use does not need to be addressed for filters of MERV 10/11/13 and MERV 16 filters should only be used with low leakage tested ducts unless the filter is mounted at the blower compartment. MERV 16 filters should only be used if the filter area is sufficient to prevent noise issues and if the duct system has low air flow resistance and low leakage. Filters should be labeled for their air flow resistance, or static pressure at a particular flow rate, that would allow codes and standards to reference a particular performance specification and allow contractors and homeowners to make informed purchases.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Structural Testing of the Blade Reliability Collaborative Effect of Defect Wind Turbine Blades

Two 8.3-meter (m) wind turbine blades intentionally constructed with manufacturing flaws were tested to failure at the National Wind Technology Center (NWTC) at the National Renewable Energy Laboratory (NREL) south of Boulder, Colorado. Two blades were tested; one blade was manufactured with a fiberglass spar cap and the second blade was manufactured with a carbon fiber spar cap. Test loading primarily consisted of flap fatigue loading of the blades, with one quasi-static ultimate load case applied to the carbon fiber spar cap blade. Results of the test program were intended to provide the full-scale test data needed for validation of model and coupon test results of the effect of defects in wind turbine blade composite materials. Testing was part of the Blade Reliability Collaborative (BRC) led by Sandia National Laboratories (SNL). The BRC seeks to develop a deeper understanding of the causes of unexpected blade failures (Paquette 2012), and to develop methods to enable blades to survive to their expected operational lifetime. Recent work in the BRC includes examining and characterizing flaws and defects known to exist in wind turbine blades from manufacturing processes (Riddle et al. 2011). Recent results from reliability databases show that wind turbine rotor blades continue to be a leading contributor to turbine downtime (Paquette 2012).

17 WIND ENERGY↗

Moisture Research—Optimization of Wall Assemblies

In this project, the Consortium for Advanced Residential Buildings (CARB) team evaluated several different configurations of wall assemblies to determine the accuracy of moisture modeling and make recommendations to ensure durable, efficient assemblies. WUFI and THERM were used to model the hygrothermal and heat transfer characteristics of these walls. Wall assemblies evaluated included code minimum walls using spray foam insulation and fiberglass batts, high R-value walls at least 12 in. thick (R-40 and R-60 assemblies), and brick walls with interior insulation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗