Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FEED SYSTEM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Mercury Speciation During Vitrification of LAW

n this work, laboratory and engineering-scale tests were conducted that mimic the reactive environment of the Hanford Tank Waste Treatment and Immobilization Plant (WTP) low activity waste (LAW) melter and off-gas system in order to assess the speciation of mercury at select points in the processing system. The experimental protocols, test equipment, feed materials used, and rationale for testing are detailed in the Test Plan for this work. Particular attention was paid to the amount and speciation of mercury in submerged bed scrubber (SBS) solutions, which are intended to be recycled back to the melter feed at the WTP. Results are presented from detailed mercury analysis of these solutions using Environmental Protection Agency (EPA) Method 1630 and modifications to this method for dimethyl mercury and methyl mercury as well as EPA Method 1631 and modifications to this method for total, dissolved, elemental, suspended, and ionic mercury. Testing was conducted in two separate sets of experiments: (1) One set of tests (crucible-scale furnace tests) that involved heating small batches of mercury-spiked melter feed in crucibles to determine the amount of mercury retained in the glass and the species of mercury in the exhaust gases; (2) A second set of tests (DM10 melter tests) was planned that involved creating LAW melter plenum gas compositions using the DM10 melter system, injecting mercury into the off-gas stream, and passing that stream though a reactor that simulates various plenum gas conditions. Operational issues led to the need to use one of the VSL DM100 melters in place of the planned DM10 melter for these tests. The speciation of mercury after exposure to those conditions was monitored. In both sets of tests, the exhaust gases were run through a scrubber that was intended to mimic the LAW SBS in order to determine how much of the mercury exiting the melter would be retained in the primary off-gas system fluids and in what form. After passing through the SBS, the exhaust stream was analyzed to determine particulate, ionic, elemental, and total mercury passing downstream of the SBS. In tests employing gases derived from the DM100 melter that were spiked with elemental mercury, the processing system provided gas temperatures and residence times that are representative of the WTP LAW vitrification system in order to assess the effect of those conditions on mercury speciation. The Decontamination Factor (DF) across the system in the tests with mercury-spiked DM100 melter exhaust was determined using the analytical data from EPA Method 30B (Fluegas Adsorption Mercury Speciation (FAMS TM )) exhaust samples and the amount of mercury detected in the SBS solutions. Mercury species used in melter feed crucible scale tests were divalent (chloride and iodide), monovalent (chloride and fluoride), and elemental mercury. Individual tests included only a single form of mercury in the feed. The results for total mercury mass balances in the crucible tests are also presented.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Ion Exchange Processing of AP-105 Hanford Tank Waste through Crystalline Silicotitanate in a Staged 2- then 3-Column System (Rev.1)

The Tank Side Cesium Removal (TSCR) system, under development by Washington River Protection Solutions LLC (WRPS), will send initial low-activity Hanford waste tank supernate feeds to the Hanford Waste Treatment and Immobilization Plant (WTP) Low-Activity Waste (LAW) Facility. In addition to entrained solids removal from the supernate, the primary goal of TSCR is to remove cesium-137 ( 137 Cs) by ion exchange, allowing contact handling of the liquid effluent product at the WTP. Crystalline silicotitanate (CST) ion exchange media, manufactured by Honeywell UOP, LLC (product IONSIVTM R9140-B), was selected as the ion exchange media at TSCR. CST is a non-elutable inorganic material that has demonstrated robust chemical, physical, and radiation tolerance while maintaining functionality. However, exchange kinetics of Cs onto CST is slow, resulting in low utilization of the CST Cs load capacity before unacceptable Cs breakthrough. Two process flow designs have been tested, as follows. 1. Lead-lag column processing: The lead column was removed after the lag column effluent reached the waste acceptance criteria (WAC) limit, the lag column was moved into the lead position, and a new lag column was installed. This format used ~52% Cs load capacity on the lead column. 2. Lead-lag-polish column processing: The processing was stopped when the polish column effluent reached the WAC limit. This format resulted in 81% Cs load capacity on the lead column. Testing with diluted feed from Hanford tank AP-105 (AP-105DF) incorporated a nuanced change to the lead-lag-polish column system where the polish column was inserted when the lag column effluent reached WAC limit. A 10.9-L volume of AP-105DF (diluted to 5.6 M Na) was processed through the Direct Feed Test Platform system, established at Pacific Northwest National Laboratory to support small-scale waste qualification efforts. The columns consisted of 10-mL CST beds (CST Lot 2002009604, sieved to screen out >30-mesh particles) placed in 1.5-cm-inner-diameter columns. Feed was processed at 1.83 bed volumes (BV) per hour; the flowrate, in terms of contact time with the CST bed, matched the expected flowrate at TSCR. The <30-mesh CST sieve cut was expected to provide appropriate performance scaling to a full-height column. The installation of the polish column later in processing (after processing 523 BVs) did not appear to fundamentally change the utilization of the lead column for Cs exchange nor did it extend the total feed processing volume when compared to the previous test with AP-107 feed. Table ES.1 and Figure ES.1 summarize the measured AP-105DF Cs load performance.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Iodine Speciation Effects in LAW Feeds

Tests were conducted on a DM10 vitrification system with prototypical off-gas treatment system, which includes an SBS, WESP, and evaporator based on the design of the evaporator to be installed at the WTP for concentration of the liquid effluents. This allowed determination of the partitioning and speciation of iodine between the melter and the off gas system components, including liquid effluents from the SBS and WESP as well as in the evaporator condensate and concentrate. Evaporator testing was decoupled from melter testing to permit filtration and pH adjustments of process solutions prior to evaporation. In addition, a slip stream was pulled from the exhaust downstream of the WESP and High-Efficiency Particulate Air (HEPA) filters and passed through a caustic scrubber simulating the WTP caustic scrubber to assess iodine partitioning to the caustic scrubber liquid effluent. The tests were conducted using simulated Hanford LAW from tank AP-107, which is the planned first feed for Direct Feed LAW (DFLAW) operations, at a nominal feed concentration of 5.6 molar Na over about 120 hours of testing.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

High Solids Performance Testing in a Scaled TSCR System

The Tank Side Cesium Removal (TSCR) project is a technology demonstration that will pretreat Hanford tank waste supernatant in support of the Direct Feed Low-Activity Waste (DFLAW) mission. The TSCR system employs two key separation technologies: dead-end filtration (DEF) and ion exchange (IX) using crystalline silicotitanate (CST) media. DEF will be used to remove undissolved solids from tank waste to protect the functionality of the IX columns and the IX system will remove Cs-137 from tank waste. The separation technologies (DEF and IX) used in TSCR are technically mature and have also been successfully deployed at the Savannah River site in a similar facility known as the Tank Closure Cesium Removal (TCCR) system. While testing with simulants and real waste has been successfully performed under conditions expected during the initial operation of TSCR, test data is absent for assessing off normal high solids loading that may be in the TSCR waste feed. Normal TSCR treatment operations are expected to handle wastes with solids content on the order of 200 ppm, and off normal solids loading could be much larger than the nominal level. The testing program described in this report was conducted to understand the consequence of operating the TSCR system at elevated solids loadings up to the high-solids limit of 15,000 ppm [i.e., 1.5-wt%] identified in the TSCR design basis. Although the system is not required to make throughput above the nominal solids loading, the testing was intended to provide important information related to potential off normal operations. At off normal levels near the high-solids limit, there are potential implications for TSCR performance in the areas of throughput, DEF pressure drop, filter backflush frequency, and IX column pressure drop. In addition, intrusion of solids into the IX column was postulated to impact the Cs-137 loading behavior by promoting channeling or flow maldistribution in the column; since the magnitude of the postulated effect was unknown, assessing it was also of interest. The testing was performed using representative waste simulants and a prototypic, integrated TSCR system designed and assembled specifically to conduct the high solids performance assessment. Overall, the scaled TSCR testing demonstrated that full-scale unit operations can succeed in fulfilling their processing objectives in the presence of solids up to 3,000 ppm, but there are potential performance challenges to filtration operations at solids loadings as low as ~500 ppm. The severity of the challenge is likely to be dependent on the type and size distribution of solids, of which the current testing only examined a single type and size distribution. To provide some flexibility for future full-scale operations, the results of the testing suggest two possible risk reduction strategies that can be implemented without any changes in TSCR design or configuration. One option would be to enact an administrative limit on the solids loading to protect TSCR from feeds that are likely to require a high DEF swap frequency. Another option is to permit operation of the DEFs at differential pressures greater than 2 psid before swapping filters. The selection of a higher differential pressure target is not anticipated to adversely impact DEF backflushing efficacy and would reduce both swap frequency and the amount of waste sent to AP-108.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Flow and pressure estimators in a waste heat recovery system

An apparatus includes a pump circuit structured to receive pump data indicative of an operating characteristic of a pump feeding a fluid to a waste heat recovery (WHR) system; a flow circuit structured to receive valve position data indicative of a position of a valve downstream of the pump, estimate a flow rate of the fluid exiting the pump, and estimate the flow rate of the fluid exiting the valve; and a pressure circuit structured to receive pressure data indicative of the pressure of the fluid exiting the valve, estimate a change in pressure of the fluid across the WHR system, and determine a pressure of the fluid in a hot section of the WHR system based on the pressure of the fluid exiting the valve and the change in the pressure of the fluid across the WHR system.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Transfer and Flushing Evaluation for Potential Precipitated Solids in the 241-AP-106 to EMF Transfer Pipeline for DFLAW

Waste transfer pipeline flushing is necessary to maintain pipeline performance, but added flush fluid increases the nuclear waste inventory. During the Direct Feed Low-Activity Waste (DFLAW) mission, waste transfer lines from the Interim Low-Activity Waste Storage Tank (i.e., 241-AP-106) to the Hanford Waste Treatment and Immobilization Plant (WTP) Low-Activity Waste (LAW) Facility must have the capability of being flushed to prevent accumulation of solids and to mitigate corrosion concerns. Operational experience at Hanford has shown that the solids precipitation occurs during processing operations from dilute Hanford liquids. Pacific Northwest National Laboratory was requested to evaluate the potential precipitated solid particle transport and flushing operational capabilities of the AP-106 through the Effluent Management Facility (EMF) low-point drain LAW feed pipeline. The evaluation results do not provide operational requirements, but rather provide a scoping basis for understanding the potential operational significance of solids precipitation in the pipeline. The salt and aluminum phase solids most likely to precipitate from the LAW feeds during cooling, evaporation, or mixing have particle densities that are estimated to range from 1.62 to 2.78 g/mL and a spherical particle size range of 8 to 2100 μm, depending on the solid phase considered. Application of the method to calculate the critical deposition velocity required by TFC-ENG-STD-26 at conservatively bounding estimates for the solids concentrations demonstrates that potentially precipitated solids may deposit on the bottom of the transfer pipe invert at the lower LAW feed pipeline flow rate, but the upper LAW feed pipeline flow rate will likely prevent deposition. The system pressure limit for the AP-106 through the EMF low-point drain LAW feed pipeline likely exceeds any pressure loss at a calculated critical deposition velocity even for the most adverse potential precipitated solid. However, should solids settle as a result of no-flow conditions, the flow capabilities of the AP-106 through the EMF low-point drain LAW feed pipeline are shown, based on the available literature, to be potentially inadequate for effective flushing operations to remove solids, even at solids concentrations below the maximum specified for LAW feed. Thus, stepwise solids accumulations over multiple transfers may be an issue, and eventual line plugging may occur. Further inadequacies may potentially be realized should the cohesive nature of certain precipitates be accounted for.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Simons Observatory: characterizing the Large Aperture Telescope Receiver with radio holography

Here, we present near-field radio holography measurements of the Simons Observatory Large Aperture Telescope Receiver optics. These measurements demonstrate that radio holography of complex millimeter-wave optical systems comprising cryogenic lenses, filters, and feed horns can provide detailed characterization of wave propagation before deployment. We used the measured amplitude and phase, at 4 K, of the receiver near-field beam pattern to predict two key performance parameters: 1) the amount of scattered light that will spill past the telescope to 300 K and 2) the beam pattern expected from the receiver when fielded on the telescope. These cryogenic measurements informed the removal of a filter, which led to improved optical efficiency and reduced sidelobes at the exit of the receiver. Holography measurements of this system suggest that the spilled power past the telescope mirrors will be less than 1%, and the main beam with its near sidelobes are consistent with the nominal telescope design. This is the first time such parameters have been confirmed in the lab prior to deployment of a new receiver. This approach is broadly applicable to millimeter and submillimeter instruments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Engineering Study of Svante’s Solid Sorbent Post-Combustion CO 2 Capture Technology at a Linde Steam Methane Reforming H 2 Plant

An initial engineering design study was performed for an advanced post combustion CO 2 capture (PCC) technology to be installed at a commercial-scale steam methane reforming (SMR) hydrogen plant located in the US Gulf Coast. The PCC process integrated the VeloxoTherm™ structured adsorbent technology from Svante for the CO 2 separation and CO 2 compression and purification and balance of plant systems provided by Linde. This pre-FEED equivalent study included following: (1) design basis, (2) basic engineering, including development of process flow diagrams and heat & material balances, (3) inside the battery limit (ISBL) equipment and systems specification, (4) balance of plant outside the battery limit (OSBL) equipment and systems specifications, (5) technology maturation plan, (6) hazard identification (HAZID) review, (7) environmental, health and safety (EH&S) assessment and environmental permitting analysis, (8) constructability review, (9) ISBL and OSBL EPC cost estimation, and (10) commercial-scale techno-economic analysis including capital expenditures (CAPEX) and operating expenditures (OPEX) and CO 2 capture cost estimates.

03 NATURAL GAS↗

Development of an autothermal formate-based hydrogen generator: From optimization of formate dehydrogenation conditions to thermal integration with Fuel Cells

Formate received significant attention for storing H2 in chemical bonds using the concept of H2 carriers. In this report, hydrogen generation from formate was optimized systematically by varying reaction variables. Initial mass activity with a turnover frequency of 3200 molH2 molPd–1 h–1 and 92% H2 yield were obtained in sodium formate (7 M 2.0 mL) dehydrogenation over Pd(3 wt %)/C at 80 °C. Influence of formate cations (Na, K, and NH4) on dehydrogenation was also elucidated, presenting that the fastest initial reaction kinetics was achieved with ammonium formate, whereas the highest H2 yield was obtained with potassium formate (PF) in multiple catalyst recycle tests. Finally, an on-site power generation system was integrated, where a proton exchange membrane fuel cell (PEMFC) was operated in conjunction with H2 produced from the custom developed semibatch dehydrogenation reactors. The system operation was demonstrated with continuous feeding of PF to generate H2 and power on demand without an external heat source by utilizing waste heat produced from the PEMFC in a highly efficient manner.

formate dehydrogenation, optimization of reaction ↗

Ethylene yield in oxidative dehydrogenation of ethane and ethane containing hydrocarbon mixtures

Methods and systems are provided for oxidative dehydrogenation of a hydrocarbon feed stream to produce a product stream with improved ethylene yield. The methods can include the steps of (i) combining a recycle stream with the feed stream to form a reactor feed stream, (ii) contacting the reactor feed stream with an oxide-based redox catalyst to produce the product stream comprising ethylene and one or more byproducts selected from the group consisting of methane, ethane, other byproducts, and mixtures thereof, and (iii) removing all or a part of the methane and ethane from the product stream to produce the recycle stream. Systems for the oxidative dehydrogenation (ODH) of a hydrocarbon feed stream are also provided to produce a product stream with improved ethylene yield. The systems and methods can include an oxide-based redox catalyst, such as Mg6MnO8, Cu6PbO8, and Ni6MnO8.

03 NATURAL GAS↗

Compositional Variation Tests on DuraMelter 100 with LAW Sub-Envelope C1 Feed (LAWC22 Glass) in Support of the LAW Pilot Melter (Final Report)

This report provides the results from tests that were performed on a DM100 system with LAW Sub-Envelope Cl and Al feeds in support of the subsequent Pilot Melter tests. The principal objectives of the DM100 tests were to determine the processing characteristics as the simulated melter feed transitioned from the LAW Sub-Envelope Cl to the Sub-Envelope Al composition and to determine the effect of bubbling rate on production rate.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Front-End Engineering and Design: Project Tundra Carbon Capture System (Final Report)

As the next phase of Project Tundra, Minnkota Power Cooperative (MPC) completed a front-end engineering and design (FEED) study to install a post-combustion CO 2 capture system (CCS) at the MPC operated (Square Butte Electric Cooperative-owned) Milton R. Young Station (MRYS) Unit 2 (MRY2), a 477-MW power plant fueled by North Dakota lignite. The project team completed the FEED with Fluor’s Econamine FG Plus℠ (EFG+) technology and is taking the next steps leading up to start of construction. Team members included FEED technical lead Fluor Enterprises (Fluor); owner’s engineer and balance of plant (BOP) engineer Burns & McDonnell (BMcD); leading carbon capture consultants (David Greeson Consulting, Hunt International Energy Services); environmental consultants (AECOM, Agora Environmental), other BOP engineering consultants (Golder Associates, Nels); cost-share funding agency, the North Dakota Industrial Commission (NDIC); and the Energy & Environmental Research Center (EERC). Project Tundra’s goal is to implement carbon capture, utilization, and storage (CCUS) in North Dakota, while preserving the use of lignite. Future options could lead to revitalizing legacy oil fields and creating a new CO 2 enhanced oil recovery (EOR) industry. The topic of this report is the FEED study for the carbon dioxide capture portion of Project Tundra. Building on the findings of a pre-FEED study for MRY2, the key deliverables contained in this FEED study are: a) design, costing, and performance data needed to commence project financing activities; b) engineering and material balances required to file for all project permits; and c) a final project schedule. Based on the results of the previous pre-FEED study, MPC and its team evaluated two options to provide the large amount of steam needed to operate the CCS: 1) installation of new natural gas package boilers and a new pipeline to supply natural gas to the facility and 2) extraction of steam from the existing MRYS steam turbine generator. The FEED study was performed using the package boilers option, as it was deemed to have the lowest technical risk, overall cost, and cost uncertainty. A key feature of the design, however, was the mixing the natural gas boilers’ flue gas with the MRY2 flue gas. This increased the size of the CCS system. This design also enabled the tie-in of Unit 1 flue gas for times when Unit 2 is offline. The CCS was designed to capture a combined 12,978 short tons per day (STPD) of CO 2 from the flue gases produced by the existing MRY Unit 2 along with flue gas produced by the new boiler package within the CCS. The 12,978 STPD CO 2 capture is achieved by normally processing 100% of the total available MRY Unit 2 flue gas (considering full load operation) and 100% of the boiler package flue gas, then removing 90% of the CO 2 available from the processed flue gas streams.

01 COAL, LIGNITE, AND PEAT↗

Electrically Insulated Catalyst–Ionomer Anode Interfaces toward Durable Alkaline Membrane Electrolyzers

Anion-exchange-membrane water electrolysis (AEMWE) is an emerging technology for scalable hydrogen production. AEMWE has poor durability when operating without supporting electrolyte due to the oxidation of ionomers and membranes in contact with the anode oxygen evolution reaction (OER) catalyst. We report a new “passivated” anode architecture for AEMWE where the OER catalysts and ionomers are physically separated with a thin film amorphous oxide coating that is electrically insulating but conductive to hydroxide ions. We find that 2–3 nm of HfO x passivation layers show sufficient hydroxide ion transport to minimally limit the cell performance while suppressing ionomer degradation with both Ir (500 mA·cm –2 for 40 h) and CoO x (1.0 A·cm –2 for 100 h) model porous-transport-layer-supported catalysts in AEMWE. As a result, this interfacial engineering approach guides electrode design to improve the durability of AEMWE, particularly for systems operating with pure-water feed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Simulation of PV Variability as a Function of PV Generation and Plant Size

The deployment of photovoltaic (PV) systems continues to show significant expansion; however, this growth has brought added attention to issues around the variability of the solar resource. Both spatial and temporal variability exist. Temporal scales can range from the sub-second to multiyear, whereas spatial scales can range from a few meters to tens of kilometers. There are multiple methods described in the literature to quantify PV variability at various spatial and temporal scales. This study focuses on short-term temporal variability and uses similar approaches with the addition of PV plant size a parameter to quantify variability. The method employed here incorporates the normalization of clear-and cloudy-sky conditions and PV plant size to quantify nominal variability metrics. The distribution and fluctuations of these metrics provide relevant information that is useful for system operations. The National Solar Radiation Database (NSRDB) is used to simulate PV variability as a function of PV generation and plant size. Hypothetical but realistic system information at 33 locations is used to model PV generation by feeding NSRDB solar irradiance data to the National Renewable Energy Laboratory’s System Advisor Model (SAM). Over the selected region, it is found that the aggregated ramp rates for the 1-minute data are associated with standard deviations ranging from 0.002–0.055 on a daily basis; however, hourly intervals induce higher aggregated ramp rates than the other timescales. Even though minute-to-minute variations are significant for the 1-minute time-scale, the standard deviation aggregated into a daily metric is smaller because of the cancellation of values.

irradiance↗

Fibrous anisotropy and mineral gradients within the radula stylus of chiton: Controlled stiffness and damage tolerance in a flexible biological composite

Over hundreds of millions of years, organisms have evolved architected structures via precise control over hierarchically assembled components, including the integration of dissimilar materials. One such example is found in the radula system of chitons, intertidal mollusks that feed on algae growing on the rock. Their radula consists of multiple rows of ultrahard teeth, each integrated with a foldable belt-like substrate via a stiff, yet flexible stylus, which is essential for efficient rasping during the feeding process. Here, we investigate the nano and micro-scale components and architectures as well as regional mechanical properties of the stylus, and their subsequent role during the rasping of Cryptochiton stelleri. Three important factors were determined to contribute to the regio-specific stiffness of the stylus: the presence of mineral components, highly oriented chitinous fibers, and a chemically cross-linked protein matrix. All these factors are varied throughout the stylus. There is a high mineral content on the trailing edge close to the tooth and a cross-linked matrix on the leading edge, both with orientational specific oriented chitin fibers that provide force transduction to the tooth. Conversely, there is a significant lack of mineral or cross-linked matrix in the proximal end as well as a low degree of fiber orientation, resulting in a flexible region that can accommodate torsion and flexure during rasping. Understanding the graded composite structure of the stylus and applying this unique design to various engineering fields such as soft robotics, biotechnology, and the medical industry, can inspire the production of high-performance materials.

Lee, Jung-Eun↗

Energy-Storing Cryogenic Carbon Capture™ for Utility and Industrial-scale Processes (Final Report)

This project leverages work completed under funding from previous U.S. Department of Energy (DOE) projects and other sources of funding around the Cryogenic Carbon Capture Process™ (CCC). The purpose of this project is to further develop a perturbation of the CCC process that stores energy called the Cryogenic Carbon Capture™ Energy Storing (CCC-ES) process. The successful completion of the tasks in this project has prepared the CCC-ES process for scaling and developed initial plans and a feasibility analysis for an engineering-scale or small-commercial scale system that can store at least 10 MWh of energy. The specific areas of work in this project are: (1) Develop a conceptual, site-specific integrated process flow diagram: Sustainable Energy Solutions (SES) developed a conceptual, site-specific plan including a process flow diagram for integrating CCC-ES at a specific location. The proposed system was based on a typical engineering-scale CCC system designed to capture 30-50 metric tonnes of CO 2 per day (TPD), with modifications and additional changes and equipment put in place to add the energy storage element to the system. The 30-50 TPD scale corresponds to the required 10 MWh of stored energy. This task includes updating simulation software for transient analysis. SES also coordinated with the Jim Bridger Power Plant in Point of Rocks, Wyoming to get site-specific data. Using these data, SES completed site-specific preliminary process flow diagrams, estimated capital and operating costs for the CCC-ES system, and used the upgraded software package to estimate the primary figures of merit. (2) Complete a technoeconomic analysis (TEA): SES completed a full-scale TEA of the CCC-ES system to meet specific success criteria. This TEA used process information from the host site selected above. (3) Technology and data gap assessment for the CCC-ES process: As part of the technology gap assessment, SES performed an assessment of the best alternative energy storage solutions including figures of merit and operational strengths and weaknesses. SES then compared the proposed system with a discussion of how it addresses the weaknesses of alternative systems, showing for example a cost of stored energy at less than $50/MWh and with a roundtrip efficiency of greater than 95%. This assessment includes technical and other risk analyses and technology gaps with research and development needs to commercialize the process by 2030. Finally, work includes a commercialization roadmap/development pathway outlining the major milestones to move to a commercially operating CCC-ES system. (4) Phase II pre-FEED project plan: SES completed a project plan for the Phase II pre-FEED analysis using the same host site as in the Phase I conceptual study.

03 NATURAL GAS↗

Simulation of PV Variability as a Function of PV Generation and Plant Size: Preprint

The deployment of photovoltaic (PV) systems continues to show significant expansion; however, this growth has brought added attention to issues around the variability of the solar resource. Both spatial and temporal variability exist. Temporal scales can range from the sub-second to multiyear, whereas spatial scales can range from a few meters to tens of kilometers. There are multiple methods described in the literature to quantify PV variability at various spatial and temporal scales. This study focuses on short-term temporal variability and uses similar approaches with the addition of PV plant size a parameter to quantify variability. The method employed here incorporates the normalization of clear- and cloudy-sky conditions and PV plant size to quantify nominal variability metrics. The distribution and fluctuations of these metrics provide relevant information that is useful for system operations. The National Solar Radiation Database (NSRDB) is used to simulate PV variability as a function of PV generation and plant size. Hypothetical but realistic system information at 33 locations is used to model PV generation by feeding NSRDB solar irradiance data to the National Renewable Energy Laboratory’s System Advisor Model (SAM). Over the selected region, it is found that the aggregated ramp rates for the 1-minute data are associated with standard deviations ranging from 0.002–0.055 on a daily basis; however, hourly intervals induce higher aggregated ramp rates than the other timescales. Even though minute-to-minute variations are significant for the 1-minute timescale, the standard deviation aggregated into a daily metric is smaller because of the cancellation of values.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Coolant delivery via an independent cooling circuit

An embodiment of an independent cooling circuit for selectively delivering cooling fluid to a component of a gas turbine system includes: at least one coolant feed channel fluidly coupled to a supply of cooling fluid; and an interconnected circuit of cooling channels, including: an interconnected circuit of cooling channels embedded within an exterior wall of the component; an impingement plate; and a plurality of feed tubes connecting the impingement plate to the exterior wall of the component and fluidly coupling a supply of cooling fluid to the interconnected circuit of cooling channels; wherein the cooling fluid flows through the plurality of feed tubes into the interconnected circuit of cooling channels only in response to a formation of a breach in the exterior wall of the component that exposes at least one of the cooling channels.

42 ENGINEERING↗