Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Enthalpy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Calibration of the Langley 8-Foot High Temperature Tunnel for Hypersonic Airbreathing Propulsion Testing

The NASA Langley 8-Foot High Temperature Tunnel has recently been modified to produce a unique testing capability for hypersonic airbreathing propulsion systems. Prior to these modifications, the facility was used primarily for aerothermal loads and structural verification testing at true flight total enthalpy conditions for Mach numbers between 6 and 7. One of the recent modifications was an oxygen replenishment system which allows operating airbreathing propulsion systems to be tested at true flight total enthalpies. Following the modifications to the facility, calibration runs were performed at total enthalpies corresponding to flight Mach numbers of 6.3 and 6.8 to establish the flow characteristics of the facility with its new capabilities. The results of this calibration, as well as modifications to tunnel combustor hardware prior to calibration to improve tunnel flow quality, are described in this paper.

Huebner, Lawrence D.↗

An Investigation of the Icing and Heated-air De-icing Characteristics of the R-2600-13 Induction System

A laboratory investigation was made on a Holley 1685-HB carburetor mounted on an R-2600-13 supercharger assembly to determine the icing characteristics and the heated-air de-icing requirements of this portion of the B-25D airplane induction system. Icing has been found to be most prevalent at relatively small throttle openings and, consequently, all runs were made at simulated 60-percent normal rated power condition. Icing characteristics were determined during a series of 15-minute runs over a range of inlet-air conditions. For the de-icing investigation severe impact ice was allowed to form in the induction system and the time required for the recovery of 95 percent of the maximum possible air flow at the original throttle setting was then determined for a range of wet-bulb temperatures. Results of these runs showed that ice on the walls of the carburetor adapter and on the rim of the impeller-shroud portion of the supercharger diffuser plate did not affect engine operation at 60-percent normal rated power. Ice that adversely affected the air flow and the fuel-air ratio was formed only on the central web of the carburetor and then only when the inlet air was saturated or contained free moisture in excess of saturation. No serious ice formations were observed at inlet-air temperatures above 66 0 F or with an inlet-air enthalpy greater than 34 Btu per pound. The maximum temperature at. which any trace of icing could be detected was 1110 F with a relative humidity of approximately 28 percent, The air-flow recovery time for emergency de-icing was 0.3 minute for.an enthalpy of 35 Btu per pound or wet-bulb temperature of 68 0 F. Further increase in enthalpy and wet-bulb temperature above these values resulted in very slight improvement in recovery time. The fuel-air ratio restored by a 5-Minute application of heated air was approximately 7 percent less than the initial value for cold-air conditions.

Chapman, Gilbert E.↗

Emission Spectroscopic Measurements in the Plenum Region of the NASA IHF Arc Jet Facility

A newly designed segment with optical access was installed in the plenum chamber of the 60 MW Interaction Heating arcjet Facility at NASA Ames Research Center. This special segment has ports located off axis, and the optical fibers can be inserted into these ports. The special segment allows for optical examination of the arc-heated flow as it enters the plenum, and thus assists in determining estimates of the thermodynamic state of the inflow to the convergent section of the nozzle. In the present work, optical emission measurements have been made in VIS-NIR region (wavelengths between 500 nm to 900 nm) for two settings of the arc heater - a 6000 A condition (high condition) with the minimum amount of radial injection of cold air in the plenum, and a 3300 A condition (low condition) with significant amount of cold air injection to reduce the enthalpy of the arc-heated stream. The results presented here were obtained using an Acton SP300i spectrometer coupled to a Princeton Instruments PI-max intensified camera. In addition to the optical emission measurements, computations were performed for the flow in the plenum and radiation along lines of sight corresponding to the optical ports. Along the centerline, i.e., the longest line of sight across the plenum cross-section, there is good agreement between computations and measurements for the high enthalpy condition, although the off-axis radial profiles show some differences. For the low enthalpy condition, there are significant differences between computations and measurements. The current working hypothesis is that the computational model does not capture details of the mixing process in the plenum.

Winter, Michael W.↗

Nitric Oxide PLIF Measurements in the Hypersonic Materials Environmental Test System (HYMETS)

A nonintrusive laser-based measurement system has been applied for the first time in the HYMETS (Hypersonic Materials Environmental Test System) 400 kW arc-heated wind tunnel at NASA Langley Research Center. Planar laser-induced fluorescence of naturally occurring nitric oxide (NO) has been used to obtain instantaneous flow visualization images, and to make both radial and axial velocity measurements. Results are presented at selected facility run conditions, including some in simulated Earth atmosphere (75% nitrogen, 20% oxygen, 5% argon) and others in simulated Martian atmosphere (71% carbon dioxide, 24% nitrogen, 5% argon), for bulk enthalpies ranging from 6.5 MJ/kg to 18.4 MJ/kg. Flow visualization images reveal the presence of large scale unsteady flow structures, and indicate nitric oxide fluorescence signal over more than 70% of the core flow for bulk enthalpies below about 11 MJ/kg, but over less than 10% of the core flow for bulk enthalpies above about 16 MJ/kg. Axial velocimetry was performed using molecular tagging velocimetry (MTV). Axial velocities of about 3 km/s were measured along the centerline. Radial velocimetry was performed by scanning the wavelength of the narrowband laser and analyzing the resulting Doppler shift. Radial velocities of 0.5km/s were measured.

Inman, Jennifer A.↗

Ionic Liquids to Replace Hydrazine

A method for developing safe, easy-to-handle propellants has been developed based upon ionic liquids (ILs) or their eutectic mixtures. An IL is a binary combination of a typically organic cation and anion, which generally produces an ionic salt with a melting point below 100 deg C. Many ILs have melting points near, or even below, room temperature (room temperature ionic liquids, RTILs). More importantly, a number of ILs have a positive enthalpy of formation. This means the thermal energy released during decomposition reactions makes energetic ILs ideal for use as propellants. In this specific work, to date, a baseline set of energetic ILs has been identified, synthesized, and characterized. Many of the ILs in this set have excellent performance potential in their own right. In all, ten ILs were characterized for their enthalpy of formation, density, melting point, glass transition point (if applicable), and decomposition temperature. Enthalpy of formation was measured using a microcalorimeter designed specifically to test milligram amounts of energetic materials. Of the ten ILs characterized, five offer higher Isp performance than hydrazine, ranging between 10 and 113 seconds higher than the state-of-the-art propellant. To achieve this level of performance, the energetic cations 4- amino-l,2,4-triazolium and 3-amino-1,2,4-triazolium were paired with various anions in the nitrate, dicyanamide, chloride, and 3-nitro-l,2,4-triazole families. Protonation, alkylation, and butylation synthesis routes were used for creation of the different salts.

Koelfgen, Syri↗

The Vaporization of B2O3(l) to B2O3(g) and B2O2(g)

The vaporization of B2O3 in a reducing environment leads to formation of both B2O3(g) and B2O2(g). While formation of B2O3(g) is well understood, many questions about the formation of B2O2(g) remain. Previous studies using B(s) + B2O3(l) have led to inconsistent thermodynamic data. In this study, it was found that after heating, B(s) and B2O3(l) appear to separate and variations in contact area likely led to the inconsistent vapor pressures of B2O2(g). To circumvent this problem, an activity of boron is fixed with a two-phase mixture of FeB and Fe2B. Both second and third law enthalpies of formation were measured for B2O2(g) and B2O3(g). From these the enthalpies of formation at 298.15 K are calculated to be -479.9 +/- 41.5 kJ/mol for B2O2(g) and -833.4 +/- 13.1 kJ/mol for B2O3(g). Ab initio calculations to determine the enthalpies of formation of B2O2(g) and B2O3(g) were conducted using the W1BD composite method and show good agreement with the experimental values.

Jacobson, Nathan S.↗

An Empirical Temperature Variance Source Model in Heated Jets

An acoustic analogy approach is implemented that models the sources of jet noise in heated jets. The equivalent sources of turbulent mixing noise are recognized as the differences between the fluctuating and Favre-averaged Reynolds stresses and enthalpy fluxes. While in a conventional acoustic analogy only Reynolds stress components are scrutinized for their noise generation properties, it is now accepted that a comprehensive source model should include the additional entropy source term. Following Goldstein s generalized acoustic analogy, the set of Euler equations are divided into two sets of equations that govern a non-radiating base flow plus its residual components. When the base flow is considered as a locally parallel mean flow, the residual equations may be rearranged to form an inhomogeneous third-order wave equation. A general solution is written subsequently using a Green s function method while all non-linear terms are treated as the equivalent sources of aerodynamic sound and are modeled accordingly. In a previous study, a specialized Reynolds-averaged Navier-Stokes (RANS) solver was implemented to compute the variance of thermal fluctuations that determine the enthalpy flux source strength. The main objective here is to present an empirical model capable of providing a reasonable estimate of the stagnation temperature variance in a jet. Such a model is parameterized as a function of the mean stagnation temperature gradient in the jet, and is evaluated using commonly available RANS solvers. The ensuing thermal source distribution is compared with measurements as well as computational result from a dedicated RANS solver that employs an enthalpy variance and dissipation rate model. Turbulent mixing noise predictions are presented for a wide range of jet temperature ratios from 1.0 to 3.20.

Khavaran, Abbas↗

Methodology for Flight Relevant Arc-Jet Testing of Flexible Thermal Protection Systems

A methodology to correlate flight aeroheating environments to the arc-jet environment is presented. For a desired hot-wall flight heating rate, the methodology provides the arcjet bulk enthalpy for the corresponding cold-wall heating rate. A series of analyses were conducted to examine the effects of the test sample model holder geometry to the overall performance of the test sample. The analyses were compared with arc-jet test samples and challenges and issues are presented. The transient flight environment was calculated for the Hypersonic Inflatable Aerodynamic Decelerator (HIAD) Earth Atmospheric Reentry Test (HEART) vehicle, which is a planned demonstration vehicle using a large inflatable, flexible thermal protection system to reenter the Earth's atmosphere from the International Space Station. A series of correlations were developed to define the relevant arc-jet test environment to properly approximate the HEART flight environment. The computed arcjet environments were compared with the measured arc-jet values to define the uncertainty of the correlated environment. The results show that for a given flight surface heat flux and a fully-catalytic TPS, the flight relevant arc-jet heat flux increases with the arc-jet bulk enthalpy while for a non-catalytic TPS the arc-jet heat flux decreases with the bulk enthalpy.

Mazaheri, Alireza↗

Nitric Oxide PLIF Measurements in the Hypersonic Materials Environmental Test System (HYMETS)

Planar laser-induced fluorescence (PLIF) of naturally occurring nitric oxide (NO) has been used to obtain instantaneous flow visualization images, and to make both radial and axial velocity measurements in the HYMETS (Hypersonic Materials Environmental Test System) 400 kW arc-heated wind tunnel at NASA Langley Research Center. This represents the first application of NO PLIF flow visualization in HYMETS. Results are presented at selected facility run conditions, including some in a simulated Earth atmosphere (75% nitrogen, 20% oxygen, 5% argon) and others in a simulated Martian atmosphere (71% carbon dioxide, 24% nitrogen, 5% argon), for specific bulk enthalpies ranging from 6.5 MJ/kg to 18.4 MJ/kg. Flow visualization images reveal the presence of large scale unsteady flow structures, and indicate nitric oxide fluorescence signal over more than 70% of the core flow for specific bulk enthalpies below about 11 MJ/kg, but over less than 10% of the core flow for specific bulk enthalpies above about 16 MJ/kg. Axial velocimetry was performed using molecular tagging velocimetry (MTV). Axial velocities of about 3 km/s were measured along the centerline. Radial velocimetry was performed by scanning the wavelength of the narrowband laser and analyzing the resulting Doppler shift. Radial velocities of +/- 0.5 km/s were measured.

Inman, Jennifer A.↗

A Technique for Determining the Nozzle-Flow Properties of Air in an Equilibrium, Nonequilibrium, or Frozen State

One of the problems associated with the development of high-enthalpy hypersonic test facilities hos been the determination of nozzle flow properties. This note presents a technique for determining the flow properties of air in an equilibrium, non-equilibrium, or frozen state using two test section measurements. A knowledge of two stagnation properties is required before the technique can be applied. The stagnation pressure can be measured, and reference 1 offers a method for determining stagnation enthalpy. Results of the calculations using the method of reference 1 are presented in reference 2 in a chart (chart 21) which can be readily used to determine the stagnation enthalpy from measurements of stagnation pressure, mass flow of air through the tunnel, and throat diameter.

Hayman, Lovick O.↗

Characterization of Freestream Disturbances in Conventional Hypersonic Wind Tunnels

While low disturbance ("quiet") hypersonic wind tunnels are believed to provide more reliable extrapolation of boundary layer transition behavior from ground to flight, the presently available quiet facilities are limited to Mach 6, moderate Reynolds numbers, low freestream enthalpy, and subscale models. As a result, only conventional ("noisy") wind tunnels can reproduce both Reynolds numbers and enthalpies of hypersonic flight configurations, and must therefore be used for flight vehicle test and evaluation involving high Mach number, high enthalpy, and larger models. This article outlines the recent progress and achievements in the characterization of tunnel noise that have resulted from the coordinated effort within the AVT-240 specialists group on hypersonic boundary layer transition prediction. New Direct Numerical Simulation (DNS) datasets elucidate the physics of noise generation inside the turbulent nozzle wall boundary layer, characterize the spatiotemporal structure of the freestream noise, and account for the propagation and transfer of the freestream disturbances to a pitot-mounted sensor. The new experimental measurements cover a range of conventional wind tunnels with different sizes and Mach numbers from 6 to 14 and extend the database of freestream fluctuations within the spectral range of boundary layer instability waves over commonly tested models. Prospects for applying the computational and measurement datasets for developing mechanism-based transition prediction models are discussed.

Duan, Lian↗

Corrigendum to "Mass Spectrometric Measurements of the Silica Activity in the Yb2O3-SiO2 System and Implications to Assess the Degradation of Silicate-Based Coatings in Combustion Environments"

The authors regret that errors appeared in the above manuscript.The corrections that need to be made are highlighted in yellow in the thermodynamic cycle of Table 2. The enthalpies in reactions 2, 5 and 6 are negative. Now that the enthalpies in reactions 2, 5 and 6 are negative, the correct enthalpy of formation of Yb2SiO5 is 2774 11 kJ mol-1. Also, the correct element in the formula Y2SiO5 on the right side of equation 2 is Yb instead Y.

Costa, Gustavo↗

Calibration Probe Uncertainty and Validation for the Hypersonic Material Environmental Test System

This paper presents an uncertainty analysis of the stagnation-point calibration probe surface predictions for conditions that span the performance envelope of the Hypersonic Materials Environmental Test System facility located at NASA Langley Research Center. A second-order stochastic expansion was constructed over 47 uncertain parameters to evaluate the sensitivities, identify the most significant uncertain variables, and quantify the uncertainty in the stagnation-point heat flux and pressure predictions of the calibration probe for a low- and high-enthalpy test condition. A sensitivity analysis showed that measurement bias uncertainty is the most significant contributor to the stagnation-point pressure and heat flux variance for the low-enthalpy condition. For the high-enthalpy condition, a paradigm shift in sensitivities revealed the computational fluid dynamics model input uncertainty as the main contributor. A comparison between the prediction and measurement of the stagnation-point conditions under uncertainty showed that there was evidence of statistical disagreement. A validation metric was proposed and applied to the prediction uncertainty to account for the statistical disagreement when compared to the possible stagnation-point heat flux and pressure measurements.

Brune, Andrew J.↗

Comparison between Computational and Experimental Wall-Shear Stress and Pressure Measurements in a Supersonic Wind Tunnel

We study the performance of two selected RANS models (SST-$k$-$\omega$ and Baldwin-Lomax) to simulate the mean wall-shear and pressure data obtained from a distributed-roughness-related experimental campaign conducted at Ahmic Aerospace, LLC, located in Ohio, US. A structured compressible Navier-Stokes in-house solver, DPLR, is used to conduct the RANS simulations. As the final objective is to perform the studies under high-enthalpy flow conditions, such as inside the AHF facility at NASA-Ames Research Center (ARC), the current investigation focuses on the low-enthalpy cases using Ahmic's high-Reynolds-number supersonic wind tunnel as the initial step to simplify the flow physics. Furthermore, the wind tunnel simulations are conducted with perfectly-smooth walls to further simplify the problem and perform the initial testing of different solver-based RANS models. The Baldwin-Lomax model is observed to be more accurate than the SST model. However, when these RANS models and their roughness augmentation models are utilized to study their accuracy with respect to the experimental datasets, where the roughness effects are activated, both models perform well for a low roughness height case. However, as the roughness height increases, the SST model more accurately predicts the wall data (shear and pressure) than the Baldwin-Lomax model. Therefore, this present work has built a solid foundation for selecting the best RANS model to study the wall data under high-enthalpy flow conditions at the AHF facility soon.

Prakash Shrestha↗

Thermodynamic Properties of Nitrogen Including Liquid and Vapor Phases from 63K to 2000K with Pressures to 10,000 Bar

Tables of thermodynamic properties of nitrogen are presented for the liquid and vapor phases for temperatures from the freezing line to 2000K and pressures to 10,000 bar. The tables include values of density, internal energy, enthalpy, entropy, isochoric heat capacity, isobaric heat capacity velocity of sound, the isotherm derivative, and the isochor derivative. The thermodynamic property tables are based on an equation of state, P=P (p,T), which accurately represents liquid and gaseous nitrogen for the range of pressures and temperatures covered by the tables. Comparisons of property values calculated from the equation of state with measured values for P-p-T, heat capacity, enthalpy, latent heat, and velocity of sound are included to illustrate the agreement between the experimental data and the tables of properties presented here. The coefficients of the equation of state were determined by a weighted least squares fit to selected P-p-T data and, simultaneously, to isochoric heat capacity data determined by corresponding states analysis from oxygen data, and to data which define the phase equilibrium criteria for the saturated liquid and the saturated vapor. The vapor pressure equation, melting curve equation, and an equation to represent the ideal gas heat capacity are also presented. Estimates of the accuracy of the equation of state, the vapor pressure equation, and the ideal gas heat capacity equation are given. The equation of state, derivatives of the equation, and the integral functions for calculating derived thermodynamic properties are included.

Thermodynamic properties↗

Development and initial operating characteristics of the 20 megawatt linear plasma accelerator facility

A 20-megawatt linear plasma accelerator facility, a steady flow, Faraday-type plasma accelerator facility for high velocity aerodynamic testing, was constructed, developed, and brought to an operational status. The accelerator has a 63.5-mm-square and 0.5-meter-long channel and utilizes nitrogen-seeded with 2 % mole fraction of cesium vapor. Modification of the original accelerator design characteristics and the improvements necessary to make the arc heater a suitable plasma source are described. The measured accelerator electrode current distribution and the electrode-wall potential distributions are given. The computed and the measured values are in good agreement. Measured pitot pressure indicates that an accelerator exit velocity of 9.2 km/sec, is obtained with 30 of the 36 electrode pairs powered and corresponds to a velocity increase to about 2 1/4 times the computed entrance velocity. The computed stagnation enthalpy at the accelerator exit is 92 MJ/kg, and the mass density corresponds to an altitude of about 58 km. The 92 MJ/kg stagnation enthalpy corresponds to a kinetic energy content at low temperature equivalent to a velocity of 13.6 km/sec.

Carter, A. F.↗

Radiative cooling of shock-heated air in an explosively driven shock tube.

Results are presented of an experimental program to measure the effect of radiative cooling on the enthalpy distribution behind incident shock waves traveling in air. The shock velocity was nominally 16 km/sec and the preshock ambient pressure was varied from 0.4 to 1.6 torr. Shock-tube diameters of 4.7 and 9.4 cm were used to investigate the effects of varying optical depths. Radiative cooling rates were determined from spatially resolved measurements of the profile of the H sub alpha line and from absolute measurements of the continuum radiation. The measured enthalpy profiles are in good agreement with the theoretical predictions of Chien and Compton which account for both nongrey and multidimensional aspects of the radiative transport in the shock tube.

Cooper, D. M.↗

Analysis of flight test transition and turbulent heating data. Part 2: Turbulent heating results

The results of three turbulent heating predictions (Van Driest II, Spalding-Chi, and Walker Eckert reference enthalpy) have been compared to the data of several re-entry vehicles. Details and comparisons of each technique with the data are presented. The data analyzed cover a range of local Mach numbers of 3.3 to 15.2, wall to boundary layer edge temperature ratio of 0.46 to 2.6 and local Reynolds number of 7 times 10 to the 6th power to 5.3 times 10 to the 8th power. Data were transformed to an incompressible plane, using the prediction methods above, and compared with the Colburn and von Karman forms of the Reynolds analogy. The results indicate that the reference enthalpy technique best fits the data when the Colburn analogy was used; whereas, the Van Driest II method agrees with both forms of the Reynolds analogy. The Spalding-Chi method tends to under predict the data. Finally, there does not appear to be any significant difference when comparing the incompressible Stanton number as a function of Renolds number based on either wetted length or momentum thickness.

Laganelli, A. L.↗