Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Energy Consumption”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

A mathematical design framework for membrane pre-concentration in energy-efficient recovery of fermentation products

Due to the dilute nature of products manufactured via fermentation and cell-free bioprocessing, dewatering is a common unit operation in downstream processing (DSP) for bioproduct recovery, but it is typically energy intensive. To improve DSP energy efficiency for bio-based small molecules, integrating high-pressure membrane pre-concentration is a promising process option. However, this approach is typically constrained by a tradeoff between concentration factor (CF) and product recovery (PR), namely increasing the CF typically results in greater product loss, and vice versa. Here we developed a model that enables process design guidelines to: (i) identify scenarios in which the additional energy consumption and product loss from membrane pre-concentration are justified for use in DSP, and (ii) determine the optimal CF that minimizes process specific energy consumption. We compared the energy consumption of high-pressure membrane-integrated processes to evaporation-only processes and applied the model to an experimental case study for the separation and purification of butyric acid from Clostridium tyrobutyricum fermentation using an in situ product recovery (ISPR) process. The model estimated that integrating a tangential-flow reverse osmosis (RO) pre-concentration unit could reduce process energy consumption up to 45%. The use of advanced membrane pre-concentration technologies, such as negative rejection membranes and organic solvent reverse osmosis (OSRO), have the potential to further reduce the overall process specific energy consumption up to 96%, projected based on modeling. Overall, membrane pre-concentration, especially when strategically integrated prior to an evaporation step with optimized process conditions, holds significant potential for improving DSP energy efficiency, particularly in applications requiring substantial solvent removal for product recovery from dilute mixtures.

09 BIOMASS FUELS↗

Prevalence of typical operational problems and energy savings opportunities in U.S. commercial buildings

In the United States, as much as 30% of the 19 EJ that commercial buildings consume is considered excess. Much of the excess energy is due to the inability to manage building operations efficiently. Because almost 20% of the total primary energy consumption is associated with commercial buildings, significant energy reductions in this sector are needed to mitigate climate change. Therefore, many cities and states are mandating periodic “tune-ups” of these buildings to eliminate excess energy consumption. Although the benefits of tune-ups and retro-commissioning are clear, focusing these mandates to look for specific opportunities has been a challenge because of the lack of studies that document the prevalence of opportunities. Therefore, we analyzed building automation system data from 151 buildings across the United States to document common operational problems and opportunities to improve building operations. This analysis showed that opportunities to improve building operations exist in almost every building. These opportunities were not strongly correlated with building vintage or size, but were reflective of how the buildings are operated. The prevalence of the top 20 opportunities ranged between 74% and 23%, with 40% of these associated with air-handling units. The rest of the opportunities are associated with schedules, chilled and hot-water distribution, and zone controls. Of the 151 buildings, 69 of them implemented corrective actions of some or all opportunities that were identified. Implementation varied across the Re-tuning categories, with 60% for schedule opportunities, 50% for zone opportunities, over 40% for the air-handling unit and hot-water opportunities, and 35% of the chilled-water opportunities. There was wide variation in whole building energy savings, ranging from 0 to 50% and 0 to 18 $/m2 with median percent annual whole building savings of 12% and median normalized annual cost savings of $1.75/m2. In addition to documenting these key findings, the paper provides a list of opportunities that can be automatically and continuously identified and corrected and offers a list of those opportunities that should be the focus of the mandates.

Katipamula, Srinivas↗

Secure eco-routing with databases under homomorphic encryption

A method for generating energy-optimized travel routes for a motor vehicle includes one or more of the following: receiving an origin destination (OD) of the motor vehicle and an encrypted energy consumption database of the motor vehicle; generating N candidate routes for the OD; evaluating encrypted energy consumption over a route using an encrypted energy consumption database; applying at least one of homomorphic addition function or homomorphic multiplication function to the encrypted energy consumption data; and returning N candidate routes and their encrypted energy consumption to a client.

Hegde, Bharatkumar↗

Commercial Building Planning and Retrofitting Strategy for Grid Services

The increasing integration of distributed energy resources (DERs) plays an important role in improving energy consumption efficiency. In September 2020, the Federal Energy Regulatory Commission (FERC) approved Order 2222 which opens wholesale electricity markets to small capacity DERs. The benefit of this new FERC Order 2222 is that DERs, such as rooftop solar panels and batteries, will be able to participate in regional electricity markets and provide grid services. Meanwhile, the planning and operation strategies of DERs are facing new challenges to account for the impact of the wholesale market with numerous uncertainty factors. Therefore, in this paper, we propose a new planning and retrofitting model for long-term commercial buildings that considers both DER investment and market participation. Specifically, we explore the capability of implementing DERs for grid services. The effectiveness of the proposed model is validated using real-world data. Simulation results also validate that participating in grid services can significantly increase revenues through appropriate building energy management and shorten the payback period of DER investments.

building energy management↗

Prototype College Building Energy Model: Building Characteristics and Energy Simulation Results

The US Department of Energy supports the development of commercial building energy codes and standards. To support commercial building energy research activities and the development of commercial building energy codes and standards, continuous efforts have been made to convert 16 prototype building models, which cover 80% of US commercial building floor space, to OpenStudio prototype buildings. Additionally, the suite of prototype building models was expanded to include the addition of new building prototype models (e.g., courthouse, college building). Multiple sources, including databases, documented projects, and personal communications, were used to define the prototype college building, and a 4-story with 69,063 ft 2 building was considered as the prototype college building to represent an average-sized college building in the United States. To represent realistic occupancy schedules and increase the granularity of information, actual class reservation schedules were collected and used. This report documents the building and system characteristics of the prototype college building model combined with climate-specific and construction vintage–specific requirements for the building envelope and systems from ASHRAE Standard 90.1. The energy simulation results are presented for 4 construction vintages (2004, 2007, 2010, and 2013) and 15 ASHRAE climate zones. The site energy use intensity of the college building was compared with 2012 Commercial Building Energy Consumption Survey (CBECS) and ENERGY STAR data to verify the simulation results. The site energy use intensity of the college building ranged from 60 to 202.4 kBtu/ft 2 , and compared with the energy use intensities of Commercial Building Energy Consumption Survey (122.9 kBtu/ft 2 ) and ENERGY STAR (84.3 kBtu/ft 2 ) data, the prototype college building results are in a reasonable range.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Self-consumption for energy communities in Spain: A regional analysis under the new legal framework

European climate polices acknowledge the role that energy communities can play in the energy transition. Self-consumption installations shared among those living in the same building are a good example of such energy communities. In this work, a regional analysis of optimal self-consumption installations under the new legal framework recently passed in Spain is performed. Results show that the optimal sizing of the installation leads to economic savings for self-consumers in all the territory, for both options with and without remuneration for energy surplus. A sensitivity analysis on technology costs revealed that batteries still require noticeably cost reductions to be cost-effective in a behind the meter self-consumption environment. In addition, solar compensation mechanisms make batteries less attractive in a scenario of low PV costs, since feeding PV surplus into the grid, yet less efficient, becomes more cost-effective. Furthermore, an improvement for the energy surplus remuneration policy in the context of the current legislation was proposed and analysed. It consists in the inclusion of the economic value of the avoided power losses in the remuneration.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Geospatial Characterization of Low-Temperature Heating and Cooling Demand in the United States

Geothermal resources at temperatures below 150 degrees C have great potential as energy sources for various direct-use applications including heating and cooling in residential and commercial buildings. This study geospatially quantifies U.S. heating and cooling demand in residential, commercial, and manufacturing sectors; heating demand in the agricultural sector; and cooling demand in data centers at the county level through end-use energy consumption, expenditure, and commissioned power analyses. Heating and cooling demand in the residential sector was estimated using energy consumption data obtained from the U.S. Energy Information Administration accounting for different U.S. climate zones. For commercial sector analysis, the end-use major fuel energy intensity at the census division level was disaggregated to the county level with respect to principal building activities. Heating and cooling demand analysis for the manufacturing sector was based on end-use energy consumption for direct-use total process categorized by the North America Industry Classification System. Fuel expenditures in the U.S. Department of Agriculture Farm Production Expenditures were examined for heating demand analysis in the agricultural sector, particularly for the greenhouse, nursery, and floriculture production category. Lastly, commissioned power for data centers in the United States were explored for cooling demand analysis. Results indicated a significant fraction of U.S. primary energy consumption is used for low-temperature heating and cooling applications. Heating and cooling demand in residential and commercial sectors is significantly affected by the number of housing units and climate zone designations, while heating and cooling demand in manufacturing and agricultural sectors and data centers are mainly dependent on the number of facilities and their locations. Maps were generated visualizing where heating and cooling demand is high and, overlain with geothermal resource maps, can indicate locations where geothermal energy can supply this heating and cooling demand.

cooling demand↗

Chilled water temperature set-point reset based on outdoor air temperature and its cooling energy performance in an office building

Here, in this study, the cooling energy performance of two strategies for controlling ChWT (chilled water temperature) are compared: the conventional control strategy of constantly fixing ChWT and the OAT (outdoor air temperature) compensation control strategy that adjusts ChWT according to the changes in OAT. OAT compensation control strategy was modeled and realized based on Appendix G of ASHRAE Standard 90.1. It was confirmed that applying OAT compensation control strategy can significantly reduce chiller energy consumption, which accounts for the largest portion of total cooling energy consumption. It was found that the difference in total cooling energy consumption between applying the conventional control of constantly fixing ChWT to 6 °C and applying the OAT compensation control was approximately 8 % and 3 % during spring (March to May) and summer (June to August), respectively. Additionally, during the fall (September–November) period, about 7 % of total cooling energy consumption could be saved.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Study of Energy Saving Analysis for Different Industries

This study analyzes the energy consumption and saving performance in the industries in the U.S.A. All energy assessments implemented were for facilities whose annual energy consumptions were less than 9,000,000 kWh (small- and medium-sized industries) that belong to the manufacturing industries with Standard Industrial Classification (SIC) codes ranging from 2000 to 3999 in addition to SIC codes starting with 49. In this study, assessments are classified based on the SIC codes with recommendations analysis for each classification to get a better idea of what recommendations were suggested in each major industrial sector, knowing that 68 assessments were made, and their SIC ranged from 14 to 49. In addition, this study could be considered as a guide for energy engineers and other personnel involved in the energy assessment process. The information investigated can give a better prediction for composing better energy-demanding industries and minimizing energy consumption. More than 61 energy assessments were conducted for manufacturing facilities and analyzing the data gathered and processed. Through the research, the Fabricated Metal industry achieved the highest average kWh savings and cost savings within the industries studied in this study. According to the average gigajoule (GJ) savings, the fabricated metal industry ranked second within the studied industries. Conversely, Food and Kindred Products achieved the highest GJ energy savings within the studied industries. Overall, lighting, motors, compressors, and heating, ventilation, and air conditioning (HVAC) were the most contributing industries in a total of 547 recommendations.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Energy and Emission Prediction for Mixed-Vehicle Transit Fleets Using Multi-task and Inductive Transfer Learning

Public transit agencies are focused on making their fixed-line bus systems more energy efficient by introducing electric (EV) and hybrid (HV) vehicles to their fleets. However, because of the high upfront cost of these vehicles, most agencies are tasked with managing a mixed-fleet of internal combustion vehicles (ICEVs), EVs, and HVs. In managing mixed-fleets, agencies require accurate predictions of energy use for optimizing the assignment of vehicles to transit routes, scheduling charging, and ensuring that emission standards are met. The current state-of-the-art is to develop separate neural network models to predict energy consumption for each vehicle class. Although different vehicle classes’ energy consumption depends on a varied set of covariates, we hypothesize that there are broader generalizable patterns that govern energy consumption and emissions. In this paper, we seek to extract these patterns to aid learning to address two problems faced by transit agencies. First, in the case of a transit agency which operates many ICEVs, HVs, and EVs, we use multi-task learning (MTL) to improve accuracy of forecasting energy consumption. Second, in the case where there is a significant variation in vehicles in each category, we use inductive transfer learning (ITL) to improve predictive accuracy for vehicle class models with insufficient data. As this work is to be deployed by our partner agency, we also provide an online pipeline for joining the various sensor streams for fixed-line transit energy prediction. Here, we find that our approach outperforms vehicle-specific baselines in both the MTL and ITL settings.

97 MATHEMATICS AND COMPUTING↗

Geospatial Characterization of Low-Temperature Heating and Cooling Demand in the United States: Preprint

Geothermal resources at temperatures below 150 degrees C have great potential as energy sources for various direct-use applications including heating and cooling in residential and commercial buildings. This study geospatially quantifies U.S. heating and cooling demand in residential, commercial, and manufacturing sectors; heating demand in the agricultural sector; and cooling demand in data centers at the county level through end-use energy consumption, expenditure, and commissioned power analyses. Heating and cooling demand in the residential sector was estimated using energy consumption data obtained from the U.S. Energy Information Administration accounting for different U.S. climate zones. For commercial sector analysis, the end-use major fuel energy intensity at the census division level was disaggregated to the county level with respect to principal building activities. Heating and cooling demand analysis for the manufacturing sector was based on end-use energy consumption for direct-use total process categorized by the North America Industry Classification System. Fuel expenditures in the U.S. Department of Agriculture Farm Production Expenditures were examined for heating demand analysis in the agricultural sector, particularly for the greenhouse, nursery, and floriculture production category. Lastly, commissioned power for data centers in the United States were explored for cooling demand analysis. Results indicated a significant fraction of U.S. primary energy consumption is used for low-temperature heating and cooling applications. Heating and cooling demand in residential and commercial sectors is significantly affected by the number of housing units and climate zone designations, while heating and cooling demand in manufacturing and agricultural sectors and data centers are mainly dependent on the number of facilities and their locations. Maps were generated visualizing where heating and cooling demand is high and, overlain with geothermal resource maps, can indicate locations where geothermal energy can supply this heating and cooling demand.

cooling demand↗

Material Flow Analysis and Life Cycle Assessment of Polyethylene Terephthalate and Polyolefin Plastics Supply Chains in the United States

Plastics are useful and beneficial materials that contribute to an improved quality of life, yet they generate significant solid wastes and emissions and consume significant energy resources. Systems analysis is incomplete on current linear production systems of plastics supply chains and their associated processes. Our study combines material flow and life cycle assessment data sets of polyethylene terephthalate (PET) and the main polyolefin polymers in the United States, comprising over 70% of plastics flows. This study estimates the total greenhouse gas (GHG) emissions and energy consumption of these supply chains, including transportation and end-of-life processes, lacking in prior studies. Here we calculate annual GHG emissions and energy consumption of these plastic supply chains to be 101 MMT CO 2 -eq and 3248 PJ in 2019, respectively. The GHG emissions of these supply chains represented 1.5% of the total U.S. emissions and 5% of the total U.S. industry-related GHG emissions. The total energy consumption of these supply chains represented 3.1% of the total U.S. energy consumption in 2019. Transportation of PET and polyolefin plastic materials contributes 5% and 2% to the total supply chain GHG emissions and energy consumption, respectively. This baseline study provides a benchmark and enables a comparison to future circular production systems for plastics in the United States.

09 BIOMASS FUELS↗

Important powertrain dynamics for developing models for control of connected and automated electrified vehicles

Connected and Automated Vehicles (CAV) technology presents significant opportunities for energy saving in the transportation sector. CAV technology forecasts vehicle and powertrain power needs under various terrain, ambient, and traffic conditions. Integration of the CAV technology in Hybrid Electric Vehicles (HEVs) provides the opportunity for optimal vehicle operation. Indeed, Hybrid Electric Vehicle powertrains present high degrees of flexibility and possibility for choosing optimum powertrain modes based on the predicted traction power needs. In modeling complex CAV powertrain dynamics, the modeler needs to consider short-time scale powertrain dynamics, such as engine transients, and hysteresis of mode-switching for a multi-mode HEV. Therefore, the powertrain dynamics essential for developing powertrain controllers for a class of connected HEVs is presented. To this end, control-oriented powertrain dynamic models for a test vehicle consisting of full electric, hybrid, and conventional engine operating modes are developed. The resulting powertrain model can forecast vehicle traction torque and energy consumption for the specified prediction horizon of the test vehicle. The model considers different operating modes and associated energy penalty terms for mode switching. Thus, the vehicle controller can determine the optimum powertrain mode, torque, and speed for forecasted vehicle operation via utilizing connectivity data. The powertrain model is validated against the experimental data and shows prediction error of less than 5% for predicting vehicle energy consumption. The model is used to create energy penalty maps that can be used for CAV control, for example fuel penalty map for engine torque changes (10–40 Nm) at each engine speed. The results of model-based optimization show optimum switching delays ranging from 0.4 to 1.4 s to avoid hysteresis in mode switching.

Engineering↗

ScaleML: Machine Learning based Heap Memory Object Scaling Prediction

Memory subsystem contributes 28-40% of total energy consumption. Several studies investigated energy prediction and consumption via profiling memory object access patterns. However, such profiling leads to higher energy consumption due to intense memory object-level profiling to achieve high prediction accuracy. Further, memory object access pattern prediction has been considered through analyzing the variation between memory object access patterns, referred to as scaling rate. The existing techniques for scaling rate prediction, such as Linear Scaling Rate (LSR), suffer from a high error rate in prediction with changes in access patterns, which leads to a high error rate of energy consumption prediction. In this paper, we compare and evaluate several memory object access pattern prediction models including LSR and machine learning (ML) models. Further, we propose SCALEML, a heap memory object scaling rate prediction mechanism that employs an ML model to achieve high access pattern prediction accuracy with variations in memory object access patterns. We evaluate SCALEML using various application benchmarks. The experimental results show that SCALEML achieves about 20% higher accuracy than the LSR model for predicting the scaling rate of object access patterns and energy estimation.

Park, Joongeon↗

The current state of the industrial energy assessment and its impacts on the manufacturing industry

Energy-intensive manufacturing is the greatest contributor to the U.S. industrial energy consumption today. Globally, manufacturing facilities are being directed to reduce their energy consumption to prepare for a sustainable future. Industrial energy assessment plays a crucial role in helping facilities meet their energy efficiency goals by encouraging the implementation of cost-effective, energy-saving recommendations to the existing equipment and processes. Across the world, programs such as the U.S. Department of Energy (DOE) sponsored Industrial Assessment Centers (IACs) (operational across several states in the U.S. for over four decades), are transforming the future of industrial energy consumption by offering free industrial energy assessments to qualifying facilities. In this review paper, the industrial energy assessment approach and practices are comprehensively reviewed with focus on popular recommendations, procedures, and the current practices of the industrial energy assessment program. Specifically, opportunities for improvement in the most energy-intensive manufacturing processes are examined, concentrating on the energy savings and other non-energy benefits of each of these measures, such as cost savings and emissions reduction. Furthermore, this paper also reviews how these energy-saving opportunities are procedurally evaluated and how factors, such as level and cost of assessments, and assessment metrics, are currently defining industrial energy assessment. In final considerations, existing research on energy management, decarbonization through electrification, and renewable energy in industry is reviewed and discussed, and how these advancements will shape the future of industrial energy assessment is addressed through forward-looking lenses.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Analysis of the Financial Impacts of Building Performance Standard Penalties on Commercial Buildings in Aurora, Colorado

Buildings are responsible for 30% of total energy consumption worldwide. To address building energy, jurisdictions in the USA have enacted Building Performance Standards (BPS) legislation. The objective of BPS is to reduce energy consumption in buildings, thereby reducing the energy burden on utility infrastructure and other externalities. This is accomplished by setting mandatory energy use limits coupled with penalties for exceeding those limits. One of the key questions in BPS policymaking is how these penalties might impact the finances of building owners and tenants. This paper presents an analysis of BPS penalties in Aurora, Colorado, specifically targeting buildings impacted by the adopted statewide BPS legislation. Several BPS penalty structures were applied to the affected building stock in Aurora, and the potential impacts on building owner returns and tenant rents were estimated. The results show that for some combinations of building types and penalty structures, potential rent increases due to penalties could match or exceed typical yearly rent increases. The results also show that in most cases, for Aurora, there was no statistically significant difference in impact between buildings located in under-resourced and well-resourced areas.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Lawrence, Massachusetts, Residential Building Efficiency and Electrification Analysis [Slides]

As part of the Communities Local Energy Action Program (CLEAP), the Lawrence Stakeholders Coalition (LSC) is interested in assessing and understanding the potential for and pathways to electrification for the City of Lawrence. The LSC's main questions are: What is the impact of various electrification packages on residential electricity bills and what types of buildings should the LSC target for electrification plus weatherization packages? This technical assistance, using ResStock tool modeling, aims to assist the Coalition's electrification and energy burden reduction planning by: 1. Providing cross-cutting data on housing stock characteristics, energy burden characteristics, fuel types, energy consumption, and system efficiency; and 2. Providing information on upgrade package costs, emissions reduction, and energy reductions by prioritized housing segment. The ResStock analysis presented here focuses on opportunities to reduce energy burden, energy consumption, and energy bills for single family homes, multifamily buildings, and mobile homes.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Methodology to evaluate design modifications intended to eliminate frosting and high discharge temperatures in air-source heat pumps (ASHPs) in cold climates

Air-source heat pumps (ASHPs) operating in cold climates experience problems with frosting and high refrigerant temperatures. These problems increase energy consumption, and their severity depends on the climatic conditions. In the present paper, a methodology for identifying the prevailing problem between frosting and high discharge temperatures is presented. Three performance indices, the frosting index (FI), the discharge index (DI), and the total loss index (TLI), are proposed to quantify the impacts of frosting and high discharge temperatures on the annual performance of ASHPs in different climatic conditions. The FI and DI show which problem (frosting or high discharge temperature) dominates, and the TLI indicates the combined effect of frosting and high discharge temperatures on the performance of an ASHP. A thermodynamic model of an ASHP coupled with the TRNSYS building simulation tool is used to estimate the performance of an ASHP and the proposed loss indices to estimate the impact of both frosting and high discharge temperatures for 45 cities in Canada. The results can be extended to other parts of the world that experience similar climatic conditions The results reveal that in cities in ASHRAE climatic zones 5 and 6 (classified as cold regions) where the ambient air temperatures are predominantly between -15 °C to 6 °C, ASHPs are heavily impacted by frosting. The problem of high discharge temperatures in ASHPs is predominant in cities in climate zones 7 and 8 (classified as very cold and subarctic regions) where the temperatures are frequently below -20 °C in winter. Among the cities considered, St. John, NL has the highest fraction of heating hours experiencing frosting (90 %), where the annual increase in energy consumption due to frosting is 13.5 % of the annual heating energy consumption. The highest annual increase in energy consumption due to high discharge temperatures is in Isachsen, NU (zone 8), where the increase is 30 % of the annual heating energy consumption. Based on the proposed indices, another index called the performance gain index (PGI) is created, which can be used as a first step to assess the energy-saving potential of design modifications applied to ASHPs to solve the problems of frosting and high discharge temperatures. The PGI will aid in developing climate specific ASHPs. One possible design modification is the use of a two-stage ASHP with an economizer. It is observed that the two-stage ASHP with economizer can mitigate high discharge temperatures and improve performance in very cold and subarctic regions (zones 7 and 8). However, it is not as beneficial in zones 5 and 6, where the impact of high discharge temperatures on performance is minimal and frosting dominates. Finally, a case study, using the PGI to evaluate the economic and environmental effectiveness of a two-stage ASHP with economizer is presented for the city of Saskatoon.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗