At least 163 records · Page 9

NASTRAN modeling and analysis of rigid and flexible walled acoustic cavities

The acoustic slot elements, CSLOTi, are applied to analyze two-dimensional enclosures with fixed or moving boundaries. The capability utilized to compute (a) the acoustic natural modes and frequencies of a rigid walled enclosure and (b) the sound pressure at any point inside an enclosure when the surrounding walls are forced to vibrate. Applications to an automobile passenger compartment illustrate the technique. The axisymmetric fluid elements, CFLUIDi, are used in conjunction with a suitable choice of symmetry planes and a model of the surrounding structure to approximate a two-dimensional enclosure with flexible walls. The enclosure walls are modeled using finite elements or structural modes. Illustrative examples include a comparison of rectangular cavity modes with those calculated using the acoustic slot element and the free vibration modes of two enclosures coupled through a flexible rectangular panel.

Wolf, J. A., Jr.↗

Totally confined explosive welding

The undesirable by-products of explosive welding are confined and the association noise is reduced by the use of a simple enclosure into which the explosive is placed and in which the explosion occurs. An infrangible enclosure is removably attached to one of the members to be bonded at the point directly opposite the bond area. An explosive is completely confined within the enclosure at a point in close proximity to the member to be bonded and a detonating means is attached to the explosive. The balance of the enclosure, not occupied by explosive, is filled with a shaped material which directs the explosive pressure toward the bond area. A detonator adaptor controls the expansion of the enclosure by the explosive force so that the enclosure at no point experiences a discontinuity in expansion which causes rupture. The use of the technique is practical in the restricted area of a space station.

Bement, L. J.↗

Transient Convection Due to Imposed Heat Flux: Application to Liquid-Acquisition Devices

A model problem is considered that addresses the effect of heat load from an ambient laboratory environment on the temperature rise of liquid nitrogen inside an enclosure. This model has applications to liquid acquisition devices inside the cryogenic storage tanks used to transport vapor-free propellant to the main engine. We show that heat loads from Q = 0.001 to 10 W, with corresponding Rayleigh numbers from Ra = 109 to 1013, yield a range of unsteady convective states and temperature rise in the liquid. The results show that Q = 1 to 10 W (Ra = 1012 to 1013) yield temperature distributions along the enclosure height that are similar in trend to experimental measurements. Unsteady convection, which shows selfsimilarity in its planforms, is predicted for the range of heat-load conditions. The onset of convection occurs from a free-convection-dominated base flow that becomes unstable against convective instability generated at the bottom of the enclosure while the top of the enclosure is convectively stable. A number of modes are generated with small-scale thermals at the bottom of the enclosure in which the flow selforganizes into two symmetric modes prior to the onset of the propagation of the instability. These symmetric vertical modes transition to asymmetric modes that propagate as a traveling-wave-type motion of convective modes and are representative of the asymptotic convective state of the flow field. Intense vorticity production is created in the core of the flow field due to the fact that there is shear instability between the vertical and horizontal modes. For the higher Rayleigh numbers, 1012 to 1013, there is a transition from a stationary to a nonstationary response time signal of the flow and temperature fields with a mean value that increases with time over various time bands and regions of the enclosure.

Duval, Walter M. B.↗

Airlock

An airlock for use in transferring waste objects from a positively pressurized enclosure aboard an operative space vehicle, to a waste receiver attached to the vehicle and maintained at the negative pressure of a celestial space environment. The airlock is characterized by a shell having an internal chamber and hermetically sealed within an opening formed in a bulkhead of the enclosure. The shell is provided with an insertion hatch adjacent to the enclosure, and an ejection hatch adjacent the waste receiver, each of the hatches being hermetically sealed by a hatch cover supported for deployment to a hatch-opening disposition through a manipulation of a hatch-deploying mechanism. A three-way selector valve is coupled with the deploying mechanism and ported to an internal chamber of the shell, the enclosure, and the environment and is provided for alternately coupling the chamber with the enclosure and the receiver, in direct communication, in response to a manipulation of the mechanism whereby a sequence is imposed on the operation of the airlock.

Linderfelt, H. R.↗

A study of methods to predict and measure the transmission of sound through the walls of light aircraft. Numerical method for analyzing the optimal performance of active noise controllers

An optimal active noise controller is formulated and analyzed for three different active noise control problems. The first problem formulated is the active control of enclosed or partially enclosed harmonic sound fields where the noise source strengths and enclosure boundary description are known. The enclosure boundary is described by either pressure, velocity, or impedance boundary conditions. The second problem formulated is the active control of the free field power radiated from a distributed noise source with a known time harmonic surface velocity. The third problem formulated is the active control of enclosed or partially enclosed harmonic sound field where the noise source strengths of enclosure boundary description may not be known. All three formulations are derived using an indirect boundary element technique. Formulation and verification of an indirect boundary element method is presented. The active noise controller formulations for enclosures are capable of analyzing systems with generalized enclosure shapes, point noise sources, and/or locally reacting impedance boundary conditions. For each formulation, representative results of optimal active noise controller case studies are presented, and some general conclusions are drawn.

Mollo, Christopher G.↗

Solar-Powered Refrigeration System

A solar powered vapor compression refrigeration system is made practicable with thermal storage and novel control techniques. In one embodiment, the refrigeration system includes a photovoltaic panel, a variable speed compressor, an insulated enclosure. and a thermal reservoir. The photovoltaic (PV) panel converts sunlight into DC (direct current) electrical power. The DC electrical power drives a compressor that circulates refrigerant through a vapor compression refrigeration loop to extract heat from the insulated enclosure. The thermal reservoir is situated inside the insulated enclosure and includes a phase change material. As heat is extracted from the insulated enclosure, the phase change material is frozen, and thereafter is able to act as a heat sink to maintain the temperature of the insulated enclosure in the absence of sunlight. The conversion of solar power into stored thermal energy is optimized by a compressor control method that effectively maximizes the compressor's usage of available energy. A capacitor is provided to smooth the power voltage and to provide additional current during compressor start-up. A controller monitors the rate of change of the smoothed power voltage to determine if the compressor is operating below or above the available power maximum, and adjusts the compressor speed accordingly. In this manner, the compressor operation is adjusted to convert substantially all available solar power into stored thermal energy.

Ewert, Michael K.↗

Solar Powered Refrigeration System

A solar powered vapor compression refrigeration system is made practicable with thermal storage and novel control techniques. In one embodiment, the refrigeration system includes a photovoltaic panel, a variable speed compressor, an insulated enclosure, and a thermal reservoir. The photovoltaic (PV) panel converts sunlight into DC (direct current) electrical power. The DC electrical power drives a compressor that circulates refrigerant through a vapor compression refrigeration loop to extract heat from the insulated enclosure. The thermal reservoir is situated inside the insulated enclosure and includes a phase change material. As heat is extracted from the insulated enclosure, the phase change material is frozen, and thereafter is able to act as a heat sink to maintain the temperature of the insulated enclosure in the absence of sunlight. The conversion of solar power into stored thermal energy is optimized by a compressor control method that effectively maximizes the compressor's usage of available energy. A capacitor is provided to smooth the power voltage and to provide additional current during compressor start-up. A controller monitors the rate of change of the smoothed power voltage to determine if the compressor is operating below or above the available power maximum, and adjusts the compressor speed accordingly. In this manner, the compressor operation is adjusted to convert substantially all available solar power into stored thermal energy.

Michael K Ewert↗

Solar-Powered Refrigeration System

A solar powered vapor compression refrigeration system is made practicable with thermal storage and novel control techniques. In one embodiment, the refrigeration system includes a photovoltaic panel, a variable speed compressor, an insulated enclosure, and a thermal reservoir. The photovoltaic (PV) panel converts sunlight into DC (direct current) electrical power. The DC electrical power drives a compressor that circulates refrigerant through a vapor compression refrigeration loop to extract heat from the insulated enclosure. The thermal reservoir is situated inside the insulated enclosure and includes a phase change material. As heat is extracted from the insulated enclosure, the phase change material is frozen, and thereafter is able to act as a heat sink to maintain the temperature of the insulated enclosure in the absence of sunlight. The conversion of solar power into stored thermal energy is optimized by a compressor control method that effectively maximizes the compressor's usage of available energy. A capacitor is provided to smooth the power voltage and to provide additional current during compressor start-up. A controller monitors the rate of change of the smoothed power voltage to determine if the compressor is operating below or above the available power maximum, and adjusts the compressor speed accordingly. In this manner, the compressor operation is adjusted to convert substantially all available solar power into stored thermal energy.

Michael K Ewert↗

Animal biocalorimeter and waste management system

A biocalorimeter and waste management system is provided for making metabolic heat release measurements of animals or humans in a calorimeter (enclosure) using ambient air as a low velocity source of ventilating air through the enclosure. A shroud forces ventilating air to pass over the enclosure from an end open to ambient air at the end of the enclosure opposite its ventilating air inlet end and closed around the inlet end of the enclosure in order to obviate the need for regulating ambient air temperature. Psychrometers for measuring dry- and wet-bulb temperature of ventilating air make it possible to account for the sensible and latent heat additions to the ventilating air. A waste removal system momentarily recirculates high velocity air in a closed circuit through the calorimeter wherein a sudden rise in moisture is detected in the ventilating air from the outlet.

Poppendiek, Heinz F.↗

Environmental Testing of Contamination Sensitive Instruments and Optics in Non-Cleanliness Controlled Facilities

The James Webb Space Telescope (JWST) Optical Telescope Element + Integrated Science Instrument Module (OTIS) went through environmental testing at the Goddard Space Flight Center. The vibration and acoustic tests occurred outside of cleanrooms. These areas are typically around ISO Class 8, far out of specifications for JWST. Through collaboration between the OTIS Mechanical and Contamination Engineering teams, a portable clean enclosure was designed, built, and verified to prevent contamination of the sensitive OTIS assembly. This manuscript describes the process of designing and building this enclosure, including materials selection and High Efficiency Particle Air (HEPA) filtration. This enclosure also provided environmental control with a portable air conditioning unit to control the relative humidity level enabling personnel to work within it. The manuscript emphasizes working in a systematic order to maintain cleanliness and integrity. “Clean as you go” during construction was a top priority to ensure that this critical Ground Support Equipment (GSE) was acceptable. The process of installing the walls and then sealing their internal and external surfaces with approved films was critical to maintaining OTIS integrity. This proved important because OTIS was in the enclosure for months longer than originally planned. This manuscript concludes by reviewing the process used to verify that the OTIS clean enclosure could achieve acceptable contamination level fallout accumulation for use during the vibration and acoustic testing and then verifying that the predicted performance was achieved after testing was complete.

Contamination Control, James Webb Space Telescope,↗

Geopolymer Lunar Concrete under Reduced-Pressure Curing and Vacuum Exposure

Geopolymer concrete has emerged as a promising material for constructing habitats, roads, landing pads, and other necessary infrastructure on the lunar surface. Proper in-situ resource utilization (ISRU) is an important aspect of any candidate lunar construction material. Geopolymer concrete is effective at ISRU, as the lunar regolith can be used in the “as found” condition and mixed with an alkaline solution, such as sodium silicate and sodium hydroxide, which could also be mostly produced in-situ. It is envisioned that any concrete material on the lunar surface would be deposited with additive manufacturing techniques and would require a temporary environmental enclosure to mitigate the harsh lunar environment during construction and curing, such as pressure and temperature. Data are needed to set a benchmark for the conditions to be achieved within the deployable environmental enclosure during printing, as well as the resultant material properties after the enclosure is removed. This novel study investigated the influence of reduced atmospheric pressures during the initial curing period on the compressive strength of geopolymer lunar concrete created with two types of lunar regolith simulant. The simulants used in the study represent the regolith for the lunar mare (OPRL2N) and lunar highlands (OPRH2N) regions. Results show a noticeable decline in strength with a reduction in pressure and visible degradation. After the deployable environmental enclosure is removed from the printed segment of infrastructure on the lunar surface, it would then be exposed to the harsh vacuum environment. To understand the importance of curing time required within the deployable enclosure before it is removed, samples were cast and cured for different lengths of time and then exposed to a vacuum chamber capable of achieving 100 mTorr. Control samples were also cast at the same time but left in a standard laboratory environment after curing. The weight change and compressive strength as a function of time in the vacuum chamber were monitored for up to 56 days. The results showed that exposure to the vacuum limits further reaction and strength gain in comparison to control samples left in the laboratory environment. This research is in strong alignment with the 2020 NASA Technology Taxonomy materials area (12.1) and the in-situ resource utilization area (7.1), as it provides necessary data on the geopolymer lunar concrete material to support safe and sustainable options for maintaining a human presence on the Moon.

Moon to Mars Planetary Autonomous Construction Tec↗

Decreasing Proton Single Event Effects in CubeSats with Shielding

Shields-1, NORAD ID 43850,has been operating in polar low earth orbit since December 2018. The shielding has resulted in a lower total ionizing dose over time than typical aluminum thin-walled CubeSat structures. The reduced ionizing dosage caused by Shields-1 increases the reliability of commercial parts and reduces internal charging. Furthermore, the Shields-1 shielding reduces the ionizing particle fluence inside the spacecraft that contributes to the ionizing dose. NOVICE Sigma shielding software, using the (Aerospace Proton) AP8 –(Aerospace Electron) AE8 solar minimum trapped belt environment for a 1-year mission, estimates a 21.3 g/cm2 aluminum effective shielding for the Shields-1 electronics enclosure. This high areal density reduces not only the total number of energetic protons, but also reduces the number of ionizing particles over all modeled energies from the estimated shielded fluence for a 1-year mission. NOVICE Adjoint CAD modeling of the Shields-1 structure, with the detector located within the electronics enclosure, estimates that the total number of particles is reduced from 2.20x 10exp9 protons/cm2 to 1.52x 10exp8 protons/cm2, which represents 6.90% of the remaining particles(figure 1). By slowing down approximations of the integral proton fluence, a minimum proton threshold is estimated at 151 MeV. In comparison, a 0.204-cm aluminum thin-walled 3-unit (U) structure, with a 0.907 g/cm2 effective shielding, has 25.0% remaining particles and a minimum proton threshold of 36.2 MeV(figure 1). Proton energies that contribute to single event effects in radiation tolerant or higher semiconductor hardness are typically 100 MeV and higher. The Shields-1 electronics enclosure is estimated to attenuate energies: 100 MeV by 76.5%, 200 MeV by 61.7%, and 500 MeV by 63.0%(figure 2), when comparing the space environment proton differential fluence with the shielded differential fluence. The aluminum thin-walled structure is estimated to attenuate proton energies: 100 MeV by 13.7%, 200 MeV by 12.4%, and 500 MeV by 12.6%(figure 2), which are lower than for the Shields-1 electronics enclosure. The significant differences in attenuation between the Shields-1 electronics enclosure and aluminum thin-walled 3U structure show the additional utility of increasing shielding effectiveness for reducing the numbers of energetic protons that contribute to single event effects.

Larry Thomsen↗

Totally confined explosive welding

A method and associated apparatus for confining the undesirable by-products and limiting noise of explosive welding are discussed. The apparatus consists fo a simple enclosure into which the explosive is placed and within which the explosion occurs. The shape of the enclosure, the placement of the explosive, and the manner in which the enclosure is placed upon the material to be welded determine the force of the explosion transmitted to the proposed bond area. The explosion is totally confined within the enclosure thus reducing the noise level and preventing debris from being strewn about to contaminate the weld area or create personnel hazards.

Bement, L. J.↗

Asymptotic modal analysis and statistical energy analysis

The sound field of a structural-acoustic enclosure was subject to experimental analysis and theoretical description in order to develop an efficient and accurate method for predicting sound pressure levels in enclosures such as aircraft fuselages. Asymptotic Modal Analysis (AMA) is the method under investigation. AMA is derived from classical modal analysis (CMA) by considering the asymptotic limit of the sound pressure level as the number of acoustic and/or structural modes approaches infinity. Using AMA, results identical to those of Statistical Energy Analysis (SEA) were obtained for the spatially-averaged sound pressure levels in the interior. AMA is systematically derived from CMA and therefore the degree of generality of the end result can be adjusted through the choice of appropriate simplifying assumptions. For example, AMA can be used to obtain local sound pressure levels at particular points inside the enclosure, or to include the effects of varying the size and/or location of the sound source. AMA theoretical results were compared with CMA theory and also with experiment for the case where the structural-acoustic enclosure is a rectangular cavity with part of one wall flexible and vibrating, while the rest of the cavity is rigid.

Dowell, Earl H.↗

Laboratory test and acoustic analysis of cabin treatment for propfan test assessment aircraft

An aircraft cabin acoustic enclosure, built in support of the Propfan Test Assessment (PTA) program, is described. Helmholtz resonators were attached to the cabin trim panels to increase the sidewall transmission loss (TL). Resonators (448) were located between the trim panels and fuselage shell. In addition, 152 resonators were placed between the enclosure and aircraft floors. The 600 resonators were each tuned to a 235 Hz resonance frequency. After flight testing on the PTA aircraft, the enclosure was tested in the Kelly Johnson R and D Center Acoustics Lab. Laboratory noise reduction (NR) test results are discussed. The enclosure was placed in a Gulfstream 2 fuselage section. Broadband (138 dB overall SPL) and tonal (149 dB overall SPL) excitations were used in the lab. Tonal excitation simulated the propfan flight test excitation. The fundamental tone was stepped in 2 Hz intervals from 225 through 245 Hz. The resonators increase the NR of the cabin walls around the resonance frequency of the resonator array. The effects of flanking, sidewall absorption, cabin adsorption, resonator loading of trim panels, and panel vibrations are presented. Increases in NR of up to 11 dB were measured.

Kuntz, H. L.↗

Development and testing of cabin sidewall acoustic resonators for the reduction of cabin tone levels in propfan-powered aircraft

The use of Helmholtz resonators to increase the sidewall transmission loss (TL) in aircraft cabin sidewalls is evaluated. Development, construction, and test of an aircraft cabin acoustic enclosure, built in support of the Propfan Test Assessment (PTA) program, is described. Laboratory and flight test results are discussed. Resonators (448) were located between the enclosure trim panels and the fuselage shell. In addition, 152 resonators were placed between the enclosure and aircraft floors. The 600 resonators were each tuned to a propfan fundamental blade passage frequency (235 Hz). After flight testing on the PTA aircraft, noise reduction (NR) tests were performed with the enclosure in the Kelly Johnson Research and Development Center Acoustics Laboratory. Broadband and tonal excitations were used in the laboratory. Tonal excitation simulated the propfan flight test excitation. The resonators increase the NR of the cabin walls around the resonance frequency of the resonator array. Increases in NR of up to 11 dB were measured. The effects of flanking, sidewall absorption, cabin absorption, resonator loading of trim panels, and panel vibrations are presented. Resonator and sidewall panel design and test are discussed.

Kuntz, H. L.↗

Electromagnetic Field Penetration Studies

A numerical method is presented to determine electromagnetic shielding effectiveness of rectangular enclosure with apertures on its wall used for input and output connections, control panels, visual-access windows, ventilation panels, etc. Expressing EM fields in terms of cavity Green's function inside the enclosure and the free space Green's function outside the enclosure, integral equations with aperture tangential electric fields as unknown variables are obtained by enforcing the continuity of tangential electric and magnetic fields across the apertures. Using the Method of Moments, the integral equations are solved for unknown aperture fields. From these aperture fields, the EM field inside a rectangular enclosure due to external electromagnetic sources are determined. Numerical results on electric field shielding of a rectangular cavity with a thin rectangular slot obtained using the present method are compared with the results obtained using simple transmission line technique for code validation. The present technique is applied to determine field penetration inside a Boeing-757 by approximating its passenger cabin as a rectangular cavity filled with a homogeneous medium and its passenger windows by rectangular apertures. Preliminary results for, two windows, one on each side of fuselage were considered. Numerical results for Boeing-757 at frequencies 26 MHz, 171-175 MHz, and 428-432 MHz are presented.

Deshpande, M.D.↗

Pressure Control System Design for a Closed Crop Growth Chamber

The Controlled Ecological Life Support System (CELSS) is an area of active research at NASA. CELSS is a plant-based bioregenerative life support system for long term manned space flights where resupply is costly or impractical. The plants in a CELSS will function to convert the carbon dioxide (exhaled by the crew) into oxygen, purify non-potable water into potable quality water, and provide food for the crew. Prior to implementing a CELSS life support system, one must have knowledge on growing plants in a closed chamber under low gravity. This information will come from research to be conducted on the CELSS Test Facility that will operate on the Space Station Freedom. Currently a ground-based CELSS Test Facility is being built at NASA Ames Research Center. It is called the EDU (Engineering Development Unit). This system will allow researchers to identify issues that may cause difficulties in the development of the CELSS Test Facility and aid in the development of new needed technologies. The EDU consists of a 1 m2 crop growth chamber that is surrounded by a containment enclosure. The containment enclosure isolates the system so there is very little mass and thermal exchange with the ambient. The leakage rate is on the order of 1 % of the enclosure's volume per day (with 0.2S psi pressure difference). The thermal leakage is less than 0.5% of the electrical power supplied to the system per degree Celsius difference from the surrounding. The pressure in the containment enclosure is regulated at 62.5 Pa below the ambient by an active controller. The goal is to maintain this set point for a variety of conditions, such as a range of operating temperatures, heat load variations that occur when the lights are turned on and off, and fluctuations in ambient pressure. In addition certain transition tracking performance is required. This paper illustrates the application of some advanced systems control methods to the task of synthesizing the EDU's pressure control system.