At least 163 records · Page 9

A New Look at Historic CRAC 'Divergence' Experiments - Implications for a CAAS Minimum Accident of Concern

This paper examines power history parameters and results based on historic fissile solution criticality 'divergence' experiments (referenced here as Divergence Experiments) from the 1960's-70's' Consequences Radiologiques d'un Accident de Criticite' (CRAC) campaign. The results from specific Divergence Experiments have implications for an ANSI/ANS-8.3 (1997) Criticality Accident Alarm System (CAAS) Minimum Accident of Concern (MAC). Specifically, this paper examines select CRAC Divergence Experiments in conjunction with 'qualifying reactivity additions' for a MAC defined by an absolute time constraint. A previous paper presented at the 2011 International Conference on Nuclear Criticality (ICNC 2011) illustrated the differences in 'qualifying reactivity additions' above delayed critical (and below prompt) for a variety of MAC constructs. That paper was the first to examine delayed critical kinetics in greater detail over a range of process and MAC considerations. The ICNC2011 work did not consider an absolute MAC time constraint from the excursion onset and assumed an initial excursion power. That study evaluated MAC constructs based on 'relative time differences' between reaching a specific fission rate and total fissions. The work presented here thus picks up where the ICNC2011 study left off. The primary focus of this work provides simulated power histories for specific Divergence Experiments that served as a basis for justifying a MAC noted in ANS-8.3 Appendix A. This paper documents computational modeling and dynamic multiphysics simulation with known Divergence Experiment parameters for reactivity additions at, below, and above the reported terminal reactivity. The initial step considers replicating what could be a reasonable power history for the terminal reactivity addition to the extent the same peak power and total fissions are obtained over the total time considered. Power histories for all other reactivity additions are simulated by varying the input reactivity and solution heights for the same model. A relationship is obtained between reactivity addition and the time to reach specific MAC power and fission levels within a given time constraint (e.g. 60 s). The 'qualifying reactivity addition' is determined for the total MAC fissions within that time. This value is then compared to the historic terminal value (e.g. $0.33) or any other values (e.g. 'excess reactivity of only a few cents') noted in ANS-8.3 Appendix A. In general, calculated MAC power levels have ranged from 1.8 kW to 173 kW depending on material type and form, H/U, enrichment, critical volume, and dose response function. A minimum accident consideration noted a SHEBA experiment with an excess reactivity 7 cents above delayed critical (TD ∼110 s). This excursion provided an additional 10{sup 15} fissions after an undetermined buildup time resulting in a 'few times 10{sup 15} fissions'. ICNC 2011 LEU solutions calculations show 0.2 Gy in air corresponds to 1.4 x10{sup 16} fissions. Thus, while historically, 0.2 Gy has been loosely associated with 'several times 10{sup 15} fissions', in reality, the actual total fissions could be an order of magnitude larger, and the power associated with 0.2 Gy/min (7.5 kW) larger as well. The reactivity addition required to obtain the actual 0.2 Gy total fissions over 60 s could be much larger than considered. Another reason the qualifying reactivity level could be larger than previously noted, involves temperature reactivity feedback. Compensated reactivity results in a departure from a pure exponential power rise, increasing the doubling time (TD) as the excursion approaches peak power. Uncompensated reactivity additions and constant TD have been traditionally assumed for a pure exponential power rise through the kW range to determine either total MAC fissions, power, or arrival time to these values.

42 ENGINEERING↗

Intrafraction Variability and Deformation Quantification in the Breast

Purpose: To evaluate intrafraction variability and deformation of the lumpectomy cavity (LC), breast, and nearby organs. Methods and Materials: Sixteen left-sided postlumpectomy and 1 bilateral breast cancer cases underwent free-breathing CT (FBCT) and 10-phase 4-dimensional CT (4DCT). Deformable image registration was used for deformation analysis and contour propagation of breast, heart, lungs, and LC between end-exhale and end-inhale 4DCT phases. Respiration-induced motion was calculated via centroid analysis. Two planning target volumes (PTVs) were compared: PTV{sub FBCT} from the FBCT volume with an isotropic 10 mm expansion (5 mm excursion and 5 mm setup error) and PTV{sub 4DCT} generated from the union of 4DCT contours with isotropic 5 mm margin for setup error. Volume and geometry were evaluated via percent difference and bounding box analysis, respectively. Deformation correlations between breast/cavity, breast/lung, and breast/heart were evaluated. Associations were tested between cavity deformation and proximity to chest wall and breast surface. Results: Population-based 3-dimensional vector excursions were 2.5 ± 1.0 mm (range, 0.8-3.8 mm) for the cavity and 2.0 ± 0.8 mm (range, 0.7-3.0 mm) for the ipsilateral breast. Cavity excursion was predominantly in the anterior and superior directions (1.0 ± 0.8 mm and −1.8 ± 1.2 mm, respectively). Similarly, for all cases, LCs and ipsilateral breasts yielded median deformation values in the superior direction. For 14 of 17 patients, the LCs and breast interquartile ranges tended toward the anterior direction. The PTV{sub FBCT} was 51.5% ± 10.8% larger (P<.01) than PTV{sub 4DCT}. Bounding box analysis revealed that PTV{sub FBCT} was 9.8 ± 1.2 (lateral), 9.0 ± 2.2 (anterior–posterior), and 3.9 ± 1.8 (superior–inferior) mm larger than PTV{sub 4DCT}. Significant associations between breast and cavity deformation were found for 6 of 9 axes. No dependency was found between cavity deformation and proximity to chest wall or breast surface. Conclusions: Lumpectomy cavity and breast deformation and motion demonstrated large variability. A PTV{sub 4DCT} approach showed value in patient-specific margins, particularly if robust interfraction setup analysis can be performed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The criticality incident detection system omission cases for the fuel routes at EDF energy power stations - 14280

Criticality safety cases have been produced to justify the omission of criticality alarms from the fuel routes of EDF Energy's UK power stations. This work has addressed the UK regulator's expectations that adequate criticality warning systems should be provided wherever fissile material is present, unless a safety case shows that no criticality excursion could give any individual a whole body dose exceeding the annual whole body dose limit of 20 mSv, or that the predicted frequency of such excursions is acceptably low. In the UK, EDF Energy operates eight nuclear power stations; one Pressurized Water Reactor (PWR) and seven Advanced Gas-cooled Reactor stations (AGRs). At these stations, the term 'fuel route' is used to encompass all of the ex-reactor arrangements for the handling and storage of both new fuel and discharged irradiated fuel. These fuel routes were all designed in the 1980's (or earlier), using sound deterministic criticality safety principles, from which it was concluded that criticality alarms were not required in any of these areas. Subsequent changes to UK regulations have resulted in the need for the stations' criticality safety cases to be updated to include formal justifications for the omission of criticality alarms from these fuel routes. The EDF Energy Criticality Incident Detection System (CIDS) omission cases have been produced using the principles originally developed for UKAEA in the early 1960's by Aspinall and Daniels. These principles continue to be regarded as a best-practice approach by UK industry. Modern UK regulations also incorporate the ALARP principle, which requires operators to minimize and balance all of the safety risks from power station operations, so that the risks to both the public and to workers are As Low As is Reasonably Practicable. This paper describes how the work undertaken used the so-called Aspinall and Daniels criteria in conjunction with the requirements of the ALARP principle. The fuel storage pond at the Sizewell B PWR was addressed by dose calculations to show that, from the shielding effects of the concrete structure and the pond water, the potential consequences of a criticality accident could not result in a radiation dose in excess of 20 mSv. All of the other fuel route areas were addressed on the basis that, even if all of the active engineered and administrative criticality controls were to fail, a criticality accident would still not be reasonably expected, i.e. the predicted frequencies of all such excursions are acceptably low. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Modeling the measured effect of a nitroplasticizer (BDNPA/F) on cookoff of a plastic bonded explosive (PBX 9501)

Here, we have used a modified version of the Sandia Instrumented Thermal Ignition (SITI) experiment to develop a pressure-dependent, five-step ignition model for a plastic bonded explosive (PBX 9501) consisting of 95 wt% octahydro-1,3,5,7-tetranitro-1,3,5,7-tetrazoncine (HMX), 2.5 wt% Estane® 5703 (a polyurethane thermoplastic), and 2.5 wt% of a nitroplasticizer (NP): BDNPA/F, a 50/50 wt% eutectic mixture bis(2,2-dinitropropyl)-acetal (BDNPA) and bis(2,2-dinitropropyl)-formal (BDNPF). The five steps include desorption of water, decomposition of the NP to form NO2, reaction of the NO2 with Estane® and HMX, and decomposition of HMX. The model was fit using our experiments and successfully validated with experiments from five other laboratories with scales ranging from about 2 g to more than 2.5 kg of PBX. Our experimental variables included density, confinement, free gas volume, and temperature. We measured internal temperatures, confinement pressure, and ignition time. In some of our experiments, we used a borescope to visually observe the decomposing PBX. Our observations included the endothermic β–δ phase change of the HMX, a small exothermic temperature excursion in low-density unconfined experiments, and runaway ignition. We hypothesize that the temperature excursion in these low density experiments was associated with the NP decomposing exothermically within the PBX sample. This reactant-limited temperature excursion was not observed with our thermocouples in the high-density experiments. For these experiments, we believe the binder diffused to the edges of our high density samples and decomposed next to the highly conductive wall as confirmed by our borescope images.

42 ENGINEERING↗

Intrafraction Variation of Mean Tumor Position During Image-Guided Hypofractionated Stereotactic Body Radiotherapy for Lung Cancer

Purpose: Prolonged delivery times during daily cone-beam computed tomography (CBCT)-guided lung stereotactic body radiotherapy (SBRT) introduce concerns regarding intrafraction variation (IFV) of the mean target position (MTP). The purpose of this study was to evaluate the magnitude of the IFV-MTP and to assess target margins required to compensate for IFV and postonline CBCT correction residuals. Patient, treatment, and tumor characteristics were analyzed with respect to their impact on IFV-MTP. Methods and Materials: A total of 126 patients with 140 tumors underwent 659 fractions of lung SBRT. Dose prescribed was 48 or 60 Gy in 12 Gy fractions. Translational target position correction of the MTP was performed via onboard CBCT. IFV-MTP was measured as the difference in MTP between the postcorrection CBCT and the posttreatment CBCT excluding residual error. Results: IFV-MTP was 0.2 {+-} 1.8 mm, 0.1 {+-} 1.9 mm, and 0.01 {+-} 1.5 mm in the craniocaudal, anteroposterior, and mediolateral dimensions and the IFV-MTP vector was 2.3 {+-} 2.1 mm. Treatment time and excursion were found to be significant predictors of IFV-MTP. An IFV-MTP vector greater than 2 and 5 mm was seen in 40.8% and 7.2% of fractions, respectively. IFV-MTP greater than 2 mm was seen in heavier patients with larger excursions and longer treatment times. Significant differences in IFV-MTP were seen between immobilization devices. The stereotactic frame immobilization device was found to be significantly less likely to have an IFV-MTP vector greater than 2 mm compared with the alpha cradle, BodyFIX, and hybrid immobilization devices. Conclusions: Treatment time and respiratory excursion are significantly associated with IFV-MTP. Significant differences in IFV-MTP were found between immobilization devices. Target margins for IFV-MTP plus post-correction residuals are dependent on immobilization device with 5-mm uniform margins being acceptable for the frame immobilization device.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Kilovoltage Intrafraction Monitoring for Prostate Intensity Modulated Arc Therapy: First Clinical Results

Purpose: Most linear accelerators purchased today are equipped with a gantry-mounted kilovoltage X-ray imager which is typically used for patient imaging prior to therapy. A novel application of the X-ray system is kilovoltage intrafraction monitoring (KIM), in which the 3-dimensional (3D) tumor position is determined during treatment. In this paper, we report on the first use of KIM in a prospective clinical study of prostate cancer patients undergoing intensity modulated arc therapy (IMAT). Methods and Materials: Ten prostate cancer patients with implanted fiducial markers undergoing conventionally fractionated IMAT (RapidArc) were enrolled in an ethics-approved study of KIM. KIM involves acquiring kV images as the gantry rotates around the patient during treatment. Post-treatment, markers in these images were segmented to obtain 2D positions. From the 2D positions, a maximum likelihood estimation of a probability density function was used to obtain 3D prostate trajectories. The trajectories were analyzed to determine the motion type and the percentage of time the prostate was displaced {>=}3, 5, 7, and 10 mm. Independent verification of KIM positional accuracy was performed using kV/MV triangulation. Results: KIM was performed for 268 fractions. Various prostate trajectories were observed (ie, continuous target drift, transient excursion, stable target position, persistent excursion, high-frequency excursions, and erratic behavior). For all patients, 3D displacements of {>=}3, 5, 7, and 10 mm were observed 5.6%, 2.2%, 0.7% and 0.4% of the time, respectively. The average systematic accuracy of KIM was measured at 0.46 mm. Conclusions: KIM for prostate IMAT was successfully implemented clinically for the first time. Key advantages of this method are (1) submillimeter accuracy, (2) widespread applicability, and (3) a low barrier to clinical implementation. A disadvantage is that KIM delivers additional imaging dose to the patient.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

ON-DISK COUNTERPARTS OF TYPE II SPICULES IN THE Ca II 854.2 nm AND Halpha LINES

Recently, a second type of spicules was discovered at the solar limb with the Solar Optical Telescope onboard the Japanese Hinode spacecraft. These previously unrecognized type II spicules are thin chromospheric jets that are shorter lived (10-60 s) and that show much higher apparent upward velocities (of order 50-100 km s{sup -1}) than the classical spicules. Since they have been implicated in providing hot plasma to coronal loops, their formation, evolution, and properties are important ingredients for a better understanding of the mass and energy balance of the low solar atmosphere. Here, we report on the discovery of the disk counterparts of type II spicules using spectral imaging data in the Ca II 854.2 nm and Halpha lines with the CRisp Imaging SpectroPolarimeter at the Swedish Solar Telescope in La Palma. We find rapid blueward excursions in the line profiles of both chromospheric lines that correspond to thin, jet-like features that show apparent velocities of order 50 km s{sup -1}. These blueward excursions seem to form a separate absorbing component with Doppler shifts of order 20 and 50 km s{sup -1} for the Ca II 854.2 nm and Halpha line, respectively. We show that the appearance, lifetimes, longitudinal and transverse velocities, and occurrence rate of these rapid blue excursions on the disk are very similar to those of the type II spicules at the limb. A detailed study of the spectral line profiles in these events suggests that plasma is accelerated along the jet, and plasma is being heated throughout the short lifetime of the event.

79 ASTRONOMY AND ASTROPHYSICS↗

Early dark sector, the Hubble tension, and the swampland

We consider the interplay of the Early Dark Energy (EDE) model, the Swampland Distance Conjecture (SDC), and cosmological parameter tensions. EDE is a proposed resolution of the Hubble tension relying upon a near-Planckian scalar field excursion, while the SDC predicts an exponential sensitivity of masses of other fields to such an excursion, m ∝ e –c |ΔΦ|/Mpl with c ~ 0(1). Meanwhile, EDE is in tension with large-scale structure (LSS) data, due to shifts in the standard ΛCDM parameters necessary to fit the cosmic microwave background (CMB). One might hope that a proper treatment of the model, e.g., accounting for the SDC, may ameliorate the tension with LSS. Motivated by these considerations, we introduce the Early Dark Sector (EDS) model, wherein the mass of dark matter is exponentially sensitive to super-Planckian field excursions of the EDE scalar. The EDS model exhibits new phenomenology in both the early and late universe, the latter due to an EDE-mediated dark matter self-interaction. This dark matter-philic "fifth force", while constrained to be small, remains active in the late universe and is not screened in virialized halos. We find that the new interaction with dark matter partially resolves the LSS tension. However, the marginalized posteriors are nonetheless consistent with f EDE = 0 at 95% CL once the Dark Energy Survey Year 3 measurement of S 8 is included. We study constraints on the model from Atacama Cosmology Telescope data, and find a factor of two improvement on the error bar on the SDC parameter c, along with an increased preference for the EDE component. Here, we discuss the implications of these constraints for the SDC, and find the tightest observational constraints to date on a swampland parameter, suggesting that an EDE description of cosmological data is in tension with the SDC.

79 ASTRONOMY AND ASTROPHYSICS↗

Continuous monitoring of prostate position using stereoscopic and monoscopic kV image guidance

Purpose: To demonstrate continuous kV x-ray monitoring of prostate motion using both stereoscopic and monoscopic localizations, assess the spatial accuracy of these techniques, and evaluate the dose delivered from the added image guidance. Methods: The authors implemented both stereoscopic and monoscopic fiducial localizations using a room-mounted dual oblique x-ray system. Recently developed monoscopic 3D position estimation techniques potentially overcome the issue of treatment head interference with stereoscopic imaging at certain gantry angles. To demonstrate continuous position monitoring, a gold fiducial marker was placed in an anthropomorphic phantom and placed on the Linac couch. The couch was used as a programmable translation stage. The couch was programmed with a series of patient prostate motion trajectories exemplifying five distinct categories: stable prostate, slow drift, persistent excursion, transient excursion, and high frequency excursions. The phantom and fiducial were imaged using 140 kVp, 0.63 mAs per image at 1 Hz for a 60 s monitoring period. Both stereoscopic and monoscopic 3D localization accuracies were assessed by comparison to the ground-truth obtained from the Linac log file. Imaging dose was also assessed, using optically stimulated luminescence dosimeter inserts in the phantom. Results: Stereoscopic localization accuracy varied between 0.13 ± 0.05 and 0.33 ± 0.30 mm, depending on the motion trajectory. Monoscopic localization accuracy varied from 0.2 ± 0.1 to 1.1 ± 0.7 mm. The largest localization errors were typically observed in the left–right direction. There were significant differences in accuracy between the two monoscopic views, but which view was better varied from trajectory to trajectory. The imaging dose was measured to be between 2 and 15 μGy/mAs, depending on location in the phantom. Conclusions: The authors have demonstrated the first use of monoscopic localization for a room-mounted dual x-ray system. Three-dimensional position estimation from monoscopic imaging permits continuous, uninterrupted intrafraction motion monitoring even in the presence of gantry rotation, which may block kV sources or imagers. This potentially allows for more accurate treatment delivery, by ensuring that the prostate does not deviate substantially from the initial setup position.

60 APPLIED LIFE SCIENCES↗

Rocky Flats Neutron Detector Testing at Valduc, France

Recent program requirements of the US Department of Energy/NNSA have led to a need for a criticality accident alarm system to be installed at a newly activated facility. The Criticality Safety Group of the Lawrence Livermore National Laboratory (LLNL) was able to recover and store for possible future use approximately 200 neutron criticality detectors and 20 master alarm panels from the former Rocky Flats Plant in Golden, Colorado when the plant was closed. The Criticality Safety Group participated in a facility analysis and evaluation, the engineering design and review process, as well as the refurbishment, testing, and recalibration of the Rocky Flats criticality alarm system equipment to be used in the new facility. In order to demonstrate the functionality and survivability of the neutron detectors to the effects of an actual criticality accident, neutron detector testing was performed at the French CEA Valduc SILENE reactor from October 7 to October 19, 2010. The neutron detectors were exposed to three criticality events or pulses generated by the SILENE reactor. The first excursion was performed with a bare or unshielded reactor, and the second excursion was made with a lead shielded/reflected reactor, and the third excursion with a polyethylene reflected core. These tests of the Rocky Flats neutron detectors were performed as a part of the 2010 Criticality Accident Alarm System Benchmark Measurements at the SILENE Reactor. The principal investigators for this series of experiments were Thomas M. Miller and John C. Wagner of the Oak Ridge National Laboratory, with Nicolas Authier and Nathalie Baclet of CEA Valduc. Several other organizations were also represented, including the Y-12 National Security Complex, Lawrence Livermore National Laboratory, Los Alamos National Laboratory, CEA Saclay, and Babcock International Group.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quasi-optimum design of a six degree of freedom moving base simulator control system

The design of a washout control system for a moving base simulator is treated by a quasi-optimum control technique. The broad objective of the design is to reproduce the sensed motion of a six degree of freedom simulator as accurately as possible without causing the simulator excursions to exceed specified limits. A performance criterion is established that weights magnitude and direction errors in specific force and in angular velocity and attempts to maintain the excursion within set limits by penalizing excessive excursions. A FORTRAN routine for relizing the washout law was developed and typical time histories using the washout routine were simulated for a range of parameters in the penalty- and weighting-functions. These time histories and the listing of the routine are included in the report.

Friedland, B.↗

Turbulence flight director analysis and preliminary simulation

A control column and trottle flight director display system is synthesized for use during flight through severe turbulence. The column system is designed to minimize airspeed excursions without overdriving attitude. The throttle system is designed to augment the airspeed regulation and provide an indication of the trim thrust required for any desired flight path angle. Together they form an energy management system to provide harmonious display indications of current aircraft motions and required corrective action, minimize gust upset tendencies, minimize unsafe aircraft excursions, and maintain satisfactory ride qualities. A preliminary fixed-base piloted simulation verified the analysis and provided a shakedown for a more sophisticated moving-base simulation to be accomplished next. This preliminary simulation utilized a flight scenario concept combining piloting tasks, random turbulence, and discrete gusts to create a high but realistic pilot workload conducive to pilot error and potential upset. The turbulence director (energy management) system significantly reduced pilot workload and minimized unsafe aircraft excursions.

Johnson, D. E.↗

Magnetic flux ropes in the Venus ionosphere - Observations and models

Pioneer Venus Orbiter data are used as evidence of naturally occurring magnetic field filamentary structures which can be described by a flux rope model. The solar wind is interpreted as piling up a magnetic field on the Venus ionosphere, with the incident ram pressure being expressed as magnetic field pressure. Currents flowing at the ionopause shield out the field, allowing magnetic excursions to be observed with magnitudes of tens of nT over an interval of a few seconds. A quantitative assessment is made of the signature expected from a flux rope. It is noted that each excursion of the magnetic field detected by the Orbiter magnetometer was correlated with variations in the three components of the field. A coordinate system is devised which shows that the Venus data is indicative of the presence of flux ropes whose parameters are the coordinates of the system and would yield the excursions observed in the spacecraft crossings of the fields.

Elphic, R. C.↗

Low-latitude particle precipitation and associated local magnetic disturbances

The paper investigates the O(+) ion and NO(+) ion temperature and temperature anisotropy for a spatially homogeneous auroral F region in the presence of large electric fields perpendicular to the geomagnetic field. The maximum optical emissions at midlatitudes occur in concert with the maximum positive (northward) excursions in the H trace and with rapid fluctuations in the D trace of nearby magnetograms. The source of the particles is inferred to be the ring current, with precipitation occurring when the Dst index is large at the time of the large short-term excursions in the local magnetic field. This result is consistent with the finding of Voss and Smith (1979), derived from a series of rocket measurements of precipitating heavy particles, that the flux correlates better with the product of Dst and the exponential of Kp than with either alone. It is shown that the product of Dst and the amplitude of the short-term excursions in the horizontal component in local magnetograms has better time resolution and better correlation with the observed emission rates than the index using Kp.

Rassoul, H. K.↗

Space Station requirements and transportation options for lunar outpost

Preliminary design studies conducted by NASA are summarized which determined the requirements of the Space Station Freedom and transportation options for the establishment of a lunar outpost. Three phases are defined - emplacement, consolidation, and utilization - to describe the gradual development of the outpost. The lunar transportation system is based on the use of an earth-to-orbit and an LEO-lunar surface system for moving vehicles, propellant, crew, and cargo to the outpost. The vehicle-design and size requirements are defined for the reusable lunar-transfer vehicle and the lunar-excursion vehicle. Space Station Freedom is established as the LEO transportation node which transfers the required payloads to the excursion spacecraft following a 300-km low lunar orbit. The proposed lunar excursion vehicle is theorized to be capable of delivering 33 tons of cargo to the surface of the moon in the cargo-expendable mode.

Young, Archie C.↗

A late Devonian impact event and its association with a possible extinction event on Eastern Gondwana

Evidence from South China and Western Australia for a 365-Ma impact event in the Lower crepida conodont zone of the Famennian stage of the Late Devonian (about 1.5 Ma after the Frasnian/Famennian extinction event) includes microtektitelike glassy microspherules, geochemical anomalies (including a weak Ir), a probable impact crater (greater than 70 k) at Taihu in South China, and an Ir anomaly in Western Australia. A brachiopod faunal turnover in South China, and the 'strangelove ocean'-like c-delta 13 excursions in both Chinese and Australian sections indicate that at least a regional-scale extinction might have occurred at the time of the impact. A paleoreconstruction shows that South China was very close to and facing Western Australia in the Late Devonian. The carbon isotopic excursions, which occur at the same stratigraphic level in both South China and Western Australia cannot be explained as being coincidental. The c-delta 13 excursions and the brachiopod faunal turnover in South China indicate that there might have been at least a regional (possibly global) extinction in the Lower crepida zone. The impact-derived microspherules and geochemical anomalies (especially the Ir) indicate a Lower crepida zone impact event on eastern Gondwana. The location, type of target rocks, and possibly age of the Taihu Lake crater qualify as the probable site of this Late Devonian impact.

Wang, K.↗

Thermal investigation of a large lunar telescope

Recent interest in construction of a large telescope on the lunar surface (Nein and Davis, 1991; Bely, Burrows, and Illingworth, 1989) has prompted this feasibility study of a thermal control system for a 16 meter diameter telescope located near the lunar equator. In addition to detailed analyses for a telescope located in a flat area near the equator, the thermal effect of locating the telescope in a crater, on a hill, and at higher latitude sites is discussed. Because an unprotected telescope experiences a wide range of temperature swings, several thermal protection schemes have been examined, including domes, sunshades, and ground shields to limit the temperature excursions of the primary mirror. Results of these analyses indicate that mirror temperature excursions can be limited to less than 100 Kelvin (K) per lunar cycle with an appropriate passive thermal protection system (dome), and that the telescope primary mirror can be maintained at less than 100 K for at least 7 days of each lunar cycle. However, such a dome precludes observations during the lunar day. Mirror temperature excursions can be reduced by incorporating thermal enclosures or shades in the design or by placing the telescope at a higher latitude.

Walker, Sherry T.↗

Aeroelastic airfoil smart spar

Aircraft wings and rotor-blades are subject to undesirable bending and twisting excursions that arise from unsteady aerodynamic forces during high speed flight, abrupt maneuvers, or hard landings. These bending excursions can range in amplitude from wing-tip flutter to failure. A continuous-filament construction 'smart' laminated composite box-beam spar is described which corrects itself when subject to undesirable bending excursions or flutter. The load-bearing spar is constructed so that any tendency for the wing or rotor-blade to bend from its normal position is met by opposite twisting of the spar to restore the wing to its normal position. Experimental and theoretical characterization of these spars was made to evaluate the torsion-flexure coupling associated with symmetric lay-ups. The materials used were uniweave AS-4 graphite and a matrix comprised of Shell 8132 resin and U-40 hardener. Experimental tests were conducted on five spars to determine spar twist and bend as a function of load for 0, 17, 30, 45 and 60 deg fiber angle lay-ups. Symmetric fiber lay-ups do exhibit torsion-flexure couplings. Predictions of the twist and bend versus load were made for different fiber orientations in laminated spars using a spline function structural analysis. The analytical results were compared with experimental results for validation. Excellent correlation between experimental and analytical values was found.

Greenhalgh, Skott↗