Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ERROR SIGNAL”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

The POLARBEAR Fourier transform spectrometer calibrator and spectroscopic characterization of the POLARBEAR instrument

Here we describe the Fourier Transform Spectrometer (FTS) used for in-field testing of the POLARBEAR receiver, an experiment located in the Atacama Desert of Chile which measures the cosmic microwave background (CMB) polarization. The POLARBEAR-FTS (PB-FTS) is a Martin-Puplett interferometer designed to couple to the Huan Tran Telescope (HTT) on which the POLARBEAR receiver is installed. The PB-FTS measured the spectral response of the POLARBEAR receiver with signal-to-noise ratio >20 for ~69% of the focal plane detectors due to three features: a high throughput of 15.1 sr cm 2 , optimized optical coupling to the POLARBEAR optics using a custom designed output parabolic mirror, and a continuously modulated output polarizer. The PB-FTS parabolic mirror is designed to mimic the shape of the 2.5 m-diameter HTT primary reflector, which allows for optimum optical coupling to the POLARBEAR receiver, reducing aberrations and systematics. One polarizing grid is placed at the output of the PB-FTS and modulated via continuous rotation. This modulation allows for decomposition of the signal into different harmonics that can be used to probe potentially pernicious sources of systematic error in a polarization-sensitive instrument. The high throughput and continuous output polarizer modulation features are unique compared to other FTS calibrators used in the CMB field. In-field characterization of the POLARBEAR receiver was accomplished using the PB-FTS in April 2014. We discuss the design, construction, and operation of the PB-FTS and present the spectral characterization of the POLARBEAR receiver. We introduce future applications for the PB-FTS in the next-generation CMB experiment, the Simons Array.

47 OTHER INSTRUMENTATION↗

Optimization of foreground moment deprojection for semi-blind CMB polarization reconstruction

Abstract Upcoming Cosmic Microwave Background (CMB) experiments, aimed at measuring primordial CMB polarization B-modes, require exquisite control of instrumental systematics and Galactic foreground contamination. Blind minimum-variance techniques, like the Needlet Internal Linear Combination (NILC), have proven effective in reconstructing the CMB polarization signal and mitigating foregrounds and systematics across diverse sky models without suffering from foreground mismodelling errors. Still, residual foreground contamination from NILC may bias the recovered CMB polarization at large angular scales when confronted with the most complex foreground scenarios.By adding constraints to NILC to deproject statistical moments of the Galactic emission, the Constrained Moment ILC (cMILC) method has been demonstrated to further enhance foreground subtraction, albeit with an associated increase in overall noise variance. Faced with this trade-off between foreground bias reduction and overall variance minimization, there is still no recipe on which moments to deproject and which are better suited for blind variance minimization. To address this, we introduce the optimized cMILC (ocMILC) pipeline, which performs full automated optimization of the required number and set of foreground moments to deproject, pivot parameter values, and deprojection coefficients across the sky and angular scales, depending on the actual sky complexity, available frequency coverage, and experiment sensitivity. The optimal number of moments for deprojection, before paying significant noise penalty, is determined through a data diagnosis inspired by the Generalized NILC (GNILC) method.Validated on B-mode simulations of thePICOspace mission concept with four challenging foreground models, ocMILC exhibits lower Galactic foreground contamination compared to NILC and cMILC at all angular scales, with limited noise penalty. This multi-layer optimization enables the ocMILC pipeline to achieve unbiased posteriors of the tensor-to-scalar ratio, regardless of foreground complexity.

Astronomy & Astrophysics↗

Rapid monitoring of fermentations: a feasibility study on biological 2,3-butanediol production

2,3-butanediol (2,3-BDO) is an economically important platform chemical that can be produced by the fermentation of sugars using an engineered strain of Zymomonas mobilis . These fermentations require continuous monitoring and modification of fermentation conditions to maximize 2,3-BDO yields and minimize the production of the undesired coproducts glycerol and acetoin. Because of the time required for sampling and off-line chromatographic measurement of fermentation samples, the ability of fermentation scientists to modify fermentation conditions in a timely manner is limited. The goal of this study was to test if near-infrared spectroscopy (NIRS) along with multivariate statistics could reduce the time needed for this analysis and enable real-time monitoring and control of the fermentation. In this work we developed partial least squares (PLS) calibration models to predict the concentrations of glucose, xylose, 2,3-BDO, acetoin, and glycerol in fermentations via NIRS using two different spectrometers and two different spectroscopy modalities. We first evaluated the feasibility of rapid NIRS monitoring through experiments where we measured the signals from each analyte of interest and built NIRS-based PLS models using spectra from synthetic samples containing uncorrelated concentrations of these analytes. All analytes showed unique spectral signatures, and this initial modeling showed that all analytes could be detected simultaneously. We then began work with samples from laboratory fermentation experiments and tested the feasibility of regression model development across two spectral collection modalities (at-line and on-line) and two instruments: a laboratory-grade instrument and a low-cost instrument with a more limited spectral range. All modalities showed promise in the ability to monitor Z. mobilis fermentations of glucose and xylose to 2,3-BDO. The low-cost instrument displayed a lower signal-to-noise ratio than the laboratory-grade instrument, which led to comparatively lower performance overall, but still provided sufficient accuracy to monitor fermentation trends. While the ease of use of on-line monitoring systems was favored as compared to at-line systems due to the lack of sampling required and potential for automated process control, we observed some decrease in performance due to the additional complexity of the sample matrix. We have demonstrated that NIRS combined with multivariate analysis can be used for at-line and on-line monitoring of the concentrations of glucose, xylose, 2,3-BDO, acetoin, and glycerol during Z. mobilis fermentations. The decrease in signal-to-noise ratio when using a low-cost spectrometer led to greater prediction error than the laboratory-grade spectrometer for at-line monitoring. The on-line monitoring modality showed great promise for real time process control via NIRS.

09 BIOMASS FUELS↗

Evaluation of MOPITT Version 7 joint TIR–NIR X CO retrievals with TCCON

Observations of carbon monoxide (CO) from the Measurements Of Pollution In The Troposphere (MOPITT) instrument aboard the Terra spacecraft were expected to have an accuracy of 10 % prior to the launch in 1999. Here we evaluate MOPITT Version 7 joint (V7J) thermal-infrared and near-infrared (TIR–NIR) retrieval accuracy and precision and suggest ways to further improve the accuracy of the observations. We take five steps involving filtering or bias corrections to reduce scatter and bias in the data relative to other MOPITT soundings and ground-based measurements. (1) We apply a preliminary filtering scheme in which measurements over snow and ice are removed. (2) We find a systematic pairwise bias among the four MOPITT along-track detectors (pixels) on the order of 3–4 ppb with a small temporal trend, which we remove on a global scale using a temporally trended bias correction. (3) Using a small-region approximation (SRA), a new filtering scheme is developed and applied based on additional quality indicators such as the signal-to-noise ratio (SNR). After applying these new filters, the root-mean-squared error computed using the local median from the SRA over 16 years of global observations decreases from 3.84 to 2.55 ppb. (4) We also use the SRA to find variability in MOPITT retrieval anomalies that relates to retrieval parameters. We apply a bias correction to one parameter from this analysis. (5) After applying the previous bias corrections and filtering, we compare the MOPITT results with the GGG2014 ground-based Total Carbon Column Observing Network (TCCON) observations to obtain an overall global bias correction. These comparisons show that MOPITT V7J is biased high by about 6 %–8 %, which is similar to past studies using independent validation datasets on V6J. When using TCCON spectrometric column retrievals without the standard airmass correction or scaling to aircraft (WMO scale), the ground- and satellite-based observations overall agree to better than 0.5 %. GEOS-Chem data assimilations are used to estimate the influence of filtering and scaling to TCCON on global CO and tend to pull concentrations away from the prior fluxes and closer to the truth. We conclude with suggestions for further improving the MOPITT data products.

Hedelius, Jacob K. (ORCID:0000000320257519)↗

Timestamp Error Detection and Estimation for PMU Data based on Linear Correlation between Relative Phase Angle and Frequency

Time synchronization is essential to synchro-phasor-based applications. However, Timestamp Error (TE) in synchrophasor data can result in application failures. This paper proposes a method for TE detection based on the linear correlation between frequency and relative phase angle. The TE converts the short-term relative phase angle from noise-like signal to one that linear with the frequency. Pearson Correlation Coefficient (PCC) is applied to measure the linear correlation and then detect the timestamp error. The time error is estimated based on the variation of frequency and relative phase angle. Case studies with actual synchrophasor data demonstrate the effectiveness of TE detection and excellent accuracy of TE estimation.

Yu, Wenpeng↗

Complex deuteron NMR signals

To determine the spin polarization of deuterons, nuclear magnetic resonance (NMR) is used. This is necessary for polarized targets, such as for the upcoming A zz and b 1 experiment at Jefferson Lab. NMR measures the impedance of a solenoid around a deuterated sample. Although the impedance is a complex value, conventionally only the real part of the impedance has been used for this purpose. However, often the tune is not precisely real, meaning the signal has at least some small imaginary portion. This conventionally has been dealt with by an offset parameter, such as Dulya’s false asymmetry method. For vector polarization, this suffices, as the tuning is factored into the overall error of the results, and for a small phase angle doesn’t make much of a difference. However, for tensor polarization, the exact lineshape of the signal is quite significant, and treating the impedance as complex during analysis removes the need for an offset parameter. As a result, it also provides more accurate results, as the conventional false asymmetry method over- or underestimates polarization, depending on the sign of the phase angle.

McClellan, Michael [University of New Hampshire, D↗

Commissioning of SRF Cavity Analyzer System

Research and development in Superconducting Radio Frequency (SRF) cavities manufacturing, surface treatment, preparation, and doping techniques for the improvement of cavities performance necessitate reliable cavities’ intrinsic quality factor measurement with accurate and repeatable results. Fermilab Vertical Test Stand facility (VTS) performs ~270 cavities tests per year, including R&D cavities as well as production cavities at each step of their preparation for the placement in accelerator’s cryomodules. Current Fermilab VTS testing system is based on the scalar approach of power measurement, which neglects potential error factors of the RF networks with distributed parameters, hence the assessed measurement errors of such a system might be slightly underestimated. Alternative approach, utilizing a vector measurement (amplitude and phase) of RF signals in the setup with a cavity as a device under test, promises an enhanced accuracy and results traceability. New cavity an alyser system based on this approach (Vector VTS) was developed by D. Frolov et al. and currently undergoes a commissioning process. Basic underlying principles of the system will be presented with the methods of quality factor extraction from S-parameters measurement of multiport cavities and brief error analysis will be discussed. The system architecture will be shown with main components parameters and ensuing testing capabilities. Multiple tests results will be discussed with a cross-check comparison of the results obtained with a conventional testing method. System advantages such as automated calibration process and additional features as a built- in microphonics measurement capability will be presented.

Netepenko, A.↗

Nonlinear signal distortion corrections through quantum sensing

Having accurate gate generation is essential for precise control of a quantum system. The generated gate usually suffers from linear and nonlinear distortion. Previous works have demonstrated how to use a qubit to correct linear frequency distortions but have not commented on how to handle nonlinear distortions. This is an important issue as we show that nonlinear amplitude distortions from the RF electronics can affect Rabi pulses by as much as 10%. We present work that demonstrates how a transmon qubit can be used as a highly sensitive cryogenic detector to characterize these nonlinear amplitude distortions. We show that a correction can drive these errors down to <1% over a 700 MHz range. The correction technique provides a method to minimize the effects of signal distortions and can be easily applied to broadband control pulses to produce higher fidelity arbitrary quantum gates.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Resilient State Recovery Using Prior Measurement Support Information

Resilient state recovery of cyber-physical systems has attracted much research attention due to the unique challenges posed by the tight coupling between communication, computation, and the underlying physics of such systems. By modeling attacks as additive adversary signals to a sparse subset of measurements, this resilient recovery problem can be formulated as an error correction problem. To achieve exact state recovery, most existing results require less than 50% of the measurement nodes to be compromised, which limits the resiliency of the estimators. In this paper, we show that observer resiliency can be further improved by incorporating data-driven prior information. Here, we provide an analytical bridge between the precision of prior information and the resiliency of the estimator. By quantifying the relationship between the estimation error of the weighted ℓ 1 observer and the precision of the support prior, this quantified relationship provides guidance for the estimator’s weight design to achieve optimal resiliency. Several numerical simulations and an application case study are presented to validate the theoretical claims.

24 POWER TRANSMISSION AND DISTRIBUTION↗

An Extreme-precision Radial-velocity Pipeline: First Radial Velocities from EXPRES

The EXtreme-PREcision Spectrograph (EXPRES) is an environmentally stabilized, fiber-fed, R = 137,500, optical spectrograph. It was recently commissioned at the 4.3 m Lowell Discovery Telescope near Flagstaff, Arizona. The spectrograph was designed with a target radial-velocity (RV) precision of 30 cm s{sup −1}. In addition to instrumental innovations, the EXPRES pipeline, presented here, is the first on-sky, optical, fiber-fed spectrograph to employ many novel techniques—including an “extended flat” fiber used for wavelength-dependent quantum efficiency characterization of the CCD, a flat-relative optimal extraction algorithm, chromatic barycentric corrections, chromatic calibration offsets, and an ultra-precise laser frequency comb for wavelength calibration. We describe the reduction, calibration, and RV analysis pipeline used for EXPRES and present an example of our current sub-meter-per-second RV measurement precision, which reaches a formal, single-measurement error of 0.3 m s{sup −1} for an observation with a per-pixel signal-to-noise ratio of 250. These velocities yield an orbital solution on the known exoplanet host 51 Peg that matches literature values with a residual rms of 0.895 m s{sup −1}.

79 ASTRONOMY AND ASTROPHYSICS↗

Quantitative assessment of fitting errors associated with streak camera noise in Thomson scattering data analysis

Thomson scattering measurements in high energy density experiments are often recorded using optical streak cameras. In the low-signal regime, noise introduced by the streak camera can become an important and sometimes the dominant source of measurement uncertainty. In this paper, we present a formal method of accounting for the presence of streak camera noise in our measurements. We present a phenomenological description of the noise generation mechanisms and present a statistical model that may be used to construct the covariance matrix associated with a given measurement. This model is benchmarked against simulations of streak camera images. We demonstrate how this covariance may then be used to weight fitting of the data and provide quantitative assessments of the uncertainty in the fitting parameters determined by the best fit to the data and build confidence in the ability to make statistically significant measurements in the low-signal regime, where spatial correlations in the noise become apparent. These methods will have general applicability to other measurements made using optical streak cameras.

47 OTHER INSTRUMENTATION↗

Conversion of METL Diagnostic Flowmeters to Permanent Magnet Based Electromagnetic Flowmeters

The Mechanisms Engineering Test Loop (METL) uses three flowmeters to monitor sodium circulation through the main loop, the Cold Trap leg, and the Plugging Meter leg. When constructed, the Cold Trap flowmeter (CTFM) and Plugging Meter flowmeter (PMFM) were equipped with permanent magnets and Hall Sensors. By October of 2019, during normal operations, both the CTFM and PMFM failed, producing either erroneous or zero signals. Repairs to the flowmeters were attempted in January of 2020 but failed to resolve the issues. Therefore, starting in March of 2021, a plan was developed to convert the installed flowmeters to more robust permanent magnet based electromagnetic flowmeters (EMFMs). The Cold Trap EMFM (CT EMFM) and Plugging Meter EMFM (PM EMFM) were fully installed by August of 2021. Initial testing and commissioning were completed in November of 2021. Finally, the first calibration runs were finished in March of 2022. This report discusses the design, conversion, and calibration of the as-built CTFM and PMFM to robust permanent magnet based EMFMs. During the design phase, theoretical models were used to estimate the signal output and required magnet sizes. Then, the CTFM and PMFM were disassembled and converted to EMFMs. After commissioning, the CT EMFM and PM EMFM were calibrated using a ‘Time Transfer Procedure’ carried out with METL Expansion Vessels and Test Vessel Two. The accuracy of the calibration was estimated through an uncertainty analysis. Finally, the report describes some lessons learned for future flowmeter conversions and follow-up work. In total, both METL EMFM’s met the desired performance targets. Testing data showed that the METL EMFMs provide a output signal of roughly 2 mV at 1 GPM and 250 °C. During calibration, flowrates between 0.7 GPM and 2.4 GPM were achieved. In this flow range, calibration coefficients of 0.485 and 0.935 were measured as with errors ranging from 15-5% and 16-5% for the CT EMFM and PM EMFM, respectively. Above 1.5 GPM, the error was assumed to be about 5% for both METL EMFMs. Several points will be considered for future follow-up work on the METL EMFM’s. First, the signal noise issues in the PM EMFM will be addressed. It is likely the source of the noise is due to some stray EMF from a heater. Secondly, the NdFeB magnets will be replaced with a grade that has a Curie temperature above 80 °C. For example, a few grades of NeFeB magnets have Curie temperatures which exceed 150 °C and some SmCo magnets have Curie temperatures as high as 500 °C. Third, more calibration runs will be completed in the range of 0.5-2.5 GPM. This will further improve the accuracy of the calibration coefficient. Fourth, calibration runs will be completed up to 5 GPM. This requires a larger pressure relief valve to be installed on the Expansion Vessel and Test Vessel 2, as well as a revised calibration procedure. Lastly, calibration runs will be completed to account for cold spots in the system, which reduced the inlet temperature of the METL EMFMs. Overall, these points will improve the calibration coefficients derived in this work and also improve the performance of the METL EMFMs.

42 ENGINEERING↗

EXPRES. II. Searching for Planets around Active Stars: A Case Study of HD 101501

By controlling instrumental errors to below 10 cm s{sup −1}, the EXtreme PREcision Spectrograph (EXPRES) allows for a more insightful study of photospheric velocities that can mask weak Keplerian signals. Gaussian processes (GP) have become a standard tool for modeling correlated noise in radial velocity data sets. While GPs are constrained and motivated by physical properties of the star, in some cases they are still flexible enough to absorb unresolved Keplerian signals. We apply GP regression to EXPRES radial velocity measurements of the 3.5 Gyr old chromospherically active Sun-like star, HD 101501. We obtain tight constraints on the stellar rotation period and the evolution of spot distributions using 28 seasons of ground-based photometry, as well as recent Transiting Exoplanet Survey Satellite data. Light-curve inversion was carried out on both photometry data sets to reveal the spot distribution and spot evolution timescales on the star. We find that the >5 m s{sup −1} rms radial velocity variations in HD 101501 are well modeled with a GP stellar activity model without planets, yielding a residual rms scatter of 45 cm s{sup −1}. We carry out simulations, injecting and recovering signals with the GP framework, to demonstrate that high-cadence observations are required to use GPs most efficiently to detect low-mass planets around active stars like HD 101501. Sparse sampling prevents GPs from learning the correlated noise structure and can allow it to absorb prospective Keplerian signals. We quantify the moderate to high-cadence monitoring that provides the necessary information to disentangle photospheric features using GPs and to detect planets around active stars.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optimizing time integration for accurate recovery of shockwave interface location in radiography

We present simulations and experiments of time integrated radiographic imaging of a moving 1D shock wave front and a quantitative method for determining the statistical error in locating the shock front as a function of integration time and noise in the radiograph. We discuss the trade-off between increasing motion blur, which leads to decreased shock front location certainty, and increasing signal-to-noise, which leads to improved image quality with increasing integration time. We find an optimum integration time between a short integration time, where noise limits the error, and a long integration time, where motion blurring limits the error. This methodology can be used to tune experimental configurations to obtain the highest quality radiograph for a given experimental configuration.

Bremsstrahlung↗

Stochastic Optimization and Uncertainty Quantification of Natrium-based Nuclear-Renewable Energy Systems for Flexible Power Applications in Deregulated Markets

Rapid integration of variable renewable energy sources (VRES) has made modeling and stochastic optimization of hybrid energy systems crucial for studying their long-term performance and viability. However, most studies have focused on just historical data, which may be unreliable for capturing short-term fluctuations, rare events, and long-term patterns of energy demand, price, and the variability of renewable energy sources. For this study, optimal synthetic time series models were developed using Wasserstein distance. The models were validated by comparing the key statistical measures against those of the historical data. They were then used to optimize the integrated Natrium-style advanced energy systems and their long-term (30 years) economics. The stochastic model performs bi-level optimization to find the optimal sizes for the balance of plant and thermal energy storage, while also optimizing energy dispatch to achieve the maximum net present value. In studies of two deregulated markets (California ISO and the Electric Reliability Council of Texas), the integrated Natrium-style system performed better in CAISO than in ERCOT, given higher and more consistent electricity prices during peak-demand periods. The potentially enlarged cost associated with the variable operation and maintenance of the TES system also plays a significant role in driving the system sizing, thus its impacts on the system are investigated in detail through comparison against a baseline case. The study also finds that the bi-level optimization results based on stochastic gradient descent closely match the grid search results. The uncertainty quantification of the stochastic signals provides further NPV-related insights and probability distributions for the case studies. The normal standard error of the mean of NPV for the case with and without TES VOM for CAISO were found to be 7.73M (plus-minus sign) 1.09M USD and 104.99M (plus-minus sign) 1.25M USD, respectively based on a 95% confidence. Given the relatively small NPV variance based on 150 samples, the analysis affords the most robust possible prediction of the techno-economic performance of the integrated Natrium-style energy systems.

25 ENERGY STORAGE↗

Electron shelving of a superconducting artificial atom

Interfacing long-lived qubits with propagating photons is a fundamental challenge in quantum technology. Cavity and circuit quantum electrodynamics (cQED) architectures rely on an off-resonant cavity, which blocks the qubit emission and enables a quantum non-demolition (QND) dispersive readout. However, no such buffer mode is necessary for controlling a large class of three-level systems that combine a metastable qubit transition with a bright cycling transition, using the electron shelving effect. Here we demonstrate shelving of a circuit atom, fluxonium, placed inside a microwave waveguide. With no cavity modes in the setup, the qubit coherence time exceeds 50 μs, and the cycling transition’s radiative lifetime is under 100 ns. By detecting a homodyne fluorescence signal from the cycling transition, we implement a QND readout of the qubit and account for readout errors using a minimal optical pumping model. Our result establishes a resource-efficient (cavityless) alternative to cQED for controlling superconducting qubits.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Lensing without borders – I. A blind comparison of the amplitude of galaxy–galaxy lensing between independent imaging surveys

ABSTRACT Lensing without borders is a cross-survey collaboration created to assess the consistency of galaxy–galaxy lensing signals (ΔΣ) across different data sets and to carry out end-to-end tests of systematic errors. We perform a blind comparison of the amplitude of ΔΣ using lens samples from BOSS and six independent lensing surveys. We find good agreement between empirically estimated and reported systematic errors which agree to better than 2.3σ in four lens bins and three radial ranges. For lenses with zL > 0.43 and considering statistical errors, we detect a 3–4σ correlation between lensing amplitude and survey depth. This correlation could arise from the increasing impact at higher redshift of unrecognized galaxy blends on shear calibration and imperfections in photometric redshift calibration. At zL > 0.54, amplitudes may additionally correlate with foreground stellar density. The amplitude of these trends is within survey-defined systematic error budgets that are designed to include known shear and redshift calibration uncertainty. Using a fully empirical and conservative method, we do not find evidence for large unknown systematics. Systematic errors greater than 15 per cent (25 per cent) ruled out in three lens bins at 68 per cent (95 per cent) confidence at z < 0.54. Differences with respect to predictions based on clustering are observed to be at the 20–30 per cent level. Our results therefore suggest that lensing systematics alone are unlikely to fully explain the ‘lensing is low’ effect at z < 0.54. This analysis demonstrates the power of cross-survey comparisons and provides a promising path for identifying and reducing systematics in future lensing analyses.

79 ASTRONOMY AND ASTROPHYSICS↗

The stellar parameters and elemental abundances from low-resolution spectra – I. 1.2 million giants from LAMOST DR8

As a typical data-driven method, deep learning becomes a natural choice for analysing astronomical data. In this study, we built a deep convolutional neural network (NN) to estimate basic stellar parameters $T\rm {_{eff}}$, log g , metallicity ([M/H] and [Fe/H]) and [α/M] along with nine individual elemental abundances ([C/Fe], [N/Fe], [O/Fe], [Mg/Fe], [Al/Fe], [Si/Fe], [Ca/Fe], [Mn/Fe], and [Ni/Fe]). The NN is trained using common stars between the APOGEE survey and the LAMOST survey. We used low-resolution spectra from LAMOST survey as input, and measurements from APOGEE as labels. For stellar spectra with the signal-to-noise ratio in g band larger than 10 in the test set, the mean absolute error (MAE) is 29 K for $T\rm {_{eff}}$, 0.07 dex for log g , 0.03 dex for both [Fe/H] and [M/H], and 0.02 dex for [α/M]. The MAE of most elements is between 0.02 and 0.04 dex. The trained NN was applied to 1210 145 giants, including sub-giants, from LAMOST DR8 within the range of stellar parameters 3500 K < $T\rm {_{eff}}$ < 5500 K, 0.0 dex < log g < 4.0 dex, −2.5 dex < [Fe/H] < 0.5 dex. The distribution of our results in the chemical spaces is highly consistent with APOGEE labels and stellar parameters show consistency with external high-resolution measurements from GALAH. The results in this study allow us to further studies based on LAMOST data and deepen our understanding of the accretion and evolution history of the Milky Way. The electronic version of the value added catalog is available at http://www.lamost.org/dr8/v1.1/doc/vac.

79 ASTRONOMY AND ASTROPHYSICS↗