Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ENERGY RANGE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Measurement of the U 235 ( n , f ) prompt fission neutron spectrum from 10 keV to 10 MeV induced by neutrons of energy from 1 MeV to 20 MeV

The characterization of fission-driven nuclear systems primarily relies on calculations of neutron-induced chain reactions, and these calculations require evaluated nuclear data as input. Calculation accuracy heavily depends on input nuclear data evaluation accuracy, and thus high precision on the experimental input to the nuclear data evaluation is essential for fundamental quantities like the energy spectrum of neutrons emitted from neutron-induced fission (i.e., the prompt fission neutron spectrum, PFNS). Despite decades of measurement efforts, prior to the measurements described in this work there were only three literature data sets for the 235 U(n,f) PFNS at incident neutron energies above 1.0 MeV considered reliable for inclusion in nuclear data evaluations and no reliable data sets above 3.0 MeV incident neutron energy. In this work we report on new measurements of the 235 U(n,f) PFNS spanning a grid of 1.0–20.0 MeV in incident neutron energy and 0.01–10.0 MeV in outgoing (PFNS) neutron energy. These measurements were carried out at the Weapons Neutron Research facility at the Los Alamos Neutron Science Center and used a multifoil parallel-plate avalanche counter target with both a Li-glass and a liquid scintillator detector array in separate experiments to span the quoted outgoing neutron energy ranges. The PFNS results are shown in terms of the energy spectra themselves as well as the average PFNS energy $(\langle{E}\rangle)$ and ratios of $\langle{E}\rangle$ at forward and backward angles. Here, the results are compared with literature data and selected nuclear data evaluations. Generally, the data agree with the ENDF/B-VIII.0 evaluation below 5.0-MeV incident neutron energy and more closely with the JEFF-3.3 evaluation above 5.0 MeV, though no evaluations considered for comparison in this work agree with the data across all of the incident and outgoing neutron energies shown, especially in regions where the third-chance fission process becomes available. Additionally, we show a ratio of the present PFNS results for 235 U(n, f) with a recent and highly correlated experiment to measure the 239 Pu(n, f) PFNS at the same experimental facility and with nearly identical equipment and analysis procedures. Many observations reported in this work are the first of their kind and represent significant advancements for knowledge of the 235 U(n, f) PFNS.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Energy dependence of prompt fissions neutron multiplicity in the 239 Pu(n, ƒ) reaction

Accurate multiplicities of prompt fission neutrons emitted in neutron-induced fission on a large energy range are essential for fundamental and applied nuclear physics. Measuring them to high precision for radioactive fissioning nuclides remains, however, an experimental challenge. In this work, the average prompt-neutron multiplicity emitted in the 239 Pu(n, ƒ) reaction was extracted as a function of the incident-neutron energy, over the range 1-700 MeV, with a novel technique, which allowed to minimize and correct for the main sources of bias and thus achieve unprecedented precision. At low energies, our data validate for the first time the ENDF/B-VIII.0 nuclear data evaluation with an independent measurement and reduce the evaluated uncertainty by up to 60%. This work opens up the possibility of precisely measuring prompt fission neutron multiplicities on highly radioactive nuclei relevant for an essential component of energy production world-wide.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement of $$ {e}^{+}{e}^{-}\to p{K}^{-}\overline{\Lambda}+c.c. $$ cross sections between 4.009 GeV and 4.951 GeV

Abstract Usinge + e − collision datasets corresponding to a total integrated luminosity of 21.7 fb −1 collected with the BESIII detector at the BEPCII collider at center-of-mass energies ranging from 4.009 GeV to 4.951 GeV, the energy-dependent cross sections of$$ {e}^{+}{e}^{-}\to p{K}^{-}\overline{\Lambda}+c.c. $$ e + e − → p K − Λ ¯ + c . c . are measured for the first time. By fitting these energy-dependent cross sections, we search for the excitedψstatesψ(4160) andψ(4415), and the vector charmonium-like statesψ(4230),ψ(4360), andψ(4660). No evidence for these is observed and the upper limits on the branching fractions of these states decaying into$$ p{K}^{-}\overline{\Lambda}+c.c. $$ p K − Λ ¯ + c . c . are set at the 90% confidence level.

Physics↗

Nonradiative relaxation dynamics in the [Au 25- n Ag n (SH) 18 ] -1 ( n = 1, 12, 25) thiolate-protected nanoclusters

Evaluation of the electron-nuclear dynamics and relaxation mechanisms of gold and silver nanoclusters and their alloys is important for future photocatalytic, light harvesting, and photoluminescence applications of these systems. In this work, the effect of silver doping on the nonradiative excited state relaxation dynamics of the atomically precise thiolate-protected gold nanocluster [Au 25- n Ag n (SH) 18 ] –1 ( n = 1, 12, 25) is studied theoretically. Time-dependent density functional theory is used to study excited states lying in the energy range 0.0–2.5 eV. The fewest switches surface hopping method with decoherence correction was used to investigate the dynamics of these states. The HOMO–LUMO gap increases significantly upon doping of 12 silver atoms but decreases for the pure silver nanocluster. Doped clusters show a different response for ground state population increase lifetimes and excited state population decay times in comparison to the undoped system. The ground state recovery times of the S 1 –S 6 states in the first excited peak were found to be longer for [Au 13 Ag 12 (SH) 18 ] –1 than the corresponding recovery times of other studied nanoclusters, suggesting that this partially doped nanocluster is best for preserving electrons in an excited state. The decay time constants were in the range of 2.0–20 ps for the six lowest energy excited states. Among the higher excited states, S 7 has the slowest decay time constant although it occurs more quickly than S 1 decay. Overall, these clusters follow common decay time constant trends and relaxation mechanisms due to the similarities in their electronic structures.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Development of a compact magnetic spectrometer for use at the OMEGA Laser Facility and the National Ignition Facility

Measurement of proton spectra is an important diagnostic for a variety of high energy density physics experiments. Current diagnostics are either not designed to capture the spectrum of low-energy protons or are unsuitable for high debris experiments. To bridge the gap, a new CR-39 based compact magnetic spectrometer (MagSpec) has been developed to measure proton spectra in the 1–20 MeV energy range, with a particular focus on the low-energy (1–6 MeV) spectrum, for use in experiments at the OMEGA Laser Facility and the National Ignition Facility (NIF). In the MagSpec diagnostic, protons of different energies are dispersed as they pass through a magnetic field before impinging on a differentially filtered CR-39 surface, resulting in a spatial distribution of CR-39 tracks that corresponds to the energy spectrum. In this paper, we discuss details of the design and implementation of MagSpec on the NIF and OMEGA.

47 OTHER INSTRUMENTATION↗

Response of a CMS HGCAL silicon-pad electromagnetic calorimeter prototype to 20–300 GeV positrons

The Compact Muon Solenoid collaboration is designing a new high-granularity endcap calorimeter, HGCAL, to be installed later this decade. As part of this development work, a prototype system was built, with an electromagnetic section consisting of 14 double-sided structures, providing 28 sampling layers. Each sampling layer has an hexagonal module, where a multipad large-area silicon sensor is glued between an electronics circuit board and a metal baseplate. The sensor pads of approximately 1.1 cm$^{2}$ are wire-bonded to the circuit board and are readout by custom integrated circuits. The prototype was extensively tested with beams at CERN's Super Proton Synchrotron in 2018. Based on the data collected with beams of positrons, with energies ranging from 20 to 300 GeV, measurements of the energy resolution and linearity, the position and angular resolutions, and the shower shapes are presented and compared to a detailed Geant4 simulation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design of an epithermal neutron velocity selection system for the Penn State Breazeale Reactor

A series of mechanical neutron choppers to operate as a velocity selection system have been developed for the Pennsylvania State Breazeal Reactor (PSBR). This chopper system will provide pulsed epithermal neutrons in the energy range of 0.5–40 eV with 2% or better energy resolution, and with a transmission of 1E-6 or better. Four different chopper geometries have been evaluated for their utility as mechanical neutron choppers. Specifically, Fermi, ring, piston, and disc choppers have been evaluated to assess their potential neutronics performance and mechanical constructability. A series of high-speed disc choppers were selected for the final design, and optimization work was performed to maximize the neutron pulse intensity. It is estimated that the optimized system will produce an epithermal neutron intensity of approximately 96 n/s. This system can also be operated in a time of flight (TOF) configuration such that the neutrons arriving at the source have a white spectrum. This operation can be accomplished by leaving the second stage of choppers in the open position, or by removing it from the beam completely. Such unique source of epithermal neutrons produced by this chopper system will have applications in both prompt and delayed epithermal neutron activation analysis (ENAA), as well as in neutron resonance transmission analysis (NRTA).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of the prompt fission neutron spectrum from 800 keV to 10 MeV for 240 Pu(sf) and for the 240 Pu($n,f$) reaction induced by neutrons of energy from 1–20 MeV

Here, the presence of 240 Pu in nuclear fuels for reactors has resulted in high uncertainties in the results of reactor and nuclear transmutation calculations because of deficiencies in 240 Pu-related nuclear data. Specifically for the prompt fission neutron spectrum (PFNS) of 240 Pu, there is only one neutron-induced, (n,f), measurement at 0.85 MeV incident neutron energy and only one complete spontaneous fission, (sf), measurement. This limited availability of data does not sufficiently guide nuclear data evaluations of these quantities. Here we report on a measurement of both the 240 Pu(sf) and the 240 Pu(n,f) PFNS, both over the emitted neutron energy range of 0.79–10.0 MeV, and from incident neutron energies of 1.0–20.0 MeV for the (n,f) reaction. Measurements were made with a hemispherical array of liquid scintillators at the high-energy Los Alamos Neutron Science Center white neutron source at the Weapons Neutron Research facility as part of the joint LANL-LLNL Chi-Nu experimental campaign to measure actinide fission neutron spectra. These measurements are the first of their kind, and provide clear experimental evidence for second-chance fission, third chance fission, and pre-equilibrium neutron emission processes in neutron-induced fission of 240 Pu, and are the first ever measurements above 1 MeV incident neutron energy.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Harmonic suppression gratings for soft X-ray monochromators

We describe an approach to harmonic suppression in soft X-ray monochromators by engineering the reflection grating’s diffraction pattern to approximate a sinusoidal amplitude. At synchrotron and free-electron laser sources, X-ray beamlines powered by insertion devices produce a spectrum containing harmonic photon energies that can couple unwanted light into experiments. Beamlines in the soft X-ray energy range (100 eV to 2 keV) commonly employ energy-filtering elements to suppress these harmonics. Available approaches tend to be inefficient, significantly reducing the transmitted power. We show that with pseudo-grayscale binary halftone patterns, gratings can approximate a sinusoidal amplitude and suppress higher diffraction orders. Prototype demonstrations of lithographically fabricated gratings were conducted on a soft X-ray beamline with photon energies of 110 eV and 330 eV. Relative to a square-wave amplitude grating, the third-harmonic intensity was reduced by a factor of 9.0 with a first-order efficiency reduction of 38%.

Goldberg, Kenneth A. [Lawrence Berkeley National L↗

Measurement of the Prompt Fission Neutron Spectrum from 800 keV to 10 MeV for 240 Pu($sf$) and for the 240 Pu($n,f$) Reaction Induced by Neutrons of Energy from 1-20 MeV

The presence of 240 Pu in nuclear fuels for reactors has resulted in high uncertainties in the results of reactor and nuclear transmutation calculations because of deficiencies in 240 Pu-related nuclear data. Specifically for the prompt fission neutron spectrum (PFNS) of 240 Pu, there is only one neutron-induced, ($n,f$), measurement at 0.85 MeV incident neutron energy and only one complete spontaneous fission, ($sf$), measurement. This limited availability of data does not sufficiently guide nuclear data evaluations of these quantities. Here we report on a measurement of both the 240 Pu($sf$) and the 240 Pu($n,f$) PFNS, both over the emitted neutron energy range of 0.79–10.0 MeV, and from incident neutron energies of 1.0–20.0 MeV for the ($n,f$) reaction. Measurements were made with a hemispherical array of liquid scintillators at the high-energy Los Alamos Neutron Science Center white neutron source at the Weapons Neutron Research facility as part of the joint LANL-LLNL Chi-Nu experimental campaign to measure actinide fission neutron spectra. These measurements are the first of their kind, and provide clear experimental evidence for second-chance fission, third-chance fission, and pre-equilibrium neutron emission processes in neutron-induced fission of 240 Pu, and are the first ever measurements above 1 MeV incident neutron energy.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Multi-energy calibration of a PILATUS3 CdTe detector for hard x-ray measurements of magnetically confined fusion plasmas

A multi-energy hard x-ray pin-hole camera based on the PILATUS3 X 100K-M CdTe detector has been developed at the Princeton Plasma Physics Laboratory for installation on the Tungsten Environment in Steady State Tokamak. This camera will be employed to study thermal plasma features such as electron temperature as well as non-thermal effects such as fast electron tails produced by a lower hybrid radiofrequency current drive and the birth of runaway electrons. The innovative aspect of the system lies in the possibility of setting the threshold energy independently for each of the ~100k pixels of the detector. This feature allows for the measurement of the x-ray emission in multiple energy ranges with adequate space and time resolution (~1 cm, 2 ms) and coarse energy resolution. In this work, the energy dependence of each pixel was calibrated within the range 15 keV–100 keV using a tungsten x-ray tube and emission from a variety of fluorescence targets (from yttrium to uranium). The data corresponding to pairs of K α emission lines are fit to the characteristic responsivity (“S-curve”), which describes the detector sensitivity across the 64 possible energy threshold values for each pixel; this novel capability is explored by fine-tuning the voltage of a six-bit digital-analog converter after the charge-sensitive amplifier for each of the ~100k pixels. Here, this work presents the results of the calibration including a statistical analysis. It was found that the achievable energy resolution is mainly limited by the width of the S-curve to 3 keV–10 keV for threshold energies up to 50 keV, and to ≥20 keV for energies above 60 keV.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Effects of a 4.3T superconducting wiggler on the electron beam optics and dynamics at NSLS-II

A superconducting wiggler (SCW) with a peak field of 4.3 T has recently been installed at NSLS-II. The wiggler generates a high-flux X-ray beam with a photon energy range from 20 keV to 200 keV for the High Energy Engineering X-ray Scattering beamline. This device induces significant distortions in the electron beam orbit and optics. Here, we have corrected these adverse effects using feed-forward tables. The effects of the SCW on the electron beam emittance, energy spread, and bunch length were calculated and measured. The beam-induced heating of the cryogenic vacuum chamber was also studied. Finally, the superconducting wiggler has been commissioned for user operations.

36 MATERIALS SCIENCE↗

Investigating Interference Term in DUNE And SBND Neutrino Interactions with ACHILLES

Understanding neutrino-nucleus interactions is critical for conducting precise neutrino oscillation ex- periments. However, uncertainties in neutrino-nucleus cross section measurements and our incomplete understanding of nuclear effects remain a significant challenge in neutrino physics. In this paper, we investigate contributions from quantum interference between one-body and two-body interactions in charged-current quasi-elastic (CCQE) neutrino scattering amplitudes, using the ACHILLES event gen- erator. Simulations are performed using muon neutrino flux from Fermilab’s Booster Neutrino Beam (BNB), as well as Long-Baseline Neutrino Facility (LBNF) flux. We observe the neutrino flux interact- ing with Argon nuclei as detected by the Short Baseline Near Detector (SBND) and DUNE Near Detector (DUNE-ND), both Liquid Argon Time Projection Chambers (LArTPC). We focus on one muon and one proton final states with cascade interactions. We analyze multiple experimental observables including outgoing kinematic variables, energy-momentum transfer variables, and Transverse Kinematic Imbalance (TKI) variables. In this study, we also investigate the effects of PRISM (a method of sampling flux from multiple off-axis angles which creates different neutrino energy spectra). We find that the ratio of in- terference to quasi-elastic contributions gives a non-flat distribution across a 0-3.5 GeV energy range, indicating that effects of interference vary with the neutrino energy sampled. Our ultimate goal is to reduce systematic uncertainties from neutrino interactions when conducting oscillation experiments by working to disentangle the effects of quantum interference from the quasi-elastic signature.

Serumaga, Peera [Fermilab; UC, San Diego] (ORCID:0↗

Superconductivity and strong correlations in moiré flat bands

Strongly correlated systems can give rise to spectacular phenomenology, from high-temperature superconductivity to the emergence of states of matter characterized by long-range quantum entanglement. Low-density flat-band systems play a vital role because the energy range of the band is so narrow that the Coulomb interactions dominate over kinetic energy, putting these materials in the strongly-correlated regime. Experimentally, when a band is narrow in both energy and momentum, its filling may be tuned in situ across the whole range, from empty to full. Recently, one particular flat-band system—that of van der Waals heterostructures, such as twisted bilayer graphene—has exhibited strongly correlated states and superconductivity, but it is still not clear to what extent the two are linked. As a result, we review the status and prospects for flat-band engineering in van der Waals heterostructures and explore how both phenomena emerge from the moiré flat bands.

Balents, Leon↗

Photon detector response function methodology using MCNP and shift hybrid radiation transport code for wide-area contamination assay applications

Here, radiation transport modeling using the Monte Carlo N-Particle (MCNP) radiation transport code and Monte Carlo code, Shift, were employed to model detector responses for a variety of wide-area photon contamination scenarios. In this study, 2" × 2" and 3" × 3" cylindrical NaI(Tl) scintillation detector configurations at source detector-distances of 0.5 cm, 1 cm, 2.54 cm, 10 cm, and 30 cm were modeled. Media of soil, concrete, and steel were evaluated for contamination depths ranging from surface to a depth of an infinite thickness in each medium for photon energies ranging from 20 keV to 3 MeV, which correspond to the energies that current detectors can discern. Monoenergetic photon surface contamination detector responses for each of the media, source–detector distances, and detectors were estimated using MCNP v6.2. Shift was harnessed for improved variance reduction of particle transport in highly attenuating media to obtain average cell fluxes in the two MCNP NaI(Tl) scintillation detector configurations. Average cell flux values in Shift were coupled with detector responses from MCNP to convert average cell flux in a void to energy distribution of pulses in the NaI(Tl) scintillation detector crystal of interest. An optimized detector response function methodology was developed by coupling the MCNP radiation transport method with the Consistent Adjoint Driven Importance Sampling (CADIS) hybrid radiation transport method built into Shift to significantly decrease the runtime of thousands of MCNP pulse height simulations. The methodology may be utilized to quickly and accurately facilitate the assessment of a broad range of wide-area environmental contamination assay and decommissioning cleanup applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Analysis of strain in ion implanted 4H-SiC by fringes observed in synchrotron X-ray topography

A novel high energy implantation system has been successfully developed to fabricate 4H-SiC superjunction devices for medium and high voltage via implantation of dopant atoms with multi-energies ranging from 13 to 66 MeV. The significantly higher levels of energy used compared to conventional implantation processes, necessitates detailed characterization of the lattice damage caused by implantation. To achieve this by employing the novel high energy system, 4H-SiC wafer with 12 μm epilayers were blanket implanted by 13.8–65.7 MeV Al atoms. The lattice damages induced by the implantation were primarily characterized by Synchrotron X-ray Plane Wave Topography (SXPWT) and Reciprocal Space Mapping (RSM). Topographs reveal fringe contrast akin to multiple asymmetric diffraction peaks with an angular separation of only 2″ (arcseconds) observed on rocking curves, indicating inhomogeneous strain distribution across the implanted layer. The strain profile of the implanted layer was extracted from the fringe contrast by applying Rocking-curve Analysis by Dynamical Simulation (RADS). In conclusion, the maximum strain value is similar to that measured on the RSM.

A1. Characterization↗

Multiple Coulomb scattering in acrylic of a 221.3 MeV therapeutic proton beam

Measurements of multiple Coulomb scattering (MCS) distributions for 221.3 MeV therapeutic protons are presented using a novel detector system comprised of a thin scintillator, a pellicle mirror, and a digital camera. The MCS distributions were characterized for three acrylic phantoms of varying lengths and for two biological density-equivalent phantoms simulating bone and muscle. Additionally, beam profiles were measured across an energy range of 80.3–221.3 MeV in 20 MeV increments. The observed energy dependence of the photon yields is consistent with the tabulated stopping power values. Finally, the experimental results are benchmarked against Geant4 simulations, demonstrating consistent agreement and validating the capability of the detector system for radiology measurements.

Digital camera↗

Gallium oxide (Ga 2 O 3 ) energy dependent scintillation response to fast neutrons and flash gamma-rays

Gallium oxide is a newly emerged ultrawide bandgap (4.9 eV) semiconductor that is suitable as a combined electronics and radiation detection platform. We have experimentally demonstrated fast neutron and gamma-ray scintillation from Czochralski-grown β-Ga 2 O 3 in a recent series (October 2023) of experiments at the unmoderated pulsed neutron spallation source located at the Los Alamos Neutron Science Center. Using the neutron time-of-flight (TOF) technique and a fast-gated intensified CCD camera, we observed energy-dependent neutron scintillation for neutron energies ranging from 1 to 400 MeV, including the 14.1 MeV neutron energy relevant to D–T fusion. Neutron flux is quantified and calibrated by cascading the scintillator after the fission chamber, enabling a detailed analysis of temporal and energy-dependent characteristics of the scintillation events. Further, a pronounced scintillation signal from the spallation gamma flash with a temporal full width of half maximum of ~4 ns is indicative of the material’s rapid response. Neutron energy dependent scintillation is observed using the TOF method at a 22.6-m distance from the neutron source. These results highlight the possibility of developing a Ga 2 O 3 based fusion neutron diagnostic platform integrated with both scintillation and electronics functions on the integrated chip scale.

47 OTHER INSTRUMENTATION↗