Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ELECTRON DETECTOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

NASA Applications of Molecular Adsorber Coatings

The Molecular Adsorber Coating (MAC) is a new, innovative technology that was developed to reduce the risk of molecular contamination on spaceflight applications. Outgassing from materials, such as plastics, adhesives, lubricants, silicones, epoxies, and potting compounds, pose a significant threat to the spacecraft and the lifetime of missions. As a coating made of highly porous inorganic materials, MAC offers impressive adsorptive capabilities that help capture and trap contaminants. Past research efforts have demonstrated the coating's promising adhesion performance, optical properties, acoustic durability, and thermal stability. These results advocate its use near or on surfaces that are targeted by outgassed materials, such as internal optics, electronics, detectors, baffles, sensitive instruments, thermal control coatings, and vacuum chamber test environments. The MAC technology has significantly progressed in development over the recent years. This presentation summarizes the many NASA spaceflight applications of MAC and how the coatings technology has been integrated as a mitigation tool for outgassed contaminants. For example, this sprayable paint technology has been beneficial for use in various vacuum chambers for contamination control and hardware bake-outs. The coating has also been used in small instrument cavities within spaceflight instrument for NASA missions.

molecular contaimination↗

Understanding Radiation Thermometry

This document is a two-part course on the theory and practice of radiation thermometry. Radiation thermometry is the technique for determining the temperature of a surface or a volume by measuring the electromagnetic radiation it emits. This course covers the theory and practice of radiative thermometry and emphasizes the modern application of the field using commercially available electronic detectors and optical components. The course covers the historical development of the field, the fundamental physics of radiative surfaces, along with modern measurement methods and equipment.

Risch Timothy K.↗

Understanding Radiation Thermometry

This document is a two-part course on the theory and practice of radiation thermometry. Radiation thermometry is the technique for determining the temperature of a surface or a volume by measuring the electromagnetic radiation it emits. This course covers the theory and practice of radiative thermometry and emphasizes the modern application of the field using commercially available electronic detectors and optical components. The course covers the historical development of the field, the fundamental physics of radiative surfaces, along with modern measurement methods and equipment.

Risch, Timothy K.↗

Evaluation of Encapsulated Inhibitor for Autonomous Corrosion Protection

This work concerns the development of smart coating technologies based on microencapsulation for the autonomous control of corrosion. Microencapsulation allows the incorporation of corrosion inhibitors into coating which provides protection through corrosion-controlled release of these inhibitors.One critical aspect of a corrosion protective smart coating is the selection of corrosion inhibitor for encapsulation and comparison of the inhibitor function before and after encapsulation. For this purpose, a systematic approach is being used to evaluate free and encapsulated corrosion inhibitors by salt immersion. Visual, optical microscope, and Scanning Electron Microscope (with low-angle backscatter electron detector) are used to evaluate these inhibitors. It has been found that the combination of different characterization tools provide an effective method for evaluation of early stage localized corrosion and the effectiveness of corrosion inhibitors.

Autonomous↗

CARBO - The Carbon Observatory Instrument Suite - The Next Generation of Earth Observing Instruments for Global Monitoring of Carbon Gases

The Carbon Observatory Instrument Suite, or CARBO, consists of four carbon observing instruments sharing a common instrument bus, yet targeted for a particular wavelength band each with a unique science observation. They are: a) Instrument 1, wavelength centered at 756 nm for oxygen and solar-induced chlorophyll fluorescence (SIF) observations, b) Instrument 2, centered at 1629 nm, for carbon dioxide (CO2) and methane (CH4) observation, c) Instrument 3, centered at 2062 nm for carbon dioxide and d) Instrument 4, centered at 2328 for carbon monoxide (CO) and methane. From low-Earth orbit, these instruments have a field-of-view of 10 to 15 degrees, and a spatial resolution of 2 km square. These instruments have a spectral resolving power ranging from ten to twenty thousand, and can monitor columnaverage dry air mole fraction of carbon dioxide (XCO2) at 1.5 ppm, and methane (XCH4) at 7 ppb. These new instruments will advance the use of immersion grating technology in spectrometer instruments in order to reduce the size of the instrument, while improving performance. These compact, capable instruments are envisioned to be compatible with small satellites, yet modular to be configured to address the particular science questions at hand. Here we report on the current status of the instrument design and fabrication, focusing primarily on Instruments 1 and 2. We will describe the key science and engineering requirements and the instrument performance error budget. We will discuss the optical design with particular emphasis on the immersion grating, and the advantages this new technology affords compared to previous instruments. We will also discuss the status of the focal plane array and the detector electronics and housing. Finally, we report on a new approach – developed during this instrument design process - which enables simultaneous measurement of both orthogonal polarization states (S and P) over the field-of-view and optical bandpass. We believe this polarization sensing capability will enable science observations which were previously limited by instrumental and observational degeneracies. In particular: improved sensitivity to all species, better sensitivity to surface polarization effects, better constraints on aerosol scattering parameters, and superior discrimination of the vertical distribution of gases and aerosols.

Bernas, Michael↗

US Contributions to the Athena Wide Field Imager

The world’s premier X-ray astronomical observatories, Chandra and XMM-Newton, have been operating for about 20 years. The next flagship X-ray observatory launched will be ESA’s Athena mission. We discuss planned US contributions to the Athena Wide Field Imager instrument, which encompass transient source detection, background characterization and reduction, and detector electronics design and testing, in addition to scientific contributions.

David N. Burrows↗

An Updated Geomagnetic Index-Based Model for Determining the Latitudinal Extent of Energetic Electron Precipitation

Energetic Electron Precipitation (EEP) from the Earth's plasma sheet and the radiation belts is an important feature of atmospheric dynamics through their destruction of ozone in the lower thermosphere and mesosphere. Therefore, understanding the magnitude of the atmospheric impact of the Sun-Earth interaction requires a comprehensive understanding of the intensity and location of EEP. This study improves the accuracy of a previous pressure-corrected Dst model that predicts the equatorward extent of >43, >114, and >292 keV EEP using the measurements from the Medium Energy Proton Electron Detector detector of six National Oceanic and Atmospheric Administration/Polar Orbiting Environmental Satellites and EUMETSAT/METOP satellites. The improvement is achieved through multiple linear regression of pressure-corrected Dst and pressure-corrected Ring Current (RC) indices. The RC index mitigates the baseline variation of the Dst index that created an inherent solar cycle bias in the previous model. The new model is then extended to the Southern Hemisphere (SH) after removing the South Atlantic Anomaly longitudes from the data. More than 80% of the residuals lie within ±1.8° Corrected Geomagnetic Latitude (CGMLat) in the Northern Hemisphere and within ±1.98° CGMLat in the SH.

E. M. Babu↗

Atmospheric measurements of carbonyl sulfide, dimethyl sulfide, and carbon disulfide using the electron capture sulfur detector

Measurements of atmospheric dimethyl sulfide (DMS), carbonyl sulfide (COS), and carbon disulfide (CS2) were conducted over the Atlantic Ocean on board the NASA Electra aircraft during the Chemical Instrumentation Test and Evaluation (CITE 3) project using the electron capture sulfur detector (ECD-S). The system employed cryogenic preconcentration of air samples, gas chromatographic separation, catalytic fluorination, and electron capture detection. Samples collected for DMS analysis were scrubbed of oxidants with NaOH impregnated glass fiber filters to preconcentration. The detection limits (DL) of the system for COS, DMS, and CS2 were 5, 5, and 2 ppt, respectively. COS concentrations ranged from 404 to 603 ppt with a mean of 489 ppt for measurements over the North Atlantic Ocean (31 deg N to 41 deg N), and from 395 to 437 ppt with a mean of 419 ppt for measurements over the Tropical Atlantic Ocean (11 deg S to 2 deg N). DMS concentrations in the lower marine boundary layer, below 600-m altitude, ranged from below DL to 150 ppt from flights over the North Atlantic, and from 9 to 104 ppt over the Tropical Atlantic. CS2 concentrations ranged from below DL to 29 ppt over the North Atlantic. Almost all CS2 measurements over the Tropical Atlantic were below DL.

Johnson, James E.↗

Superconducting Hot-Electron Submillimeter-Wave Detector

A superconducting hot-electron bolometer has been built and tested as a prototype of high-sensitivity, rapid-response detectors of submillimeter-wavelength radiation. There are diverse potential applications for such detectors, a few examples being submillimeter spectroscopy for scientific research; detection of leaking gases; detection of explosive, chemical, and biological weapons; and medical imaging. This detector is a superconducting-transition- edge device. Like other such devices, it includes a superconducting bridge that has a low heat capacity and is maintained at a critical temperature (T(sub c)) at the lower end of its superconducting-transition temperature range. Incident photons cause transient increases in electron temperature through the superconducting-transition range, thereby yielding measurable increases in electrical resistance. In this case, T(sub c) = 6 K, which is approximately the upper limit of the operating-temperature range of silicon-based bolometers heretofore used routinely in many laboratories. However, whereas the response speed of a typical silicon- based laboratory bolometer is characterized by a frequency of the order of a kilohertz, the response speed of the present device is much higher characterized by a frequency of the order of 100 MHz. For this or any bolometer, a useful figure of merit that one seeks to minimize is (NEP)(tau exp 1/2), where NEP denotes the noise-equivalent power (NEP) and the response time. This figure of merit depends primarily on the heat capacity and, for a given heat capacity, is approximately invariant. As a consequence of this approximate invariance, in designing a device having a given heat capacity to be more sensitive (to have lower NEP), one must accept longer response time (slower response) or, conversely, in designing it to respond faster, one must accept lower sensitivity. Hence, further, in order to increase both the speed of response and the sensitivity, one must make the device very small in order to make its heat capacity very small; this is the approach followed in developing the present device.

Karasik, Boris↗

Michel Electron Selection with SPINE for DUNE Far Detector Simulation

Michel electrons are a valuable input for particle detector calibration due to their consistent kinetic energy distribution. This report details the evaluation of a Michel electron identification method's application to simulated data from the DUNE (Deep Underground Neutrino Experiment) far detector. This method, which relies on the neural network-based particle classification software SPINE (Scalable Particle Imaging with Neural Embeddings), was developed and calibrated using simulated data for the SBND (Short-Baseline Neutrino Detector) experiment before being applied to simulated DUNE data from a 1x2x6 subset of far detector modules.

Wilson, Dante [Colorado State U.]↗

A novel electron tunneling infrared detector

The pneumatic infrared detector, originally developed by Golay in the late 1940s, uses the thermal expansion of one cm(exp 3) of xenon at room temperature to detect the heat deposited by infrared radiation. This detector was limited by thermal fluctuations within a 10 Hz bandwidth, but suffered from long thermal time constants and a fragile structure. Nevertheless, it represents the most sensitive room temperature detector currently available in the long wavelength infrared (LWIR). Fabrication of this type of detector on smaller scales has been limited by the lack of a suitably sensitive transducer. Researchers designed a detector based on this principle, but which is constructed entirely from micromachined silicon, and uses a vacuum tunneling transducer to detect the expansion of the trapped gas. Because this detector is fabricated using micromachining techniques, miniaturization and integration into one and two-dimensional arrays is feasible. The extreme sensitivity of vacuum tunneling to changes in electrode separation will allow a prototype of this detector to operate in the limit of thermal fluctuations over a 10 kHz bandwidth. A calculation of the predicted response and noise of the prototype is presented with the general formalism of thermal detectors. At present, most of the components of the prototype have been fabricated and tested independently. In particular, a characterization of the micromachined electron tunneling transducer has been carried out. The measured noise in the tunnel current is within a decade of the limit imposed by shot noise, and well below the requirements for the operation of an infrared detector with the predicted sensitivity. Assembly and characterization of the prototype infrared detector will be carried out promptly.

Kenny, T. W.↗

Single-element Electron-transfer Optical Detector System

An optical detector system includes an electrically resistive screen that is substantially transparent to radiation energy having a wavelength of interest. An electron transfer element (e.g., a low work function photoactive material or a carbon nanotube (CNT)-based element) has a first end and a second end with its first end spaced apart from the screen by an evacuated gap. When radiation energy passes through the screen with a bias voltage being applied thereto, transfer of electrons through the electron transfer element is induced from its first to its second end such that a quantity indicative of the electrons transferred can be detected.

Jeffrey D Jordan↗

Multi-Element Electron-Transfer Optical Detector System

A multi-element optical detector system includes an electrically resistive screen that is substantially transparent to radiation energy having a wavelength of interest. A plurality of electron transfer elements (e.g., a low work function photoactive material or a carbon nanotube (CNT)-based element) are provided with each having a first end and a second end. The first end of each element is spaced apart from the screen by an evacuated gap. When the radiation energy passes through the screen with a bias voltage applied thereto, transfer of electrons through each element is induced from the first end to the second end such that a quantity indicative of the electrons transferred through each element can be detected.

Jeffrey D Jordan↗

Micromachined Electron-Tunneling Infrared Detectors

Pneumatic/thermal infrared detectors based partly on Golay-cell concept, but smaller and less fragile. Include containers filled with air or other gas trapped behind diaphragms. Infrared radiation heats sensors, causing gas to expand. Resulting deflections of diaphragms measured by displacement sensors based on principle of electron-tunneling transducers of scanning tunneling microscopes. Exceed sensitivity of all other miniature, uncooled infrared sensors presently available. Expected to include low consumption of power, broadband sensitivity, room-temperature operation, and invulnerability to ionizing radiation.

Kenny, Thomas W.↗

A Neutron Detector for the Electron Calorimeter (ECAL) Long Duration Balloon Experiment

The highest energy measurements of cosmic ray electrons extend just beyond 1 TeV. High energy electrons are of particular interest because energy losses during interstellar propagation insure that they arrive primarily from nearby sources. This may produce observable structure in their spectrum. Further, it is predicted that electrons and positrons result from the annihilation of many exotic particles deposited as dark matter candidates. These electrons may appear as excesses in the cosmic ray electron spectrum from 200 GeV to 1000 GeV. A new long duration balloon experiment, ECAL, is being planned to provide direct cosmic ray electron measurements from approx.50 GeV to >1 TeV. To make these measurements ECAL must discriminate strongly against showers from protons and heavier ions. One of the techniques used to make this discrimination may be based on measuring the secondary neutrons produced by events in the instrument. The neutron detector configuration and technique will be discussed along with its expected performance based on Monte Carlo simulations.

Adams, J. H., Jr.↗