Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ECCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

A bioreactor system for the nitrogen loop in a Controlled Ecological Life Support System

As space missions become longer in duration, the need to recycle waste into useful compounds rises dramatically. This problem can be addressed by the development of Controlled Ecological Life Support Systems (CELSS) (i.e., Engineered Closed/Controlled Eco-Systems (ECCES)), consisting of human and plant modules. One of the waste streams leaving the human module is urine. In addition to the reclamation of water from urine, recovery of the nitrogen is important because it is an essential nutrient for the plant module. A 3-step biological process for the recycling of nitrogenous waste (urea) is proposed. A packed-bed bioreactor system for this purpose was modeled, and the issues of reaction step segregation, reactor type and volume, support particle size, and pressure drop were addressed. Based on minimization of volume, a bioreactor system consisting of a plug flow immobilized urease reactor, a completely mixed flow immobilized cell reactor to convert ammonia to nitrite, and a plug flow immobilized cell reactor to produce nitrate from nitrite is recommended. It is apparent that this 3-step bioprocess meets the requirements for space applications.

NASA Discipline Number 61-10↗

Accuracy and Precision in the Southern Hemisphere Additional Ozonesondes (SHADOZ) Dataset in Light of the JOSIE-2000 Results

Since 1998 the Southern Hemisphere ADditional OZonesondes (SHADOZ) project has provided over 2000 ozone profiles over eleven southern hemisphere tropical and subtropical stations. Balloon-borne electrochemical concentration cell (ECC) ozonesondes are used to measure ozone. The data are archived at: &ttp://croc.gsfc.nasa.gov/shadoz>. In analysis of ozonesonde imprecision within the SHADOZ dataset, Thompson et al. [JGR, 108,8238,20031 we pointed out that variations in ozonesonde technique (sensor solution strength, instrument manufacturer, data processing) could lead to station-to-station biases within the SHADOZ dataset. Imprecisions and accuracy in the SHADOZ dataset are examined in light of new data. First, SHADOZ total ozone column amounts are compared to version 8 TOMS (2004 release). As for TOMS version 7, satellite total ozone is usually higher than the integrated column amount from the sounding. Discrepancies between the sonde and satellite datasets decline two percentage points on average, compared to version 7 TOMS offsets. Second, the SHADOZ station data are compared to results of chamber simulations (JOSE-2000, Juelich Ozonesonde Intercomparison Experiment) in which the various SHADOZ techniques were evaluated. The range of JOSE column deviations from a standard instrument (-10%) in the chamber resembles that of the SHADOZ station data. It appears that some systematic variations in the SHADOZ ozone record are accounted for by differences in solution strength, data processing and instrument type (manufacturer).

Witte, Jacquelyn C.↗

The Validation of Version 8 Ozone Profiles: Is SBUV Ready for Prime Time?

Ozone profile data are now available from a series of BUV instruments - SBUV on Nimbus 7 and SBW/2 instruments on NOAA 9, NOAA 11, and NOAA 16. The data have been processed through the new version 8 algorithm, which is designed to be more accurate and, more importantly, to reduce the influence of the a priori on ozone trends. As a part of the version 8 reprocessing we have attempted to apply a consistent calibration to the individual instruments so that their data records can be used together in a time series analysis. Validation consists of examining not only the mean difference from external datasets (i.e trends) but also consistency in the interannual variability of the data. Here we validate the v8 BUV data through comparison with ECC sondes, lidar and microwave measurements, and with SAGE II and HALOE satellite data records. We find that individual profiles generally agree with external data sets within +/-10% between 30 hPa and 1 hPa (approx. 24 - 50 km) and frequently agree within +/-5%. The interannual variability of the BUV ozone time series agrees well with that of SAGE II . On the average, different B W instruments usually agree within +/-5% with each other, though the relative error increases near the ends of the Nimbus 7 and NOAA 16 data records as a result of instrument problems. The combined v8 BUV data sets cover the 1979-2003 time period giving daily global coverage of the ozone vertical distribution to better accuracy than has ever been possible before.

McPeters, R. D.↗

SHADOZ (Southern Hemisphere Additional Ozonesondes): A Project Overview and New Insights on Tropical Tropospheric Ozone

The SHADOZ (Southern Hemisphere Additional Ozonesondes) ozone sounding network was initiated in 1998 to improve the coverage of tropical in-situ ozone measurements for satellite validation, algorithm development and related process studies. Over 2000 soundings have been archived at the website, http://croc.gsfc.nasa.gov/shadoz, for 12 stations: Ascension Island; Nairobi and Malindi, Kenya; Irene, South Africa; Reunion Island; Watukosek, Java; Fiji; Tahiti; American Samoa; San Cristobal, Galapagos; Natal, Brazil; Paramaribo, Surinam. Key results from SHADOZ will be described from among the following: 1) By using ECC sondes with similar procedures, 5-10% accuracy and precision (1-sigma) of the sonde total ozone measurement is achieved; 2) Week-to-week variability in tropospheric ozone is so great that statistics are frequently not Gaussian; most stations vary up to a factor of 3 in tropospheric column over the course of a year; 3) Longitudinal variability in tropospheric ozone profiles is a consistent feature, with a 10-15 DU column-integrated difference between Atlantic and Pacific sites; this causes a "zonal wave-one" feature in total ozone; 4) The ozone record from Paramaribo, Surinam (6N, 55W) is a marked contrast to southern tropical ozone because Surinam is often north of the Intertropical Convergence Zone.

Thompson, Anne M.↗

Vertical Profiling of Air Pollution at RAPCD

The interaction between local and regional pollution levels occurs at the interface of the Planetary Boundary Layer and the Free Troposphere. Measuring the vertical distribution of ozone, aerosols, and winds with high temporal and vertical resolution is essential to diagnose the nature of this interchange and ultimately for accurately forecasting ozone and aerosol pollution levels. The Regional Atmospheric Profiling Center for Discovery, RAPCD, was built and instrumented to address this critical issue. The ozone W DIAL lidar, Nd:YAG aerosol lidar, and 2.1 micron Doppler wind lidar, along with balloon- borne ECC ozonesondes form the core of the W C D instrumentation for addressing this problem. Instrumentation in the associated Mobile Integrated Profiling (MIPS) laboratory includes 91 5Mhz profiler, sodar, and ceilometer. The collocated Applied particle Optics and Radiometry (ApOR) laboratory hosts an FTIR along with MOUDI and optical particle counters. With MODELS-3 analysis by colleagues in the National Space Science and Technology Center on the UAH campus and the co- located National Weather Service Forecasting Office in Huntsville, AL we are developing a unique facility for advancing the state of the science of pollution forecasting.

Newchurch, Michael J.↗

The Southern Hemisphere Additional Ozonesondes (SHADOZ) 1998-2002 Tropical Ozone Climatology: Instrumentation and Station-to-Station Variability - 3

Abstract: Since 1998 the Southern Hemisphere ADditional OZonesondes (SHADOZ) project has collected more than 2000 ozone profiles from a dozen tropical and subtropical sites using balloon-borne electrochemical concentration cell (ECC) ozonesondes. The data (with accompanying pressure-temperature-humidity soundings) are archived. Analysis of ozonesonde imprecision within the SHADOZ dataset revealed that variations in ozonesonde technique could lead to station-to-station biases in the measurements. In this paper imprecisions and accuracy in the SHADOZ dataset are examined in light of new data. When SHADOZ total ozone column amounts are compared to version 8 TOMS (2004 release), discrepancies between sonde and satellite datasets decline 1-2 percentage points on average, compared to version 7 TOMS. Variability among stations is evaluated using total ozone normalized to TOMS and results of laboratory tests on ozonesondes (JOSE-2O00, Julich Ozonesonde Intercomparison Experiment). Ozone deviations from a standard instrument in the JOSE flight simulation chamber resemble those of SHADOZ station data relative to a SHADOZ-defined climatological reference. Certain systematic variations in SHADOZ ozone profiles are accounted for by differences in solution composition, data processing and instrument (manufacturer). Instrument bias leads to a greater ozone measurement above 25 km over Nairobi and to lower total column ozone at three Pacific sites compared to other SHADOZ stations at 0-20 deg.S.

Thompson, Anne M.↗

New Insights on Tropical Ozone from SHADOZ (Southern Hemisphere Additional Ozonesondes) Profiles

The SHADOZ (Southern Hemisphere Additional Ozonesondes) ozone sounding network was initiated in 1998 to improve the coverage of tropical in-situ ozone measurements for satellite validation, algorithm development and related process studies. Over 2000 soundings have been archived at the website, , for 12 stations: Ascension Island; Nairobi and Malindi, Kenya; Irene, South Africa; Reunion Island, Watukosek, Java; Fiji; Tahiti; American Samoa; San Cristobal, Galapagos; Natal, Brazil; Paramaribo, Surinam. Key results from SHADOZ will be described from among the following: 1) By using ECC sondes with similar procedures, 5-10% accuracy and precision (1-sigma) of the sonde total ozone measurement was achieved; 2) Week-to-week variability in tropospheric ozone is so great that statistics are frequently not Gaussian; most stations vary up to a factor of 3 in tropospheric column over the course of a year; 3) Longitudinal variability in tropospheric ozone profiles is a consistent feature, with a 10-15 DU column-integrated difference between Atlantic and Pacific sites; this causes a "zonal wave-one" feature in total ozone. 4) The ozone record from Paramaribo, Surinam (6N, 55W) is a marked contrast to southern tropical ozone because Surinam is often north of the Intertropical Convergence Zone; 5) Indian Ocean region pollution may contribute up to half of the excess ozone observed in the south tropical Atlantic paradox in the December-January-February period of the year.

Thompson, Anne M.↗

On the Quality of the Nimbus 7 LIMS Version 6 Ozone for Studies of the Middle Atmosphere

The Nimbus 7 Limb Infrared Monitor of the Stratosphere (LIMS) radiance profile dataset of 1978/79 was reconditioned and reprocessed to Version 6 (V6) profiles of temperature and species that are improved significantly over those from Version 5 (V5). The LIMS V6 dataset was archived for public use in 2002. Improvements for its ozone include: (1) a more accurate accounting for instrument and spacecraft motion effects in the radiances, (2) the use of better spectroscopic line parameters for its ozone forward model, (3) retrievals of all its scans, (4) more accurate and compatible temperature versus pressure profiles (or T(p)), which are needed for the registration of the ozone radiances and for the removal of temperature effects from them, and (5) a better accounting for interfering species in the lower stratosphere. The retrieved V6 ozone profiles extend from near cloud top altitudes to about 80 km and from 64S to 84N latitude with better sampling along the orbit than for the V5 dataset. Calculated estimates of the single-profile precision and accuracy are provided for the V6 ozone from this study. Precision estimates based on the data themselves are of order 3% or better from 1 to 30 hPa. Estimates of total systematic error for a single profile are hard to generalize because the separate sources of error may not all be of the same sign and they depend somewhat on the atmospheric state. It is estimated that the V6 zonal mean ozone distributions are accurate to within 9% to 7% from 50 hPa to 3 hPa, respectively. Effects of a temperature bias can be significant and may be present at 1 to 2 hPa though. There may be ozone biases of order 10% at those levels due to possible biases of up to +2 K, but there is no indication of a similar problem elsewhere in the stratosphere. Simulation studies show that the LIMS retrievals are also underestimating slightly the small amplitudes of the atmospheric temperature tides, which affect its retrieved day/night ozone differences. There are small biases in the middle to lower stratosphere for the ascending versus descending node LIMS ozone, due principally to not accounting for the asymmetric weighting of its radiances across the tangent layer. The estimates of total accuracy were assessed by comparing the daily zonal mean LIMS ozone distributions against those from the Nimbus 7 SBUV Version 8 (V8) dataset for the same period. Generally, the LIMS V6 ozone agrees well with SBUV, except perhaps in the tropical lower stratosphere where the LIMS ozone is less. Still, the accuracy for LIMS V6 ozone in the lower stratosphere is improved over that found for LIMS V5, as indicated by several LIMS comparisons with ECC ozonesonde profiles. The LIMS V6 ozone is considered especially suitable for detailed studies of large-scale stratospheric processes above the 100-hPa level. Comparison of diurnal, photochemical model calculations with the monthly-averaged, upper stratospheric ozone observed from LIMS V6 indicates only a slight ozone deficit for the model at about 2 hPa. However, that deficit exhibits little to no seasonal variation and is in good agreement with similar model comparisons for a seasonal time series of ozone obtained with ground-based microwave instruments. Because the LIMS V6 ozone in the lower stratosphere has improved accuracy and sampling versus that of V5, it should now be possible to conduct quantitative studies of ozone transport and chemistry for the northern hemisphere, polar stratospheric winter of 1978/79 a time period when the catalytic loss of ozone due to reactive chlorine should not have been a major factor for the Arctic region.

Remsberg, Ellis↗

Fault Mitigation Schemes for Future Spaceflight Multicore Processors

Future planetary exploration missions demand significant advances in on-board computing capabilities over current avionics architectures based on a single-core processing element. The state-of-the-art multi-core processor provides much promise in meeting such challenges while introducing new fault tolerance problems when applied to space missions. Software-based schemes are being presented in this paper that can achieve system-level fault mitigation beyond that provided by radiation-hard-by-design (RHBD). For mission and time critical applications such as the Terrain Relative Navigation (TRN) for planetary or small body navigation, and landing, a range of fault tolerance methods can be adapted by the application. The software methods being investigated include Error Correction Code (ECC) for data packet routing between cores, virtual network routing, Triple Modular Redundancy (TMR), and Algorithm-Based Fault Tolerance (ABFT). A robust fault tolerance framework that provides fail-operational behavior under hard real-time constraints and graceful degradation will be demonstrated using TRN executing on a commercial Tilera(R) processor with simulated fault injections.

software based↗

Homogenizing and Estimating the Uncertainty in NOAA's Long-Term Vertical Ozone Profile Records Measured with the Electrochemical Concentration Cell Ozonesonde

NOAA's program of long-term monitoring of the vertical distribution of ozone with electrochemical concentration cell (ECC) ozonesondes has undergone a number of changes over the 50-year record. In order to produce a homogenous data set, these changes must be documented and, where necessary, appropriate corrections applied. This is the first comprehensive and consistent reprocessing of NOAA's ozonesonde data records that corrects for these changes using the rawest form of the data (cell current and pump temperature) in native resolution as well as a point-by-point uncertainty calculation that is unique to each sounding. The reprocessing is carried out uniformly at all eight ozonesonde sites in NOAA's network with differences in sensing solution and ozonesonde types accounted for in the same way at all sites. The corrections used to homogenize the NOAA ozonesonde data records greatly improve the ozonesonde measurements with an average one sigma uncertainty of +/- 4-6% in the stratosphere and +/- 5-20% in the troposphere. A comparison of the integrated column ozone from the ozonesonde profile with co-located Dobson spectrophotometers total column ozone measurements shows agreement within +/- 5% for >70% of the profiles. Very good agreement is also found in the stratosphere between ozonesonde profiles and profiles retrieved from the Solar Backscatter Ultraviolet (SBUV) instruments.

ozonesonde↗

Context Cameras for the Orbiting Carbon Observatory 3 (OCO-3) Instrument

We have developed an adaptable camera platform that takes advantage of screened and qualified commercial off the shelf (COTS) components (CMOS sensor, rad-tolerant microcircuits, lenses) to significantly shorten development time of space-borne visible imaging systems while reducing the overall cost and risk of the development. This modular camera platform is implemented as a suite of two visible-light cameras for the Orbiting Carbon Observatory 3 (OCO-3) instrument at NASA’s Jet Propulsion Laboratory (JPL). The Internal Context Camera (ICC) and External Context Camera (ECC) provide contextual engineering imaging support for the calibration of the OCO-3 instrument, intended to significantly reduce the duration of the mission’s calibration campaign. The OCO-3 mission has taken advantage of the design and qualification work performed by JPL’s Mars 2020 Enhanced Engineering Camera (EECam) team in reusing the qualified COTS CMOS imaging sensor, proven electronic designs, and scalable field-programmable gate array (FPGA) firmware to meet OCO-3’s mission requirements and resource availability. We will be presenting the steps taken by JPL to design, build, and test the Context Cameras for the OCO-3 mission. We will highlight the design deviations from the Mars2020 EECams and discuss the methodology of tailoring the EECam design for the OCO-3 requirements. Camera imaging capabilities, including focal plane and optical performance, will be presented, as well as a summary of the calibration and environmental test results. Finally, we will discuss the potential for future applications for the Context Cameras.

Moore, Douglas↗

Evaluating Long-Term Changes in Atmospheric Ozone

Ozonesondes have made inexpensive, accurate measurements of ozone from the ground to 30km for more than 50 years. The data are used extensively for trend analyses and for evaluation of satellite and model data products, and are also part of climatologies that are used as a priori data for satellite retrievals. They are essential as a transfer standard when merging shorter satellite-derived time series, and are the most important source of trend-quality long-term records below about 18 km. The importance of long-term ozonesonde records as a stable reference has led to increased attention to quantifying uncertainties and changes in ozonesonde data. Based on past intercomparison data, ECC sondes show a modest (~1-5%) high bias with respect to UV-absorption measurements (including MOZAIC-IAGOS) in the troposphere, with an uncertainty of 5%, but no evidence of a change with time. Other sonde types show an increase of 5-20% in sensitivity to tropospheric ozone from 1970-1995. Agreement in the stratosphere is much better. In the past 20 years ozonesonde precision has improved by a factor of 2, primarily through the adoption of strict standard operating procedures. In addition, many of the most important ozonesonde records have been re-evaluated and corrected, and detailed estimates made of their biases and uncertainties. Corrections to historical data for known issues may reduce biases but simultaneously introduce additional uncertainties. The uncertainty budget for the ozone partial pressure reading has contributions from stoichiometry, cell background current, pump efficiency and temperature, sensing solution type and volume. The much-discussed “background current” has recently been shown to be primarily related to reaction stoichiometry. Several quality assurance issues remain, but are tractable problems that can be addressed with further research. This will be required if the present goal of better than 5% overall uncertainty throughout the global ozonesonde network is to be achieved. Finally, the importance of regular sonde intercomparisons, employing UV photometers traceable to the modern UV-absorption standard, and of regular comparison of operational station records with multiple satellite sensors, is emphasized.

Ozonesondes↗

Caching data from remote memories

An approach is disclosed that caches distant memories within the storage a local node. The approach provides a memory caching infrastructure that supports virtual addressing by utilizing memory in the local node as a cache of distant memories for data granules. The data granules are accessed along with metadata and an ECC associated with the data granule. The metadata is updated to indicate storage of the selected data granule in the cache.

Johns, Charles Ray↗

System and methods for hardware-software cooperative pipeline error detection

An error reporting system utilizes a parity checker to receive data results from execution of an original instruction and a parity bit for the data. A decoder receives an error correcting code (ECC) for data resulting from execution of a shadow instruction of the original instruction, and data error correction is initiated on the original instruction result on condition of a mismatch between the parity bit and the original instruction result, and the decoder asserting a correctable error in the original instruction result.

97 MATHEMATICS AND COMPUTING↗

Continuation Presentation PowerPoint

Emerald Cities Collaborative (ECC) is piloting a replicable model to increase the supply and diversity of technicians entering the solar/electrical workforces to meet demand for renewable energy, electrification, and energy efficiency.

14 SOLAR ENERGY↗

TINES - Time Integration, Newton and Eigen Solver v. 1.0

SAND2021-1505 O. TINES is an open source software providing math infrastructure for solving many stiff time ordinary differential equations (ODEs) and/or differential algebraic equations (DAEs) using a batch hierarchical parallelism. The code is written using a parallel programming model (i.e., Kokkos) to future-proof the next generation parallel computing platforms such as GPU accelerators. This code is developed to support Exascale Catalytic Chemistry (ECC) Project. The code provides fundamental math helpers that can aid other research projects. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Kim, Kyungjoo↗

Safety-Related Instrumentation and Control Pilot Upgrade: Conceptual - Detailed Design Phase Report and Lessons Learned

Historically, regulatory barriers have precluded nuclear plant safety-related (SR) Instrumentation and Control (I&C) system modernizations. These barriers have been largely addressed by industry and United States Nuclear Regulatory Commission (NRC) efforts, including development of the License Amendment Request (LAR) Alternate Review (AR) process for digital I&C upgrades. The U.S. Department of Energy (DOE) and the Idaho National Laboratory (INL) are supporting a SR I&C pilot upgrade at the Limerick Generating Station (LGS) to demonstrate this process and capturing associated lessons learned for the benefit of industry. In 2021, a paper summarizing lessons learned as captured in INL/EXT-20-59809, Safety Related Instrumentation & Control Pilot Upgrade Initial Scoping Phase Implementation Report and Lessons Learned was presented at the 12th NPIC & HMIT conference. It is recommended that readers of this paper review reference 1 or the associated Nuclear Journal paper for context. This paper summarizes activities performed and lessons learned for the conceptual design phase and portions of the detailed design phase as captured in INL/RPT-23-XXXX, “Safety-Related Instrumentation and Control Pilot Upgrade: Conceptual - Detailed Design Phase Report and Lessons Learned.” The portions of the effort covered by reference 2 include conceptual design phase activities from December 2020, through completion in November 2021, and detailed design activities through September 2022. These efforts and associated detailed documentation in reference 3 are intended to support similar industry upgrades as a foundation stone for a Digital Transformation that will improve plant safety, reliability, and operational performance while lowering plant total cost of ownership.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

An Interleaver Implementation for the Serially Concatenated Pulse-Position Modulation Decoder

We describe novel interleaver and deinterleaver architectures that support bandwidth efficient memory access for decoders of turbo-like codes that are used in conjunction with high order modulations. The presentation focuses on a decoder for serially concatenated pulse-position modulation (SCPPM), which is a forward-error-correction code designed by NASA to support laser communications from Mars at more than 50 megabits-per-second (Mbps). For 64-ary PPM, the new architectures effectively triple the fan-in of the interleaver and fan-out of the deinterleaver, enabling parallelization that doubles the overall throughput. The techniques described here can be readily modified for other PPM orders.

turbo decoding↗