Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Distribution System Planning”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Overgeneration from Solar Energy in California - A Field Guide to the Duck Chart

In 2013, the California Independent System Operator published the "duck chart,"" which shows a significant drop in mid-day net load on a spring day as solar photovoltaics (PV) are added to the system. The chart raises concerns that the conventional power system will be unable to accommodate the ramp rate and range needed to fully utilize solar energy, particularly on days characterized by the duck shape. This could result in "overgeneration"" and curtailed renewable energy, increasing its costs and reducing its environmental benefits. This paper explores the duck chart in detail, examining how much PV might need to be curtailed if additional grid flexibility measures are not taken, and how curtailment rates can be decreased by changing grid operational practices. It finds that under business-as-usual types of assumptions and corresponding levels of grid flexibility in California, solar penetrations as low as 20 percent of annual energy could lead to marginal curtailment rates that exceed 30 percent. However, by allowing (or requiring) distributed PV and storage (including new installations that are part of the California storage mandate) to provide grid services, system flexibility could be greatly enhanced. Doing so could significantly reduce curtailment and allow much greater penetration of variable generation resources in achieving a 50 percent renewable portfolio standard. Overall, the work described in this paper points to the need to fully integrate distributed resources into grid system planning and operations to allow maximum use of the solar resource.

14 SOLAR ENERGY↗

Energy Scheduling-based Operating Envelopes including a Distribution System Branch Screening Algorithm

This paper presents an energy scheduling-based formulation for computing operating envelopes including a distribution branch screening algorithm, termed DBS-ES. The contribution of the paper is two-fold: firstly, it presents an innovative methodology for calculating operating envelopes using energy scheduling (baseline), and secondly, it enhances this methodology by incorporating a custom distribution branch screening algorithm (DBS-ES). The custom algorithm leverages power system knowledge to reduce both model build time and total processing time while maintaining the same scheduling results as the baseline. The effectiveness of the proposed approach is demonstrated through experiments on the IEEE13, IEEE123, and EPRI Secondary test feeders. Results highlight a 24.5% decrease in model build time and an 8.17% decrease in total processing time when using DBS-ES compared to the baseline, specifically for the IEEE123 test feeder. Additionally, the paper briefly discusses the influence of utility-controlled storage on computing operating envelopes, noting a general incre

24 POWER TRANSMISSION AND DISTRIBUTION↗

Guest Editorial: Special Issue on recent advancements in electric power system planning with high-penetration of renewable energy resources and dynamic loads

The goal of this Special Issue is to present the state-of-the-art methodologies developed for expansion planning of all segments of the modern power systems, characterized by separated businesses, high penetration of renewable resources and new load types, as well as by application of technologically advanced solutions.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Integrated Simulation Development and Decision Support Tool-Set for Utility Market and Distributed Solar Power Generation

This project will enable utilities to develop long-term strategic plans that integrate high levels of renewable energy generation, and to better plan power system operations under high renewable penetration. The program developed forecast data streams for decision support and effective integration of centralized and distributed solar power generation in utility operations. This toolset focused on real time simulation of distributed power generation within utility grids with the emphasis on potential applications in day ahead (market) and real time (reliability) utility operations. The project team developed and demonstrated methodologies for quantifying the impact of distributed solar generation on core utility operations, identified protocols for internal data communication requirements, and worked with utility personnel to adapt the new distributed generation (DG) forecasts seamlessly within existing Load and Generation procedures through a sophisticated DMS. This project supported the objectives of the SunShot Initiative and SUNRISE by enabling core utility operations to enhance their simulation capability to analyze and prepare for the impacts of high penetrations of solar on the power grid. The impact of high penetration solar PV on utility operations is not only limited to control centers, but across many core operations. Benefits of an enhanced DMS using state-of-the-art solar forecast data were demonstrated within this project and have had an immediate direct operational cost savings for Energy Marketing for Day Ahead generation commitments, Real Time Operations, Load Forecasting (at an aggregate system level for Day Ahead), Demand Response, Long term Planning (asset management), Distribution Operations, and core ancillary services as required for balancing and reliability. This provided power system operators with the necessary tools and processes to operate the grid in a reliable manner under high renewable penetration.

14 SOLAR ENERGY↗

Final Technical Report for Contract No. DE-EE0006332, "Integrated Simulation Development and Decision Support Tool-Set for Utility Market and Distributed Solar Power Generation"

This project will enable utilities to develop long-term strategic plans that integrate high levels of renewable energy generation, and to better plan power system operations under high renewable penetration. The program developed forecast data streams for decision support and effective integration of centralized and distributed solar power generation in utility operations. This toolset focused on real time simulation of distributed power generation within utility grids with the emphasis on potential applications in day ahead (market) and real time (reliability) utility operations. The project team developed and demonstrated methodologies for quantifying the impact of distributed solar generation on core utility operations, identified protocols for internal data communication requirements, and worked with utility personnel to adapt the new distributed generation (DG) forecasts seamlessly within existing Load and Generation procedures through a sophisticated DMS. This project supported the objectives of the SunShot Initiative and SUNRISE by enabling core utility operations to enhance their simulation capability to analyze and prepare for the impacts of high penetrations of solar on the power grid. The impact of high penetration solar PV on utility operations is not only limited to control centers, but across many core operations. Benefits of an enhanced DMS using state-of-the-art solar forecast data were demonstrated within this project and have had an immediate direct operational cost savings for Energy Marketing for Day Ahead generation commitments, Real Time Operations, Load Forecasting (at an aggregate system level for Day Ahead), Demand Response, Long term Planning (asset management), Distribution Operations, and core ancillary services as required for balancing and reliability. This provided power system operators with the necessary tools and processes to operate the grid in a reliable manner under high renewable penetration.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Hosting Capacity Analysis for Developers

NREL's dynamic hosting capacity analysis can help you better understand the thresholds at which new distributed photovoltaic (DPV) systems will trigger upgrades to the electrical distribution system. This fact sheet is for PV developers.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

SU-F-T-156: Monte Carlo Simulation Using TOPAS for Synchrotron Based Proton Discrete Spot Scanning System

Purpose: This study provides an overview of the design and commissioning of the Monte Carlo (MC) model of the spot-scanning proton therapy nozzle and its implementation for the patient plan simulation. Methods: The Hitachi PROBEAT V scanning nozzle was simulated based on vendor specifications using the TOPAS extension of Geant4 code. FLUKA MC simulation was also utilized to provide supporting data for the main simulation. Validation of the MC model was performed using vendor provided data and measurements collected during acceptance/commissioning of the proton therapy machine. Actual patient plans using CT based treatment geometry were simulated and compared to the dose distributions produced by the treatment planning system (Varian Eclipse 13.6), and patient quality assurance measurements. In-house MATLAB scripts are used for converting DICOM data into TOPAS input files. Results: Comparison analysis of integrated depth doses (IDDs), therapeutic ranges (R90), and spot shape/sizes at different distances from the isocenter, indicate good agreement between MC and measurements. R90 agreement is within 0.15 mm across all energy tunes. IDDs and spot shapes/sizes differences are within statistical error of simulation (less than 1.5%). The MC simulated data, validated with physical measurements, were used for the commissioning of the treatment planning system. Patient geometry simulations were conducted based on the Eclipse produced DICOM plans. Conclusion: The treatment nozzle and standard option beam model were implemented in the TOPAS framework to simulate a highly conformal discrete spot-scanning proton beam system.

60 APPLIED LIFE SCIENCES↗

Comparison of 3D dose distributions for HDR {sup 192}Ir brachytherapy sources with normoxic polymer gel dosimetry and treatment planning system

Radiation fluence changes caused by the dosimeter itself and poor spatial resolution may lead to lack of 3-dimensional (3D) information depending on the features of the dosimeter and quality assurance of dose distributions for high–dose rate (HDR) iridium-192 ({sup 192}Ir) brachytherapy sources is challenging and experimental dosimetry methods used for brachytherapy sources are limited. In this study, we investigated 3D dose distributions of {sup 192}Ir brachytherapy sources for irradiation with single and multiple dwell positions using a normoxic gel dosimeter and compared them with treatment planning system (TPS) calculations. For dose calibration purposes, 100-mL gel-containing vials were irradiated at predefined doses and then scanned in an magnetic resonance (MR) imaging unit. Gel phantoms prepared in 2 spherical glasses were irradiated with {sup 192}Ir for the calculated dwell positions, and MR scans of the phantoms were obtained. The images were analyzed with MATLAB software. Dose distributions and profiles derived with 1-mm resolution were compared with TPS calculations. Linearity was observed between the delivered dose and the reciprocal of the T2 relaxation time constant of the gel. The x-, y-, and z-axes were defined as the sagittal, coronal, and axial planes, respectively, the sagittal and axial planes were defined parallel to the long axis of the source while the coronal plane was defined horizontally to the long axis of the source. The differences between measured and calculated profile widths of 3-cm source length and point source for 70%, 50%, and 30% isodose lines were evaluated at 3 dose levels using 18 profiles of comparison. The calculations for 3-cm source length revealed a difference of > 3 mm in 1 coordinate at 50% profile width on the sagittal plane and 3 coordinates at 70% profile width and 2 coordinates at 50% and 30% profile widths on the axial plane. Calculations on the coronal plane for 3-cm source length showed > 3-mm difference in 1 coordinate at 50% and 70% and 2 coordinates at 30% profile widths. The point source measurements and calculations for 50% profile widths revealed a difference > 3 mm in 1 coordinate on the sagittal plane and 2 coordinates on the axial plane. The doses of 3 coordinates on the sagittal plane and 4 coordinates on the axial plane could not be evaluated in 30% profile width because of low doses. There was good agreement between the gel dosimetry and TPS results. Gel dosimetry provides dose distributions in all 3 planes at the same time, which enables us to define the dose distributions in any plane with high resolution. It can be used to obtain 3D dose distributions for HDR {sup 192}Ir brachytherapy sources and 3D dose verification of TPS.

61 RADIATION PROTECTION AND DOSIMETRY↗

Equity‐aware power distribution system restoration

Abstract The efficient, reliable, and resilient supply of electricity has become essential for social and economic well‐being of the modern society. However, more frequent occurrence of extreme weather events has exposed inequity in the planning and operation practices of power distribution systems, evidenced in higher vulnerability and longer power interruptions for some parts of the grid as compared to others. This paper proposes an equity‐aware power distribution system restoration model in an effort to ensure a more equitable yet resilient power distribution operation after outages. To this end, the proposed equity‐aware distribution system restoration model balances the efficiency of the restoration operation and the equitable allocation of distributed energy resources among affected customers after an outage, while prioritizing the critical infrastructure (e.g. hospitals). The results demonstrate the effectiveness of the proposed framework to ensure a more equitable restoration process as measured by the proposed fairness and restoration performance indices.

Engineering↗

McGrath Community Energy Planning

The City of McGrath, a remote Alaskan community reliant on diesel fuel, developed a Community Energy Plan through the Energy Technologies Innovation Partnership Project (ETIPP) to address high energy costs, infrastructure vulnerabilities, and long-term sustainability. Guided by community-led priorities and technical assistance from partners including NREL, REAP, and ANTHC, the plan identifies eight focus areas: distribution system upgrades, solar and battery integration, river energy potential, emergency backup power, housing efficiency, water system losses, independent power producer models, and targeted funding strategies. The plan combines local knowledge with technical analysis to chart a path toward a more resilient, affordable, and sustainable energy future for McGrath.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Final Scientific Technical Report for "Microgrid RD&D and Testing of PIDC and PWD Systems"

Alstom Grid Inc’s (ALSTOM Grid) Research Design and Development (RD&D) project, “Microgrid RD&D and Testing for PIDC and PWD” was conducted in partnership with Philadelphia Industrial Development Corporation (PIDC) in its role as owner’s representative and manager of a vibrant commercial and industrial community, involving critical loads in one of the nation’s largest unregulated, non-military electric distribution systems. PIDC needed to develop solutions to address the planned considerable growth in Distributed Energy Resources (DER) Combined Heat Plan (CHP), Renewables, Distributed Generation (DG), Demand Response (DR) and Storage. In supporting the corporate objective, PIDC needed a new class of control systems for achieving enhanced energy resilience of their critical infrastructure operation during adverse conditions together with carbon emission reduction and optimization of the overall system operation economics through system energy efficiency during normal and emergency operating conditions. Additionally, PIDC anticipated the need to support a new class of commercial agreements with tenants, such as those for Urban Outfitters, for guaranteed one hundred percent (100%) grid resilience and electric power supply in case of utility outage conditions. The project was designed to address the challenges for the commercial & industrial (C&I) communities. But more importantly, the project included development of scalable and replicable solutions intended to target a multitude of the nation’s electric distribution communities. The project researched and developed a fully comprehensive prototype consisting of microgrid operation and control functions including islanding, synchronization and reconnection, protection, voltage, frequency, and power quality management, dispatch, and system resiliency. The project provided the foundation required to significantly enhance the overall national objectives set by the DOE for energy resilience, emission reduction and system energy efficiency improvement, including protection of critical infrastructure and public resources.

14 SOLAR ENERGY↗

SU-F-BRF-13: Investigating the Feasibility of Accurate Dose Measurement in a Deforming Radiochromic Dosimeter

Purpose: Presage-Def, a deformable radiochromic 3D dosimeter, has been previously shown to have potential for validating deformable image registration algorithms. This work extends this effort to investigate the feasibility of using Presage-Def to validate dose-accumulation algorithms in deforming structures. Methods: Two cylindrical Presage-Def dosimeters (8cm diameter, 4.5cm length) were irradiated in a water-bath with a simple 4-field box treatment. Isocentric dose was 20Gy. One dosimeter served as control (no deformation) while the other was laterally compressed during irradiation by 21%. Both dosimeters were imaged before and after irradiation with a fast (∼10 minutes for 1mm isotropic resolution), broad beam, high resolution optical-CT scanner. Measured dose distributions were compared to corresponding distributions calculated by a commissioned Eclipse planning system. Accuracy in the control was evaluated with 3D gamma (3%/3mm). The dose distribution calculated for the compressed dosimeter in the irradiation geometry cannot be directly compared via profiles or 3D gamma to the measured distribution, which deforms with release from compression. Thus, accuracy under deformation was determined by comparing integral dose within the high dose region of the deformed dosimeter distribution versus calculated dose. Dose profiles were used to study temporal stability of measured dose distributions. Results: Good dose agreement was demonstrated in the control with a 3D gamma passing rate of 96.6%. For the dosimeter irradiated under compression, the measured integral dose in the high dose region (518.0Gy*cm3) was within 6% of the Eclipse-calculated integral dose (549.4Gy*cm3). Elevated signal was noted on the dosimeter edge in the direction of compression. Change in dosimeter signal over 1.5 hours was ≤2.7%, and the relative dose distribution remained stable over this period of time. Conclusion: Presage-Def is promising as a 3D dosimeter capable of accurately measuring dose in a deforming structure, and warrants further study to quantify comprehensive accuracy at different levels of deformation. This work was supported by NIH R01CA100835. John Adamovics is the president of Heuris Inc., which commercializes PRESAGE.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A simple approach to using an amorphous silicon EPID to verify IMRT planar dose maps

A simplified method of verifying intensity modulated radiation therapy (IMRT) fields using a Varian aS500 amorphous silicon electronic portal imaging device (EPID) is demonstrated. Unlike previous approaches, it does not involve time consuming or complicated analytical processing of the data. The central axis pixel response of the EPID, as well as the profile characteristics obtained from images acquired with a 6 MV photon beam, was examined as a function of field size. Ion chamber measurements at various depths in a water phantom were then collected and it was found that at a specific depth d{sub ref}, the dose response and profile characteristics closely matched the results of the EPID analysis. The only manipulation required to be performed on the EPID images was the multiplication of a matrix of off axis ratio values to remove the effect of the flood field calibration. Similarly, d{sub ref} was found for 18 MV. Planar dose maps at d{sub ref} in a water phantom for a bar pattern, a strip pattern, and 14 clinical IMRT fields from two patient cases each being from a separate anatomical region, i.e., head and neck as well as the pelvis, for both energies were generated by the Pinnacle planning system (V7.4). EPID images of these fields were acquired and converted to planar dose maps and compared directly with the Pinnacle planar dose maps. Radiographic film dosimetry and a MapCHECK dosimetry device (Sun Nuclear Corporation, Melbourne, FL) were used as an independent verification of the dose distribution. Gamma analysis of the EPID, film, and Pinnacle planar dose maps generated for the clinical IMRT fields showed that approximately 97% of all points passed using a 3% dose/3mm DTA tolerance test. Based on the range of fields studied, the author's results appear to justify using this approach as a method to verify dose distributions calculated on a treatment planning system, including complex intensity modulated fields.

61 RADIATION PROTECTION AND DOSIMETRY↗

Case Study: Resilience Benefits of Distributed Wind Against Fuel and Weather Hazards in Alaska

In this case study of St. Mary’s Village, Alaska, we present a resilience evaluation exercise. A resilience framework is employed to identify system characteristics, relevant metrics, and resilience hazards and to assess the performance against the hazards with and without a distributed wind system installed. The results show the resilience benefits provided by the distributed wind installation against fuel shortage hazards and cold weather hazards. The resilience benefits can be assigned monetary values, which will be highly dependent on actual circumstances of the hazard, but provide insight into value streams of distributed wind that are not usually considered. For example, the single 900 kW turbine was found to prevent an average of 14,643 kWh of load from being dropped during a two-day diesel fuel shortage event, which saved the community $447,592 from the prevented outages. This case study serves as an example for novel power system resilience analysis and builds understanding of resilience hazards that are common across many power systems.

Culler, Megan J.↗

An Interpretable Planning Bot for Pancreas Stereotactic Body Radiation Therapy

Pancreas stereotactic body radiation therapy (SBRT) treatment planning requires planners to make sequential, time-consuming interactions with the treatment planning system to reach the optimal dose distribution. We sought to develop a reinforcement learning (RL)–based planning bot to systematically address complex tradeoffs and achieve high plan quality consistently and efficiently.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Distribution Operations: The Evolution of Distributed Energy Resources [Guest Editorial]

Utilities around the world are experiencing change with the increasing digitalization of their systems and those of their customers. Efforts to decarbonize the electric power system have led to growth in renewable energy resources, particularly distributed energy resources (DERs), such as generation, storage, and flexible load, both in front of and behind the meter. As this change occurs in any given utility service area, new tools, such as advanced distribution management systems (ADMSs), are needed to manage utility operations, planning, and business issues, some of which are discussed here.

distributed energy resources, DER, decarbonize, re↗

TH-CD-201-05: Characterization of a Novel Light-Collimating Tank Optical-CT System for 3D Dosimetry

Purpose: Comprehensive 3D dosimetry is highly desirable for advanced clinical QA, but costly optical readout techniques have hindered widespread implementation. Here, we present the first results from a cost-effective Integrated-lens Dry-tank Optical Scanner (IDOS), designed for convenient 3D dosimetry readout of radiochromic plastic dosimeters (e.g. PRESAGE). Methods: The scanner incorporates a novel transparent light-collimating tank, which collimates a point light source into parallel-ray CT geometry. The tank was designed using an in-house Monte-Carlo optical ray-tracing simulation, and was cast in polyurethane using a 3D printed mould. IDOS spatial accuracy was evaluated by imaging a set of custom optical phantoms, with comparison to x-ray CT images. IDOS dose measurement performance was assessed by imaging PRESAGE dosimeters irradiated with simple known dose distributions (e.g., 4 field box 6MV treatment with Varian Linac). Direct comparisons were made to images from our gold standard DLOS scanner and calculated dose distributions from a commissioned Eclipse planning system. Results: All optical CT images were reconstructed at 1mm isotropic resolution. Comparison of IDOS and x-ray CT images of the geometric phantom demonstrated excellent IDOS geometric accuracy (sub-mm) throughout the dosimeter. IDOS measured 3D dose distribution agreed well with prediction from Eclipse, with 95% gamma pass rate at 3%/3mm. Cross-scanner dose measurement gamma analysis shows >90% of pixels passing at 3%/3mm. Conclusion: The first prototype of the IDOS system has demonstrated promising performance, with accurate dosimeter readout and negligible spatial distortion. The use of optical simulations and 3D printing to create a light collimating-tank has dramatically increased convenience and reduced costs by removing the need for expensive lenses and large volumes of refractive matching fluids.

60 APPLIED LIFE SCIENCES↗