Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Diffraction optics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Fast scanning in x-ray microscopy: the effects of offset in the central stop position

Scanning of lightweight circular diffractive optics, separate from central stops and apertures, is emerging as an approach to exploit advances in synchrotron x-ray sources. We consider the effects in a scanning microscope of offsets between the optic and its central stop and find that scan ranges of up to about half the diameter of the optic are possible with only about a 10% increase in the focal spot width. Finally, for large scanning ranges, we present criteria for the working distance between the last aperture and the specimen to be imaged.

47 OTHER INSTRUMENTATION↗

Snapshot multifocal light field microscopy

Light field microscopy (LFM) is an emerging technology for high-speed wide-field 3D imaging by capturing 4D light field of 3D volumes. However, its 3D imaging capability comes at a cost of lateral resolution. In addition, the lateral resolution is not uniform across depth in the light field dconvolution reconstructions. To address these problems, here, we propose a snapshot multifocal light field microscopy (MFLFM) imaging method. The underlying concept of the MFLFM is to collect multiple focal shifted light fields simultaneously. We show that by focal stacking those focal shifted light fields, the depth-of-field (DOF) of the LFM can be further improved but without sacrificing the lateral resolution. Also, if all differently focused light fields are utilized together in the deconvolution, the MFLFM could achieve a high and uniform lateral resolution within a larger DOF. We present a house-built MFLFM system by placing a diffractive optical element at the Fourier plane of a conventional LFM. The optical performance of the MFLFM are analyzed and given. Both simulations and proof-of-principle experimental results are provided to demonstrate the effectiveness and benefits of the MFLFM. We believe that the proposed snapshot MFLFM has potential to enable high-speed and high resolution 3D imaging applications.

He, Kuan↗

Stabilization of the 81-channel coherent beam combination using machine learning

We develop a rapidly converging algorithm for stabilizing a large channel-count diffractive optical coherent beam combination. An 81-beam combiner is controlled by a novel, machine-learning based, iterative method to correct the optical phases, operating on an experimentally calibrated numerical model. A neural-network is trained to detect phase errors based on interference pattern recognition of uncombined beams adjacent to the combined one. Due to the non-uniqueness of solutions in the full space of possible phases, the network is trained within a limited phase perturbation/error range. This also reduces the number of samples needed for training. Simulations have proven that the network can converge in one step for small phase perturbations. When the trained neural-network is applied to a realistic case of 360 degree full range, an iterative scheme exploits random walking at the beginning, with the accuracy of prediction on phase feedback direction, to allow the neural-network to step into the training range for fast convergence. This neural-network-based iterative method of phase detection works tens of times faster than the commonly used stochastic parallel gradient descent approach (SPGD) using a single-detector and random dither when both are tested with random phase perturbations.

Wang, Dan↗

Maskless Fourier transform holography

Fourier transform holography is a lensless imaging technique that retrieves an object's exit-wave function with high fidelity. It has been used to study nanoscale phenomena and spatio-temporal dynamics in solids, with sensitivity to the phase component of electronic and magnetic textures. However, the method requires an invasive and labor-intensive nanopatterning of a holography mask directly onto the sample, which can alter the sample properties, forces a fixed field-of-view, and leads to a low signal-to-noise ratio at high resolution. In this work, we propose using wavefront-shaping diffractive optics to create a structured probe with full control of its phase at the sample plane, circumventing the need for a mask. We demonstrate in silico that the method can image nanostructures and magnetic textures and validate our approach with a visible light-based experiment. The method enables investigation of a plethora of phenomena at the nanoscale including magnetic and electronic phase coexistence in solids, with further uses in soft and biological matter research.

Keskinbora, Kahraman↗

Single-shot spatiotemporal plasma density measurements with a chirped probe pulse

In this work, we present the development and demonstration of a diagnostic for the measurement of the spatial and temporal evolution of plasma density in a single shot. Single-shot Advanced Plasma Probe HolographIc REconstruction (SAPPHIRE) utilizes a chirped probe pulse, a diffractive optical element, a self-referenced interferometer, and an interference bandpass filter to achieve high-fidelity electron density measurements suitable for underdense plasmas that exhibit cylindrical symmetry. The method overcomes limitations in conventional diagnostics, such as reliance on shot-to-shot reproducibility, while capturing plasma dynamics on picosecond timescales with micron-level spatial resolution. The capabilities of SAPPHIRE are demonstrated through measurements of laser-driven plasma channels in helium–nitrogen gas jets. SAPPHIRE demonstrates the formation and expansion of plasma channels in a single shot and the propagation of supersonic ionization fronts while revealing shot-to-shot variations in the plasma profiles. Experimental results are validated against theoretical models and scaling laws, underscoring the robustness and accuracy of this technique. By enabling ultrafast, high-resolution plasma diagnostics in a single exposure, SAPPHIRE represents a transformative advancement in plasma measurement technology.

Grace, Elizabeth S. [Lawrence Livermore National L↗

Acousto-optic tunable filter.

Electronically tunable lithium niobate optical filter utilizing collinear acousto-optic diffraction in anisotropic medium

Harris, S. E.↗

Methods of analyzing microsize particulate aerosols and contaminants.

Methods for analyzing atmospheric aerosols and particulate contaminants from natural and industrial sources are briefly described. Their development was spurred by interest in cosmic dust investigations. These methods make it possible to analyze individual particles ranging in size from 0.01 to 1000 microns for elemental and mineralogical content. The described methods include transmission electron microscopy, scanning electron microscopy, electron probe microanalysis, X-ray diffraction, optical mineralogy, and density measurement.

Blanchard, M. B.↗

Automated thematic mapping and change detection of ERTS-A images

The author has identified the following significant results. For the exploitation of the ERTS-1 images, both multispectral and spatial pattern recognition techniques are important. A multispectral recognition software program was successfully tested. A technique for the generation of resource boundaries has been successfully combined with terrain recognition software resulting in a regionalized terrain classification system. Digital registration of multispectral images has been achieved. Also, photointerpretation results from one test site are reported and the development of spatial terrain signatures from optical diffraction patterns is described.

Gramenopoulos, N.↗

Analysis of a dual-reflector antenna system using physical optics and digital computers

The application of physical-optics diffraction theory to a deployable dual-reflector geometry is discussed. The methods employed are not restricted to the Conical-Gregorian antenna, but apply in a general way to dual and even multiple reflector systems. Complex vector wave methods are used in the Fresnel and Fraunhofer regions of the reflectors. Field amplitude, phase, polarization data, and time average Poynting vectors are obtained via an IBM 360/91 digital computer. Focal region characteristics are plotted with the aid of a CalComp plotter. Comparison between the GSFC Huygens wavelet approach, JPL measurements, and JPL computer results based on the near field spherical wave expansion method are made wherever possible.

Schmidt, R. F.↗

Experiment K305: Quantitative analysis of selected bone parameters. Supplement 3A: Trabecular spacing and orientation in the long bones

Values of mean trabecular spacing computed from optical diffraction patterns of 1:1 X-ray micrographs of tibial metaphysis and those obtained by standard image digitization techniques show excellent agreement. Upper limits on values of mean trabecular orientation deduced from diffraction patterns and the images are also in excellent agreement. Values of the ratio of mean trabecular spatial density in a region of 300 micrometers distal to the downwardly directed convexity in the cartilage growth plate to the value adjacent to the plate determined for flight animals sacrificed at recovery were significantly smaller than values for vivarium control animals. No significant differences were found in proximal regions. No significant differences in mean trabecular orientation were detected. Decreased values of trabecular spatial density and of both obsteoblastic activity and trabecular cross-sectional area noted in collateral researches suggest decreased modeling activity under weightlessness.

Judy, M. M.↗

Coaxial carbon plasma gun deposition of amorphous carbon films

A unique plasma gun employing coaxial carbon electrodes was used in an attempt to deposit thin films of amorphous diamond-like carbon. A number of different structural, compositional, and electrical characterization techniques were used to characterize these films. These included scanning electron microscopy, scanning transmission electron microscopy, X ray diffraction and absorption, spectrographic analysis, energy dispersive spectroscopy, and selected area electron diffraction. Optical absorption and electrical resistivity measurements were also performed. The films were determined to be primarily amorphous, with poor adhesion to fused silica substrates. Many inclusions of particulates were found to be present as well. Analysis of these particulates revealed the presence of trace impurities, such as Fe and Cu, which were also found in the graphite electrode material. The electrodes were the source of these impurities. No evidence of diamond-like crystallite structure was found in any of the film samples. Details of the apparatus, experimental procedure, and film characteristics are presented.

Sater, D. M.↗

Interpolation Methods for GTD Analysis of Shaped Reflectors

The finding of smooth analytic representations for antenna reflector surfaces which are prescribed only by discretized data obtained by various synthesis methods is examined. Frequently the data are distributed in a nonuniform grid and contain noise. The smoothness required is to C sub 1 for physical optics diffraction analysis and to C sub 2 for geometrical theory of diffraction (GTD) analysis. The GTD analysis approach requires a surface description which returns data very rapidly. Two methods of interpolation, the global and the local methods, are discussed. They each have advantages and disadvantages; characteristics are discussed and examples are presented.

Galindo-Israel, V.↗

Compact acoustic levitation device for studies in fluid dynamics and material science in the laboratory and microgravity

An ultrasonic levitation device operable in both ordinary ground-based as well as in potential space-borne laboratories is described together with its various applications in the fields of fluid dynamics, material science, and light scattering. Some of the phenomena which can be studied by this instrument include surface waves on freely suspended liquids, the variations of the surface tension with temperature and contamination, the deep undercooling of materials with the temperature variations of their density and viscosity, and finally some of the optical diffraction properties of transparent substances.

Trinh, E. H.↗

Solidification of Nb-Ge alloys in long drop tubes

The 30-m and 100 m-long drop tubes at the Marshall Space Flight Center have been used to obtain large undercooling in Nb-Ge alloys. Electron beam melting has been used to obtain drops approximately 2.5 mm in diam. In the 30-m tube, many specimens fell the length of the tube without solidifying, and were ultimately liquid-quenched in oil. The amount of undercooling prior to the quench was usually around 0.13 T(m). In the 100-m tube, freezing generally initiated during free fall, and the maximum undercooling was around 0.22 T(m). Microstructures were characterized by a combination of X-ray diffraction, optical microscopy, and scanning electron microscopy with energy dispersive analysis by X-rays. A variety of interesting microstructures was observed.

Bayuzick, R. J.↗

Design analysis of the astrometrical telescope facility

This paper presents a detailed analysis of a space-based telescope requiring an accuracy of 50 pico radians. A relationship between the geometric centroid of a diffraction image and wave aberrations is derived by a combination approach of diffraction optics and geometric optics. Based on sensitivity of the centroid, one-mirror and two-mirror aplanatic telescopes are investigated. The comparison among three telescopes, parabola, Schwartzschild and Ritchey-Chretien are quantitatively carried out in terms of their sensitivities to the systematic errors and random errors. The study shows that the Ritchey-Chretien design is the most preferable.

Huang, Chunsheng↗

On the theory of the synthesis of offset dual-shaped reflectors - Case examples

In an earlier paper by Galindo-Israel et al. (1987), the geometrical optics (GO) principles, constraints, and requirements of the dual- and single-offset-shaped reflector synthesis problem were collected and developed into a set of nonlinear first-order PDEs. An extension of the methods by which solutions to the PDEs can be obtained is presented, together with several case examples. These examples are independently analyzed by GO and physical optics diffraction methods. The starting point for the integration over each reflector can be taken on the outer rim, at the center, or at an intermediate point-the intermediate starting point being the more general case. The utility of the speed of this synthesis method is demonstrated. For example, the program utilized completes a synthesis in less than 45 s on a 386/20 personal computer and within a fraction of a second on a mainframe Cray. This makes practical the incorporation of the synthesis into a search algorithm that can optimize one or more parameters of the reflector system. As an example, the optimization of the mapping equations for low cross polarization is discussed.

Galindo-Israel, Victor↗

Surface migration and volume diffusion in the AgGaSe2-Ag2Se system

Surface migration and volume diffusion in the Ag2Se-AgGaSe2 system were investigated using reactive diffusion couples which were analyzed by X-ray diffraction, optical microscopy, and electron probe microanalysis. The surface diffusivities of all mobile species are found to be much larger than volume diffusivities. The results of the study suggest that Se moves together with Ag and Ga to maintain binary (Ag2Se and Ga2Se3) stoichiometry and electroneutrality. The dominance of surface migration kinetics can account for the uniform annihilation of second-phase precipitates during heat treatments.

Kim, N.-H.↗

Cardiac morphology after conditions of microgravity during Cosmos 2044

Light- and electron-microscopic studies were performed on cardiac muscle from rats flown on Cosmos 2044 and from four control groups. Average cross-sectional area of myofibers was measured by video analysis of the light-microscopic images of papillary and ventricular muscle samples from all animals. This cross-sectional area was significantly decreased in flight rats (P = 0.03) compared with synchronous controls. Additional findings at the electron microscopic level consistent with this atrophy were obtained by stereological analysis and optical diffraction analysis of papillary muscle samples. Slightly higher mitochondrial volume density values and mitochondria-to-myofibril ratios as well as normal A-band spacings (d1,0) and Z-band spacings of myofibrils were observed in the tail-suspension and flight groups. General morphological features similar to those in ventricular samples from the previous Cosmos 1887 flight were observed.

Goldstein, Margaret A.↗