Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Developing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

U.S. Manufacturing Water Use Data and Estimates: Current State, Limitations, and Future Needs for Supporting Manufacturing Research and Development

Water is essential to manufacturing operations; without it, many facilities could not operate or meet production demands. Physical, reputational, and regulatory risks to water supplies compounded by climate change-induced impacts on hydrological conditions threaten the adequacy of water supplies for manufacturing. Manufacturing water use has not been a major focus of either water or manufacturing-related research. Research and development (R&D) aimed at helping manufacturers use water more sustainably and adapt to changing water conditions is needed to ensure a thriving sector and economy. However, the ability to identify R&D needs is severely limited due to a lack of current, statistically representative data on manufacturing water use and its environmental implications. In this Perspective, we outline four key questions to inform R&D on manufacturing use and highlight how the current state of water data in the United States does not support the adequate investigation of these questions. We make recommendations for the water data characteristics needed to explore the research questions and knowledgeably inform R&D on manufacturing water use.

McCall, James↗

Perspectives on the Development of Oxide-Based Photocathodes for Solar Fuel Production

Photoelectrochemical cells (PECs), which use semiconductor electrodes (photoelectrodes) to absorb solar energy and perform chemical reactions, constitute one of the most attractive strategies to produce chemical fuels using renewable energy sources. Oxide-based photoelectrodes specifically have been intensively investigated for the construction of PECs due to their relatively inexpensive processing costs and better stability in aqueous media compared with other types of photoelectrodes. Although there have been many advancements in the development of oxide-based photoanodes, our understanding of oxide-based photocathodes remains limited. The goal of this Perspective is to examine the recent progress made in the field of oxide-based photocathodes and discuss future research directions. The photocathode systems considered here include binary and ternary Cu-based photocathodes and ternary Fe-based photocathodes. Here, we assessed the characteristics and major advantages and drawbacks of each system and identified the most critical research gaps. The insights and discussions provided in this Perspective will serve as useful resources for the design of future studies, leading to the development of more efficient and practical PECs.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Use of steric encumbrance to develop conjugated nanoporous polymers for metal-free catalytic hydrogenation

The design and synthesis of metal-free heterogeneous catalysts for efficient hydrogenation remains a great challenge. Here we report a novel approach to create conjugated nanoporous polymers with efficient hydrogenation activities toward unsaturated ketones by leveraging the innate steric encumbrance. The steric bulk of the framework as well as the local sterics of the Lewis basic sites within the polymeric skeleton result in the generation of the putative catalyst. Lastly, this approach opens up new possibilities for the development of innovative metal-free heterogeneous catalysts.

36 MATERIALS SCIENCE↗

Nonlinear development of the two-plasmon decay instability in three dimensions

Most recent experiments on the excitation of the two plasmon-decay (TPD) instability involve a three-dimensional (3D) array of overlapping laser beams. Our recent two dimensional (2D) simulations suggested that Langmuir cavitation and collapse are important nonlinear saturation mechanisms for TPD. There are important quantitative differences in the Langmuir collapse process in 2D and 3D. To address these and other issues, we have developed a 3D Zakharov code. It has been applied to study the evolution of TPD from absolute instabilities (arising from 3D laser geometries) to the nonlinear state (J. Zhang et al., Phys. Rev. Lett. (submitted)). The present paper concentrates on the nonlinear saturated state excited by the collective action of two crossed laser beams with arbitrary polarizations. Remarkable agreement between 3D and 2D simulations is found for several averaged physical quantities when the beams are polarized in their common plane. As in the previous 2D simulations, we find: (a) the collective, initially convectively unstable triad modes dominate after a sub-picosecond burst, (b) Langmuir cavitation and collapse are important nonlinearities, and (c) that the statistics of intense cavitons are characteristic of a Gaussian random process. The 3D steady-state saturated Langmuir energy level is about 30% higher than in 2D. The auto-correlation functions of the Langmuir envelope field and of the low-frequency electron density field yield the spatial shape of the strongest collapsing cavitons which are 3D ellipsoids whose orientation depends on the laser polarizations. This tilting of the caviton's strongest electric field direction away from the normal to the target surface is a major new 3D result. This tilting may deflect the hot electron flux and thereby mitigate target preheat.

Vu, H. X.↗

Development of the CD Symcap platform to study gas-shell mix in implosions at the National Ignition Facility

Surrogate implosions play an important role at the National Ignition Facility (NIF) for isolating aspects of the complex physical processes associated with fully integrated ignition experiments. The newly developed CD Symcap platform has been designed to study gas-shell mix in indirectly driven, pure T{sub 2}-gas filled CH-shell implosions equipped with 4 μm thick CD layers. This configuration provides a direct nuclear signature of mix as the DT yield (above a characterized D contamination background) is produced by D from the CD layer in the shell, mixing into the T-gas core. The CD layer can be placed at different locations within the CH shell to probe the depth and extent of mix. CD layers placed flush with the gas-shell interface and recessed up to 8 μm have shown that most of the mix occurs at the inner-shell surface. In addition, time-gated x-ray images of the hotspot show large brightly radiating objects traversing through the hotspot around bang-time, which are likely chunks of CH/CD plastic. This platform is a powerful new capability at the NIF for understanding mix, one of the key performance issues for ignition experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Design and development of an in-line sputtering system and process development of thin film multilayer neutron supermirrors

Neutron supermirrors and supermirror polarizers are thin film multilayer based devices which are used for reflecting and polarizing neutrons in various neutron based experiments. In the present communication, the in-house development of a 9 m long in-line dc sputtering system has been described which is suitable for deposition of neutron supermirrors on large size (1500 mm × 150 mm) substrates and in large numbers. The optimisation process of deposition of Co and Ti thin film, Co/Ti periodic multilayers, and a-periodic supermirrors have also been described. The system has been used to deposit thin film multilayer supermirror polarizers which show high reflectivity up to a reasonably large critical wavevector transfer of ∼0.06 Å{sup −1} (corresponding to m = 2.5, i.e., 2.5 times critical wavevector transfer of natural Ni). The computer code for designing these supermirrors has also been developed in-house.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Development of nanosecond time-resolved infrared detection at the LEAF pulse radiolysis facility

When coupled with transient absorption spectroscopy, pulse radiolysis, which utilizes high-energy electron pulses from an accelerator, is a powerful tool for investigating the kinetics and thermodynamics of a wide range of radiation-induced redox and electron transfer processes. The majority of these investigations detect transient species in the UV, visible, or near-IR spectral regions. Unfortunately, the often-broad and featureless absorption bands in these regions can make the definitive identification of intermediates difficult. Time-resolved vibrational spectroscopy would offer much improved structural characterization, but has received only limited application in pulse radiolysis. In this paper, we describe in detail the development of a unique nanosecond time-resolved infrared (TRIR) detection capability for condensed-phase pulse radiolysis on a new beam line at the LEAF facility of Brookhaven National Laboratory. The system makes use of a suite of high-power, continuous wave external-cavity quantum cascade lasers as the IR probe source, with coverage from 2330-1051 cm⁻¹. The response time of the TRIR detection setup is ~40 ns, with a typical sensitivity of ~100 µOD after 4-8 signal averages using a dual-beam probe/reference normalization detection scheme. As a result, this new detection method has enabled mechanistic investigations of a range of radiation-induced chemical processes, some of which are highlighted here.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Bright x-ray stainless steel K-shell source development at the National Ignition Facility

High x-ray conversion efficiency (XRCE) K-shell sources are being developed for high energy density experiments for use as backlighters and for the testing of materials exposed to high x-ray fluxes and fluences. Recently, sources with high XRCE in the K-shell x-ray energy range of iron and nickel were investigated at the National Ignition Facility (NIF). The x-ray conversion efficiency in the 5–9 keV spectral range was determined to be 6.8% ± 0.3%. These targets were 4.1 mm diameter, 4 mm tall hollow epoxy tubes having a 50 μm thick wall supporting a tube of 3 to 3.5 μm thick stainless steel. The NIF laser deposited ∼460 kJ of 3ω light into the target in a 140 TW, 3.3 ns square pulse. The absolute x-ray emission of the source was measured by two calibrated Dante x-ray spectrometers. Time resolved images filtered for the Fe K-shell were recorded to follow the heating of the target. Time integrated high-resolution spectra were recorded in the K-shell range.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a reaction cell for in-situ/operando studies of surface of a catalyst under a reaction condition and during catalysis

Tracking surface chemistry of a catalyst during catalysis is significant for fundamental understanding of catalytic performance of the catalyst since it allows for establishing an intrinsic correlation between surface chemistry of a catalyst at its working status and its corresponding catalytic performance. Ambient pressure X-ray photoelectron spectroscopy can be used for in-situ studies of surfaces of different materials or devices in a gas. To simulate the gaseous environment of a catalyst in a fixed-bed a flowing gaseous environment of reactants around the catalyst is necessary. Here, we report the development of a new flowing reaction cell for simulating in-situ study of a catalyst surface under a reaction condition in gas of one reactant or during catalysis in a mixture of reactants of a catalytic reaction. The homemade reaction cell is installed in a high vacuum (HV) or ultrahigh vacuum (UHV) environment of a chamber. The flowing gas in the reaction cell is separated from the HV or UHV environment through well sealings at three interfaces between the reaction cell and X-ray window, sample door and aperture of front cone of an energy analyzer. Catalyst in the cell is heated through infrared laser beam introduced through a fiber optics interfaced with the reaction cell through a homemade feedthrough. The highly localized heating on the sample holder and Au-passivated internal surface of the reaction cell effectively minimizes any unwanted reactions potentially catalyzed by the reaction cell. The incorporated laser heating allows a fast heating and a high thermal stability of the sample at a high temperature. With this cell, a catalyst at 800 °C in a flowing gas can be tracked readily.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development and implementation of a portable grating interferometer system as a standard tool for testing optics at the Advanced Photon Source beamline 1-BM

We developed a portable X-ray grating interferometer setup as a standard tool for testing optics at the Advanced Photon Source (APS) beamline 1-BM. The interferometer can be operated in phase-stepping, Moiré, or single-grating harmonic imaging mode with 1-D or 2-D gratings. All of the interferometer motions are motorized; hence, it is much easier and quicker to switch between the different modes of operation. A novel aspect of this new instrument is its designed portability. While the setup is designed to be primarily used as a standard tool for testing optics at 1-BM, it could be potentially deployed at other APS beamlines for beam coherence and wavefront characterization or imaging. Herein, the design of the interferometer system is described in detail and coherence measurements obtained at the APS 34-ID-E beamline are presented. The coherence was probed in two directions using a 2-D checkerboard, a linear, and a circular grating at X-ray energies of 8 keV, 11 keV, and 18 keV.

47 OTHER INSTRUMENTATION↗

Progress on the development of the next generation x-ray beam position monitors at the advanced photon source

Accurate and stable x-ray beam position monitors (XBPMs) are key elements in obtaining the desired user beam stability in the Advanced Photon Source (APS). The next generation XBPMs for high heat load front ends (HHL FEs) have been designed to meet these requirements by utilizing Cu K-edge x-ray fluorescence (XRF) from a pair of copper absorbers and have been installed at the front ends (FEs) of the APS. Commissioning data showed a significant performance improvement over the existing photoemission-based XBPMs. While a similar design concept can be applied for the canted undulator front ends, where two undulator beams are separated by 1.0-mrad, the lower beam power (< 10 kW) per undulator allows us to explore lower-cost solutions based on Compton scattering from the diamond blades placed edge-on to the x-ray beam. A prototype of the Compton scattering XBPM system was installed at 24-ID-A in May 2015. In this report, the design and test results for XRF-based XBPM and Compton scattering based XBPM are presented. Ongoing research related to the development of the next generation XBPMs on thermal contact resistance of a joint between two solid bodies is also discussed.

43 PARTICLE ACCELERATORS↗

Developments in time-resolved x-ray research at APS beamline 7ID

The 7ID beamline of the Advanced Photon Source (APS) is dedicated to time-resolved research using x-ray imaging, scattering, and spectroscopy techniques. Time resolution is achieved via gated detectors and/or mechanical choppers in conjunction with the time structure of the x-ray beam. Three experimental hutches allow for a wide variety of experimental setups. Major areas of research include atomic, molecular, and optical physics; chemistry; condensed matter physics in the bulk, thin film, and surface regimes; and fluid-spray dynamics. Recent developments in facilities at 7ID include a high-power, high-repetition-rate picosecond laser to complement the 1 kHz ultrafast laser. For the ultrafast laser, a newly commissioned optical parametric amplifier provides pump wavelength from 0.2 to 15 µm with energy per pulse up to 200 µJ. A nanodiffraction station has also been commissioned, using Fresnel zone-plate optics to achieve a focused x-ray spot of 300 nm. This nanoprobe is not only used to spatially resolve the evolution of small features in samples after optical excitation, but also has been combined with an intense THz source to study material response under ultrafast electric fields.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a beam ion velocity detector for the heavy ion beam probe

In an axisymmetric plasma, the conservation of canonical angular momentum constrains heavy ion beam probe (HIBP) trajectories such that measurement of the toroidal velocity component of secondary ions provides a localized determination of the poloidal flux at the volume where they originated. We have developed a prototype detector which is designed to determine the beam angle in one dimension through the detection of ion current landing on two parallel planes of detecting elements. A set of apertures creates a pattern of ion current on wires in the first plane and solid metal plates behind them; the relative amounts detected by the wires and plates determine the angle which beam ions enter the detector, which is used to infer the toroidal velocity component. The design evolved from a series of simulations within which we modeled ion beam velocity changes due to equilibrium and fluctuating magnetic fields, along with the ion beam profile and velocity dispersion, and studied how these and characteristics such as the size, cross section, and spacing of the detector elements affect performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a krypton-doped gas symmetry capsule platform for x-ray spectroscopy of implosion cores on the NIF

The electron temperature at stagnation of an ICF implosion can be measured from the emission spectrum of high-energy x-rays that pass through the cold material surrounding the hot stagnating core. Here we describe a platform developed on the National Ignition Facility where trace levels of a mid-Z dopant (krypton) are added to the fuel gas of a symcap (symmetry surrogate) implosion to allow for the use of x-ray spectroscopy of the krypton line emission.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of miniaturized, spectroscopically assisted Penning gauges for fractional helium and hydrogen neutral pressure measurements

Direct measurements of the helium (He) fractional neutral pressure in the neutral gas around fusion devices is challenging because of the small mass difference between the abundant D{sub 2} molecules and the He ash which will be produced by deuterium-tritium fusion. To study He exhaust, an in situ Penning gauge system is being developed at UW-Madison that is optimized for good pressure and high spectroscopic sensitivity. Three different anode geometries have been studied regarding their vacuum electrostatic fields, light output, and ion current. The light output of the two new anode configurations are at least one order of magnitude above the currently available designs, hence improving the spectroscopic sensitivity at similar total neutral pressure resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of the materials analysis and particle probe for Proto-MPEX

The Prototype Material Plasma Exposure eXperiment (Proto-MPEX) is a linear plasma device being used in plasma source research and development (R&D) for the proposed MPEX. Once the R&D is completed, this device can also be used to perform plasma–material interaction studies. To perform these studies, a new materials analysis and particle probe (MAPP) has been constructed. The MAPP’s components are a sample holder and manipulator and a custom vacuum chamber with ports to facilitate surface chemistry diagnostics. The MAPP’s overall design enables rapid sample turnaround and in vacuo surface characterization. The surface analysis vacuum chamber has ports for x-ray photoelectron spectroscopy, thermal desorption spectroscopy, back-scatter ion scattering spectroscopy, forward-scatter ion scattering spectroscopy, and direct recoil spectroscopy. The sample manipulator and holder is a Lesker/UHV Multi-Centre Analytical Stage, which is used to place the samples in the exposure region of the Proto-MPEX or the analysis position in the MAPP vacuum chamber. The sample holder has a heating capability of up to 1200 °C for heated exposure and for desorption studies. In this work, we present the MAPP’s design and the first tungsten sample exposure with ex situ analysis that shows a surface deposition layer on the exposed target, highlighting the need for additional in situ measurements on the Proto-MPEX.

Beers, C. J. (ORCID:0000000150985459)↗