Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Detectors Instrumentation Imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

MISR Level 1B1 Local Mode Radiance Data (MIB1LM_V2)

The results of two types of processing are included in this product. First, the Radiance Scaling operation converts the camera's digital number output to a measure of energy incident on the front optical surface. The measurement is expressed in units called radiance (energy per unit area, wavelength, and solid angle) as defined by the International Standard (SI). Second, Radiance Conditioning modifies the radiances to remove instrument-dependent effects. Specifically, image sharpening is applied, and focal-plane scattering is removed. Additionally, all radiances are adjusted to remove slight spectral sensitivity differences among the 1504 detector elements of each spectral band and each camera. In addition to the Level 1B1 radiometric product for MISR's Global Mode imagery, there is a separate Level 1B1 product for each high-resolution Local Mode scene. The Radiometric Product contains spectral radiances for all MISR channels (four spectral bands and nine cameras). Each radiance value represents the incident radiance averaged over the sensor's total band response. Processing includes both radiance scaling and conditioning steps. Radiance scaling converts the Level 1A data from digital counts to radiances using coefficients derived in combination with the On-Board Calibrator (OBC) and vicarious calibrations. The OBC contains Spectralon calibration panels which are deployed monthly and reflect sunlight into the cameras. The OBC detector standards then measure this reflected light to provide the calibration. Vicarious field campaigns are conducted less frequently but provide an independent methodology useful for reducing systematic errors. Radiance conditioning removes undesirable instrument effects. Image enhancement is provided by deconvolving the scene with the sensor's point-spread-function. Additionally, in-band scaling adjusts the reported radiances to correspond to a nominal band response profile. This frees the Level 2 software from the need to correct for detector element non-uniformities. No out-of-band correction is done for this product, nor are the data geometrically corrected or resampled at this point. In summary, the Level 1B1 Product contains the Data Numbers (DNs) radiometrically-scaled to radiances with no geometric resampling. [Temporal_Coverage: Start_Date=2000-02-24; Stop_Date=] [Spatial_Coverage: Southernmost_Latitude=-90; Northernmost_Latitude=90; Westernmost_Longitude=-180; Easternmost_Longitude=180] [Data_Resolution: Latitude_Resolution=275 m for red band only; Longitude_Resolution=275 m for red band only; Temporal_Resolution=about 15 orbits/day].

AM-1↗

Fabrication of MgF2 and LiF windows for the Hubble Space Telescope Imaging Spectrograph

Two prototype test windows (MgF2 and LiF) to be used on the 75-mm UV MAMA detector tubes for the Hubble Space Telescope Imaging Spectrograph are described. The spatial and optical constraints of this instrument dictate that the thickness of the window materials be no greater than 2-3 mm to achieve a minimum 50-percent transmission at hydrogen Lyman alpha (121.6 nm), and that the window must be domed to minimize optical aberrations and provide structural strength. The detector window has an input diameter of about 100 mm with a radius-of-curvature of 70 mm. The manufacturing processes involved in the fabrication of these windows is discussed, as well as test programs (optical and structural) to be performed at Goddard Space Flight Center.

Gormley, Daphne↗

Ultraviolet stellar spectrophotometry from a balloon platform

A 40 centimeter diameter aperture, balloon-borne telescope and ultraviolet spectrometer is described and selected scientific results are briefly reviewed. The general configuration of the 0.4 angstrom resolution instrument is shown and the utilization of servo-controlled secondary mirror, image dissector detector, and special mirror coatings are discussed. An outlook for astronomical research in the mid-ultraviolet from balloon-borne telescopes is presented together with future development plans for JSC's balloon-borne payload.

Kondo, Y.↗

The Einstein Observatory - New perspectives in astronomy

The impact of high-resolution, high-sensitivity X-ray measurements obtained by the Einstein Observatory (HEAO-2) on various areas of astronomical research is discussed. Following a review of the Einstein instruments based on grazing incidence focusing X-ray optics, including the telescope, imaging detectors and spectrometers, consideration is given to observations of X-ray emission from stellar systems, galaxies, and clusters of galaxies. Einstein results concerning the X-ray luminosities of young O, B and A stars and late K and M stars, the temperature, composition and distribution of material ejected in supernova explosions and comprising the interstellar medium, the formation and evolution of stellar systems and galaxies, the energy source of quasars and active galactic nuclei and the mass distribution in galactic clusters are indicated. Substantial progress made possible by the high-resolution observations of the diffuse X-ray background in cosmological research is also noted.

Giacconi, R.↗

Maximizing the quantum efficiency of microchannel plate detectors - The collection of photoelectrons from the interchannel web using an electric field

High quantum efficiency and two-dimensional imaging capabilities make the microchannel plate (MCP) a suitable detector for a sky survey instrument. The Extreme Ultraviolet Explorer satellite, to be launched in 1987, will use MCP detectors. A feature which limits MCP efficiency is related to the walls of individual channels. The walls are of finite thickness and thus form an interchannel web. Under normal circumstances, this web does not contribute to the detector's quantum efficiency. Panitz and Foesch (1976) have found that in the case of a bombardment with ions, electrons were ejected from the electrode material coating the web. By applying a small electric field, the electrons were returned to the MCP surface where they were detected. The present investigation is concerned with the enhancement of quantum efficiencies in the case of extreme UV wavelengths. Attention is given to a model and a computer simulation which quantitatively reproduce the experimental results.

Taylor, R. C.↗

Observations of the plasma torus of Jupiter with a Fabry-Perot/charge-coupled device /CCD/ imaging spectrometer

A description is presented of the use of a CCD imaging spectrometer which has been employed at a 2.1 m telescope to obtain monochromatic images in the red and near infrared. The system studied was Jupiter's plasma torus which circles the planet with radial extent about 5 RJ and 7 RJ (RJ is the radius of Jupiter). In ground based measurements the torus has been observed in the forbidden emission lines of S(plus) at 6716 A and 6731 A and S(plus plus) at 9531 A. Attention is given to aspects of instrumentation, observations, and performance. It is felt that the particular significance of the obtained results from the instrumental point of view is the demonstration that the CCD is an excellent detector for monochromatic imaging in the near infrared out to at least 10830 A and that pixel binning before readout can produce significantly improved S/N ratios for the study of faint, diffuse sources in cases where readout noise is dominant.

Roesler, F. L.↗

Ultrawide bandgap semiconductor h-BN for direct detection of fast neutrons

III-nitride wide bandgap semiconductors have contributed on the grandest scale to many technological advances in lighting, displays, and power electronics. Among III-nitrides, BN has another unique application as a solid-state neutron detector material because the isotope B-10 is among a few elements that have an unusually large interaction cross section with thermal neutrons. A record high thermal neutron detection efficiency of 60% has been achieved by B-10 enriched h-BN detectors of 100 μm in thickness in our group. However, direct detection of fast neutrons with energies above 1 MeV is highly challenging due to the extremely low interaction cross section of fast neutrons with matter. We report the successful attainment of 0.4 mm thick freestanding h-BN 4"-diameter wafers, which enabled the demonstration of h-BN fast neutron detectors capable of delivering a detection efficiency of 2.2% in response to a bare AmBe neutron source. Furthermore, it was shown that the energy information of incoming fast neutrons is retained in the neutron pulse-height spectra. A comparison of characteristics between h-BN fast and thermal neutron detectors is summarized. Neutron detectors are vital diagnostic instruments for nuclear and fusion reactor power and safety monitoring, oil field exploration, neutron imaging and therapy, as well as for plasma and material science research. With the outstanding attributes resulting from its ultrawide bandgap (UWBG), including the ability to operate at extreme conditions of high power, voltage, and temperature, the availability of h-BN UWBG semiconductor detectors with the capability of simultaneously detecting thermal and fast neutrons with high efficiencies is expected to open unprecedented applications that are not possible to attain by any other types of neutron detectors.

36 MATERIALS SCIENCE↗

Imaging spectrometer technologies for advanced Earth remote sensing

A major requirement of multispectral imaging systems for advanced Earth remote sensing is the provision for greater spectral resolution and more versatile spectral band selection. The imaging spectrometer instrument concept provides this versatility by the combination of pushbroom imaging and spectrally dispersing optics using area array detectors in the focal plane. The shuttle imaging spectrometer concept achieves 10- and 20-meter ground instantaneous fields of view with 20-nanometer spectral resolution from Earth Orbit. Onboard processing allows the selection of spectral bands during flight; this, in turn, permits the sensor parameters to be tailored to the experiment objectives. Advances in optical design, infrared detector arrays, and focal plane cooling indicate the feasibility of the instrument concept and support the practicability of a validation flight experiment for the shuttle in the late 1980s.

Wellman, J. B.↗

Imaging spectrometer technologies for advanced earth remote sensing

A major requirement of multispectral imaging systems for advanced earth remote sensing is the provision for greater spectral resolution and more versatile spectral band selection. The imaging spectrometer instrument concept provides this versatility by the combination of pushbroom imaging and spectrally dispersing optics using area array detectors in the focal plane. The shuttle imaging spectrometer concept achieves 10- and 20-meter ground instantaneous fields of view with 20-nanometer spectral resolution from earth orbit. Onboard processing allows the selection of spectral bands during flight; this, in turn, permits the sensor parameters to be tailored to the experiment objectives. Advances in optical design, infrared detector arrays, and focal plane cooling indicate the feasibility of the instrument concept and support the practicability of a validation flight experiment for the shuttle in the late 1980s. Previously announced in STAR as N83-28542

Wellman, J. B.↗

Imaging pulse-counting detector systems for space ultraviolet astrophysics missions

A family of imaging, pulse-counting, photoelectric detector systems, the Multi-Anode Microchannel Arrays (MAMAs), are now under active development for use on a number of space ultraviolet astrophysics missions at far-ultraviolet (FUV) and extreme-ultraviolet wavelengths between about 300 and 28 nm. Specifically, MAMA detectors are being fabricated and tested for use in two instruments on the ESA/NASA Solar and Heliospheric Observatory mission, for the NASA Goddard Space Flight Center's Hubble Space Telescope Imaging Spectrograph, and for the prime FUV spectrograph of the Far Ultraviolet Spectroscopic Explorer FUSE/Lyman mission. The construction and performance characteristics of the different MAMA detector systems are described, and techniques for improving the spatial resolution of each of the detector systems by the use of custom application specific integrated circuits in the electronics are discussed.

Timothy, J. G.↗

A moderate-resolution, wide-band, astronomical echelle spectrograph

An echelle spectrograph is described which is specifically designed for use on a 52-in. f/7.6 telescope as an instrument optimally suited for studying spectra of the faint optical counterparts to X-ray stars at moderate spectral resolution. The spectrograph is also able to accomodate a two-dimensional photon-tagging panoramic image detector so that high-time-resolution studies of the spectra of variable stars can be carried out. The equations for echelle spectrographs are summarized, and some features of the present instrument are discussed. These include its prism cross-disperser, small elliptical flat mirror, and unusually high efficiency. An iron-argon calibration spectrum obtained by pressing the film against the output fiber optics of a three-stage electrostatically focused image intensifier, a spectrum of P Cygni taken by placing the film directly in the image plane of the spectrograph, and a photon-counted image of a small section of an echellogram produced during an observation of the Ring nebula in Lyra are provided to illustrate the performance of the instrument.

Bardas, D.↗

Large Format Arrays for Far Infrared and Millimeter Astronomy

Some of the most compelling questions in modem astronomy are best addressed with submillimeter and millimeter observations. The question of the role of inflation in the early evolution of the universe is best addressed with large sensitive arrays of millimeter polarimeters. The study of the first generations of galaxies requires sensitive submillimeter imaging, which can help us to understand the history of energy release and nucleosynthesis in the universe. Our ability to address these questions is dramatically increasing, driven by dramatic steps in the sensitivity and size of available detector arrays. While the MIPS instrument on the SIRTF mission will revolutionize far infrared astronomy with its 1024 element array of photoconductors, thermal detectors remain the dominant technology for submillimeter and millimeter imaging and polarimetry. The last decade has seen the deployment of increasingly large arrays of bolometers, ranging from the 48 element arrays deployed on the KAO in the late 198Os, to the SHARC and SCUBA arrays in the 1990s. The past years have seen the deployment of a new generation of larger detector arrays in SHARC II (384 channels) and Bolocam (144 channels). These detectors are in operation and are beginning to make significant impacts on the field. Arrays of sensitive submillimeter bolometers on the SPIRE instrument on Herschel will allow the first large areas surveys of the sky, providing important insight into the evolution of galaxies. The next generation of detectors, led by SCUBA II, will increase the focal scale of these instruments by an order of magnitude. Two major missions are being planned by NASA for which further development of long wavelength detectors is essential, The SAFlR mission, a 10-m class telescope with large arrays of background limited detectors, will extend our reach into the epoch of initial galaxy formation. A major goal of modem cosmology is to test the inflationary paradigm in the early evolution of the universe. To this end, a mission is planned to detect the imprint of inflation on the CMB by precision measurement of its polarization. This work requires very large arrays of sensitive detectors which can provide unprecedented control of a wide range of systematic errors, given the small amplitude of the signal of interest. We will describe the current state of large format detector arrays, the performance requirements set by the new missions, and the different approaches being developed in the community to meet these requirements. We are confident that within a decade, these developments will lead to dramatic advances in our understanding of the evolution of the universe.

Moseley, Harvey↗

Extreme ultraviolet imaging spectrometer for thermospheric emissions

One of the instruments that has been developed to fly on the Space Shuttle is the Imaging Spectrometric Observatory, an array of five imaging spectrometers to cover the 300-12,000-A wavelength range. In this paper the spectrometer designed to operate in the extreme ultraviolet is described. The instrument is intended for studies of the thermosphere and magnetosphere and support of various plasma experiments to be performed from the Shuttle. The design is modular so that various components such as gratings and detectors can be changed and optimized for a range of specific studies following the first survey mission. The detector is an intensified 2-D CCD which permits simultaneous spectral and spatial imaging. The spectral multiplexing gives the spectrometer a considerable speed advantage. The instrument has a small field of view and is thus capable of obtaining much needed scale height information on the atmospheric EUV emissions. Operating from the Shuttle, global and temporal coverage will be obtained, and the EUV data will be enhanced by the simultaneously acquired UV, visible, and near-IR observations.

Torr, M. R.↗

Spatial imaging of UV emission from Jupiter and Saturn

Spatial imaging with the IUE is accomplished both by moving one of the apertures in a series of exposures and within the large aperture in a single exposure. The image of the field of view subtended by the large aperture is focussed directly onto the detector camera face at each wavelength; since the spatial resolution of the instrument is 5 to 6 arc sec and the aperture extends 23.0 by 10.3 arc sec, imaging both parallel and perpendicular to dispersion is possible in a single exposure. The correction for the sensitivity variation along the slit at 1216 A is obtained from exposures of diffuse geocoronal H Ly alpha emission. The relative size of the aperture superimposed on the apparent discs of Jupiter and Saturn in typical observation is illustrated. By moving the planet image 10 to 20 arc sec along the major axis of the aperture (which is constrained to point roughly north-south) maps of the discs of these planets are obtained with 6 arc sec spatial resolution.

Clarke, J. T.↗

Infrared radiometric technique in temperature measurement

One class of commercially available imaging infrared radiometers using cooled detectors is sensitive to radiation over the 3 to 12 micron wavelength band. Spectral filters can tailor instrument sensitivity to specific regions where the target exhibits optimum radiance. The broadband spectral response coupled with real time two-dimensional imaging and emittance/background temperature corrections make the instruments useful for remote measurement of surface temperatures from -20 C to +1500 C. Commonly used radiometric techniques and assumptions are discussed, and performance specifications for a typical modern commercial instrument are presented. The potential usefulness of an imaging infrared radiometer in space laboratories is highlighted through examples of research, nondestructive evaluation, safety, and routine maintenance applications. Future improvements in instrument design and application of the radiometric technique are discussed.

Glazer, S.↗

Charge-coupled device /CCD/ trackers for high accuracy guidance applications

Recent advances in large area charge coupled device (CCD) imaging detectors and high speed microprocessors have prompted the development of a new class of electro-optical tracking instruments at the Jet Propulsion Laboratory (JPL). These instruments are designed for standardized NASA-wide usage and are characterized by their extremely high pointing accuracy and stability and performance capabilities which are largely software defined and thus easily adapted to a variety of mission requirements. This paper presents an examination of the methods by which CCD detectors are being incorporated in star tracker instruments and the performance capabilities that can be expected from currently available devices. The multi-function sensor concept, in which a single sensor can function in a variety of guidance applications, is described. Software algorithms designed to provide efficient extraction of guidance information from both point and extended images are also presented. CCD star tracker implementations currently underway at JPL are described, and performance data obtained during laboratory testing is presented and discussed.

Salomon, P. M.↗

Very-High Dynamic Range, 10,000 Frames/Second Pixel Array Detector for Electron Microscopy

Precision and accuracy of quantitative scanning transmission electron microscopy (STEM) methods such as ptychography, and the mapping of electric, magnetic, and strain fields depend on the dose. Reasonable acquisition time requires high beam current and the ability to quantitatively detect both large and minute changes in signal. A new hybrid pixel array detector (PAD), the second-generation Electron Microscope Pixel Array Detector (EMPAD-G2), addresses this challenge by advancing the technology of a previous generation PAD, the EMPAD. The EMPAD-G2 images continuously at a frame-rates up to 10 kHz with a dynamic range that spans from low-noise detection of single electrons to electron beam currents exceeding 180 pA per pixel, even at electron energies of 300 keV. The EMPAD-G2 enables rapid collection of high-quality STEM data that simultaneously contain full diffraction information from unsaturated bright-field disks to usable Kikuchi bands and higher-order Laue zones. Test results from 80 to 300 keV are presented, as are first experimental results demonstrating ptychographic reconstructions, strain and polarization maps. We introduce a new information metric, the maximum usable imaging speed (MUIS), to identify when a detector becomes electron-starved, saturated or its pixel count is mismatched with the beam current.

36 MATERIALS SCIENCE↗

Exploring the Birth and Evolution of the Universe: How Detectors Have Revolutionized Space Astronomy

The past century has seen tremendous advances in the capability of instruments used for astronomical imaging and spectroscopy. Capabilities of instruments have expanded in many dimensions; the scale of telescopes has grown tremendously, the wavelengths used for astronomy have grown from visible light to the full electromagnetic spectrum, extending from gamma rays to low frequency radio waves. Additional advances have been enabled by the availability of space facilities, which eliminate the effects of the earths atmosphere and magnetosphere, and allow cooling of instruments to avoid instrumental thermal radiation. Even with all these advances, the increase in capability of detection systems has produced truly revolutionary improvements in capability. Today, I will describe the advances in astronomical detection from the photographic plates of the early 20th century to the giant high efficiency focal planes being developed for modern space and ground based astronomical instrument. I will review the demanding performance requirements set by space astronomy, and show how the detector community has risen to the challenge in producing high performance detectors for the Hubble Space Telescope, the Spitzer Space Telescope, and the James Webb Space Telescope, now under development.

Moseley, Samuel H.↗